Tender For Special Repair / Replacement Of Ht/Lt Oh Line To Ug Cable From Airport 2 Pole Structure To Kv 2, Gna Ground And Bso Yard From Cgra Feeder At Sma Varunapuri Under Ge (Nw) Vasco
Tender Value
74.85 Lakhs
Estimated cost
Bid Submission
09 Sep 2025
0 days left
EMD
1.37 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vasco → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair / Replacement Of Ht/Lt Oh Line To Ug Cable From Airport 2 Pole Structure To Kv 2, Gna Ground And Bso Yard From Cgra Feeder At Sma Varunapuri Under Ge (Nw) Vasco
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying & testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. |
| 2 | Supply and fix Cable jointing kit for 11 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. |
| 3 | Material and labour Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including dismantling old burnt cable joint termination complete all as specified and as directed. |
| 4 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard /Dense soil complete all as specified and as directed. |
| 5 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard rock soil complete all as specified and as directed. |
| 6 | Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 7 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 8 | Supply and laying galvanised tube light gradeISI marked of size 100 mm dia including all fittingsin trenches/fixed on pole/wall/floor or laid in positioncomplete all as specified and directed. |
| 9 | Material and labour for road cutting including necessary excavation 45 cm wide and90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable throughpipeafter laying /through the cable trenches will be fillingtop withMaterial and labour PCC 1:3:6 type C-1 using 20 mm grades stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm boulders 100 mm dia over filled and rammed earth to make good the disturbedsurface etc complete all as specified and directed. |
| 10 | Supply of 11 KV, 630A, 21 kA 3Sec, 3way SF6 Outdoor RMU – 2LBS + 1CB:Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery charger shall be provided in RMU. Design shall be side & rare cable termination with 3mm SS Gas Tank complete all as specified and as directed. |
| 11 | Supplying, installation, testing & commissioning of 11 kV, 630 Amps, STC 21kA for 3 Sec Outdoor Extensible 6-way SF6 gas insulated floor mounted with copper bus bar Ring Main Unit should consist of 02 (Two) Nos incoming Load Break Switch and 04 (Four) Nos outgoing Vacuum Circuit Breaker Motorized type having facility to connect to SCADA in future with Air Insulated PT Metering Panel and 4nos MFM in outgoing VCBs. All live parts, bus bars, VCB will be enclosed in robotically welded with 2 mm thick Stainless-steel tank, 2 mm GI enclosure (CRCA not feasible looking into corrosion proof requirements) filled with SF6 at 1.4 bar with IP class IP67, leak rate less than 0.1% and outer enclosure with IP54 protection and tested as per latest IEC 62271-200. HT compact switchgear shall be with fixed type VCB for 11 kV earth system 50Hz AC three phase including earth fault and over current protection and motorized spring charging mechanism for VCB. While refilling the SF6 gas the manometer should be able to show the pressure inside the Stainless-Steel tank with a dedicated gas topping up arrangement on the LV panel. The switchgear should be tested for Internal arc for both tank and cable box IAC AFLR (21kA-1 Sec) venting through bottom. The switchgear should be totally enclosed confirming to relevant IEC standard with fitting of protection relay with indicators as under. Note: The aboverate is inclusive of all the civil works for necessary foundation as per OEM recommended drawing. |
| 12 | S & F of cable path indicator of RCC floor mounted 4 feet 11KV Cable route marker endorsed with \"HT 11 KV UG Cable\" duly painted with red on Top & black on bottom portion and including PCC (1:2:4) for fixing type B2 complete all as specified & directed. made up of precast RCC (1:2:4) type B-0 (TMT bars 6 mm dia)using 12.5 mm graded stone aggregate complete all as specified and directed. Note - Cost of earth work & PCC included in the quoted rate. |
| 13 | Material and labour for taking down of unserviceable aluminium conductor steel reinforced (ACSR) of any description /size & in any position from existing HT poles or lines complete all as specified and as directed. |
| 14 | Material and labour for taking out of unserviceable insulators of any type and any position from HT poles complete all as specified and as directed. |
| 15 | Material and labour for taking down of existing unserviceable cross arms, mild steel channel or angle sections etc complete all as specified and as directed. |
| 16 | Supply and lay Double walled corrugated pipe (DWC ) confirming to IS14930 heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. Complete as specified and directed |
| 17 | Dismantling wood poles/ struts, any size19289 Dismantling wood poles/struts, any size Transporting to store and sacking complete all as specified and as directed. |
| 18 | Supply andlaying LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall including dismantling of existing cable of following sizes |
| 19 | (a)25 Sqmm 3.5 Core |
| 20 | (b)50 Sqmm 3.5 Core |
| 21 | (c)70 Sqmm 3.5 Core |
| 22 | (d)95 Sqmm 3.5 Core |
| 23 | (e)120 Sqmm 3.5 Core |
| 24 | Material and labour for DWC of pressure rating PN 6 (SDR 21) laid in trenches for cable protection complete all as specified and directed of following sizes:- |
| 25 | (a)40 mm dia |
| 26 | (b)90 mm dia |
| 27 | Supply and fix sheet moulding compound junction box (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including MS clamp with nut and bolt, one in Nos MCB SP 0.5 Amps including cable glandes - 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and directed.Note : MS clamp with nut and bolt will be measured and paid separately. |
| 28 | Material and labour Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 to 50 sqmm including dismantling old burnt cable joint termination complete all as specified and as directed. |
| 29 | Material and labour Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm including dismantling old burnt cable joint termination complete all as specified and as directed. |
AI Tender Summary
Tender Timeline
Aug 12, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedSep 09, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedSep 11, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender