Tender For Provision Of Type Vi Md Accommodation For Mes Cgos At Dehradun Cantt; 1 SCHEDULE A PART-I(BUILDING WORK) 2 Construction of Type VI MD Accn for MES CGOs on permanent specification (single storey) complete all as shown on drawing and specified. 3 Construction of servent Qtr complete all shown on drawing & specified 4 Construction of Garagecomplete all as shown on drawing & specified 5 SCHEDULE A PART II(Internal Water Supply) for details refer Sch A in pdf folder 6 SCHEDULE A PART III(Internal Electrification) for details refer Sch A in pdf folder 7 S&F Decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp B22 base with and including one No 9 watt LED bulb. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. 8 S&FBed side lamp fitting 360 degree flexible twisting/rotating LED type of capacity 2-3 watts including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. 9 S & Femergency LED 9 W B22 CDLBULB Cool Day Light complete all as specified and directed. 10 S&F sheet steelenclosure with 20 Amp modularsocket ,plug top and modularMCB SP 10 KA ( ready plug & play all-in-one device) complete all as specified by EIC. 11 S&F modular Telephone socket RJ11 complete with modular plate fitted on modular GI metal box of 1/2 module including frame of suitable size all as specified and directed 12 S&F of modular TV socket complete with modular plate including modular frame fitted on modular GI metal box of 1/2 module all as specified and directed 13 M&L for TV Wiring with Co axial RG-6 heavy duty PVC insulated, PVC sheathed cable having single strand of 0.7 mm dia taped in concealed PVC conduit suitable for television wiring including all necessary connections from terminal box to TV socket, drawn in and including separate concealed PVC conduit of suitable size complete all as directed.(Note :-Cost of conduit and cutting chases deemed to be included in quoted rates for this item) 14 M&L for Telephone Wiring with 0.5 mm dia FRLS-H, 2 pair PVC insulated annealed copper conductor, unarmored telephone cable concealed PVC conduit suitable for television wiring including all necessary connections from terminal box to socket, drawn in and including separate concealed PVC conduit of suitable size complete all asdirected. (Note :-Cost of conduit and cutting chases deemed to be included in quoted rates for this item) 15 S &F of 4 wayco axial cable splitter to distribute single cable TV into three out put work on 5-2500 MHz frequency complete all as specified and directed. 16 S&F 10 pair telephone DP box made out of mild steel duly painted complete all as specifed and directed 17 S&F of electric chimney with autoclean function 750mmx500mmx550mm (width) dimensions having suction power of inlets 1300 Cum/hrs, motor warrany 3 years with power onsumption 180W, 230V, 50Htz having 3 speed gesture movement in black coated CRCA material and to be installed with proper aluminium pipe suitable size length as recommended by manufacturers from electric chimney to outside of building complete all as specified and directed. 18 S&F vertical instant electric water heater with 3000 W power input & SS inner tank, capacity 3 ltr complete with all accessories such as safety valve, thermostate, NRV, fixing bolts, stainless steel braided connection piece 450mm long all as specified directed 19 SCHEDULE A PART IV (Road, Path & Hardstanding works) for details refer pdf folder 20 SCHEDULE A PART V(Sewage Disposal Works) for details refer pdf folder 21 M&L for construction of septic tank for 10 users type B with sub class B brick masonry wall, PCC in foundation floor, RCC cover slab, CI vent pipe, CI cowl, inlet and outlet pipe, RCC baffle wall and necessary excavation and earth work complete all as specified and shown on drawing. Note : Ref TD - 217, Sheet No 1/7 to 7/7 22 M&L for slakage wells comprising of excavation, in any type of soil, foundation in PCC walls of honey combed masonry with top ring of M25 concrete, RCC cover slab in M25 /SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 3.0 M effectivedepth complete all as specified and shown on drawing.Note : Ref TD-309, Sheet No 1/4 to 4/4 23 SCHEDULE A PART VI(External Water Supply works) for details refer pdf folder 24 M&L forconstruction of valve pit brick masonry builtincementmortar 1:6 valve pit of size 60 cm x 60 cm x 60 cm internal dimension includingbase foundation valve pit with PCC 1:4:8 type D2using 40 mm gradedstone aggregate of size 140x140 x20 cm depth andrendering10mm thick with cement mortar 1:4 on internal andexposed surface and pit cover with3mm thick MS sheet of size 1.0mx1.0m mtr and 40x40x5 mm angle iron framing with locking arrangementincludingpainting with two coat of synthetic enamel paint over a coat of red oxide primercomplete all as specified and shown on drwaing. 25 SCHEDULE A PART VII (Hot water supply) for details refer pdf folder 26 SCHEDULE A PART VIII (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 27 M& L for boring holes (manually) under road ,hard standing,without damaging surface for 40 mm dia GI pipe etc complete all as specified and directed. 28 S&F cable junction box (to be fixed on pole) with connection terminal , factory made of size not less than 205mmx255mmx112 mm 9 outside dimension) with IP66 protection made out of high quality thermoplastic poly corbonate having 4Nos of 1Sqmm terminal, weatherproof , meteric knockout for cable , outdoor type fixed to pole with MS clamp made of MS flat 40x3mm including 01 No MCB SP 6Amp fixed on din rail MCB shoul be covered by poly corbonate transparent cover all as specified and directed. 29 Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board ofsize out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.00 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening,and having provision for front and rear side opening with rubber beading, suitable size copper bus bar and mild steel cable glands for each cable to make it weather and vermin proof.double door hinged type,both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray paintedinternally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plaincement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out goingcomplete all as specified and comprising of following accessory :- INCOMINGMCCB 4 Pole, 63 Amps ,415 Volt of breaking capacity 16 KAFixed type- 02 Nos.Change Over 4 Pole, 63 Amps ,415 Volt of breaking capacity 25 KAwith Adjustable Thermal and Adjustable Magnetic- 01 Nos.OUTGOINGMCCB 4 pole 415 V 40 Amps 16 KA, Fixed type - 03 nosMCB SPN, 240 V, 6-32 Amps -03 NosVoltmeter (0-500) volts digital type with selector switch.-01 No, astronomical timer switch with auto ON/Off to street lightsAmpere Meter (0-200) Amperes, 96mm square, digital type, CT connected with suitable CTs and selector switch-)1 NoPhase indicator, LED type, each Set, Digital timer switch for automatic ONN/OFF street lights. 30 SCHEDULE A PART IX (Site Clearance and Development)