| 1 | Running Maintenance and Operation of filtration plant with ozonator and heat pumps and other accessories of swimming pool as per detail of installation at Annexure A by deploying following staff 3 Nos. Operator (6AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM) and 3 Nos. Khallasi (One No. in each shifts, total three shifts) |
| 2 | Supplying and Putting of chemicals for swimming pool and cleaning of swimming pool complete as required as per additional condition enclosed. a.)Liquid Chlorine 720Kg. Per Month OR TCCA 90-90Kg Per Monthb.)Liquid HCl 700 ltr.Per Monthc.)Copper Sulphate 10Kg.Per Monthd.)Alum 50Kg. Per Month |
| 3 | Running Maintenance and Operation of filtration plant with ozonator and heat pumps and other accessories of swimmingpool as per detail of installation at Annexure A by deploying following staff. 1 Nos. operator (9 AM to 5 PM ), 2 Nos.Khallasi(one in each shift total of two shifts (i.e. 6AM to 2 PM & 10 PM to 6 AM) |
| 4 | Supplying and Putting of chemicals for swimming pool and cleaning of swimming pool complete as required as per additional condition enclosed.a.)Liquid Chlorine 300Kg. Per Month b.)Liquid HCl 300 ltr.Per Monthc.)Copper Sulphate 2Kg.Per Monthd.)Alum 25Kg. Per Month |
| 5 | Servicing of Heat pump ( Scroll outdoor type) of heating capacity 135 KW, Pentair make including cleaning, tightening of all pipe connections, electrical connections etc. complete as required. |
| 6 | Supply and Replacement of existing unrepairable compressor with new compressor in Heat Pump of Swimming pool etc. complete as required. |
| 7 | Supply and replacement of Monoblock centrifugal pump of 10 HP capacity delivering 115 m³/hr at 12 meter head with a rotational speed of 2900 RPM, including dismantling of existing pump unit from its location using appropriate methods such as cutter machine/gas cutter, and installing the new pump onto the existing or modified pipeline header. The pump shall be fitted with a CI (Cast Iron) body suction strainer of 100mm diameter having SS or brass mesh for debris protection. The scope includes necessary repairs or replacement of the base frame, pipeline header, header pipes, and allied fittings as required at site, along with the provision and fixing of anti-vibration pads for stable and noise-free operation. All fittings, supports, alignment, and testing shall be done as per site conditions and engineering best practices.etc. complete as required (i/c rebate for dismantled material) |
| 8 | Supply & replacement of heavy-duty Butterfly Valves of required sizes, complete with gaskets, and nut bolts, including removal and dismantling of the existing damaged PVC butterfly valves from their current location using appropriate cutting tools. The valve shall be constructed from high-grade unplasticized polyvinyl chloride (uPVC) with exceptional chemical and UV resistance. It shall include a stainless steel (SS304/SS316) drive shaft, precision-engineered disc for optimized flow control, and integral Viton® or EPDM seals for maximum leak-proof performance and long service life. The work shall involve precise cutting of the existing pipeline, modification as required, and proper jointing with new fittings such as sockets, elbows, or tees, along with the supply and installation of PVC pipes ranging from 110mm to 200mm diameter, pressure rating minimum 10 kg/cm², wherever required to ensure proper connectivity and functionality. The scope also includes leak testing, alignment, support arrangements, and all contingencies required to complete the job in a professional and workmanlike manner. etc. complete as required (i/c rebate for dismantled material) |
| 9 | 200mm dia |
| 10 | 160mm dia |
| 11 | Supply & replacement of high-performance Non-Return Valve (NRV) made of industrial-grade unplasticized polyvinyl chloride (uPVC), conforming to specifications similar to those offered by Georg Fischer Type 561/562 Series, suitable for a working pressure of 10 kg/cm² (PN 10). The valve shall be of wafer-type design with integrated flange adaptor connections, including all necessary fasteners such as nut bolts and EPDM/Viton gaskets to ensure leak-proof operation. The scope includes removal and dismantling of the existing damaged PVC PRV using appropriate cutting tools, followed by precise cutting and modification of the existing pipeline for installation of the new NRV. Jointing shall be carried out using suitable PVC fittings such as sockets, elbows, and tees, and shall include supply and fixing of additional PVC pipes of required diameter (ranging from 110mm to 200mm), wherever necessary to complete the line adjustment and proper valve seating.etc. complete as required.(i/c rebate for dismantled material) |
| 12 | 160mm dia |
| 13 | Repair, overhauling, and reconditioning of the existing Electrical Control Panel for swimming Pool Filtration Plant specifically designed to handle 10 HP pump motors (each operating at approx. 7.5 kW load). The scope of work includes comprehensive inspection, identification, and replacement of all defective electrical components such as push buttons, LED indicators, selector switches, contactors (3-pole, AC3 duty), and thermal overload (O/L) relays suited for 10 HP motor protection, with current range typically between 12–18 Amps,MCB,MCCB,Switch gear & any other electrical equipmentetc. Replacement parts shall conform to IEC standards and shall be of approved make such as L&T/Siemens/Schneider or equivalent. The job includes disconnecting and reconnecting all control and power cables within the panel using appropriately sized insulated copper thimbles/lugs and crimping tools to ensure safe and secure electrical connections. All cable terminations shall be properly labeled, tagged, and neatly arranged. Work shall also cover tightening of busbar connections, cleaning of dust and carbon deposits inside the panel enclosure, and minor fabrication or rewiring where necessary to restore operational safety and functionality .Additionally, the repaired panel shall be tested for insulation resistance, phase sequence, load current verification, and full functional testing of motor starters and interlocks with the pool pump motors. The contractor shall ensure synchronization with existing automation or manual control logic, if any, and proper motor connection (Star/Delta ) using 3.5-core armored cable with suitable gland termination. All work shall be completed to the satisfaction of the Engineer-in-Charge etc. complete as required (i/c rebate for dismantled material if any) |
| 14 | Supply and replacement of Pressure gaurge of the dia 100mm and of range upto 7.0 kg/cm2 pressure etc. complete as required. |
| 15 | Provinding and replacing the filter media of thefiltraiton plantsofswimming pool i/c replacing the defective lid and cover, pressure gauge, air release valve etc of the filter units |
| 16 | Supply and topup ofFilter Media. Grade1 - 25kg bag size 0.5 to 1 mm etc. complete as required |
| 17 | Supply and topup ofFilter Media. Grade2 - 25kg bag size 2 to 3 mm etc. complete as required |
| 18 | Supply and topup of Filter Media. Grade3 - 25kg bag Size 3 to 6 mm etc. complete as required |
| 19 | Supply and replacement of a complete Valve Battery Manifold assembly fabricated from high-quality PVC with integrated flanged connections for direct coupling with filtration units. The manifold shall comprise a set of five (5) heavy-duty Butterfly Valves of size 110mm / 140mm / 160mm (as per system design),14 Flanges,5 TEE,5 Elbow to facilitate smooth operation of filtration, backwashing, rinsing, and shutdown processes of the swimming pool filtration system. The scope includes fabrication and fixing of the manifold with zinc-plated steel support brackets, anti-vortex clamps, and structurally stable valve battery supports to ensure leak-proof performance and vibration-free operation under system pressure. All valves shall be hydro-tested and aligned accurately for manual or automated operation.etc. complete as required |