| 1 | Annual Maintenance of 26 Nos. of WINDOW TYPE AIR CONDITIONER on monthly basis for 12 months i.e. total qty. of ACs (26 Nos. x 12 months=312 Nos. of maint.). This includes checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per month. Note: i) Cleaning and general maintenance ofACs shall have to be carried out as and when required. The frequency of this cleaning and Gen. maintenance shall be high in some places (dusty area) and may be low in some other places.This shall be carried out as per instruction of engineer incharge. ii) Supply of spares which are included in this schedule shall be used for maintenance of ACs as and when required. |
| 2 | Annual maintenance of 81 Nos. of SPLIT TYPE AIR CONDITIONER on monthly basis for 12 months i.e. total qty. of ACs (81 Nos. x 12 months=972 Nos. of maint.) including checking, servicing, repairing overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work and special conditions per machine per month. Note: i) Cleaning and general maintenance of ACs shall have to be carried out as and when required. The frequency of this cleaning and Gen. maintenance shall be high in some places (dusty area) and may be low in some other places. This shall be carried out as per instruction of engineer incharge. ii) Supply of spares which are included in this schedule shall be used for maintenance of ACs as and when required. |
| 3 | Annual maintenance of 5 Nos. of WATER COOLERS upto 300 litres on monthly basis for 12 months i.e. total qty. of Water Coolers (5 Nos. x 12 months=60 Nos. of maint.)including checking, servicing, repairing overhauling and painting as and when required (but at least twice in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per month. Note: Supply of spares which are included in this schedule shall be used for maintenance of coolers as and when required. |
| 4 | Annual maintenance of 3 Nos. of WATER COOLERS CUM PURIFIERS of Make Eureka Forbes / equivalent, Aquaguard Model: PSS120 UV / equivalent model of upto 120 litres / equivalent on monthly basis for 12 months i.e. total qty. of Water Coolers cum purifiers (3 Nos. x 12 months=36 Nos. of maint.) including checking, servicing, repairing, overhauling as and when required (but at least three times in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per month. Note: i) Painting (if required) once per year shall also be carried out by bidder as per direction of Engineer-In-Charge. ii) Supply of spares which are included in this schedule shall be used for maintenance of water coolers cum purifiers as and when required. |
| 5 | Annual Maintenance of 3 Nos. of DRYER of Air Compressor on monthly basis for 12 months i.e. total qty. of Dryers (3 Nos. x 12 months=36 Nos. of maint.)including checking, servicing, repairing, complete overhauling and painting as and when required (but complete overhauling at least twice in a year and painting once in a year) and attending breakdown calls within 24 hours including replacement of all spare parts as per scope of work & special conditions per machine per month. Note: i) Cleaning and general maintenenece ofDryers shall have to be carried out as and when required or as per direction of Engineer-In-Charge, ii) Supply of spares which are included in this schedule shall be used for maintenance of Dryers as and when required. |
| 6 | Installation/shifting of window type AC with supplying wooden frame, fixing screws, hardware materials cement, sand as required to fix the frame including cutting pockets etc. |
| 7 | Installation/shifting of split air conditioner with supplying al fixing materials, MS frame/pedestal for setting outdoor units as required to fix in dfferent locations |
| 8 | Repairing of Microprocessor unit in split / Window type air conditioner Make-VOLTAS/LG/SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge for 2.0 Ton Capacity |
| 9 | --do-- but for 1.5 Ton |
| 10 | Repairing of Indoor unit Blower motor of window / split type air conditioner of 1.5 / 2 ton in all respect. Note: The repaired indoor unit blower motors shall be accepted by UCIL only after successful trial run at our site. |
| 11 | Supply of new compressor of Rotary/ Reciprocatingof 1-Phase / 3-Phase (as per requirement at site) of power saving model Kirloskar / Carrier / Tecumseh / LG make for window type and split type air conditioner (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply. |
