}

Tender For Supply Of Consumable Items Of Neurology Intervention Cath Lab, kota-Rajasthan

Government Medical College has published Tender For Supply Of Consumable Items Of Neurology Intervention Cath Lab. Submission Date for this Tender is 15-09-2025. Laboratory Equipment Tenders in kota Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

50688191
Tender For Supply Of Consumable Items Of Neurology Intervention Cath Lab
Tender
Indian
Rajasthan
Kota
15-09-2025

Tender Details

Tender For supply of Consumable Items Of Neurology Intervention Cath Lab , For The Procurementconsumable Items For Neurointervention Cath Lab , Puncture Needle For Vascular Access In Adults For Neuro Intervention Procedures 18 G/20G/22G , Short Introducer Sheeth For Adults • Size 4Fr • Should Be 10-11 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Short Introducer Sheeth For Adults • Size 5Fr • Should Be 10-11 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Short Introducer Sheeth For Adults • Size 6Fr • Should Be 10-11 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Short Introducer Sheeth For Adults • Size 7Fr • Should Be 10-24 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Short Introducer Sheeth For Adults • Size 8Fr • Should Be 10-11 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Short Introducer Sheeth For Adults • Size 9Fr And Above • Should Be 10-11 Cm • 0.025-To-0.038-Inch Guidewire Compatible • Kink Resistant • With Dilator –Hub Lock Mechanism To Prevent Its Backout During Insertion , Amplatz Catheter: • In Various Standard Lengths And Curves • 035-038 Compatible 100 Cm Long , Diagnostic Cerebral Angiography Catheter In Various Standard Curves:, Vtk, Sim 1, Sim2, Sim 3 4 French/5 French/6 French Sizes And Lengths (70Cm, 90Cm &100Cm). , Diagnostic Cerebral Angiography Catheter In Various Standard Curves: Headhunter 4 French/5 French/6 French Sizes And Lengths (70Cm, 90Cm &100Cm). , Diagnostic Cerebral Angiography Catheter In Various Standard Curves: Picard 4 French/5 French/6 French Sizes And Lengths (70Cm, 90Cm &100Cm). , Diagnostic Catheter For Spinal Angiography In Various Standard Curves: Cobra, Rc1, Rc2 4 French/5 French/6 French Sizes , Hydrophilic Diagnostic Guide Wire – Type (Regular Length, Regular Stiffness) • Must Be Available In 0.025, 0.032, 0.035- And 0.038-Inches Size • Should Have Super Elastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be 140-180 Cm Long , Hydrophilic Diagnostic Guide Wire – Type (Exchange Length) • Must Be Available In 0.025, 0.032, 0.035- And 0.038-Inches Size • Should Have Super Elastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be 260-300 Cm Long , Tuohy Borst Double With Side Arm (Haemostatic Double Y Connector) For Co-Axial/Triaxial Systems , Tuohy Borst With Side Arm-Haemostatic Y Connector , Disposable Luer Lock Syringe • Should Be Compitable With Cuanoacrylate. • Should Be Available In 1 C.C/2C.C/3C.C/5C.C/10 C.C/20 C.C/ 50C.C , Pressure Saline Bag 1000Ml , Pressure Infusion Reusable Bag 1000Ml , Long Introducer Sheeth 80/90/100Cm Dedicated For Neurovascular Intervention • Stainless Steel Braided • Should Be Available In 6Fr With 0.088 Inch •With Rounded Automatic Tip •Od 0.100 To 0.106 , Long Introducer Sheeth 80/90Cm Dedicated For Neurovascular Intervention • Stainless Steel Braided • Should Be Available In 6Fr With 0.088 Inch •With Rounded Automatic Tip , Long Introducer Sheeth 80/90Cm Dedicated For Neurovascular Intervention • Should Be Available In 6Fr With 0.091 Inch • With Rounded Automatic Tip • Od 2.77Mm • Distal Complaint Portion With 14.5 Cm Flex Segment And Rounded Edges , Long Introducer Sheeth 80/90Cm/95Cm Dedicated For Neurovascular Intervention • Stainless Steel Braided • Should Be Available In 7Fr With 0.090 Inch •With Rounded Automatic Tip , Long Introducer Sheeth 80/90Cm Dedicated For Neurovascular Intervention • Stainless Steel Braided • Should Be Available In 8Fr With 0.091 Inch •With Rounded Automatic Tip , Guiding Catheter For Neurovascular Intervention • Size 6Fr • 0.070,Inner Lumen •Length Should Be 100Cm/105Cm , Guiding Catheter For Neurovascular Intervention • In Various Standard Length • Size 7Fr • 0.074,Inner Lumen •Length Should Be 100Cm/105Cm , Intermediate Catheter For Neurovascular Intervention • Length 115/132 Cm • Available In All Size • Inner Lumen 0.071 , Distal Acess Catheter For Co-Axial Systems • Size 4Fr • 0.040/0.044/0.045 Inner Lumen •Length Should Be In Between 125Cm To 143Cm , Distal Acess Catheter For Co-Axial Systems • Size 5Fr • 0.053/0.055/0.058 Inner Lumen •Length Should Be In Between 115Cm To 132Cm , Distal Acess Catheter For Co-Axial Systems • In Various Standard Length • Size 6Fr • 0.060/0.070/ 0.072/0.071 Inner Lumen •Length Should Be In Between 105Cm To 132Cm] , Microcatheter For Aneurysm Coiling • Inner Lumen 0.065” • Two Markers For Coil Deployment • Should Be Compatible With 0.014 Micro Guidewire • Length Should Be 150Cm • Distal Shaft 1.7Fr , Microcatheter For Aneurysm Coiling:0.017” • Size And Length (Diameter)- Recommended 0.017” • Two Markers For Coil Deployment • Should Be Compatible With 0.014 Micro Guidewire • Length Should Be 150Cm , Microcatheter For Baby Sizes Nitinol Fd & Braided Stent:0.017” • Size And Length (Diameter)- Recommended 0.017” & 160Cm • O.D. 2.5F To 2.2F • Two Markers For Coil Deployment • Graded Shaft Stiffness With Soft Atraumatic Tip • Should Be Compatible With 0.014 Micro Guidewire , Microcatheter For Nitinol Fd Size And Length (Diameter)- Recommended 0.021” & 150 / 156Cm • O.D. 2.6F To 2.1F • Two Markers For Coil Deployment • Graded Shaft Stiffness With Soft Atraumatic Tip • Should Be Compatible With 0.014 Micro Guidewire , Microcatheter For Nitinol Fd Size And Length (Diameter)- Recommended 0.021” & 175 / 180Cm • O.D. 2.6F To 2.1F • Two Markers For Coil Deployment • Graded Shaft Stiffness With Soft Atraumatic Tip • Should Be Compatible With 0.014 Micro Guidewire , Microcatheter For Small Dia Cocr Fd Size And Length (Diameter)- Recommended 0.021” • O.D. 2.6F To 2.3F • Graded Shaft Stiffness With Soft Atraumatic Tip , Microcatheter For Cocr Fd • Id 0.027” • Straight 1 Tip Marker • Length 150Cm , Special Micro Guidwire With Torque Device For Use With Micro Catheters • Size 0.010” • Length 200 Cm , Special Micro Guidwire With Torque Device For Use With Micro Catheters • Size 0.012” • Straight And Pre Shaped , Special Micro Guidwire With Torque Device For Use With Micro Catheters • Size 0.014” • Length 215 Cm , Special Micro Guidwire (Exchange Length 260-300Cm) With Torque Device For Use With Micro Catheters • Size 0.012” , Special Micro Guidwire (Exchange Length 260-300Cm) With Torque Device For Use With Micro Catheters • Size 0.014” • Length 300 Cm , Thermomechenical Detachable 3-D Type / Helical Coils For Intracranial Aneurysm Treatment – Bare Platinum Coils , Thermal Detachable 3-D Type / Helical Coils For Intracranial Aneurysm Treatment – Bare Platinum Coils , Electrolytic Detachable 3-D Type / Helical Coils For Intracranial Aneurysm Treatment – Bare Platinum Coils , Electrolytic Detachable Tetrahedral Shape Coils For Intracranial Aneurysm Treatment – Bare Platinum Coils , Mechenical Detachable 3-D Type / Helical Coils For Intracranial Aneurysm Treatment – Bare Platinum Coils , Thermomechenical/ Thermal Detachable 3-D Type / Halical Coils For Intracranial Aneurysm Treatment – .012/.014 Coils For High Packing Density , Accessories For Detaching Coils Mechanical Detachment , Accessories For Detaching Coils Thermal Detachment , Accessories For Detaching Coils Thermomechanical Detachment , Accessories For Detaching Coils Electrolytic Detachment , Laser Cut Open Cell Intracranial Stents For Stent Assisted Coilling Of Aneurysn • Should Have Adaptive Cell Design • Should Be Available In Various Size And Diameter • Redio Opaque Markers • Having Alternete Row Of 12 Crown And 8 Crown , Laser Cut Close Cell Intracranial Stents For Stent Assisted Coilling Of Aneurysn • Should Have Close Cell Design • Should Be Available In Various Size And Diameter , Laser Cut Hybrid Cell Intracranial Stents For Stent Assisted Coilling Of Aneurysm • Should Have Close Cell Design • Should Be Available In Various Size And Diameter , Braided Intracranial Stents For Stent Assisted Aneurysm Coiling • Should Be Available In Various Size And Diameter , Braided Intracranial Stents For Stent Assisted Coilling Of Aneurysm • Should Be Available In Various Size And Diameter • Should Be In Combo With Compatible Catheter , Endoluminal Embolization Nitinol Fd Device •Baby Sizes • Compatible Through 0.017 Micro Catheter • Diameter 2.25Mm-3.25Mm • Length 10Mm-25Mm. • 48 Braided • Full Visibility, 9.0Mm Angulated Distal Lead Wire , Endoluminal Embolization Nitinol Fd Device • Compatible Through 0.021 Micro Catheter • Diameter 3.5Mm-4.75Mm • Length 15Mm-40Mm. • 48 Braided • Full Visibility, 9.0Mm Angulated Distal Lead Wire , Endoluminal Embolization Nitinol Fd Device • Compatible Through 0.027 Micro Catheter • Diameter 2.5Mm-6.0Mm • Length 10Mm-60Mm. , Endoluminal Embolization Cobalt Chromium Fd Device • 48 Wires With Cobalt Chromium Shell And Platinum Core • Compatible With 0.021 Microcatheters , Endoluminal Embolization Cobalt Chromium Fd Device • 48/64 Wires With Cobalt Chromium Shell And Platinum Core • Compatible With 0.027” Microcatheters , Intrasaccular Device For Treatment Of Aneurysms • Compitable With An 0.027 Microcatheter • Wires 128-144 • Nitinol Micro Breded Mesh • Platinum Core Wire For Visualization • Variable Size For Treatment Of Medium To Large Aneurysm , Intrasaccular Device Enabling Simultanoeus Coilling • 144 Wires -216 • Compitable With An 0.021/0.027 Microcatheter • Size 4/5/6/7/8Fr , Intrasaccular Device For Treatment Of Aneurysms • Shape Spharival To Cuboidal • Compitable With An 0.027 Microcatheter • Variable Size For Treatment Of Medium To Large Aneurysm • Hybrid Technology , Electrothermal Detachment For Intrasaccular Devices •Preloaded With Batteries With Output Voltage , Single Lumen Baloon Catheter For Intracranial Use • Compatible With 1214 Wire , Single Lumen Baloon Catheter For Intracranial Use • Compatible With 0.010 Wire , Single Lumen Baloon Catheter For Intracranial Use • Compatible With 0.014 Wire • Dmso Compatible , Double Lumen Occlusion Balloons • For Flow Modification/Assistance For Treatment Of Wide-Neck Intracranial Aneurysm Dmso Compatible • Sizes -7,9,12,15,20 All Length Should Be Available • Central Lumen Compatible With Intracranial Stent/Coil Deployment, Liquid Embolic Agent , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 1.2Fr , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Compatible With N-Butyl/Cynoacrylates • Flow Guided • Size 1.5Fr And 150-180 Cm Long • Should Be Compitable With 0.007/0.008/0.010 Microguidwire , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 2.7Fr/1.3Fr • Dmso Compatible , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 1.2Fr – With Detachable Tip , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 1.5Fr- With Detachable Tip , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 1.2Fr – With Detachable Tip (Should Be In Combo With Compatible Wire) , Super Selective High Flow Infusion Catheters - For Cerebral/ Spinal Avms • Size 1.5Fr – With Detachable Tip (Should Be In Combo With Compatible Wire) , Micro Guidwire With Torque Device For Avm • Size 0.007 , Micro Guidwire With Torque Device For Avm • Size 0.008 , Evoh (Ethylene Vinyl Alcohol) • 6&8 % Viscosity 1.5Ml , Evoh (Ethylene Vinyl Alcohol) • 12 Viscosity Available In 12 Centipoise Viscosity 1.5Ml , Evoh (Ethylene Vinyl Alcohol) • 18 Viscosity Available In 18 Centipoise Viscosity 1.5Ml , Evoh (Ethylene Vinyl Alcohol) • 34 Viscosity Available In 34 Centipoise Viscosity 1.5Ml , Poly Vinyl Alcohol (Pva) Particles For Pre-Operative Tumour Embolization , N-Butyl Cyanoacrylate (Nbca) • Compatible With Lipiodol As Radiopaque Contrast Agent For The Treatment Of Avm , Lyophilized Poppy Seeds Oil/Ethiodized Oil , Baloon Guiding Catheter • Size 7Fr 8Fr 9Fr , Large Bore Aspiration Catheter For Thrombectomy • 6F –0.060/0.068/ 0.070/0.071/0.072/0.074 Id •Length Should Be In Between 130Cm To 135Cm , Large Bore Aspiration Catheter For Thrombectomy •5F –0.055/0.058/ 0.060/ 0.062 Id •Length Should Be In Between 130Cm To 140Cm , Large Bore Aspiration Catheter For Thrombectomy •4F –0.043/0.046 Id •Length Should Be In Between 140Cm To 160Cm , Revasculization Device For Mechenical Thrombectomy For Flow Restoration In Acute Ischemic Stroke • Size 0.017 • Dia 3Mm, Length 20/32/40 , Revasculization Device For Mechenical Thrombectomy For Flow Restoration In Acute Ischemic Stroke • Size 0.017 • Dia 4Mm, Length 10/15/20/40/41 , Revasculization Device For Mechenical Thrombectomy For Acute Ischemic Stroke • Size 0.021 • Dia 6Mm, Length 30/37/40/50 , Revasculization Device For Mechenical Thrombectomy For Acute Ischemic Stroke • Size 0.027 • Dia 6Mm, Length 20/24/30/37/40/50 , Microcatheter For Mechanical Thrombectomy • Graded Shaft Stiffness With Soft Atraumatic Tip • Inner Lumen 0.017 , Microcatheter For Mechanical Thrombectomy • Graded Shaft Stiffness With Soft Atraumatic Tip • Inner Lumen 0.021 , Microcatheter For Mechanical Thrombectomy • Graded Shaft Stiffness With Soft Atraumatic Tip • Id 0.43 , Carotid Angiopalsty Balloon Catheter (Over The Wire/Rapid Exchange) • Should Have Hydrophilic Coating • Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , Carotid Self Expendable Stents • Should Be 0.018” Compatible • Should Be Over The Wire And Rapid Exchange (Otw/Rx) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Stents For Use In Carotid Stenting: Self Expandible, • Dual Layered With Micro Mesh Design • Nitinol Open Cell Stent With Pet Close Cell Mesh • Diameters: 6-10Mm & Lengths: 20, 30, 40 & 60Mm. , Distal Embolic Protection Device • Filter/Umbrella Types • Small Crossing Profile , Infalation Device With Analog Display , Connecting Tube Used With Thrombosuction •Tubing System Used With Thrombosuction Pump & Aspiration Catheters , Collection Canister Used With Thrombosuction Pump •Canister Used With Thrombosuction Pump , Thrombosuction Pump (Suction Machine) •For Thrombosuction Of Intracranial Thrombus

Key Value

Document Fees
INR 1000 /-
EMD
INR 648000.0 /-
Tender Value
INR 3.24 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail