Tender For Provision Of Wash Room Near Drill Square At Ota Under Ge Stm Chennai., chennai-Tamil Nadu

Military Engineer Services has published Tender For Provision Of Wash Room Near Drill Square At Ota Under Ge Stm Chennai.. Submission Date for this Tender is 02-09-2025. Toilet Bathroom Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50645221
Tender For Provision Of Wash Room Near Drill Square At Ota Under Ge Stm Chennai.
Tender
Indian
Tamil Nadu
Chennai
02-09-2025

Tender Details

Tender For Provision Of Wash Room Near Drill Square At Ota Under Ge Stm Chennai.; 1 Surface excavation n.exc 30 cm deep but averaging 15cm deep and getting out in hard dense soil complete all as specified and as directed. 2 Excavating in trenches, n.exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10sqm on plan and n exc 1.5m in depth and getting out in hard dense soil complete all as specified and as directed. 3 Cement concrete 1:4:8 type D2 in foundations, filling and mass concrete complete all as specified and as directed. 4 M & L for Reinforced cement concrete type B-1, 1:2:4, using 20mm graded stone aggregate as in footings, plinth beams and mass concrete complete all as specified and as directed. 5 M & L for Reinforced cement concrete type B-1, 1:2:4, using 20mm graded stone aggregate as in Columns., pillars complete all as specified and as directed. 6 M & L Reinforced cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in lintels upto 1.5m clear and other similar bands, including form work complete all as specified and as directed. 7 M & L for Reinforced cement concrete type B-1, 1:2:4, using 20mm graded stone aggregate as in floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc., complete all as specified and as directed. 8 M & L Reinforced cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in slabs supported on walls, beams etc., complete all as specified and as directed. 9 Use and waste of form work to sides of concrete foundations, footings, plinth beams for rough finished concrete surfaces complete all as specified and as directed. 10 Use and waste of form work to sides of pillars, posts, columns for rough finished concrete surfaces complete all as specified and as directed. 11 Form work to sides and soffit of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports complete all as specified and as directed. 12 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work incl sides of slab, n exc 200mm thick (Horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed. 13 S & F TMT steel bars 10mm dia and over, cut to length bent to shape required as in reinforce ment to lintels complete all as specified and as directed. 14 All as per item No.13 here-in-before but 6mm to 8mm dia complete all as specified and as directed. 15 All as per item No 13 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups complete all as specified and as directed. 16 M & L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 complete all as specified and as directed. 17 M & L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:4 complete all as specified and as directed. 18 Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and as directed. 19 Removal of surplus spoil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. 20 Earth filling under floors including Spreading and levelling in layers n.exc 25cm thick including well ramming including watering as required complete all as specified and as directed. 21 M & L Hardcore (stone) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 22 M & L 75mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base floor complete all as specified and as directed. 23 M & L for 25mm thick cement concrete, 1:2:4, type B-1 using 20mm graded stone aggregate as in under layer to tile finishes complete all as specified and as directed. 24 M & L vitrified joint free tiles 10mm thick light shade area of each tile exc 0.42sqm but not exc 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including cement screed bed 15 mm thick in CM 1:4 complete all as specified and as directed. 25 M & L for glazed coloured joint free tiles in vertical surfaces, 1200mm x 600mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement including cement mortar 10mm thick in CM 1:3 complete all as specified and as directed. 26 M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment or mat over and including cement screed 15 mm thick in CM 1:4 complete all as specified and as directed.Note:- colour other than black or brown and as speciffied and as approved / directed by EIC 27 M & L for Rendering 10mm thick in CM 1:6 on wall or concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed. 28 M & L for Rendering 5mm thick in CM 1:3 on ceiling of concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed. 29 M & L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surface even and smooth complete all as specified and as directed. 30 M & L for Rendering 10mm thick in CM 1:4 as in water proofing treatment and finished even and smooth (without using extra cement) as in roof treatment complete all as specified and as directed. 31 M & L for water proofing treatment with APP based polymeric membrane modified prefabricated five layer water proofing membrane, not less than 3mm thick and weighing not less than 3.60 Kg/Sqm reinforced with non woven polyester matt black finished over compatiable primer at 0.3 litre/Sqm, touching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions . The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in tranverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage.Manufactures:- IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STP.Note:- The work shall be carried out be authorised applicators of manufactures.Four course of roof treatment consist of as under:-(i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 ltr /sqm(ii) Laying of APP based membrane as specified thickness and weight(iii) Applying one coat of Bitumen grade 85/25 @ 1.2 kg/Sqm(iv) Applying two coats aluminium paints @ 100ml/sqm 32 Preparing new plastered wall surfaces and applying two coat of oil bound distemper over a coat of primer over 3mm thick wall care putty complete all as specified and as directed. 33 Preparation of new ceiling surfaces including necessary scaffolding and applying three coats of white wash complete all as specified and as directed. 34 Preparation new walls surfaces and applying two coats of exterior weather proof paint over a coat of weather proof primer to all external wall surfaces complete all as specified and as directed. 35 S & F Powder coated anodised aluminium frame / shutters for ventilator, doors, Partitions with one or more rebates including jointing cleat for fixing etc., complete all as specified and as directed. 36 S & F 4mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in eachpane and fixed to aluminum frames using rubber packing complete all as specified and as directed. 37 Supply only integral water proofing liquid 38 M & L for 50mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in plinth protection & paving finished even and smooth without using extra cement complete all as specified and as directed. 39 Rounding to edges of Granite/stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 40 S & F PVC connection 15 mm size with PTMT nuts of length 450mm. 41 S & F PVC (SWR) floor trap with grating including jointing to solvent cement wast pipe 75mm dia. 42 S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor, 110 mm bore complete all as specified and as directed. 43 S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed on walls, 110 mm bore complete all as specified and as directed. 44 S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor, 75mm bore complete all as specified and as directed. 45 S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed on walls, 75mm bore complete all as specified and as directed. 46 S & F PVC (SWR) junction single, (Single T) equal or unequal for 110 mm bore pipe with access door complete all as specified and as directed. 47 S & F PVC (SWR) junction single, (Single T) equal or unequal for 75mm bore pipe with access door complete all as specified and as directed. 48 S & F PVC (SWR) bend 110 mm bore 49 S & F PVC (SWR) bend 75 mm bore 50 S & F PVC (SWR) vent cowl 110 mm 51 S & F PVC (SWR) Gully trap 125 / 110mm setting and jointing with solvent cement. 52 Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/ ceiling/ floors complete all as specified and as directed. 53 All as per item No 52 here-in-before but of 25 mm CPVC pipes 54 All as per item No 53 here-in-before but of 50 mm CPVC pipes 55 S & F rotationals moulded, tripple layered, polythylene water storage tanks of capacty 1000 litres (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and as directed. 56 S & F of 25mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. 57 S & F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. 58 S & F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof Bore of pipe 110mm complete all as specified and as directed. 59 M & L for 150mm dia Reinforced concrete pipes NP3, laid and jointed complete with collars complete all as specified and as directed. 60 M & L for cement concrete 1:3:6 type C2 bed to 150mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 61 Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm allas specified incl Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and as directed. 62 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls complete all as specified and as directed. 63 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, internal dia of pipe 150mm complete all as specified and as directed. 64 S & F CPVC 50mm dia brass elbow 65 S & F CPVC 25mm dia brass elbow 66 S & F CPVC 20mm dia brass elbow 67 S & F CPVC 50mm dia brass Tee 68 S & F CPVC 25mm dia brass Tee 69 S & F CPVC 20mm dia brass Tee 70 S & F CPVC 50mm dia Male brass threded adaptor (FTA/FBTA) 71 S & F CPVC 25mm dia Male brass threded adaptor (FTA/FBTA) 72 S & F CPVC 50mm dia brass Union 73 S & F CPVC 25mm dia brass Union 74 S & F CPVC 20mm dia brass Union 75 M & L Fire brick work in linings to fire places, flues, etc. (other than in chimney shafts), set, jointed and pointed in fireclay as in decorated elevation work in CM 1:4 complete all as specified and as directed. 76 S & F 12mm thick structural glazing with toughned glass fixed with aluminium frame as in front elevation all as per manufacture instruction complete all as specified and as directed. 77 S & F sliding glass door with 12mm thick toughnend glass including embosing loco of gents and ladies necessary accessories for functional aspects complete all as specified and as directed. 78 S & F 12mm thick non transparent toughned glass partition height 2100mm as in cubical shape with hinged door of toughen glass size 900 mm x 1800mm incl fittings such as handle, hinges etc for functional aspects complete all as specified and as directed.(Manufacturer:- vision glass and interiors or equivalent) 79 S & F vitreous china wall mounted wash down water closet (pedestal pattern) , white, of style and pattern complete with and including integral flushing cistern, plastic seat cover, white fixed complete all as specified and as directed. 80 S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. 81 S & F in repairs 3 in 1 wall mixer with provision of both hand shower and over head shower complete all as specified and as directed.Make:- Jaquar (Continental) Cat No : CON-281 KN 82 S & F Vitreous China counter sunk oval shaped wash basin white, embedded on granite platforms including cutting for and pinning in ends of brackets or erecting stand brackets, incl Supply & Fixing of 32 mm bottle trap of CP (half or full threaded) and 32mm dia waste pipe complete all as specified and as directed.Make:- Jaquar or equivalent 83 S & F Vitreous China Urinal, full stall type white coloured complete including urinal spreader and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. including of fixing supply pipe to flushing cistern, waste pipe to trap complete all as specified and as directed. 84 S & F Angle valves 15 mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.Make:- cat No: 35053PM KUBIX of Jaquar or equivalent 85 S & F Pillar taps 15mm, cast copper alloy with capstan heads, stainless steel screwed down high pressure with long screwed shanks and flynuts screwed for iron pipe and fixed complete all as specified and as directed.Make:- cat No: COP-CHR-021PM KUBIX of Jaquar or equivalent 86 S & F 5mm thick mirror size 1500mm x 450mm of bevelled edge fixed with screw over WHB complete all as specified and as directed. 87 S & F Toilet paper holder of stainless steel with flat recessed type complete all as spcd. fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.Make:- cat No: CAN-CHR-1153S of Jaquar or equivalent 88 S & F stainless steel Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.Make:- cat No: Acn-Chr-1111m of Jaquar or equivalent 89 Material and Labour for Point wiring complete with 1.5 sqmm FRLSH single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-matallic rigid PVC conduit PVC conduit fittings and conduit asccessorries concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telphone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continmuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10Cm girth complete all as specified and as directed for the following:- 90 (a) One light point controlled by one switch. 91 (b) One Exhaust Fan controlled by One Switch 92 (c) One 3 pin 5 amps switch socket on independent board. 93 (d) One 3 pin 5 amps switch socket on same board along with other switches. 94 All as per item No.89 here in before but with 4 sqmm copper conductor cable with 2.5 sqmm FRLSH PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch 15/16 Amps on independent board complete all as specified and as directed. 95 S & F Wall mounted LED 20W Batten Basic all purpose surface and wall mounted LED batten with Aluminium housing & Integrated electronic driver complete all as specified and as directed. 96 S & F wall mounted LED batten Extruded aluminium housing provided efficient heat disipation with polycarbonate diffuser with integrated electronic driver high efficacy.short circuit & voltage cut off protection, wide opearting voltage range of 140V to 270V wide, lumen output of 1050,10W including lamp with complete all as specified and as directed. 97 Supply, Installation, testing and commissioning of Surface mounted LED luminaries with Mid flux LED using efficient optics , System lumen efficacy > 80Lumen/Watt , System Luminous flux of >=3200 lumens, System Wattage <=42W with 50,000 hours burning life. Color rendering index > 70 and Color temperature 5000K/6500K. CRCA housing with high efficiency opal diffuser. Luminaries sealed from bottom. Inbuilt gear . Zero maintenance, Zero mercury. Driver Surge protection > 1.5kV. Electronic In-Built PF > 0.9 , THD < 10% , IEC Compliant for Safety , Performance & EMI. The size shall be of 2x2. 98 S & F Endura PEARL 30W MP Bldg Sec lights New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP 66 roadway luminarie with high power LEDs as light source and electronic driver of Lamp type 30W LED 6000K complete all as specified and as directed. 99 S & F MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. 100 S & F MCB SP 230 volts,40 amps C Curve 10 kA Capacity complete all as specified and as directed. 101 S & F MCB SPN 230 volts, 40 amps C Curve 10 kA Capacity complete all as specified and as directed. 102 S & F Ceiling rose surface bakelite 65mm x 50 mm two to three terminals complete all as specified and as directed. 103 S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and as directed. 104 S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed. 105 S & F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and as directed. 106 S & F Modular socket 6 A/ 16 A - 2/3 pin combined 2 module complete all as specified and as directed. 107 S & F Exhaust Fan 300mm Metal Body Heavy Duty complete all as specified and as directed. 108 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc complete all as specified and as directed. 109 Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. 110 Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and as directed. 111 Supplying and laying burnt brick B class standard size for protection of cable complete all as specified and as directed. 112 Fine Sieved excavated dry soil (ridgled & Earth) laid to the required width of trench at bottom and top of cable as cushioning complete all as specified and as directed. 113 Boring holes under road pavement by bocky manually in any type of soil upto 150 mm bore complete all as specified and as directed. 114 Supply & Laying cable XLPE insulated screened PVC bedded, gaivanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes all as specified and as directed. 115 2 core 10 SqmmNote :- i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly whereever required while connecting cables to the panel board.ii) Earth work such excavation, refilling, etc. shall be measured separately under relevant items. 116 Supply and Laying of GI Tubing of galvanized medium grade of 40mm including all fittings such as bend, elbow, tee and union in trenches/ on floors/ wall/ ceiling etc., complete all as specified and as directed. 117 Material and Labour for Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth wire 4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 86800.0 /-
Tender Value
INR 43.40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.