| 12 | --do-- but 1.5 ton compressor - Rotary |
| 13 | --do-- but 2.0 ton compressor - Rotary |
| 14 | --do-- but 1.5 ton compressor - Reciprocating |
| 15 | --do-- but 2.0 ton compressor - Reciprocating |
| 16 | --do-- but 3.0 ton compressor - Reciprocating, 415 volts3 Ph. |
| 17 | Supply of new compressor of 1-Phase / 3-Phase (as per requirement at site) of power saving model Kirloskar / Carrier / Tecumseh / LG make for water cooler of capacityupto 3500 litres(with proof of precurement from original manufacturer with Sl. No. etc.) inclusive of capilarry, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply. |
| 18 | Supply of Feron/Mefron-22 refrigerant in own certified cylinder & filling in machine |
| 19 | do but supply of Feron/Mefron-12 |
| 20 | --do-- but supply of 134 A |
| 21 | --do-- but supply of R-404 |
| 22 | --do-- but supply of R-410 |
| 23 | Supplyof capacitor Make-ASIAN/UNIVERSAL/HI-TECH as per direction of Engineer-in-charge |
| 24 | Supply of starting relay/contactor as per direction of Engineer-in-charge |
| 25 | Supply of Blower fan motor Make-FRAGMASTER/AMERICAN UNIVERSAL as per direction of Engineer-in-charge |
| 26 | Supply of Microprocessor unit of 1.5 Ton split air conditioner Make-VOLTAS/LG/ SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge |
| 27 | --do-- but of 2.0 Ton |
| 28 | Supply of Display / Sensor of PLC Kit |
| 29 | Supply of Brass Valve of Size: 5/8\" used in Split AC as per following: |
| 30 | --do-- but Size: 1/2\" |
| 31 | --do-- but Size: 1/4\" |
| 32 | Supply of Indoor Unit complete with Remote Controller for 2.0 Ton split AC of Make: Cruiser / Voltas / LG / Bluestar / Samsung |
| 33 | --do-- but for 1.5 Ton |
| 34 | Supply of the copper pipe of Size: 5/8\" suitable for Split AC |
| 35 | --do-- but of Size: 1/2\" |
| 36 | --do-- but of Size: 1/4\" |
| 37 | Supplyof louver with motors as per direction of Engineer-in-charge |
| 38 | Supply of front grills for Split A.C. as per direction of Engineer-in-charge |
| 39 | Supply of front grills for Window A.C. as per direction of Engineer-in-charge |
| 40 | Supplyof copper condensor for Split A.C. as per direction of Engineer-in-charge |
| 41 | Supplyof copper condensor for Window A.C. as per direction of Engineer-in-charge |
| 42 | Base tray of window AC for LG, Voltas, Local, Blue Star Make |
| 43 | Runner for split AC for 3.0 tons |
| 44 | Runner for split AC for 2.0 tons |
| 45 | Runner for split AC for 1.5 tons |
| 46 | Window A.C.fan blade |
| 47 | Split AC fan blade |
| 48 | Repairing of 2.0Ton reciprocating type compressure |
| 49 | Repairing of 1.5Ton reciprocating type compressure |
| 50 | Supply of new Scroll Compressor of3-Phase (as per requirement at site) of Capacity: 3.5 ton, BTU/Hr.: 36000 approx. of Model ZR40K3E-TFD-522AJQ, 3 Phase, 415 Volt, Suction Size: 20 mm, Discharge Size: 14 mm, Overall length: 420 mm, Overall width (diameter): 530 mm of Make: Emerson Copeland / Kirloskar / Danfoss for Dryer of Air Compressor (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. used gas-R22 |
| 51 | Supply and fixing of hot gas bypass valve |
| 52 | Supply and fixing of refrigerant gas filter/dryer |
| 53 | Supply and fixing of Solenoid with timer and socket . |
| 54 | Supply and fixing of thermister display with delay time relay |
| 55 | Supply of Axial fan 3 Ph/single phase |
| 56 | Supply of new compressor of 1.5 ton - Rotary/Reciprocating Inverter type of 1-Phase / 3-Phase (as per requirement at site) of power saving model VOLTAS/Kirloskar / Carrier / Tecumseh / LG make for window type and split type air conditioner (with proof of procurement from original manufacturer with Sl. No. etc.) inclusive of capillary, strainer, copper pipe etc. and its installation in place of defective compressor in the machine inclusive of dismantling, installation, gas charging with supply of gas, nitrogen flushing, washing etc. Note: The Compressor shall have to be approved by Engineer-In-Charge before supply. |
| 57 | Supply of Microprocessor unit & PCB board of inverter type of 1.5 Ton split air conditionercomplete set Make-VOLTAS/LG/ SAMSUNG / AJURE / LANCER as per direction of Engineer-in-charge |