| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge. In Cement mortar |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metre lead. For thickness of tiles above 25 mm and upto 40 mm |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. All kinds of soil |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - (a) 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 8 | (a) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 9 | (b) Suspended floors, roofs, landings, balconies and access platform. |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars |
| 11 | Half brick masonrywith Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in:Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 12 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:4 (1 cement: 4 coarse sand) |
| 13 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 14 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade using ordinary Cement |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade : — New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 16 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 17 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab upto 0.50 sqm |