Tender For Construction Of New 100 Bedded Girls Hostel With Various Work At Khelgaon District Udaipur (Raj.)
Tender Value
3.80 Crore
Estimated cost
Bid Submission
25 Aug 2025
0 days left
EMD
7.61 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
udaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of New 100 Bedded Girls Hostel With Various Work At Khelgaon District Udaipur (Raj.)
BOQ
| Sl. No. | Item Description |
| 1 | Surfacedressingoftheground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. And lift up to 1.5 Mtr. |
| 2 | lift up to 1.5 Mtr. |
| 3 | Earthworkinexcavationby mechanical means (Hydraulic Excavator) manual means in foundation trenches or drains (not exceeding1.5minwidthor10sum onplan)includingdressingofsides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposalofsurplusexcavatedsoilas directed with in a lead of 50 meter.All kinds of soils |
| 4 | Providingandlayinginposition cementconcreteincludingcuring, compaction etc. complete in specified grade excluding the costof centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand:8gradedstoneaggregate40mm nominal size). |
| 5 | Filling available excavated earth (excluding rock) in trenches plinth sideoffoundationetc.inlayersnot exceeding 20 cm in depth consolidation each deposited layer by rammingand wateringincludinglead up to 50 mtr and with all lift. |
| 6 | Providingandlayinginposition specifiedgradeof cementconcrete for allRCCstructuralelementsupto plinth level including curing, compaction,finishingwithrendering in cement sand mortar 1:3 (1 cement: 3coarsesand)andmakinggoodthe jointsandcostofplastizers(if required)excludingthe costof centering, shuttering and reinforcement.M25 grade Design Mix |
| 7 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 8 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE- CONSTRUCTIONAL Anti termite treatmentasperIS6313partIIIas amended from time to time and creating a continuous chemical barrier underandaroundthecolumnpits, walltrenches,basementexcavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints,overthetopsurfaceof consolidated earth of which aproch is tobelaidsurroundingofpipesand conduits etc. complete as per specification (Plinth floor area only shallbemeasuredforpaymentand excluding the cost of chemicalemulsion) . |
| 9 | Providingandlayinginposition specified grade of cement concrete for all RCC structural elements upto plinth level includingcuring, compaction, finishing with rendering in cement sandmortar1:3(1cement:3coarse sand) and making good the joints and cost of plastizers( if required) excludingthecostofcentering, shuttering and reinforcement.M20 grade Nominal Mix |
| 10 | Providingandlayinginposition specifiedgradeof cementconcrete for RCC structural elements upto floor fivelevelincludingcuring, compaction,finishingwithrendering in cement sand mortar 1:3 (1 cement: 3coarsesand)andmakinggoodthe jointsandcostofplastizers(if required)excludingthecostof centering, shuttering and reinforcement forWalls(any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M25 grade Design Mix |
| 11 | Providingandlayinginposition specifiedgradeof cementconcrete for RCC structural elements upto floor fivelevelincludingcuring, compaction,finishingwithrendering in cement sand mortar 1:3 (1 cement: 3coarsesand)andmakinggoodthe jointsandcostofplastizers(if required)excludingthe costof centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to15º,landings,balconies,shelves, chajjas,lintels,bands,plainwindows sills,staircasesandspiralstaircases etc.M25 grade Design Mix |
| 12 | CenteringandShutteringwith plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings, strap beam, raft , bases of columns etc. |
| 13 | Centering& shutteringwithplywood or steel sheets including strutting, propping bracing both ways with steel props andremovalofformworkfor upto floor five level for :Suspendedfloors,roofs,landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 14 | --Do-- Columns,pillars,postsandstruts etc. |
| 15 | Providing and fabricating reinforcementforR.C.C.work including straightening, cutting, bending,placinginpositionand binding (including cost of binding wire)allcompleteuptofloorthree level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 16 | RandomRubblestonemasonrywith hard stone in superstructure above plinth level and upto five levelabove 30cm. thick walls in :CementMortar1:6(1-Cement:6- |
| 17 | Random Rubble stone masonry for withhardstonein foundationand plinthinCementSandmortarabove 30 CM thick wall in:CementMortar1:6(1-Cement:6- |
| 18 | Random rubble dry stone Kharanja under floor. |
| 19 | BrickworkwithF.P.S.bricksofclass designation75insuperstructure above plinth level upto floor V level in all shapes and sizes in :Cementmortar1:6(1cement:6 coarse sand) |
| 20 | Half brick masonry in Superstructure , aboveplinthleveluptofloorV level using bricks of designation 75 Cementmortar1:4(1cement:4coarse sand) |
| 21 | Addextraproviding andplacingin position2Nos.,6mmØM.S.bar at everythird courseofhalfbrickmasonry. |
| 22 | Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Sand or other approved stone50mm thick. |
| 23 | Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Kota stone 25 to 30mm thick. |
| 24 | Extra over item for machine cut both side polished stone is used. |
| 25 | Providing and fixing Granite stone slab mirror polished and machine edgecutinwalls,pillars,steps, Shelves, Sills Counters, Floors etc. 15- 18 mm thick laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement:3coarsesand)jointingwithwhite cement mortar 1:2 (1white cement : 2 marbledust)withpigmenttomatch the shade of the marble slab including grinding, rubbingand polishing complete. South (Red) Above 3601Cm2 Slabs |
| 26 | Providing and fixing Marble stone flooring table rubbed, 15- 18 mm thickover20mm(Av.)thickbaseof CM1:4(1cement:4coarsesand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigmenttomatchtheshadeofthe marbleslabincludinggrinding, rubbing and polishing complete.ORProviding and fixing stoneslabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves,Sillsetc.laidon12mm(Av.) thickbaseofCM1:3(1cement:3 coarsesand)jointingwithwhite cement mortar 1:2 (1white cement : 2 marbledust)withpigmenttomatch the shade of the marble slab including grinding, rubbingand polishing complete.Rajnagar 1stquality/Ageriawith lightspots.Above 3601 Cm2 Slabs |
| 27 | Extraforprovidingedgemouldingto 15-18mmthickmarble/Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. completeas per design approved by Engineer-in- Charge. |
| 28 | Marble work Half Edge moulding |
| 29 | Granite/Kota Stone WorkHalf Edge moulding |
| 30 | Providing and fixing Ist quality ceramicglazedwalltilesconforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in allcolours, shades except burgundy,bottlegreen,blackofany size asapproved byEngineer in charge in skiriting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand)andjointingwithgrey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. |
| 31 | Finishing with neat white cement(punning). |
| 32 | Providing and laying Ceramic MAT floortiles (thicknesstobespecified bythemanufacturer)of1stquality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,FumeRedBrownofanysize, laidon20mmthick bedofcement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mixedwithpigmentofmatching shade complete. |
| 33 | P & F1st qualityVitrifiedPorcelain Polishedtilesonfloor,skirtingand stepsetc.indifferentsizes(thickness to bespecifiedbymanufactuer)with waterabsortionlessthan0.08%and conformingtoIS15622ofapproved makeinallcolourandshade, laid with20mmthickCM1 :4 including grountingthejointswithwhite cement and matching pigment etc complete. size 600 mm X 600 mm |
| 34 | Providing& fixing door, window, chowkhatsandotherframes, includingantitermitetreatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixedwithM.S.bolt5mmdia50mm longdulyembeddedincement concrete M-15 grade : Sal wood Grade - I. |
| 35 | Providing and fixing fully panelled/partly panelled/double leaf shutterframefordoorsasper approveddesignanddrawingswith approved ordinary C.P./ oxidised steel fittings as per Annexure - \"A\" and width of styles& top railsof 100mm andlockrailswidthof150mmand bottom rails of 200mm width includingteakwoodbeadingofsize 19mmx12mmonbothfaces complete : 35 mm thick Nigeria wood |
| 36 | Providing and fixing fully panelled/partlypanelleddoubleleaf shutters frame for windows and ventilators as per approved design and drawings withapprovedsteelfittings as per Annexure ‘A’ and width of styles, bottom and top rails75mm including intermediaterails50mmwide, beadingof25mmx15mmsizeonboth faces : 30 mm thickNigeria wood grade I |
| 37 | Providing and fixing wood panelling or panellingandglazinginpanelledor panelledandglazedshuttersfor doors,windowsand clerestory windows(Areaofopeningforpanel inserts excluding portion inside groovesorrebatestobemeasured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick |
| 38 | Nigeria wood Grade I |
| 39 | 5 mm float glass |
| 40 | Extra for providing other type of fittings as mention in annexure A ( asapproved by EI) : Brass fittings |
| 41 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings completeasperannexure\"A\" :35 mmthick.CommercialVeneerboth side |
| 42 | Extra for providing external lipping with2nd classteakwoodbattens6 mmminimumdepthonalledgesof shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 43 | Steel work in built up tubular trusses including cutting,hoisting(height upto 10 m)fixing in position and applyingaprimingcoatofapproved steelprimer,weldedandbolted including special shaped washers etc. complete.Hotfinishedweldedtype tubes. |
| 44 | Providing and fixing T-iron frames for doors, windows and ventilators of mildsteelTee-sections,jointsmitred and welded with 15x3 mm lugs 10cm longembeddedincementconcrete blocks15x10x10cmof1:3:6(1 cement:3coarsesand:6graded stone aggregate 20 mm nominal size) orwithwoodenplugsandscrewsor rawlplugsandscrewsorwithfixing clips or with bolts and nuts as require includingfixing of necessary butt hinges and screws and applying a primingcoatofapprovedsteel primer. |
| 45 | Providingandfixinginposition collapsible steel shutters with verticalM.S.Channels20x10x2mmand bracketwithflatirondiagonals20x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements insideandoutsidestoppers,handles etc. as per specification including applyingaprimingcoatofapproved steelprimer.(Tobemeasuredand paid as per outer dimension). |
| 46 | Providing and fixing stainless steel railing made of Hollow tubes, channels,platesetc.,including welding, grinding, buffing, polishing andmakingcurvature(wherever required)andfittingthesamewith necessary stainless steel nuts and boltscomplete,i/cfixingtherailing with necessary accessories & stainless steeldashfasteners,stainlesssteel bolts etc., of required size, on the top ofthefloororthesideofwaistslab with suitable arrangement as per approval of Engineer-in-charge, (for paymentpurposeonlyweightof stainlesssteelmembersshallbe considered excluding fixing accessoriessuchasnuts,bolts, fasteners etc.). Grade 304 |
| 47 | ProvidingandfixingM.S.sheet1mm thick single leaf door shutter in angle ironframe35x35x5mmsuitabilly diagonallybracedwith25x3mmflat iron above and below lock rail of size 50x5mmbeadingextraincludingall fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 48 | Providing and fixing steel glazed doors windows andventilatorshuttersof standard rolled steel section joints mitred and welded with steellugs 13x3mm, 10cm. long embedded in cementconcreteblock15x10x10cm. of 1:3:6 (1cement: 3 coarse sand : 6 graded stoneaggregate 20mm nominalsize)orwithwoodenplugs andscrewsorrawl plugsand screws with fixing clips or with bolts and nuts asrequiredincluding providingand fixingof plain glasspanes4mmthick withcooperglazingclipsandspecial metal sash putty of approved make or metalbeadingwithscrewscomplete including priming coat of approval steel primer, excluding the cost of metalbeadingandotherfitting except necessary hinges of pivots steel handles peg stay etc. as required:Partlyfixedandpartlyopenable[fixed area not to exceed 33%] |
| 49 | Supplying and fixing fixed wire gauge of14meshx24gaugetothemetal frame of rolled section by metal beading20x3mm with suitable screw at not exceeding 150mm distance. |
| 50 | ProvidingandfixingSquarebarsor other flat welded to window, ventilatiors etc. |
| 51 | 10mm Bar 0.78 Kg/Rmt. |
| 52 | Providing and fixing concertina coil fencing with required dia 610 mm (having15nos.roundper6metre length)upto3mheightofwallwith existingangleiron\"Y\"shapedplaced2.4mor3.00mapartandwith9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GIbarbedwiretiedtoangleironall complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Springcore(2.5mmthick) wireofhightensilestrengthof165 kg/sq.mmwithtape(0.52mmthick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) |
| 53 | Providing and fixing of double leaf steelshutterforcupboard,theSqm frameismadeofpressedsteelISI section80x25mmx1.25mmthick with 1.00 mm MS sheet to spot weldedincludingholdfastsof 15x3mm, MS oxidized fittings such as butthinges,slidingdoorsbolts, handles, tower bolts and twin peg etc completeincludingapplyingpriming coatofapprovedsteelprimerofred oxide zinc chromate andspray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge |
| 54 | qty |
| 55 | Providing and fixing steel gate, grating, and grills made of angles, tees, squarebars,flats,orblackpipewith holdfastandfittingscompleteasper designanddrawingincludingcutting weldingandfabricationwithpriming coat of red oxide |
| 56 | Extra if square, rectangular hollow tubelar sections are used or grill madeby flats only |
| 57 | Providinggola75x75mmincement concrete1:2:4(1cement:2 coarse sand:4stoneaggregate10mmand down gauge)including finishingwith cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 58 | Painting top of roofs with bitumen of approvedqualityat17kgper 10 sum impregnatedwithacoat ofcoarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete:Withresidualtypepetroleum bitumen of penetration 80/100 |
| 59 | Providing and laying brick kharanja onroofswithcementmortar1:4(1 cement:4coarsesand)mixedwith 2% integral water proofing compound insquarepattern75mmto100mm thick average |
| 60 | Fillingofsunkportionofroofwith earthenpotsofrequiredheight includingfillingvoidswith1:3:6light concrete,usingbrickbats complete levellinganddressingthesurfaceby 50mm thick cement concrete 1:2:4 as per specification. |
| 61 | Providingandlayingwaterproofing treatmentinsunkenportionofWCs, bathroometc.,by applyingcement slurry mixed with water proofing cement compound consisting of applying :a)[email protected]/sqmmixedwithwater proffing cement [email protected] kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. |
| 62 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7Kg/Sqm. (1.40Kg of VG-40 (30/40)gradeand0.30Kg/Sqm.Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 63 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or Lhooks,boltsandnuts8mm diameterwithbitumenandG.I. limpet washers orwith G.I. limpet washers filledwithwhite leadand including a coat of approved steel primerandtwocoats ofapproved paint onoverlapping ofsheets complete(uptoanypitchin horizontal/ vertical orcurved surfaces) excludingthecostof purlins,raftersandtrussesand includingcuttingtosizeandshape whenever required. 0.63 mm thick withzinccoatingnotlessthan275 |
| 64 | Kotastoneslab flooring25 mmthick over 20 mm (average) thickbase laid overandjointedwithgreycement slurrymixedwithpigmenttomatch theshadeoftheslabincluding rubbingand polishingcomplete with base of cement mortar 1 : 4 (1 cement:4coarsesand)Forareaof each slab from 2001 to 5000 Sq.Cm |
| 65 | RoughChiseldressedKotastone35 mmthickflooringof approvedshade setinpatternover20mmthickbase ofcementmortar1:6(1cement:6 coarsesand)andpointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : |
| 66 | Chequerredprecastcementconcrete tiles 22 mm thick in footpath & courtyardjointedwithneatcement slurrymixedwithpigmenttomatch theshadeoftilesincluding rubbing and cleaning etc. complete on 20 mm thickbedofcementmortar1:4(1 cement:4coarsesand)Darkshade using ordinary cement. |
| 67 | Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc. complete fine finish:20mm thick |
| 68 | Plasteronnew surfaceonwallsin cement sand mortar 1:6 including racking of joint etc. complete finefinish : |
| 69 | Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc. complete fine finish:25mm thick |
| 70 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) |
| 71 | Extraforliningoutplasterto imitate stone or concrete blockswalling |
| 72 | Making of Drip course (Tapaka) in cementsandmortar1:6widthupto40 mm and 10 mm thick as per approved design |
| 73 | Making grooves as per design in plaster 10mm to 20mm wide |
| 74 | Providingand applyingwhitecement based putty over plastered surface to prepare the surface even and smooth complete.New Plastered Surface (three or more |
| 75 | Finishing wall with water proofing cementpaintofapprovedbrandand manufacture and or required shade to giveanevenshadeincludingallscaffolding |
| 76 | Wall painting with plasticemulsion paint of approved brand and manufacturetogiveanevenshade including all scaffolding:Two or more coats on new workincluding prepartion of base |
| 77 | Painting exterior surface of Wall with 100% acrylic exterior paint of approvedbrandandmanufactureto give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc completeinallrespectincluding scaffolding and safety provision |
| 78 | Paintingwithsyntheticenamelpaint ofapprovedbrandandmanufacture togive an even shade :Two or more coats on new work |
| 79 | French sprit polishing:Two or more coats on new work including a coat of wood filler. |
| 80 | ProvidingandFixingChikenwire meshatthejointofmasonry members/ R.C.C. Members with Nailscomplete in all respect. |
| 81 | Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm |
| 82 | Rebarring work in old R.C.C structures includingmakingboreholetoadjust requiredbardiameterandfilling a goodqualityfillertoprovideatensil strengthasperrequirementandfix theBartothesactionincludingcost of bars. |
| 83 | 12 mm bar |
| 84 | 16 mm bar |
| 85 | 20 mm bar |
| 86 | Providingandfixingexpansionjoint board for building RCC column beams, walls,slabofPolyethylenefoamof density30to35Kg/m3ofArmour Board. |
| 87 | Supplyingandprovidingoftwo components poly sulphide sealant containingsolidcontents,confirming to standard specificationand approvedcompatibleprimer,for priming vertical faces prior to applicationofpolysulphidesealant including all labour charges for sealing of expansion joints after drill mixing of twocomponentssealingcompound. Cleaning and preparation of expansion joint using wire brush sand paperingwith emery paper and filing withsuitablemechanicalmeans.The work includes racking and cleaning of joints, sticking, debonding tape on bottomofjoint,applyingprimeron edges,usingmaskingtapeonedges, providingofsealantandremovalof masking tape immediately after providing sealant in joint. |
| 88 | To vertical joint between RCC columns,bricks&stonemasonryin size 40 mm width and 12 mm depth, includingprovidingbackupmaterial (Thermocol foam) if required. |
| 89 | Tojointsinflooring,asperdrawing withfirstlayerofpolysulphide sealantinsize20mmwidthand10 mmdepthoverPEFoamandthen providingpolyethylenefoambackup rod25mmdiasizeandfinally providinganotherlayerofpoly sulphide sealant in size 20 mm width and10mmdepthoverP.E.backup rod asper application procedureanddirection of Engineer-in-charge. |
| 90 | Providing and fixing 150 mm wide sheetcoveringoverexpansionjoints with iron screws as per design to match the colour / shade of wall treatment. |
| 91 | Providingandlayingdamp-proof course with cement concrete grade M 150(1:2:4)mortarpreparedwith 1% solution of water-proof compound complete as per specification .50mm thick. |
| 92 | P & F Indian type white glazed vitreouschina1stqualityW.C.orissa pan(IS:2556Mark)with100mm vitreouschinaPorStrapincluding cutting and making good the wall and floor: |
| 93 | Size 580x440 mm |
| 94 | P&FEuropeantypewhiteglazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor |
| 95 | P&FwaterclosetSeatCoverswith brass hinges complete :SolidPVC(IS2548marked)grade-IBlack for EWC. |
| 96 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittingsC.I.bracketsdulypainted,brassball cockwithball(IS:1703mark) complete including cutting and making good the wall:PVC with PVC bend as per IS : 7231. |
| 97 | P&FWVCWashbasin(Istquality IS:2556 Mark) of approved make withC.I.bracketsdulypainted1No.15 mmC.P.Pillarcock(IS:8934Mark) & 32mmC.P.brasswastecouplingof approved make, P.V.C Waste pipe withPVCnut32mmcomplete includingcutting&makinggoodthe wall : |
| 98 | KITCHEN & LAB. SINKS:P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chainwithrubberplug,40mmG.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approvedmakeas perEngineer-in- charge with large waste coupling. Overallsize(inches)=24x18x8, Bowl size(inches) = 20x16x8 |
| 99 | P&FBevellededgeMirror/mirror with teak wood lipping around of special glass of approved make as per directionof Engineer-in-charge complete with 6mm thick commercial plybasefixedtowoodenscrews& washers. |
| 100 | P & F Gratingof approvedquality/make: Stainless Steel Sheet size 125mm dia. |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778:2007code)havingthermal stabilityforhot&coldwatersupply includingall CPVCplain& brass threadedfittingsi/cfixingthepipe withclampsat1.00mspacing.This includesjointingofpipes&fittings withonestepCPVCsolventcement andthecostofcuttingchasesand makinggoodthesameincluding testing of joints complete as per directionofEngineerinCharge. (Concealedworkincludingcutting chases and making good the walls |
| 102 | 15 mm dia nominal bore B class |
| 103 | 25 mm dia nominal bore B class |
| 104 | 32 mm dia nominal bore B class |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778:2007code)havingthermal stabilityforhot&coldwatersupply includingall CPVCplain& brass threadedfittings,thisincluded jointingofpipes&fittingswithone step CPVC solvent cement , trenching refilling&testingofjointscomplete as per direction of Engineer in Charge. (External work). |
| 106 | 15 mm dia nominal bore B class |
| 107 | 25 mm dia nominal bore B class |
| 108 | 32 mm dia nominal bore B class |
| 109 | S&F G.I/. Union ISI Marked In G.I. Pipe lineasrequiredcompleteinallrespect of size. |
| 110 | 15 mm dia nominal bore |
| 111 | 25 mm dia nominal bore |
| 112 | 32 mm dia nominal bore |
| 113 | 50 mm dia nominal bore |
| 114 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: |
| 115 | C.P. Brass bib cock,15mm nominalbore. |
| 116 | P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: |
| 117 | C.P. Brass 15mm nominal bore. |
| 118 | C.P.BrassConcealedStopCock15mm. |
| 119 | P & F Inlet Connection (Angle Valves) Superiorquality,ofapprovedmake, forWashbasin,Gyseretc.C.P.Inlet connection 15mm.Brass (IS : 8931 marked)with37cmlongpipeand |
| 120 | P & F Full way valve (IS : 778 mark orwheel valve of approved make |
| 121 | Gun-metal 15 mm dia nominal bore |
| 122 | Gun-metal 25 mm dia nominal bore |
| 123 | Gun-metal 32 mm dia nominal bore |
| 124 | Gun-metal 50 mm dia nominal bore |
| 125 | P & F PVC Storage Tank ISI Marked (IS: 12701) indicating the BIS license No), of approvedmakewith cover, 25mm dia1MlongG.I.over-flowpipe& 25 Cm.longwashoutpipewithplug& socket,includingmakingconnection etc., complete of approved design: |
| 126 | 1000 litres capacity. |
| 127 | 750 litres capacity. |
| 128 | Providing&Laying C.C.1:5:10 (Stone aggregate40mmnominalsize)upto haunches of S.W. pipesincluding 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe) |
| 129 | 150 mm dia S.W. pipe |
| 130 | around 160mm rigid PVC pipe |
| 131 | Providing, Laying & Jointing R.C.C. classNP-2Non-Pressurepipes(IS: 458mark) of approved make with collars, jointedwith C.M.1:2 or havingSpigotandsocketendswith flexible rubber rings joint including testing of joints etc. complete : |
| 132 | P&FrigidPVCpipefittings(IS:4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 133 | Coppler |
| 134 | 110 mm dia |
| 135 | Plain Tee |
| 136 | 110 mm dia |
| 137 | 75 mm |
| 138 | Door Y |
| 139 | 110 mm dia |
| 140 | 75 mm |
| 141 | Bend 87.5 |
| 142 | 110 mm dia |
| 143 | 75 mm |
| 144 | Plain Floor Trap |
| 145 | 110 mm dia |
| 146 | Pipe Clip |
| 147 | 110 mm dia |
| 148 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ringand lubricant. |
| 149 | 75 mm dia |
| 150 | 110 mm dia |
| 151 | 160 mm dia |
| 152 | Construction of manhole in all type of soilinnersize90X60Cm.300mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finishedwithfloating neat cement, 50mm thick M-15 grade C.C. flooring, makingchannels,80mmthickstone slabcoveringwith40mmthickM-15 grade C.C. flooring, Cement cover with frameof 450mmdia, earthwork etc. complete as per design including disposalofsurplusearthwithin50 mtr.lead. Depth up to 0.5 M |
| 153 | Constructionofsoakage well inall typeofsoilwith300mmthickdry masonry,topandbottom300mm courseinCM1:6,80mmthickstone slab,jointing ofslabinCM 1:3, Ralthal,Kharanja,40mmthickM-15 grade C.C flooring , earthwork complete as per approveddrawing includingdisposalofearthwithina lead of 50 mtr.:Size300Cm.diaoutside&240Cm. depth. |
| 154 | Making of hole (width up to 150 mm) inR.C.C.slab/wall/beamsbypower drivendrillingmachinecompleteas per direction of EI |
| 155 | AddextraifR.C.Cslabofdesigned thickness & reinforcement is provided onmanholeinplaceofstoneslab( Actual area of R.C.C slab to bemeasured). |
| 156 | qty |
| 157 | Random Rubble stone masonry for withhardstonein foundationand plinthinCementSandmortarabove 30 CM thick wall in:CementMortar1:4(1-Cement:4- |
| 158 | qty |
| 159 | qty |
| 160 | qty |
| 161 | Finishingwithneatcement punning)on wall tiles |
| 162 | Providingandlayinginposition specifiedgradeof cementconcrete for RCC structural elements upto floor fivelevelincludingcuring, compaction,finishingwithrendering in cement sand mortar 1:3 (1 cement: 3coarsesand)andmakinggoodthe jointsandcostofplastizers(if required)excludingthe costof centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to15º,landings,balconies,shelves, chajjas,lintels,bands,plainwindows sills,staircasesandspiralstaircases etc.M20 grade Design Mix |
| 163 | Providing and fabricating reinforcementforR.C.C.work including straightening, cutting, bending,placinginpositionand binding (including cost of binding wire)allcompleteupto floorfive level.Thermo-mechanically Treated bars |
| 164 | 5.39@ 50 Kg./Cum. |
| 165 | ConstructionOfTubeWellupto 100mtr depth and above in all type of rocks by DTH system and over burden toaccommodatecasingpipeof followinf sizesin alltypesofsoil and over burdens including lowering of casing pipes but excluding cost of casing pipes as per IS:2800(Part I & II) 1979 specificationstheworkwould be completed after obtaining sand free water. the tube well should have throughout bore as pere nominal dia. ofcasingpipe(sitetobeverifiedby approved geologist):150mm Dia nominal bore. |
| 166 | Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) ofgrade Fe410 of following sizes at siteof work.150 mm Nominal bore of pipe |
| 167 | S&FtubewellcoverofM.S.Sheet (6mm thick) with nuts and bolts complete for casing size 150 mm dia |
| 168 | S & F M.S. clamp set of 50x 6 mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 169 | Providing&FixingofHDPEpipeISI mark(IS:4984/95)for watersupply (suitable for submersible & jet pump) with required fittings |
| 170 | for vertical installation 63 mm OD 6 kg/ cm2 |
| 171 | Supply of strainer pipesmade of ERWM.S.blackpipeISImarkoffollowing sizes atthe siteof work including required size of slotting as per IS:8110 1985. |
| 172 | Wiring of light point/fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopper conductor1.1kVgrade and1.5sq. mmnominalsizeFRPVCinsulated unsheathedflexiblecopperearth conductor1.1kVgrade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped GalvanizedModularBoxwithearth terminal, 10A Modular switch,Modularfaceplatewithgrid plate,3pinceilingrose/Holder/3 way connector, screws,making connections,testingetc.asrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheet\"s&Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parametersofproduct/workrefer Annexure \"A\" attached with this BSR |
| 173 | Short point (up to 3 mtr.) |
| 174 | Medium point (up to 6 mtr.) |
| 175 | Long point (up to 10 mtr..) |
| 176 | Wiringof3/5pin6amp.Lightplug pointwith1.5sq.mmnominalsize FRPVCinsulatedunsheathedflexible copperconductor1.1kVgrade and1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopper earthconductor1.1kVgrade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit& it\"sISI marked (IS:3419-1988)accessories, Hot DippedGalvanized Modularboxof1.2 mmthickwith earth terminal, 10 A modularswitch, 3/5 pin6 A modularsocket,Modularfaceplate withgridplate,screws,making connections,testingetc.asrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheet\"s&Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parametersofproduct/workrefer Annexure \"A\" attached with this BSR |
| 177 | On board |
| 178 | Medium point (up to 6 mtr.) |
| 179 | Long point (up to 10 mtr..) |
| 180 | Supplyingandfixingofpowerplug pointwithModularaccessoriesas perPWDspecificationforelectrical Works, on hotdipped galvanized modularboxof1.2mmthickwith earthing terminal/connector on surfaceorinrecessedwithsuitable sizeofmodularfaceplacewithgrid plate and cover plate including cost of ISImarkedmodular16amp.Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc.asrequired.Forspecificationof WiringaccessoriesreferChapter E- 07related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 181 | Providing & Fixing of following modularaccessoriesasperPWD specificationforelectricalWorks, made out of unbreakable and fire retardantverginpolycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,makingconnections,testing etc.asrequired. Foradditional technical parameters of product /work refer Annexure \"A\" attached with |
| 182 | Blanking plate |
| 183 | Providing&Fixingofmodulartype120WStepFanregulator duly ISI marked(IS11037:1984)withCM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonatewithbrassterminalsand captivescrews&silveralloycontact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,makingconnections,testing etc.asrequired. Foradditional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 184 | Supplying and drawing FRPVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130:2013of1.1kVgrade.Wireshould be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228for lowerwattloss,oxygen freeforlesschancesofoxidization, insulation PVC type A/C/D , flame retardantasperIS10810-53,better amperage rating as per IS:3961 part 5, inexisting surfaceorrecessedPVC/ MS conduit/casing capping making connectionswithCopperLugsof suitablesize,Ferrules,testingetc.as required.OEMMusthaveitsownin houseNABLlabsetupforalltesting facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 185 | 1 x 1.5 sq.mm |
| 186 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 187 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm |
| 188 | 2 x 6.0 sq. mm. + 1 x 4 sq. mm |
| 189 | 4 x 10.0 sq.mm |
| 190 | 1x 4.0 Sq.mm. |
| 191 | Providing&Fixingof Recessed/surface mountingheavy dutyhorizontaltypeDoubleDoor( Metal / Glazed )Distribution board withMetalendboxmadeoutfrom Galvanized steel / CRCA sheet not less then 1.2 mmthick conformingto IS- 8623-1 & 3 /IEC 61439- 1 & 3,powder painted complete with reversibledoor(fordoubledoorDB only)100 amp. insulated copper bus bar/shorting link , copper neutral link, copperearthlink,colorcoded interconnectingwireset ofsuitable rating and din bar,masking sheet, making internal DBterminations with copperlugs,Ferrules, detachable glandplate,includingmaking connections,testingetc.asrequired. OEM shall have submitNABL / CPRI / ERDAaccrediatedlabtypetest reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 192 | Glazed door (Three phase) IK-09 andIP-43 with Metal end box |
| 193 | Glazed door (single phase) IK-09 andIP-43 with Metal end box |
| 194 | Providing&Fixingof240/415VAC MCBwithpositiveisolationof10kA breaking capacity (B/ C/D tripping characteristic as per type of load and siterequirement)4KVimpulse withstandvoltage,ISImarkedIS 8828(1996) / conforming to IEC 608981 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase terminationcapacity of35sq.mm. , conductor line load reversibility , IP 20 contactprotectionandfittedin existing distributionboard/sheets, minimumelectricaloperation20,000 upto20Aratingand 10,000upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediatedlabtypetestreports & All as per pre approved by Engineer in charge. For additional technical parametersofproduct/workrefer Annexure \"A\" attached with this BSR |
| 195 | SinglepoleMCB(WithB/Ccurvetripping Characteristics) |
| 196 | Double pole MCB(With B/C curvetripping Characteristics) |
| 197 | 6 A to 32 A rating |
| 198 | 40 A rating |
| 199 | Four pole MCB (With B/C curvetripping Characteristics) |
| 200 | S&Ffollowingsizes(dia.)ofISI marked virgin material MMS ( IS:9537 P-III)PVCconduitalongwith ISI marked (IS:3419-1988)accessoriesas requiredinrecess including cutting the wall, covering conduit and making goodthesameasrequired. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 201 | 20 mm |
| 202 | 25 mm |
| 203 | Making of hole in wall (brick/stone) of requiredandplacingNP-2RCCpipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . |
| 204 | Up to 457 mm size |
| 205 | P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hookwith100mm lengthextended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 206 | Providing & Fixing of Heavy duty capacitorstart,copperwound Doubleballbearing 900/1400RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approvedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 207 | P&FofGravityLouvershutterof superior quality made out of frame of 18swgM.S.sheet&Louversmade from24swgMSSheet withenamel paint including cost of nuts, bolts, etc asreqd. Allasperpreapprovedby Engineer in charge.For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . |
| 208 | Providing&FixingofIP20SMDMid Power LED batten type integrated lightfixturemadefromPowder coatedExtrudedaluminium housing withinbuiltdriver ,Systemlumen efficacy≥110lm/Wattoutput, internalsurgeprotectionof2.5KV withShort&Opencircuitprotection,THD < 10% , P. F.≥0.95, CRI >80 , lifetime of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K(Asper ANSI Bin) , Maximum power consumptionshouldnotmorethan thespecifiedratingandFixtureshall beof BISstandardand trademark certificate ( T.C.). Manufactures Word Mark/Name Engraved/Embossing/ Screen printingon housing. OEM must have its own in house NABL lab setupforalltestingfacilitiesforLED fixtures.(LM79&LM80)certificate/ Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 209 | Providing&FixingofIP-20LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized nonyellowishDiffuserwith BIS complience2.5KV surge protected Isolateddriver,withShort &Open circuitprotection,havingefficiency> 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI>80,life time of minimum50000Burning Hours with,70% ofintial Lumenmaintanedtilllifeends , CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(AsperANSIBin),maximum power consumption should notmorethanthespecifiedrating andFixtureshallbeof BISstandard andtrade mark certificate ( T.C.). ManufacturesWordMark/Name Engraved/ Embossing/ Screen printing onhousing. |
| 210 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . |
| 211 | Surface Mounting(with extrudedalumn. Housing ) |
| 212 | Providing&FixingofIP20,2\"x2\"LED Surface/Recessed mountingMid power SMD type LED Light fixture not less than 50mm housingdepth made fromCRCAsheetsteelhousing,high purity / transmisivity UV stabilized Non-yellowishdiffuserforuniform light distribution. High efficiency with4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with lightfixture).Systemlumenefficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI>80, lifetimeof minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin),maximum power consumption should notmorethanthespecifiedrating andFixtureshallbeof BISstandard andtrade mark certificate ( T.C.). ManufacturesWordMark/Name Engraved/ Embossing/ Screen printing onhousing. |
| 213 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approvedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 214 | Surface Moutning |
| 215 | Providing& FixingofBEE Star rated copperwoundeddoubleballbearing capacitor start, aluminium body & Metallic bladeceiling fan Conforming to all the performance requirements laid down in IS 374:2019includingallamendments, asapplicable;&CarryBISlicensing (i.e. ISI marking) with down rod up to 80 cmwith secondarysupport safety cable ( steel rope) , cotter pin with 3 x1.5sq.mmpvcinsulatedflexiblecopperconductormakingconnection testing etc. as required. All as per pre approvedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 216 | Providing & Fixing ofextra down rod of15 mmdia .ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe includingcutting,threading,drilling, fixingquarterpinetcasreqd. Allas per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 217 | Providing&Fixingof 400 mmSweep BLDC technology Oscillating type Wall mounting/Pedestaltype fanswith Threespeed,ONand OFFposition, DoubleWallbearingwith frontand back120ormore ribsguard;Three no. blades,noiselevelshouldbe<= 75dB, includingfixingwithanchor bolts,makingconnectiontestingetc. as required. ( With Remote ) All as per preapprovedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 218 | Providing&Fixingof ofDoubleball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections,testingetc.asrequired. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 219 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolytic aluminium conductor confirming to IS 8130ofpurity>99.6%,round/flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existingRCC/Hume/Stoneware/ PVCpipe/openduct/cabletrench/ Cable tray(with cable tie) including testingetc.asrequiredoffollowing size. OEM must have it\"s own in house NABLaccrediatedLaboratoryfor testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 220 | Supplyingandmakingoneend terminationwithNickelplatedheavy dutybrasssinglecompressiongland (as per IS 12943-1990)) SIBG type consistingofCheckNut,Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut, heavydutyaluminiumlugs(asper IS 8309-1993)dulycrimpedwith crimping tool, PVC tape as perIS 8337-1976 of followingsizeof PVC insulated&PVCsheathed/XLPE aluminiumconductorcableof1100 voltgradeasrequired.Allasperpre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 221 | (e) Test certificatesfor confirming above standards from OEM is mandatory.Allasperpreapproved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . |
| 222 | Supply&Layingfollowingsizeearth wireinhorizontalorverticalrunin ground/surface/recessincluding riveting, soldering, saddles,making connectionwithGI/Cupuritypurity>95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 223 | Providing & Fixing of IK08, IP 66 protectedLEDStreetLightLuminaire onexisting bracket/pole.Fixture madeofpowdercoatedsinglepiece pressurediecastaluminummaterial withheatdissipationfinsonhousing with UV stabilized PC (UV stablization report submitted for UV cover )/Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The Systemefficacy>=125lm/wtand potteddriver &hasauniqueBISR number withInput Voltage AC 120 to270VACwithHighvoltageCutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency>85% ,THD(I)<10% Humidity 10% to 90% RH Working Temp -5C to 45C .driver current<750mA.Theluminaire shallbeBIS certified and Trade mark certified. Life Expectancy Equalormorethan 50000 burning hrs with Minimum 70% lumenmaintened,CRI>70andCCT 5700K+355K.Surgeprotectionshall be min ≥ 4 KV internal and min 10 KV externalinsidedrivercompartment. driver should be Phase to phaseprotection of 440 V for 4 Hrs. |
| 224 | LED Street Light fixture with Minimumlumen output 2450 lm |
| 225 | Providing & Fixing of Street light bracket made out from following size of \"B \"class , Medium classG.I. Pipe confirmingto IS: 1239 P- 1 ( 2004 ) withheavydutypoleclamp,Saddles suitablefastnersetc.asrequired.All asperpreapprovedbyEngineerin charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 226 | SITC of 3/4 polecurrentlimiting Moulded case circuitbreaker (MCCB) made of flame retardent & heat resistant materialhaving following currentrating,shortcircuit breaking capacity at440/415V,50Hz;O/L& S/C settings ,conforming toIS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability, designedforbothhorizontal& verticalmountingwithoutany adverseeffectonelectrical performance,suitableforoperation upto 55 degree and without derating upto40degree, pollutiondegree3, having positive isolation capability, push(test) to trip, trip time less then 10msunders/ccondition,Breaking capacity Ics = 100% Icu. U imp =8 KV, ratedinsulationvoltage690 V. provisionforUVR,shunttrip, earth faulttrip,doorinterlock,padlock& rotaryhandle,includingmaking connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediatedlabtypetestcertificate beforeexecutionAllasperpreapproved by Engineer in charge. For |
| 227 | 4 pole MCCB With Thermal Magneticrelease |
| 228 | up to 100 Amp , 25 kA, adjustable O/L& adjustable S/C setting, |
| 229 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC60028)busbarbymeansofSMC/ DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending,cuttinginrequiredshape and sizeand colour codingwith heat shrinkable PVC sleeves. All as per pre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 230 | [c) Interconnectionbetweenbusbar and switchgears /cable shall be rigidly supportedandmadeoutbyflexible copper wires(up to 63 amp ) and by solidbusbar (>63amp).control wiring willbecarriedout with1.5 Sq.mm,Earthwirewith2.5Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections ofcopperbus bar shall be dully tinned . Clearance betweenmainbusbarandrisers/ metalpartsshallbeatleast10mm additional to width of bus bar Bus bar isinsulatedbyHeatShrinkable sleeves.EarthandNeutralbusbar shall behalf of thesizeof phasebus bar.( Costof Busbar/ Flexible wire for Interconnection between Main busbarandSwitchgear istobePaid |
| 231 | (h) only outer surface area on all sides shall be measured & panel to be fabricatedonlyfromCPRIapproved fabricatoronly(CPRITestcertificates tobesubmitted)Allasperpre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 232 | Providing&Fixingof IS: 13875& IEC:61326 confirming LED Digital type (up to 500) V range Volt meter / Direct-Ammeter/ CToertated ammeter/Frequency meter/KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including makingconnectionbyPVCinsulated copperconductorwith PVCsleeves/ channeletc.asrequired. Allasper preapprovedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 233 | Threephase Ammeter withInbuiltSelector Switch |
| 234 | Providing&FixingofBISapproved Current Transformeras per PWD specificationforelectricalWorks,ISI marked as perIS 2705-1992/ conformingtoIEC60044-1,with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible fortestingandterminalconnection, with all necessarysupportin existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound asper IS 16227 with, AccuracyCl, CT ratio and burden as specified. ISF<=5, Cucrosssectionofsecondarywire 1.5sqmm(minimum),includingall necessary supportinexistingpanel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . |
| 235 | Ring type tape wound CT |
| 236 | Providing&Fixingofselectorswitch of 10 A for voltmeterusing high gradeengineeringmaterial to internationalstandardswithcam assemblyinsulation of glass filled polyamidewithhightrackingindex. Forreliableandstableelectricaland mechanical endurance double butt contactswithsilverbi-metalon copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations@300 cycles/hourandelectrically10,000 operations at 100% rated duty for 100 cycles/hourincludingmaking connectionetc. asrequired.Allas per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 237 | Voltage Between Phases with OFF ( 4Position ) |
| 238 | Providing & Fixing of110/220 V, unibodyLEDIndicating lamp IEC 60947with integral circuit, IP 65 abovepanel& IP20terminalblock, Approx.bodydiaforpanelnotless then 20 mm, length min. 50mm, front LEDcoverdiamin. 29mm,contact material phospher bronze for Led, PCBcontactsshallbeof brass(tin plated),impulse dielectrictestedfor2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 239 | Providing & Fixing of ISO certified companymadeonloadchangeover switch,fronthandleoperated,four pole415VasperPWDspecification for electrical Works conforming to IS/lEC60947-3:1999including connections, testingetc.as required.inthefollowingrating. Appropriate type test certificate / OEM test report shallbesubmitted. Allasperpre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 240 | Open execution type200Amp |
| 241 | Providing&Fixingofding dong/musicalchimebellasperPWD specificationforelectricalWorks, includingmakingconnectiontesting etc.asrequired.Allasperpre approvedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 242 | Supply& Fixingof DryPowder Agent (asperIS4308:2019),ABCtype Fire Extinguisher(Stored Pressuretype) conformingtoIS:15683:2018, Powder coated Internal & External SurfaceDeep drawn cylinder bodyof MildSteelCR2gradeconformingto IS:513, Squeeze grip Forgedbrass releasevalvewithInbuiltsafety releasedevice, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm longEPDMdischargetube,QRcode forProductTraceabilityincluding FixingonwallwithsuitableAnchor Fasteners as required of following capacity.TestCertificatesofallthe ParametersalongwithHydrotest& Burst test (For Cylinder Body) Certificatefrom OEM / External NABL AccrediatedLabistobesubmitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR |
| 243 | Providing & Fixing of Electrical insulatingrubbermattsasperPWD specificationforelectricalWorks,ISI marked confirming to IS: 15652 / 2006 withoneside antiskid abberation marks and pasting the mat with synthetic rubber adhesive as required.Allasperpreapprovedby Engineer in charge. For additional technical parametersof products/ work , refer Annexure\"A\" attachedwith this BSR . |
| 244 | SITC of Radial / mixed flow ISI marked waterandanti-corrosiveliquidfilled submersiblemotorpumpsets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler,forsafegaurdthecoupler. Theconstructionmaterialofmotor andpumpshouldmatchIS:8034: 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5starenergyefficiencylevelofBEE and mixed flow pump set should operate at 3 star energy level of BEE, accompainedbyvalid BEE certificate. MotorshouldbeIE2classasper IEC 60034-2-1: 2007, IEC60034-30: 2008,&IS12615:2011 withrequiredaccessoriesincludingmaking connection suitable for Bore well. The job includes labour part of lowering of riserpipeG.I./ H.D.P.E.withrope, cables & pump, installation of completefittingandaccessories, jointing of electrical cables up to Starter.Alllabour fortestingof submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submitNABL/ CPRI / ERDA accrediatedlab type |
| 245 | 100 mm diameter Submersible pump shallhavefollowingHPRating, phase,Headrange,Dischargerangerespectively. |
| 246 | SITCofSingleStage,watercooled, HighSpeed(2880RPM),Horizontal, Centrifugal,OpenwellSubmersible pumps set pre filled with coolent water and fitted with mechanical seal T/C Vs T/C, Thrust bearing shall be of carbon + S.S.The stator body of single phase pump shall be of SS and rest of allshallbeofcastiron.Allcasting parts shouldbe cathodelectro deposition (CED) coated and other construction material should be confirmingtoIS:14220:2018.The overall performance of pump shall confirm to BEE energy efficiency level of3star.ValidBEEcertificatefrom OEM must be submitted for the same.MotorshouldbeIE2classas perIEC60034-2-1:2007,IEC60034-30:2008,&IS12615:2011,includingmaking connection etc as required complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediatedlabtypetestcertificate before execution.All asper pre approvedbyEngineerincharge.For additional technical parameters of products/work,referAnnexure\"A\" attached with this BSR . |
| 247 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021for water supplysuitableforsubmersible& jet pump with required fittings ie socket, elbows,teeetc.completeinall respect.Allasperpreapprovedby Engineer in charge.For additional technical parametersof products/ work , refer Annexure\"A\" attached with this BSR . Vertical installation |
| 248 | SITC of ContactorOEM Fabricated DOL/Star-DeltaStarterpanelwith switchgear selection as per Type-2 Cordinatiom Chart andmade out from1.6mmthick powdercoated CRCAsheet,enclosurecomprisingof overloadprotectionrelay,short circuit & single phasing protection, IlluminatedON/OFF pushbuttons, ammeter, voltmeter, indicating lamps etc. suitableforfollowingrating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 249 | Providing&LayingofPolypropylene rope Confirming to IS:5175 for submersiblepumpoffollowingsizes. complete in all respect. All as per pre approvedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 250 | P/LayingISImarkedP.V.C.insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of1.1kVgrade.Wireshouldbemade from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVCtypeA/C/D,flameretardantas per IS 10810-53, better amperage ratingasperIS:3961 part5,existing pipe/opentrench/Cabletray/on surfaceincludingmakingconnection etc.asrequired.Foradditional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 251 | Providing&FixingofVertical(BEE5 starrated)/Horizontal(BEE3star rated) storage water heater with outer casing made of Engineering Plasticsheet(Upto25Ltr)/Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressureInnertank,GlassLine Coated , mineral filled heating element,stemtype,snapaction adjustable thermostat , Dual indicatinglampsInjected PUF insulation,MultiFunctionValveetc. asrequiredheldinpositionwith2/4 no.10/12mmanchorFastener,duly wired with3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductorand 16A/25A three pin plugtopwithPortableResidual CurrentDevice(PRCD),including making inlet, outlet Flexible alloy connection,testingetc.asrequired. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 252 | P&FinpositionframemadeoutofM.S. angle (riveted orwelded) finishedwithtwocoatsofredoxide and two coats enamel paint including cutting, welding, holes etc.of followingsizesasrequired.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 253 | Supply,Installation,Testingand ComissioningofIS:1475markedself containeddrinkingwatercoolerwith hermetically sealedcompressor,non CFC refrigerent suitable for operation on230V/1pH/50HzACsupply,Full stainlesssteel(SS304)body(0.8mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets andsuitabledrainagesystem completein all respectwithrequired height MS fabricated and Painted Angleironframe (Costofframeto be paid Extra )complete in all respect ofthefollowingcapacity. Allasper preapprovedbyEngineerincharge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 254 | Providing &Fixing of ACoperated heavy duty 230 /440 Volt power contactoras perPWD specification for electrical Works, ISI marked IS/IEC 60947-4-1:2000havingprovisionof mechanicalinterlocking,auxilary contacts,Dinrailmountingtype including making connections, testing etc. as required.All as per pre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 255 | 3polePowercontactors withfollowing AC 3 Rating |
| 256 | Up to 12 Amp |
| 257 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831- 1&2ORIEC:60831-1&2inexisting panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector(PSD)andshallhave dissipationfactorlessthan0.0025 at 50Hz,Operatinglosslessthan0.30 Watt per KVAR. Min over current capacity 1.8times ratedcurrent& peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V shouldlife expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc.asrequired.Allasperpre approvedbyEngineerincharge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 258 | Providing & Fixing of IP54 microprocessor based 3 CT’sforall 3 phase sensingcompensation power factorcorrectionrelaySize139mmx 139mm,OperatingVoltage415/440 V, IEC/ EN 61000-6-(2&4) having3CTsensing,sensitivityupto50milli amp secondary current , self analysing auto c/k setting according to targeted powerfactorsetting,therelayshall have digitdisplayunitfordisplayof real power factor, targeted power factor, lag/lead capacitor switching status, alarm output forunder current,overcurrent,insufficient compensation,communication interfacewithRS485, indicationof switching on units,auto/manual status, and shall have over load protection,novoltrelease,having multi parameterlikeKW, KVA, KVAR, RMS Value, step switching time 2 sec to1800sec.Lead &Lagparameters, meteringfacility and3 no.Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmaking coonection with 1.5 Sq.mmcopperwireetc.asrequired. All as per pre approved by Engineer incharge. For additional technical |
| 259 | 6 to 8 stage |
| 260 | SITCofROwatersystemwith Filterationstage=Particalatefilter- Membranelifeenhancerfilter- sediment filter - Pre carbon filter - RO membranefiler-Postcarbonfilter. Input power - 230 V AC , 50Hz , PercentageofRejectionTDS-90%or better having following fiturees (a) Double purification by RO with ESS or latest techonology with TDS indicator.(b)SpinweldedROmembrane Housing to prevent tempering (c)Push fit components for leak proof perfomance (d) Fully automatic operationwithautostart andauto off (e) SS/ ABSconstruction for corrosionfreelifespan(f)nEqually suitable for water from all bore wells , overhead storage tanks,water tankers and even municipal tapos (g) RO membraneFlushing-AutoFlush@ EveryStart.,EveryStopandevery One hours of working for one minute . completeinallrespect,with followingcapicity Make : Kent / EurekaFrobes/IonExchange/Electrolux / Voltas |
AI Tender Summary
Tender Timeline
Aug 14, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedAug 25, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 26, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender