Tender For Repairing/Replacement The Various Parts Of Multiparamonitor, Ecg Machine & Ventilatot Of Pediatric , Medicine , Tb & Chest & Surgery Department Of Smimer Hospital. Multipara Monitor Make:Contec Model: CMS 8000 Sr. No. 21030400047, 21030400114 , 21030400021, 21030400225 ,21030400133 Replacement Of Compatible Neonate SpO2 Probe. Compatible reusable Neonate Spo2 probe ytype with silicon wrap. Should be supplied with extension cable and y-type probe both. The neonate probe must be compatible with contec spo2 technology. Total Length=3meter approx. Spo2 Accuracy 70 to 100 % ± 3% Should be ISO/CE/BSI certified products only. One year comprehensive warranty The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty. No exceptions or excuses will be accepted in this regard.. 05 Paediatric (NICU) 2. Multipara Monitor Make:Comen Model:Star 8000 Sr. No.F7180313007B,F7180313008B, F7181227012B , F7181227013B Replacement Of Compatible Neonate SpO2 Probe Compatible reusable neonate Spo2 probe ytype soft rubber /silicon type with wrap. Must be Compatible with the above mentioned units Spo2 Technology. Length approx 3 mtr. Spo2 Accuracy 70 to 100 % ± 3% accuracy. Should be ISO/CE/BSI certified products only. One year comprehensive warranty. The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty: No exceptions or excuses will be accepted in this regard. 04 3. Neonatal Ventilator Make:Schiller India Model:Graphnet Adv. Sr.No.180940371081A1V, 18094038A1V Replacement Of Oxygen Sensor General Requirements : The oxygen sensor must be fully compatible with the Graphnet Advance ventilator (Schiller India) without requiring any modification to the existing unit. It must be suitable for continuous use in neonatal care settings, specifically in the NICU environment. The sensor must meet clinical accuracy standards suitable for neonatal patients. Technical Specifications: Type: Galvanic or Electrochemical (OEM or 02 OEM-equivalent with proven compatibility) Range: 0-100% O2 measurement capability Accuracy: ±2% of full scale or better Output Signal: Analog signal compatible with the Graphnet Advance interface Response Time: ≤ 15 seconds (T90) Operating Temperature Range: 0°C to 50°C Operating Humidity Range: 0% to 95% RH (noncondensing) Lifespan: Minimum operational life of 12 months under normal use conditions Compatibility & Compliance: Must be 100% compatible with Graphnet Advance ventilators supplied by Schiller India without the need for adapters, firmware updates, or calibration modifications. Must meet or exceed international standards for oxygen sensors used in critical care environments (e.g., ISO, CE marked). Warranty and Support : The oxygen sensor must be supplied with a one-year comprehensive warranty covering manufacturing defects, functional failures, and premature performance degradation. The supplier must offer prompt replacement in case of sensor failure within the warranty period. Packaging and Delivery: he sensor should be supplied individually sealed in sterile, protective packaging. Packaging should clearly display the manufacturing and expiration dates. 4. Multipara Monitor Model:Draeger Vista 120s Make:- Draeger Sr. No. V9SKE 0043, SISLE 0017 , SISLE 0010 Replacement Of Compatible reusable Clip Type/ Soft Rubber Adult SpO2 Probe. Compatible reusable Pediatric Spo2 probe soft rubber or clip type. Must be Compatible with the above mentioned units Spo2 Technology. Length approx 3 mtr. Spo2 Accuracy 70 to 100 % ± 3% accuracy. Should be ISO/CE/BIS/CDSCO certified products only. One year comprehensive warranty. The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty. No exceptions or excuses will be accepted in this regard. 03 Paediatric (PICU) 5. Multipara Monitor Model:Draeger Vista 120s Make:- Draeger Sr. No. SISLJ0044, SISLE0006 Compatible reusable Clip Type/ Soft Rubber Adult SpO2 Probe. Compatible reusable Pediatric Spo2 probe soft rubber or clip type. Must be Compatible with the above mentioned units Spo2 Technology. Cable Materialp TPU jacket Material & Latex Free. 02 Medicine (E4A ICU-1 nos.) Surgery (2BICU - 1 nos.) Length approx 3 mtr. Spo2 Accuracy 70 to 100 % ± 3% accuracy. Should be ISO/CE/BIS/CDSCO certified products only. One year comprehensive warranty. The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty. No exceptions or excuses will be accepted in this regard. Replacement of 5 lead ECG cable (adult) Sr.no. SISLJ0027 ,SISLJ0046 Compatible reusable 5 ECG limb lead grabber type wires with trunk cable. Should have grabber type limb wires. Should have detachable limb wires(preferable) so that each wire can be replaced as and when required. Leads should be color coded as per IEC All the lead wires must be encased in a lockable socket(if detachable) Must be defibrilator shock proof. Should be ISO/CE/BIS certified. The bidders are requested to kindly check the above machine on site before bidding. One year comprehensive warranty 02 Medicine (E5B) 6. Multipara Monitor Model: Vivid Vue 12 Make: BPL Medical Technologies Sr. No. RFMG1K1436 Replacement Of Compatible Neonate SpO2 Probe Compatible reusable Neonate Spo2 probe ytype with silicon wrap. Should be supplied with extension cable and ytype probe both. The neonate probe must be compatible with the above units spo2 technology. Total Length=3meter approx. Spo2 Accuracy 70 to 100 % ± 3% Should be ISO/CE/BSI certified products only. One year comprehensive warranty The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty. No exceptions or excuses will be accepted in this regard. 01 Pediatric (NICU) 7. Multipara Monitor Model: Oxyview Make: BPL Medical Technologies Sr. No. LYTAIF 1691 , LYTAIF 1692, LYTAIF 1694 Replacement Of Compatible Neonate SpO2 Probe Compatible reusable Neonate Spo2 probe ytype with silicon wrap. Should be supplied with extension cable and ytype probe both. 03 The neonate probe must be compatible with the above units spo2 technology. Total Length=3meter approx. Spo2 Accuracy 70 to 100 % ± 3% Should be ISO/CE/BSI certified The neonate probe must be compatible with the above units spo2 technology. Total Length=3meter approx. Spo2 Accuracy 70 to 100 % ± 3% Should be ISO/CE/BSI certified products only. One year comprehensive warranty The bidders are requested to visit the site to check the unit for confirming the SPO2 technology before bidding. The SpO2 probe, provided it is not physically damaged, shall be covered under the warranty. No exceptions or excuses will be accepted in this regard. 8. Multipara Monitor Model:C-50Make:COMEN Sr.noKD18031400813,KD180314009B,KD180314013B Replacement of Compatible Reusable NIBP cuff (Adult) Compatible reusable NIBP Cuff (adult) with male connector pin. Nylon, TPU material Size: 25-35cm Reusable with bladder Hose length-1 ft approx. Should be ISO/CE/BIS certified products only. 6 months comprehensive warranty. Replacement of 5 lead ECG cable (adult) Sr.no. KD180314008B , KD180314009B Compatible reusable 5 lead ECG limb lead wires (ADULT) with trunk cable. Should have grabber type limb wires. Should have detachable limb wires (preferable) so that each wires can be replaced as and when required. Leads should be color coded as per IEC. Should be ISO/CE/BIS certified products only. One year comprehensive warranty. 03 02 TB & Chest (RICU) 9. 3 Channel ECG Machine Make:Comen Model: CM300 Sr. No.30200119005 Replacement of Compatible 10 Lead ECG Patient cable Compatible reusable 3 Channel ECG Machine Make:Comen Model: CM300 Sr. No.30200119005 Replacement of Compatible 10 Lead ECG Patient cable Compatible reusable 10 lead banana pin type ECG patient cable. The ECG cable should be labeled with standard electrode names for easy identification. Should follow IEC (European Standard) color coding standards for ECG cable. The 10 lead ECG cable should be provided with junction for replacing/repairing lead wires easily (Preferable) Should be ISO/CE/BIS/FDA certified. Warranty: - One Year comprehensive Warranty. If the ECG cable sheath starts to worn out during the warranty period the same must be covered in the warranty and it will not be considered as physical damage. The bidders are requested to check the unit onsite for compatibility of theECG cable.