}

Tender For Electrical Work To Be Carried Out At Utility Centre, Delhi University Cooperative Society Bathroom And Stairs,University Of Delhi, Delhi-Delhi

Delhi University has published Tender For Electrical Work To Be Carried Out At Utility Centre, Delhi University Cooperative Society Bathroom And Stairs,University Of Delhi. Submission Date for this Tender is 26-08-2025. Road Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

50663566
Tender For Electrical Work To Be Carried Out At Utility Centre, Delhi University Cooperative Society Bathroom And Stairs,University Of Delhi
Tender
Indian
Delhi
Delhi
26-08-2025

Tender Details

Tender For Electrical Work To Be Carried Out At Utility Centre, Delhi University Cooperative Society Bathroom And Stairs,University Of Delhi; 1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 1 x 1.5 sq.mm 3 2 x 2.5 sq.mm 4 2 x 4 sq.mm 5 2 x 6 sq.mm 6 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B 7 S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. 6 Modules 8 3 Modules 9 6 Module 10 8 Modules 11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 12 5/6 amps switch 13 3 pin 5/6 amps socket outlet 14 15 /16 amps switch 15 6 pin 15/16 amp socket outlet 16 Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB C curve including connections, painting etc. as required. 17 Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 2 Nos. 3 pin 5/6A Modular socket outlet and 2 Nos. 5/6A modular switch, connections etc. as required. (for light plug to be used in non residential building) 18 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 amps 16 KA TP MCCB 19 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 20 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 21 Supplying and fixing of street light pole box of size 8x10 complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site. 22 Supplying/ installation/ testing and commissioning of 150 watts flood light LED fitting having suitable angle frame, complete with all accessories i/c having pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openig separate driver compartment with IP 66 protection and Impact resistance of IK07 with KV build in SPD i/c making connection as required. BVP 176 LED 162 NW FG WB 150W PSU (Philips /Equivalent) 23 S/F of singlebox type fitting complete with all accessories i/c making connection etc as reqd.i/c having 1 Nos 18 watts MAS LED tube 18W B2B 865 T8 in the existing fitting as required. TMC 501 1XT - LED 22W P3242 . (Philips/Equivalent) 24 S/F of double box type fitting complete with all accessories i/c making connection etc as reqd.i/c having 2 Nos 18 watts MAS LED tube 18W B2B 865 T8 in the existing fitting as required. TMC 502 2XT - LED 22W P3242 . (Philips/Equivalent) 25 S/F 18 watts MAS LED Tube having 2100 LM with 40000 burnign hours for the existing fitting i/c making connection as required. (2 years warranty should be provided. CAT No. MAS LED TUBE 18W 2100LM with 40000 burning hours 865 T8) (Philips or equivalent make) 26 Making provision for servicing/cleaningthe feeder pillar completely with air blower i/c checking all the connections, balancing the load, replacement of burnt thimbles i/c rubbing the corrosion i/c welding and painting the same with two or more coats as per site requirement 27 S/F DLP UPVC trunking compartment with cover clip on separates partition left right top internal angle, flat angle, raise function, flat function cover to body joints mosaic clip & support from mosaic isolation bracket 2 mm thick plastic. (Legrand) 105 mm X 50 mm with all accessories

Key Value

Document Fees
INR 500 /-
EMD
INR 11691.0 /-
Tender Value
INR 5.84 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail