Tender For Repair/Replacement Of Internal Wiring And Misc Items For Otm Accn Under Ge Gwalior, gwalior-Madhya Pradesh

Military Engineer Services has published Tender For Repair/Replacement Of Internal Wiring And Misc Items For Otm Accn Under Ge Gwalior. Submission Date for this Tender is 01-09-2025. Electrification Work Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50629670
Tender For Repair/Replacement Of Internal Wiring And Misc Items For Otm Accn Under Ge Gwalior
Tender
Indian
Madhya Pradesh
Gwalior
01-09-2025

Tender Details

Tender For Repair/Replacement Of Internal Wiring And Misc Items For Otm Accn Under Ge Gwalior; 1 Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. 2 Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed. 3 Taking down unserviceable Sheet metal box,Single pole and neutral encloser with top & MCB DB SPN with MCBs of any make/capacity, complete, all as specified and directed by Engr-In-Charge. 4 Taking down unserviceable Sheet metal box & MCB DB TPN with MCBs of any make/capacity, complete, all as specified and directed by Engr-In-Charge. 5 M&L, concealed point wiring with PVC insulated and unsheathedelectric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No)not less than 20 mm diawith all fitting and fixing accessories and1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes/modular flush boxfactory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint insidefor mounting switches. sockets etccomplete for the following:- 6 One bulb point controlled by one switch. 7 One tubelight point controlled by one switch. 8 One Ceiling fan point controlled by one switch. 9 One Exhaust fan point controlled by one switch. 10 One Bell/Buzzer point controlled by one way 5 Amp push button switch. 11 One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. 12 One 3 pin/5 pin switch socket outlet, 5 Amps on independent board. 13 For one light pointcontrolled by 2- two way switch. 14 Description all as per item No 5 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire. 15 S&F Modular switch 1 way 6A,1 module complete all as specified and directed. 16 S&F Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed. 17 S&F Modular switch 1 way 16A,1 module 15 Amp complete all as specified and directed. 18 S&F Socket 6A/16A - 6 pin combined 2 module complete all as specified and directed. 19 S&F Modular switch 2 way 6A, 1 module complete all as specified and directed. 20 S&F modular bell push flush type, 5 Amps complete all as specified and directed. 21 S&F Ding Dong Bell, AC, 230 Volts, complete all as specified and directed. 22 S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. 23 S&F Fan step regulator, 80 to 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed. 24 S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete. 25 Supply and Fix Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 4500/6500K ,luminous efficiency> 100 lm/wattfitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting and testing on completion all as specified and directed. 26 M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. 27 M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. 28 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 sqmm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded BTstone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in D shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed. 29 S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCBs are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making goodthe distributed wall surfaces to match with existing specification including taking down all as directedby Engr-in-Charge at site. 30 S&F MCB DB, sheet metal enclosures double door TPN 4 way with bus bar 415 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed 31 S&F TPN 40 To 100 Amp, 415V 10KA C curve miniature circuit breaker (MCB) of four poles and current carrying capacity in the DB complete with connection testing and commissioningwith suitable size copper lugs complete all as specified and directed.. 32 S&F MCB DB, sheet metal enclosures double door SPN 12 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed 33 S&F MCB DB, sheet metal enclosures double door SPN 8 way withbus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed 34 S&F, MCB SPN 40 to 63 Amps, 240 volts C series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed.. 35 S&F, MCB SP 6 to 40 Amps,240 volts,C series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. 36 S & F sheet metal box Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp. 37 S&F in renewal switch piano, flush button single pole one way 5 Ampincluding taking down complete all as specified and directed. 38 S&F in renewal socket out let, multipurpose, 2 in 1 5 pin, 5 Ampincluding taking down complete all as specified and directed. 39 S&F in renewal switch piano, flush button single pole one way 15 Amp completeincluding taking down all as specified and directed. 40 S&F in renewal socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 ampsincluding taking down complete all as specified and directed. 41 S&F in renewal switch piano, flush button single pole two way 5 Amp completeincluding taking down all as specified and directed. 42 S&F in renewal bell push flush type, 5 Amps completeincluding taking down all as specified and directed. 43 S&F in renewal Ding Dong bell, AC, 230 Volts, connecting with bell point complete all as specified and directed. 44 S&F in renewal electronic step rotary type fan regulator capacity 80 to 120 Watt, 240 volts, AC 50Hz complete all as specified and directed. 45 S&F in renewal Switch Socket Combination 2 in 1 5 pin, 5 Ampincluding taking down complete all as specified and directed. 46 S&F in renewal Switch Socket Combination 2 in 1 6 Pin 5/15 amp including taking down complete all as specified and directed. 47 S&F in renewal of LED security light fittings 35 Watt 230 V AC outdoor type better optics for uniform distribution IP 65/66 protection LED with automatic on off sensor based, Heat resistance glass, pressure die cast aluminium housing including reqdlength of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed. 48 S&F in renewal of Decorative ultra slim LED Tubelight fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 4000/6500K ,luminous efficiency> 100 lm/wattfitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including taking down of oldu/s light and testing on completion all as specified and directed. 49 S&F in renewal of Mirror fitting of LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 10 watt, 4500/6500K ,luminous efficiency> 100 lm/wattfitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting and testing on completion all as specified and directed. 50 S&F in renewal of heating element 2.0 KW, single phase, 230 volt with triangular/round base suitable for 25 to 50 ltrs geyser fitting and testing on completion all as specified and directed. 51 S&F in renewal of thermostat switchrange upto 80”C suitable for 25 to 50 ltrs geyser fitting and testing on completion all as specified and directed. 52 S&F in renewal ofplug top 3 pin 15 Amp completion all as specified and directed. 53 S&F in renewal ofplug top 3 pin 5 Amp completion all as specified and directed. 54 Taking down old damaged modular/Non modular metal flush box with damage hylum sheet of any size and model andprovising of new suitable size of modular/Non modular metal flush box with suitable size hylum sheet including refixing the old/new switch,socket,regulator and ss combination of different size complete all as specified and directed by engineer-in-charge 55 S&F for modular plateincluding fixing , modular switchs , modular socket ,modulare regulator complete all as specified and directed by engr-in-charge. 56 White cover plate with frame but 2/3/4 module 57 White cover plate with frame but 6/8/12 module

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail