}

Tender For Repair/Maintenance To Security Lights, High Mast Light And Perimeter Light Fittings In Tech/Domestic Areaand Repair To Certain Cables For Misc Work Crane , Doors, Flame Proof Light And Connected Work At 3 Brdunder Ge (Af) Mc Chandigarh, Chandigarh-Chandigarh

Military Engineer Services has published Tender For Repair/Maintenance To Security Lights, High Mast Light And Perimeter Light Fittings In Tech/Domestic Areaand Repair To Certain Cables For Misc Work Crane , Doors, Flame Proof Light And Connected Work At 3 Brdunder Ge (Af) Mc Chandigarh. Submission Date for this Tender is 04-09-2025. Street Lighting Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

50691383
Tender For Repair/Maintenance To Security Lights, High Mast Light And Perimeter Light Fittings In Tech/Domestic Areaand Repair To Certain Cables For Misc Work Crane , Doors, Flame Proof Light And Connected Work At 3 Brdunder Ge (Af) Mc Chandigarh
Tender
Indian
Chandigarh
Chandigarh
04-09-2025

Tender Details

Tender For Repair/Maintenance To Security Lights, High Mast Light And Perimeter Light Fittings In Tech/Domestic Areaand Repair To Certain Cables For Misc Work Crane , Doors, Flame Proof Light And Connected Work At 3 Brdunder Ge (Af) Mc Chandigarh; 1 Attendingcomplaints forstreet lights, flood lighst, LED bollards of any type, perimeter lights and high mast lights including accessories, Solar/ LED light fitting on wall or pole or ceiling of hanger and of any other locations to find out defects including dismantling of defective parts or taking down the fitting if necessary, cleaning the bowl/ perflex cover and making the fitting in 100% serviceable condition including rectification of fault of over head lines and under ground cables if any complete all as specified and directed by Engr-in-Charge. Note:(i) The contractor should employ one electrician and one helper for carrying out maintenance of street/security/bollard/flood light fittings in General Shift from 0900 hrs to 1700 hrs for Airforce school 3 BRD SEC 31,technical and domestic area of 3 BRD.(ii)All T&P/Safety items shall be provided by the contractor at his own cost.(iii)The Contractor shall rectify the compliant within 24 Hours otherwise penal charge will be imposed at the rate of Rs. 200 per complaint(iv) Contractorsquoted ratesto include arrangement of bucket crane of high height or ladder with wheels or hydra orany other means required to rectify the compliants at the height of 07 to 20 meter.Safety of the tradesmen employed shall be the responsibility of the contractor.(v) Defective parts such as LED driver/LED fittings/Bollard fittings will be measured and paid under relevent item separately.However cost of replacement of minor parts such as nut, bolt, washer,insulation tape etc shall be inclusive in quoted rates.Monthly means 30 days including sunday and gazetted holidays. 2 Supply only LED driver suitable for LED bollardlight fitting for any make as per site requirement of capacity upto 20 watt, complete all as specified and directed. 3 Supply only LED driver suitable for LED street light/flood light/flame proof light fitting for any make as per site requirement of capacity upto 110 watt, complete all as specified and directed. 4 Supply only LED driver suitable for LED street light/flood light/flame proof light fitting for any make as per site requirement of capacity120- 200 watt, complete all as specified and directed. 5 Material only for repair of gear assembly double drum winch type with pully and stainless steel wire rope to operate the symmetrically fiited lamps complete system of high mast lightupto 16 metre height and made it functional upto the entire satisfaction. Note : Cost of spare parts changed deemed to be included in the quoted rate. 6 Supply onlyin replacement energy saving Smart LED Street light of 120 Watt,Motion sensor based dimming , high pressure die cast alumuninum housing with seal toughned glass cover, minimum 110 lumen/wattcool/warm as per site requirement, operating voltage range 120 -220 Volts IP -66 surge protection minimum 5KV with flash indication, driver should be potted / CE certified/R cetificate and Driver efficiency 85%including making connection complete all as specifieid and directedMake:Havells/Philips/Goldmedal/Jaquar/Halonix 7 Supply onlyin replacement energy saving LED Street light of 90 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover, minimum 120 lumen/watt, cool/warm as per site requirement , operating voltage range 120 -220 Volts IP -66 surge protection minimum 5KV with flash indication, driver should be potted / CE certified/R cetificate and Driver efficiency 85%including making connection complete all as specifieid and directedMake:Havells/Philips/Goldmedal/Jaquar/Halonix 8 Supply and fixing street lightbracket made of shape in ornamental (designed as approved by engr-in Charge) GI pipe light grade 40mm mm dia of 2.5 metre longbend to shape for mounting LED street light fitting including MS clamps of suitable size for fixing of the bracket complete with nut bolts and washers complete all as specified and directed.Note:- Fixing of bracket on street pole at a height not more than 10 metre including dismantling of street light fitting and refixing the same after fixing of bracket with necessary T&P to be included in the quoted rate. 9 Supply only in replacement energy saving LED Flood light of 150 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover, light source should be multi LED SMDcolor temerature 6000 K , 500K(+-) system efficacy should be minimum 125 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66 THD Less than 10%surge protection minimum 5KV with flash indication, driver should be potted / CE cretified/R cetificate and Driver efficiency 85%including making connection complete all as specified and as directed. Make:Havells/Philips/Goldmedal/Jaquar. 10 Supply only in replacement energy saving LED Flood light of 100 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover, light source should be multi LED SMDcolor temerature 6000 K , 500K(+-) system efficacy should be minimum 125 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66 THD Less than 10%surge protection minimum 5KV with flash indication, driver should be potted / CE cretified/R cetificate and Driver efficiency 85%including making connection complete all as specified and as directed. Make:Havells/Philips/Goldmedal/Jaquar 11 Supply only in replacement energy saving LED Flood light of 30 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover, light source should be multi LED SMDcolor temerature 6000 K , 500K(+-) system efficacy should be minimum 125 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66 THD Less than 10%surge protection minimum 5KV with flash indication, driver should be potted / CE cretified/R cetificate and Driver efficiency 85%including making connection complete all as specified and as directed. Make:Havells/Philips/Goldmedal/Jaquar 12 Supply only in replacement energy saving LED Flood light of 50 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover, light source should be multi LED SMDcolor temerature 6000 K , 500K(+-) system efficacy should be minimum 125 lumen/watt cool/warm as per site requirement ,voltage range 120 -220 Volts IP -66 THD Less than 10%surge protection minimum 5KV with flash indication, driver should be potted / CE cretified/R cetificate and Driver efficiency 85%including making connection complete all as specified and as directed. Make:Havells/Philips/Goldmedal/Jaquar 13 Supply only in replacement energy saving decorative LED Flood light/Spot Light/Spike light of 9/10 Watt Capacity high pressure die cast alumuninum housing with seal toughned glass cover,cool/warm as per site requirement ,voltage range 120 -220 Volts IP -65including making connection complete all as specified and as directed. 14 Supply laying and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade 3.5 core 25sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Make:-Havells/Polycab/Paragon /KEINote:- (i) Excavation and earth work shall be measured and paid for seperatly. (ii) Thimble for cable termination on Junction box/panelas required should be included in this rate . 15 All as per item No 14 here-in-before but of size 16 Sqmm x 4 core 16 Supply and fixing in replacement FRLS PVC insulated copper conductor of Size 4.0 Sqmm 3 core for bollards etc with necessary connections including heavy duty UPVCconduit 25 mm complete including making the conduit underground all as specified and directed. Note : (i) One run of PVC 4 sqmm 3 core copper cable and one run of UPVC conduit 25 mm to be measured as One Running metre.(ii) PVC cable with UPVC conduit to be burried in ground exc. 15 cm but not exc. 30 cm deep.(iii)Excavation and earth work shall be deemed to be included in the quoted rate. 17 Supply and fix in replacementGI pipe light grade50 mm dia for cable protectionlaid under road/path/culvert or trenches, completeall as specified and directed. Make : JINDAL/ TATA/ KALINGA/ PRAKASH. 18 Excavation in trenchesn exc 1.5 metre wide and n exc 1.5 m in depth for laying of pipe/cableand getting out old unserviceablecable / pipein any type of soil including cutting of grass and bushes complete all as specified and directed. 19 Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. . 20 Removal of excavated soil surplus to the requirement to a distance n.exc 50 metre and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed. 21 Supply and Spread Natural Riddled soil in trenches for cushioning and covering to cable complete all as specified and directed by engineer in charge.Note: (i) Naturalsoil shall be riddled by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 cm and 15cm after laying of cable. This is then gently punned down to a depth of 10cm above the top of upper-most cable. (ii) For the purpose of measurement only punned thickness only will be considered for payment. 22 M&L for laying in trenchesprecast concrete cable coversClass LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified. 23 Supply only in replacement LED decorative post top clear light fitting 40 watt for 360 degree indirect light withIP 65 protection, resistant to impact and corrosion having glare free and better uniformity light, complete all as specifiedand directed. 24 Supply only in replacement PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 6.00 sqmm drawn through conduit pipe/bracket or along the wall/pole or as in trenchesincluding fixing on conduit/bracket and making connection to the fitting with over head line i.e connection to junction box fixed at bottom of pole complete all as specified and as directed. Make : Rallison/Finolex/Plaza/Gloster/KEI 25 Supply only in replacement PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 10.00 sqmm drawn through conduit pipe/bracket or along the wall/pole or as in trenchesincluding fixing on conduit/bracket and making connection to the fitting with over head line i.e connection to junction box fixed at bottom of pole complete all as specified and as directed. Make : Rallison/Finolex/Plaza/Gloster/KEI 26 Supply and fixing in replacement ofastronomicalTimer with outdoor enclosuredouble door,IP 54 Rated, inbuilt short circuit protection having class H insulation, contactor 65 Amps , 415V 3 phase, MCB TPN 10 kA astronomical time switchfor automatic ON & OFF panel with locking facility and mounting arrangements on PCC foundation at a height of 30 Cmand excavation for erecting complete with all connected items including disconnecting of LT electric ables and connecting with new panel and relevantwiringall as per site requirement for operating street/security lights, complete all as specified and directed.Make : Havells Cat No. IHXTS0912A /Legrand/ABB/Indoasian 27 Supply only in repairs pole mounting boxes made outof Sheet moulding compoundofinsidedimensions250 x 200 x 105 mm(HxWxD) with 3 phase strip and 1 neutral strip, side hinged door fixed to the base with hingessuitable for 4 wire system includingMCB SP 6 Amps 240 volts - 01 No, Shockproof and rustproof Cable entry from bottom and/or sides,100% weatherproof ,including Pole mounting arrangement like clamps, nuts etc,Maintenance-free complete all as specified and directedMake- Sintex or ISI marked. 28 Material and labourfor preparation of rusted surface of electric pole with brackets of any size/shape/type upto height max 8.0 metre , two pole structure, four pole structure and painting withaluminium paint and alternate colour of sky blue 3 strip and white paint2 strip of 30 cm height at bottom of the pole ( appx 1.5 metre ) including applying apex painting two coat on coping of the pole complete all as specified and directed. 29 M&L for streetlight bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubularpole including two Nos clamps made out 40mm X 6mm flat with suitable nuts, washerand bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed . 30 Supply and fixing in replacementof unserviceable LT Feeder Pillar Box out door type 1.1 KV made out of MS CRCA sheet of size 3.15 mmthickhaving 4 Nos Aluminiumbus barof size 200 Amps for phase and 100 Amps for neutralfixed on LT 8 Nos insulatorsof size 0.60Mx0.45M X 0.45Mwith 04 legs made out of MS angle 50X50X5 mm & 0.75 Mtr in length/Height with PCC foundation , locking arrangements, front and back opening, including danger notice board with skull & bone monogram & indicating 1100 volts danger boardand incoming and out going connections and testing on completion, complete all as specified and directed. 31 Material and labour Fiber reinforced plastic Fencing of height 1.8 mtr including gates ,footing legs of height 600 mm for cover of HT Panels ,Transformers, as per decided by Engineer in charge . 32 Material and labour, brick work with fly ashbricks straight or curved on plan exceeding 6m mean radius, builtin cemenmt mortar (1:6), complete all as specified and directed. 33 M & L for PCC 1:3:6 type B-0(12.5 mm graded stone agg ) as in coping of Transformer Platform including necessary form work complete all as specified and directed. 34 Supply only in replacement Galvanized steel flexible conduit with PVC Coating 20 mm dia normal size all as specified and directed . 35 Supply onlyin replacement Steel wire reinforced flexible UPVC ConduitGland 25 mm dia outside diameter all as specified and directed .Make-Precision/Astral/Polycab 36 Supply onlyin replacement Steel wire reinforced flexible UPVC ConduitGland 32 mm dia outside diameter all as specified and directed .Make-Precision/Astral/Polycab 37 Supply only in replacementDanger notice board of size 150 mm x 200 mm made of Sheet moulding compound/fiber reinforced plastic, 1.6 mm thick suitable for 415 V,Low Voltage installation all as specified and directed . 38 Supply only in replacement Danger notice board of size 200 mm x 250 mm made ofSheet moulding compound/fiber reinforced plastic, 1.6 mm thicksuitable for 11000 V,High Voltage installation all as specified and directed . 39 Material and labour for boring hole under road/pavement/hardstanding by trenchless technology using ultrasound technique & necessary machine for inserting HDPE100 mm size dia. HDPE Pipe 100 mm to be included in quoted rate complete all as speciofied and directed. 40 Supply & laying of UG cable XLPE insulated armouredheavy duty elect cable with stranded aluminiumconductor 1100 volts grade cross section area 240 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable thimbles, glands, nuts and bolts etc including removing/takingout damaged XLPE cable complete all as specified and directed. Make: Havells/Finolex/Plaza/KEINote: Exacavation and earthwork will be measured and paid seprately. 41 All as per item No. 40 here-in-beforebut of cross sectional area 120 Sqmm, 3.5 core. 42 All as per item No. 40 here-in-before but of cross sectional area 95 Sqmm, 3.5 core. 43 Supply and fixing in repair ACB 4 pole , 415 V with thermal magnetic release (manual drawout type) of capacity 630 Amps, 50 kA suitable for existing panels complete all as specified 44 M&L for RCC Cable route indicator showing LT Cable 440V with danger symbol and route of cable with arrow made ofprefabricated factory manufactured embossed letter in RCC indicator , eliptical shape at top and rectangular shape at bottom ,750mm long ,75 mm thickness embossed letterpainted in blue Colour with two coats of synthetic enamel yellowpaintduly embedded in PCC 1:2:4 type B1block (0.45x0.45x0.45) metreincluding earth work by removing damaged route indicator complete all as directed and specified. 45 Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 10 to 16 Sq mm complete all as specified and as directed.Make : Denson/M-seal/Raychem 46 All as per item No 45 here-in-before but for 25 Sqmm to 50 Sqmm 47 All as per item No 45 here-in-before but for 70 Sqmm to 120 Sqmm 48 All as per item No 45 here-in-before but for 150 Sqmm to 240 Sqmm 49 All as per item No 45 here-in-before but for 300 Sqmm to 400 Sqmm 50 M&Lfor Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles,earth pit ,including provision of necessary form work, finishing even and smoothwithout using extra cement includingapplying exterioremulsion paint (apex) complete all as specified and as directed by Engr-in-Charge. 51 M & L Plain Cement Concrete 1:3:6 type C2 using 40mm graded stone aggregate as in road cutting filling, foundation, fencing post , struts etc. complete all as specified and directed by Engr - in Charge. 52 Supply and erecting hot deep galvanised Octagonal pole 7 metre long, top dia 70mm, bottom dia 130mm having sheet thickness 3mm, base plate 225 mm x 225mm x 12 mm (LxBxT), Grade IS 2062 as per IS:5986:2017 latest, Hot dip Galvanised, as per IS:4759 latest: 610 g/m2, Door opening: 500 mm height from base plate, Size:90 mm x 500 mm with Gasket for clear access toMCB, Switches, cables, etc, pad lock with key, including junction box for electrical connections and equipment for wiring, circuit breakers, and other electrical components to house within the pole, for ensuring easy maintenance and installation of cables and suitable connector four pole including Suitable foundation with J type four Bolts, Nuts per bolt - 4 nos.,Washers - 4 nos.bolt size M 24x750,including hot dip galvanized single arm design bracket not more than 1.5 metre length for mounting street light fitting with suitable fixing accessories with 2.5 Sqmm 3 Core copper cablefrom light fitting to bottom of the connector including 3 phase and neutral connecting connector, Earthing terminals on the base of the pole, for lightning and electrical protection by using 12 mm dia SS Bolts of suitable length, including necessary earth work (excavation, PCC & welding work) for erecting pole including dismantling and lifting the existing RCC/GI pole with bracket and light fitting complete all as specified and directed.Make of Pole: L&T/Bajaj/BHEL/Jindal India) LimitedNote:- Hot deep galvanised Octagonal pole 7 metre long, Erecting of pole & transporting to the site, earth work, PCC 1:3:6 type C 1 using 20 mm graded crushed stone ggregate, welding, Junction box, MCB 1.5 to 2 Amp,bracket for fixing street light fitting, 2.5 Sqmm copper cable 3 core from light to junction box to be included in the quoted rate. 53 Supply and fix in replacement energy saving Smart LED Street light of 120 Watt,Motion sensor based dimming , high pressure die cast alumuninum housing with seal toughned glass cover, minimum 110 lumen/wattcool/warm as per site requirement, operating voltage range 120 -220 Volts IP -66 surge protection minimum 5KV with flash indication, driver should be potted / CE certified/R cetificate and Driver efficiency 85%including making connection complete all as specifieid and directedMake:Havells/Philips/Goldmedal/Jaquar/Halonix 54 Labour and transportation for cable fault detection machine upto the site, whenever required for detecting fault in LT XLPE faulty cable of 1100 volts grade layied under ground/floor/road etc. Note:- (i). The contactor shall arrange Fault locating equipment at site on receipt of telephone call from JE E/M / Engineer-in-Charge within time of Max. 6 hours for locating and rectification of fault other wise he is liable for the penalty of 500/- Per hrs in any type of delay.(ii). Excavation and earthwork involved up to 2 Metre length and 2mtr deep along the route of cablefor locating LT cable fault for taking out/ relaying of LT XLPE cable of any size/specification shall deemed to be included in the item rate.(iii). LT straight through outdoor / indoor type/ end terminal joint shall be measured and paid for seprately under the respective item of contract. 55 Supply and replacement of MCCB 400Amp rating,4-pole 415V, breaking capacity 50 KA, Adjustable & fixed magnetic setting type. Make: Havells/C&S/Schneider 56 Supply and replacement of MCCB 350Amp rating,4-pole 415V, breaking capacity 50 KA, Adjustable & fixed magnetic setting type. Make: Havells/C&S/Schneider 57 Supply and replacement of MCCB 250Amp rating,4-pole 415V, breaking capacity 36KA, Adjustable & fixed magnetic setting type. Make: Havells/C&S/Schneider 58 Supply and replacement of MCCB 200 Amp rating,4-pole 415V, breaking capacity 25 KA, Adjustable & fixed magnetic setting type. Make: Havells/C&S/Schneider 59 Supply and replacement of MCCB 160 Amp rating,4-pole 415V, breaking capacity 25KA, Adjustable & fixed magnetic setting type. Make: Havells/C&S/Schneider 60 Supply and fix in replacement of Precast (Factory Manufactured) Earthing pit of size450 mm x 450 mm x 450 mm withwall thickness 50 mm with Mortar design precast Pit cover , made withRCC including taking down old pit cover ,earthwork complete all as specified. Make-OM Precast/Dagar Tiles/AC Construction/Venus/Any other Precast RCC manufacturer 61 Supply and fixing in replacement of FRLS PVC insulated copper conductor of Size 2.5 Sqmm 3 corefor bollards with necessary connections drawn in heavy duty UPVC conduite 25 mm complete all as specified and directed.Note:- (i) One run of PVC 3 core copper cable and One run of UPVC conduit 25 mm to be measured as one RM. (ii)PVC cable with UPVC conduit to be burried in ground exc. 15 cm but not exc. 30 cm deep.(iii)Excavation and earth work shall be deemed to be included in the quoted rate. 62 Supply and fixing in repair of Automatic transformer switch (ATS), 4 pole 415 Volts with inbuilt time delay with outdoor/indoorenclosure as per site requirement of rating 400-630 Amps confirming IEC-60947-6-1 complete all as specified and directed. 63 Supply and fixflexible Stainless steelbraided hose pipe,flameproof , 20 mm dia , 300 mm length, Screwed male at both ends complete all as specified and directed . 64 Supply and fix flexible Stainless steel braided hose pipe,flameproof , 20 mm dia , 500 mm length, Screwed male at both ends complete all as specified and directed . 65 Supply and fix flexible Stainless steelbraided hose pipe,flameproof , 20 mm dia , 1000 mm length, Screwed male at both ends complete all as specified and directed . 66 Shifting of existing DG set of capacity 250 KVA with AMF panel by Mobile crane of suitable capacity within theBRD AF stndistance upto 1.5 KM including making PCC platform of suitable size in PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as per AGE E/M direction including earth work all as specified and directed.Note-Note-Dismantling of DG Set with AMF Panel by disconnectingLT Cables and earthing strip and refixing amf panel and connecting the same with all suitable materials to be included in the above quoted rates. 67 Shifting ofexistingDG set of capacity 30 KVA with AMF panel by Mobilecrane of suitable capacityto a distance upto1.5 KM including making PCC platform of suitable size in PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as per AGE E/M direction including earth work all as specified and directed.Note-Dismantling of DG Set with AMF Panel by disconnectingLT Cables and earthing strip and refixing amf panel and connecting the same with all suitable materials to be included in the above quoted rates. 68 S&F in replacement of flameproof LED high efficiency round high bay light fitting 150 watt in PDC housing,with thermal management in multiple optics and equipped with IP 65 protection, with impact and corrosion resistant complete with driver, Lamp and FLP Cable gland ¾” -02 Nos complete all as specified and directed. 69 Supply and fix cable jointing kit for 1.1 KV grade cable for end termination ,cold shrink type complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Aluminium conductor cable of size 10 to 16 Sq mm complete all as specified and as directed.Make : Denson/M-seal/Raychem 70 All as per item No 69 here-in-before but for 25 Sqmm to 50 Sqmm 71 All as per item No 69 here-in-before butfor 70 Sqmm to 120 Sqmm 72 All as per item No 69 here-in-before butfor 150 Sqmm to 240 Sqmm 73 Note :-Amount of credit ofRs. 87600.00for retrieved materials is mentioned in Schedule of Creditof tender documents in pdf form which will be deducted offline while acceptance of tender.

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail