}

Tender For Expression Of Interest For Providing, Making And Supplying Furniture & Furnishing Items At All Centres Of Navsari Agricultural University (Unit Rate Offer), Navsari-Gujarat

University Of Agriculture has published Tender For Expression Of Interest For Providing, Making And Supplying Furniture & Furnishing Items At All Centres Of Navsari Agricultural University (Unit Rate Offer). Submission Date for this Tender is 25-08-2025. Furnishing Work Tenders in Navsari Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

50625611
Tender For Expression Of Interest For Providing, Making And Supplying Furniture & Furnishing Items At All Centres Of Navsari Agricultural University (Unit Rate Offer)
Tender
Indian
Gujarat
Navsari
25-08-2025

Tender Details

Expression Of Interest For Providing, Making And Supplying Furniture & Furnishing Items At All Centres Of Navsari Agricultural University (Unit Rate Offer)- Providing, Supplying & Installation Of Snap-Fit Modular Wall Paneling Using 8Mm Pre-Laminated Cement Fiber Board The Framework Shall Consist Of 0.55Mm Thick Cold-Rolled G.I. Perimeter Channels (30X27x20mm) Fixed At 600Mm Centers With Nylon Sleeves And Wood Screws. “W” Shaped Ceiling Sections (26X50x26x80mm, Gyptech Or Equivalent) Shall Be Inserted Horizontally And Vertically To Create A 600X600mm Grid (Or As Per Design) And Fixed Using Appropriate Screws.Work Includes Marking Levels On Walls/Partitions As Per Design, Leaving Allowance For Panel Thickness. Installation Shall Use 8Mm Thick Wood-Textured Pre-Laminated Cement Fiber Boards (Make Approved By Nau Authority) Fixed In A Modular Snap-Fit System.Packing Of Solid Pvc/Marine Ply To Be Provided As Required. Aluminum Grid Sections (24X9mm) Extruded From 6063 Grade Alloy Shall Be Fixed To The Ceiling Section, Or Directly On The Wall/Partition Where Space Constraints Exist. Panels Will Be Secured Using 14X13mm Snap-Fit Powder-Coated Or Anodized Aluminum Clips. All Work To Be Executed In True Line And Level, With Approved Finish And As Per Directions Of Engineer-In-Charge., Providing, Supplying & Installation Of 12Mm X 120Mm Prelaminated Solid Core Wall Paneling Work Includes Providing And Installing 12Mm Thick X 120Mm Wide Prelaminated Solid Core Wall Panels (E-3 Clad) With A Seamless Joining System. Wall/Surface To Be Prepared And Marked For Alignment And Design. A Grid Of 50Mm X 15/20Mm Solid Pvc Strips (Density 550–600 Kg/M³) Shall Be Fixed To The Wall At 600Mm X 600Mm Spacing Using Screws. Panels Shall Be Mounted Using Double-Sided Adhesive Tape And Silicone Adhesive (Dow Corning Or Equivalent). All Work Shall Be Completed In True Line, Level, And Finish As Per Design And Instructions Of The Engineer-In-Charge., Providing, Supplying & Installation Of “Vox” / “Pare” Brand Thermal Printed Wall & Ceiling Paneling Work Includes Supply And Installation Of 3Mm Thick X 340Mm Wide Vox/Pare Brand Thermal Printed Panels Approved By Nau Authority) With A Tongue-And-Groove Joining System For Ceiling And Wall Paneling. Levels Shall Be Marked As Per Design, Allowing For Panel Thickness. 0.55Mm Thick G.I. Perimeter Channels (30X27x20mm, Make Approved By Nau Authority) Shall Be Fixed To Walls/Partitions At 600Mm Centers Using Nylon Sleeves And Wood Screws. A 1200X1200mm Hanger Grid Shall Be Marked On The Ceiling/Slab. 0.55Mm Thick G.I. Hangers (18X18mm), Cut 6 Longer Than The Drop, Shall Be Fixed To The Slab And Intermediate Channels Using Self-Drilling Screws. 0.9Mm Thick C-Sections (15X45x15mm) Will Be Suspended At 1200–1500Mm Centers. Overlaps Of 6 Shall Be Provided For Extended Lengths. 0.55Mm Thick W-Sections (26X50x26x80mm) Shall Be Fixed Perpendicularly At 450–600Mm Centers To Form The Ceiling Grid. Panels Will Be Screw-Fixed To The Frame With Longitudinal Alignment Across Ceiling Sections. Panel Joints Will Be Finished Using Matching Brand “J” Sections (19X40mm) Or Connector Profiles (76X12mm). All Joints And Caps Will Be Bonded With Cyanoacrylate Adhesive (Make Approved By Nau Authority). Work Must Be Executed In True Line, Level, And Finish As Per Approved Design And Under The Supervision Of The Engineer-In-Charge., Providing, Supplying & Installation Of Snap-Fit Modular Wall Paneling Using 12Mm Prelaminated Wood Chip Particle Board Work Includes Installation Of 12Mm Thick Prelaminated Wood Chip Base Particle Boards (Make Approved By Nau Authority) In A Modular Snap-Fit Paneling System. Mark Levels On Walls/Partitions As Per Drawings. Fix 0.55Mm Thick G.I. Perimeter Channels (30X27x20mm, Make Approved By Nau Authority) At 600Mm Centers Using Nylon Sleeves And Wood Screws. Install 0.55Mm Thick “W” Shaped Ceiling Sections (26X50x26x80mm) Vertically And Horizontally To Form A 600X600mm Grid, Or As Per Design, Secured To The Perimeter Channel. Provide Necessary Packing (Solid Pvc/Marine Ply) Behind The Ceiling Sections And Fix To Structure. Aluminum Sections (24X9mm, 6063 Grade Alloy) Shall Be Mounted On Ceiling Sections To Support Panel Grid. Boards Will Be Snap-Fixed Into The Grid Using 14X13mm Powder-Coated Or Anodized Aluminum Clips. Where Space Constraints Exist, Aluminum Base Channels (24X9mm) May Be Fixed Directly To The Wall/Partition, And Boards Installed Accordingly Using The Same Snap-Fit Method. Work Must Be Completed In True Line, Level, And Finish As Per Design And Under Direction Of The Engineer-In-Charge., Providing, Supplying & Installation Of Cavity Modular Wall Paneling Using 12Mm Prelaminated Wood Chip Particle Board Work Includes Installation Of 12Mm Thick Prelaminated Wood Chip Base Particle Boards (Make Approved By Nau Authority) In A Cavity Modular Wall Paneling System. Mark Wall/Partition As Per Drawings, Allowing For Panel Thickness. Fix Extruded Aluminum Vertical Sections (44X25mm, Make Approved By Nau Authority) At 600Mm Centers Using Nylon Sleeves And Wood Screws. Insert Horizontal Aluminum Sections (12X53mm) To Form A 600X600mm Grid Or As Per Design. Provide Required Packing (Solid Pvc/Marine Ply) Behind Main Structure. Fix Aluminum Hook Sections (22X5mm, Make Approved By Nau Authority) To Receive Panels. Secure Panels To Frame Using Screws. Ensure All Work Is Completed In True Line, Level, And Finish As Per Design And Directions Of The Engineer-In-Charge., Providing, Supplying & Installation Of 9/10Mm Thick X 250–300Mm Wide Membrane-Coated Spc Section Wall & Ceiling Paneling Work Includes Installation Of 9Mm/10Mm Thick Membrane-Coated Stone Plastic Composite (Spc) Wall And Ceiling Panels (Iso 9001-Certified Make Approved By Nau Authority), With Tongue-And-Groove Joining System And Multichamber Hollow Design (Min. Wall Thickness 0.2Mm ± 0.015, Width 250–300Mm). Mark Levels As Per Drawings. Fix 0.55Mm Thick G.I. Perimeter Channels (30X27x20mm, Make Approved By Nau Authority) To Wall/Partition At 600Mm Centers. Mark A 1200X1200mm Ceiling Grid For Hanger Points. Install 0.55Mm G.I. Angles (18X18mm) As Hangers, And Suspend 0.9Mm Thick C-Channels (15X45x15mm) At 1200–1500Mm Centers, Overlapping 6 Where Extended. Fix 0.55Mm Thick W-Shaped Ceiling Sections (26X50x26x80mm) Perpendicularly At 450–600Mm Centers. Panels Shall Be Screw-Fixed To The Frame With Edges Across Ceiling Sections. Cover Open Ends With Matching U-Sections (9X28mm) Or L-Sections (25X25mm). At Joints, Provide Cornice Sections (35X35mm Double-Side Or 25X30mm Single). Use H-Sections (56X11mm) For Extending Panel Lengths. All Joints And Trims To Be Bonded With Cyanoacrylate Adhesive (Make Approved By Nau Authority). All Work To Be Executed In True Line, Level, And Finish As Per Approved Design And Instructions Of The Engineer-In-Charge., Providing & Fixing Cement Fiber Board / Calcium Silicate (Plain) Wall Paneling Work Includes Wall Paneling Using 10Mm Thick Plain Cement Fiber Board / Calcium Silicate Board / Cement Bonded Particle Board, Fixed To A G.I. Framework. Mark Levels As Per Approved Drawings. Fix 0.5Mm Thick G.I. “U” Perimeter Channels (Web 26Mm, Flange 20/27Mm; Make Approved By Nau Authority) At 610Mm Centers Using Nylon Sleeves And Screws (38Mm Or Longer). Insert Ceiling Sections (Web 51Mm, Flange 22Mm) At 600Mm Centers Into Perimeter Channels And Check Alignment. Boards To Be Screw-Fixed Using 7G X 25Mm Csk Self-Drilling Screws At 200Mm Intervals. Provide Extra Ceiling Sections As Required For Support. Maintain 2–3Mm Board Gaps; Screws To Be Fixed At Least 1.5X Board Thickness From Edges And 40Mm From Corners.Board Edges Should Be Recessed If Square, And Joints Staggered In Brick Pattern (Or Straight As Per Architect’S Instruction). Finish Joints With Jointing Compound And Fiber Tape For Seamless Finish. If Required, Apply Water-Based Primer Before Putty/Paint. Painting (Distemper, 2 Coats) Will Be Paid Separately As Per Approved Rates. All Work To Be Completed In True Line, Level, And Finish As Directed By The Engineer-In-Charge., Providing & Fixing 12Mm Thick Mr 303 Grade Plywood Wall Paneling Work Includes Wall Paneling Using 12Mm Thick Mr 303 Plywood Make Approved By Nau Authority, Fixed To A G.I. Framework. Mark Levels As Per Approved Drawings. Fix 0.5Mm Thick G.I. “U” Perimeter Channels (Web 26Mm, Flange 20/27Mm; Make Approved By Nau Authority) At 610Mm Centers Using Nylon Sleeves And Screws (38Mm Or Longer). Insert Ceiling Sections (Web 51Mm, Flange 22Mm) At 600Mm Centers Into Perimeter Channels And Check Alignment. Plywood To Be Screw-Fixed Using 7G X 25Mm Csk Self-Drilling Screws At 200Mm Intervals. Provide Extra Ceiling Sections As Required For Support. Maintain 2–3Mm Plywood Gaps; Screws To Be Fixed At Least 1.5X Plywood Thickness From Edges And 40Mm From Corners. All Work To Be Completed In True Line, Level, And Finish As Directed By The Engineer-In-Charge., Providing & Fixing 18Mm Thick Mr 303 Grade Plywood Wall Paneling Work Includes Wall Paneling Using 18Mm Thick Mr 303 Plywood Make Approved By Nau Authority, Fixed To A G.I. Framework. Mark Levels As Per Approved Drawings. Fix 0.5Mm Thick G.I. “U” Perimeter Channels (Web 26Mm, Flange 20/27Mm; Make Approved By Nau Authority) At 610Mm Centers Using Nylon Sleeves And Screws (38Mm Or Longer). Insert Ceiling Sections (Web 51Mm, Flange 22Mm) At 600Mm Centers Into Perimeter Channels And Check Alignment. Plywood To Be Screw-Fixed Using 7G X 25Mm Csk Self-Drilling Screws At 200Mm Intervals. Provide Extra Ceiling Sections As Required For Support. Maintain 2–3Mm Plywood Gaps; Screws To Be Fixed At Least 1.5X Plywood Thickness From Edges And 40Mm From Corners.All Work To Be Completed In True Line, Level, And Finish As Directed By The Engineer-In-Charge., Providing & Fixing Designer Cement Fiber / Calcium Silicate Wall Paneling Work Includes Wall Paneling Using 10Mm Thick Designer Cement Fiber / Calcium Silicate / Cement Bonded Particle Board, Fixed Over A G.I. Framework. Mark Levels As Per Drawing. Fix 0.5Mm Thick G.I. “U” Perimeter Channels (Web 26Mm, Flange 20/27Mm; Make Approved By Nau Authority) At 610Mm Centers Using Nylon Sleeves And Screws. Insert Ceiling Sections (Web 51Mm, Flange 22Mm) At 600Mm Centers Into Perimeter Channels. Ensure Plumb Alignment And Fix Necessary Inserts Behind Channels.Boards Shall Be Screw-Fixed Using 7G X 25Mm Csk Self-Drilling Screws At 200Mm Intervals. Recess Edges (40X1.5Mm) If Boards Are Square-Edged. Provide Extra Ceiling Sections Where Needed For Proper Support. Maintain 2–3Mm Gaps Between Boards And Position Screws Minimum 1.5X Board Thickness From Edges And 40Mm From Corners. Joints To Be Staggered In A Brick Pattern (Or Aligned Straight As Per Architect) And Finished Using Jointing Compound And Fiber Tape For Seamless Appearance. If Required, Apply Water-Based Wood Primer Before Putty Or Paint. Painting (2 Coats Distemper) Shall Be Paid Separately As Per Approved Rates. All Work Shall Be Carried Out In True Line, Level, And Finish As Per Design And Instructions Of The Engineer-In-Charge., Providing & Fixing 12.5Mm M.R. Gypsum Board Concealed Ceiling Work Includes Installation Of 12.5Mm Thick Moisture-Resistant Gypsum Board (Size 1220X2440mm/3050Mm) Over A Concealed G.I. Ceiling Framework.Mark Ceiling Levels As Per Drawing. Fix 0.5Mm Thick G.I. “U” Perimeter Channels (Web 26Mm, Flange 20/27Mm; Make Approved By Nau Authority) At 610Mm Centers Using Nylon Sleeves And Screws. Create A 1220X1220mm Grid For Hanger Points. At Intersections, Drill 13Mm Holes And Fix 12X38mm Fasteners With Soffit Cleats (1.8Mm Thick).Suspend Intermediate Channels (Web 45Mm, Flanges 15Mm) Using 25X10mm G.I. Angles, Fixed With 6X12mm Nuts And Bolts. Overlap Channels By 150Mm Where Needed. Fix Ceiling Sections (Web 51Mm, Flange 22Mm) Perpendicular To Intermediate Channels At 305Mm Centers Using Connecting Clips/Screws. Overlap Where Needed By 150Mm.Form Openings For Lights, A/C Grills, Etc. Using Perimeter Channels. Fix Boards To Ceiling Sections With 7G X 25Mm Csk Self-Drilling Screws @ 200Mm Centers, Maintaining 2–3Mm Board Gaps. Screws To Be Fixed At Least 1.5× Board Thickness From Edges And 40Mm From Corners. Recess Square-Edged Boards (40X1.5Mm) If Required.Stagger Board Joints In Brick Pattern (Or Straight As Per Architect’S Instruction) And Finish With Jointing Compound And Fiber Tape For Seamless Finish. Apply One Coat Of Water-Based Primer, One Coat Of Birla Putty, And Two Coats Of Approved Shade Distemper (Painting Paid Separately As Per Approved Rates).All Work To Be Executed In True Line, Level, And Finish As Per Approved Design And Instructions Of The Engineer-In-Charge., Providing & Fixing Exposed Grid Ceiling With Designer Cement Fiber Board Tiles Supply And Install An Exposed Grid Ceiling System Consisting Of: 0.4Mm Thick Pre-Coated Steel L-Angle (24X24mm) Fixed To Walls/Partitions At 450Mm Centers Using Nylon Sleeves And Wood Screws. · Main T-Sections (24X38x3000mm) With ‘H’ Notches At 300Mm Centers, Suspended From Soffit At 1200Mm Centers Using Metal Rowel Plugs, Soffit Cleats, Level Clips, And 4Mm Dia G.I. Wire. · Cross T-Sections (24X38x1200mm) Fixed To Main T At 600Mm Centers To Form A 600X1200mm Grid. · Additional Cross T-Sections (24X38x600mm) Inserted At 600Mm Centers To Create A 600X600mm Grid. Lay 4Mm Thick Designer Cement Fiber Board Tiles (595X595mm, Make Approved By Nau Authority) Onto The Grid.Execute All Work In True Line And Level With Proper Finish As Directed By The Engineer-In-Charge., Providing & Fixing Exposed Grid Ceiling With Glass Reinforced Gypsum (Grg) Designer Tiles Supply And Install An Exposed Grid Ceiling System Comprising:0.4Mm Thick Pre-Coated Steel L-Angle (24X24mm) Fixed To Walls/Partitions At 450Mm Centers Using Nylon Sleeves And Wood Screws.Main T-Sections (24X38x3600mm) With ‘H’ Notches At 300Mm Centers, Suspended From Soffit At 1200Mm Centers Using Metal Rowel Plugs, Soffit Cleats, Level Clips, And 4Mm Dia G.I. Wire. Cross T-Sections (24X38x1200mm) Fixed To Main T At 600Mm Centers Forming A 600X1200mm Grid. Additional Cross T-Sections (24X38x600mm) Inserted At 600Mm Centers Forming A 600X600mm Grid. Lay 10–12Mm Thick Make Approved By Nau Authority Grg Designer Ceiling Tiles (595X595mm), With Non-Combustible Class O, Flame Spread Class 1, Nrc 0.60/0.75, Stc 0.35, And K-Value 0.45 W/Mk, Approved By Nau Authority. All Work To Be Done In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Fixing 5Mm Thick Prelaminated Solid Pvc Wall Paneling Supply And Fix 5Mm (±0.25Mm) Thick Prelaminated Solid Pvc Panels (1220X2400mm) By Iso 9001:2015 Certified Brand Make Approved By Nau Authority Panels Shall Be Mounted On An Inner Frame Of 50Mm Wide, 12Mm (±0.25Mm) Thick Pvc Strips (Density 600 Kg/M³). Strips Feature A 6Mm Wide, 1Mm Deep Groove For Countersunk Fixing Screws. Fix Pvc Strips Vertically To The Wall At 250Mm Centers Using 65Mm Anti-Corrosive Self-Drilling Screws Through The Groove, With Screws Spaced Max 300Mm Apart. Leave A 2Mm Groove At Panel Joints For Aesthetics. Panel And Grid Sizes May Vary As Per Site Conditions. Optionally, Fix A 5Mm Thick, 75Mm Wide Feathered Pvc Strip At Panel Joints Using Solvent Cement For Finishing. All Work To Be Executed As Per Engineer-In-Charge’S Directions., Providing, Supplying & Installing 5Mm Thick Solid Pvc Prelaminated Concealed Ceiling Mark Ceiling Level As Per Drawing. Fix 0.55Mm Thick G.I. Perimeter Channels (30X27x20mm) (Make Approved By Nau Authority) At 600Mm Centers With Nylon Sleeves And Screws. Fix 20Mm Wide, 5Mm (±0.25Mm) Thick Pvc Strips To Perimeter Channel. Mark 1200X1200mm Grid On Soffit For Hangers. Fix 0.55Mm Thick G.I. 18X18mm Angles From Roof/Slab To Intermediate Channels Using Self-Drilling Screws. Suspend 0.9Mm Thick C-Channels (15X45x15mm) At 1200–1500Mm Centers, Overlapped By 150Mm. Attach 0.55Mm Thick W-Shaped Ceiling Sections (26X50x26x80mm) Perpendicular At 450–600Mm Centers, Overlapped By 150Mm. Fix 50Mm Wide, 5Mm (±0.25Mm) Thick Pvc Strips To Ceiling Sections. Install 5Mm (±0.25Mm), 600Kg/M³ Density Solid Pvc Prelaminated Sheets (Make Approved By Nau Authority) As Ceiling Panels, Fixed Underside Of Frame With Solvent Cement Adhesive. Complete All Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 5Mm Thick Solid Pvc Prelaminated Concealed Ceiling Mark Ceiling Level As Per Drawing. Fix 0.55Mm Thick G.I. Perimeter Channels (30X27x20mm) (Make Approved By Nau Authority) At 600Mm Centers With Nylon Sleeves And Screws. Attach 20Mm Wide, 5Mm (±0.25Mm) Pvc Strips To Perimeter Channels. Mark 1200X1200mm Soffit Grid For Hangers. Suspend 0.55Mm Thick G.I. 18X18mm Angles From Roof/Slab To Intermediate Channels Using Self-Drilling Screws. Suspend 0.9Mm Thick C-Channels (15X45x15mm) At 1200–1500Mm Centers, Overlapped By 150Mm. Fix 0.55Mm Thick W-Shaped Ceiling Sections (26X50x26x80mm) Perpendicular At 450–600Mm Centers, Overlapped By 150Mm. Fix 50Mm Wide, 5Mm (±0.25Mm) Pvc Strips To Ceiling Sections. Install 5Mm (±0.25Mm), 600Kg/M³ Density Solid Pvc Prelaminated Sheets (Make Approved By Nau Authority) As Ceiling Panels Using Solvent Cement Adhesive. Execute All Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 3Mm Thick Aluminum Composite Premium Shade Exterior Grade Wall Paneling Two Options For Structure Preparation: Option 1: Mark Level As Per Drawing. Fix 0.5Mm Thick G.I. U-Shaped Perimeter Channels (Web 26Mm, Flange 20/27Mm) (Make Approved By Nau Authority) At 610Mm Centers With Nylon Sleeves And Screws. Insert Ceiling Se Option 2: Fix 15Mm Thick, 0.5 Density Solid Pvc Strips (50Mm Wide) To Wall With Nylon Sleeves And Self-Drilling Screws Forming 600X600mm Grid. Fix 3Mm Thick Aluminum Composite Panels (Make Approved By Nau Authority) To The Framing Using 3M Double-Sided Adhesive Tape And Dow Corning Silicone As Per Design. Complete Work In True Line, Level, And Finish As Directed By Engineer-In-Charge.Ctions (22Mm Flange, 51Mm Web) At 600Mm Centers. Ensure Plumb And Fix Inserts As Needed., Providing, Supplying & Installing 3Mm Thick Aluminum Composite Panel (Plain Color), Exterior Grade Wall Paneling Structure Preparation Options: Option 1: Mark Level As Per Drawing. Fix 0.5Mm Thick G.I. U-Shaped Perimeter Channels (Web 26Mm, Flange 20/27Mm) (Make Approved By Nau Authority) At 610Mm Centers With Nylon Sleeves And Screws. Insert Ceiling Sections (22Mm Flange, 51Mm Web) At 600Mm Centers. Ensure Plumb And Secure Inserts As Required. Option 2: Fix 15Mm Thick, 0.5 Density Solid Pvc Strips (50Mm Wide) To Wall With Nylon Sleeves And Self-Drilling Screws Forming 600X600mm Grid. Fix 3Mm Thick Plain Color Aluminum Composite Panels (Make Approved By Nau Authority) To The Framing Using 3M Double-Sided Adhesive Tape And Dow Corning Silicone As Per Design. Complete Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 6Mm Thick Hpl (High Pressure Laminate) Prelaminated Wall Paneling Mark Level As Per Drawing. Fix 0.5Mm Thick G.I. U-Shaped Perimeter Channels (Web 26Mm, Flange 20/27Mm) (Make Approved By Nau Authority) At 610Mm Centers With Nylon Sleeves And Screws. Insert Ceiling Sections (22Mm Flange, 51Mm Web) At 600Mm Centers, Ensuring Plumb And Secure Inserts As Required. Fix 6/8Mm Thick Interior Grade Hpl Prelaminated Boards To Framing Using 3M Double-Sided Adhesive Tape And Dow Corning Silicone As Per Design. Complete Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing & Fixing 12Mm Thick Perforated Glass Reinforced Gypsum (Grg) Designer Wall Paneling (Acoustic) Mark Level As Per Drawing. Fix 0.5Mm Thick G.I. U-Shaped Perimeter Channels (Web 26Mm, Flange 20/27Mm) (Make Approved By Nau Authority) With Nylon Sleeves And Screws At 610Mm Centers. Insert Ceiling Sections (22Mm Flange, 51Mm Web) At 600Mm Centers, Ensuring Plumb And Secure Inserts. Fix 12Mm Thick Perforated Grg Boards (Make Approved By Nau Authority) To Framing With Self-Drilling Countersunk Screws @ 200Mm Centers. Provide 2–3Mm Gaps Between Boards. Stagger Joints In Brick Pattern If Approved; Otherwise Straight Line For Uniform Grooves. Finish Joints With Compound And Fiber Tape For Seamless Appearance. Apply Water-Based Primer Before Putty/Paint. Two Coats Of Approved Distemper To Be Applied (Paid Extra). Complete Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 3Mm Thick Aluminum Composite Panel Plain Color Exterior Grade Curtain Wall Cladding (Elevation Purpose) Mark Levels As Per Drawing. Fix Welded G.I. Square/Rectangular Tube Grid (~600 X 900 Mm) For Structure (Structure Cost Paid Separately As Per Approved Rates). Fix 3Mm Thick Plain Color Aluminum Composite Panels (Make Approved By Nau Authority) To Framing Using 3M Self-Adhesive Double-Sided Tape And Dow Corning Silicone As Per Design. Ensure True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 3Mm Thick Premium Color Aluminum Composite Panel Exterior Grade Curtain Wall Cladding (Elevation Purpose) Mark Levels As Per Drawing. Fix Welded G.I. Square/Rectangular Tube Grid (~600 X 900 Mm) For Structure (Structure Cost Paid Separately As Per Approved Rates). Fix 3Mm Thick Premium Color Aluminum Composite Panels (Make Approved By Nau Authority) To Framing Using 3M Self-Adhesive Double-Sided Tape And Dow Corning Silicone As Per Design. Ensure True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installing 20Mm Thick Wood Plastic Composite Premium Color Exterior Grade Curtain Wall Cladding (Elevation Purpose) Mark Levels As Per Drawing. Fix Welded G.I. Square/Rectangular Tube Grid (~600 X 900 Mm) For Structure (Structure Cost Paid Separately As Per Approved Rates). Fix 20Mm Thick Wood Plastic Composite Panels With Tongue And Groove System Make Approved By Nau Authority) To Framing Using Anti-Corrosive Self-Drilling Screws As Per Design. Ensure True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing And Fixing Roller Blinds Supply And Install Roller Blinds (Iso 9001:2000 Certified Nau-Approved Brand). Aluminum Tracks With Acrylic Coating, Resistant To Cracking And Fraying, Including Necessary Mechanisms. Fabric To Be 0.50 Mm Thick Washable Polyester Woven, 200–300 Gsm, Available In Approved Colors And Designs (Shade Acute Plain, Bright Translucent, Lush Blackout, Soft Translucent, Screen Prints, Bamboo Blinds, Etc.). Use Quality Operating System And Cords. Complete Work With Good Finish As Directed By Authority., Providing And Fixing 2.5 Mm Thick Pvc Carpet Supply And Install 2.5 Mm Thick Vinyl Chloride Flooring Carpet (Make Approved By Nau Authority) In Approved Design And Color. Work Includes Labor, Materials, Adhesive, Wastage, And All Accessories As Directed By The Engineer-In-Charge., Providing And Fixing 2.0 Mm Thick Pvc Carpet Supply And Install 2.0 Mm Thick Vinyl Chloride Flooring Carpet (Make Approved By Nau Authority) In Strip Or Roll Form, Any Approved Shade And Color. Includes Labor, Materials, Adhesive, Wastage, And All Necessary Accessories As Directed By The Engineer-In-Charge., Providing And Fixing 6.0 Mm Thick Stone Plastic Composite Flooring Supply And Install 6.0 Mm Thick Stone Plastic Composite Flooring (Ceraite, Mohawk, Karndean, And Armstrong Flooring, Polywood, Exrodo -Nau Approved Brand) In Planks Sized 184 Mm X 1220 Mm, Core Density 1.95±0.05, Gloss Level 5-8, Any Approved Shade And Color. Includes Labor, Materials, Adhesive, Wastage, And All Accessories As Directed By The Engineer-In-Charge., Providing, Supplying & Installation Of Premium Wood Plastic Composite (Wpc) Panel Wall Cladding (Interior Grade, Elevation Purpose) Supply And Install Premium Interior-Grade Wpc Panels With Specified Material Properties, Dimensions, Color, And Finish As Per Design. Panels Shall Meet Required Density, Strength, And Fire Rating Standards. Structure Frame To Be Fabricated Onsite Using Aluminum Sections As Per Approved Design. Complete Installation Including Materials, Labor, And Accessories As Directed By The Engineer-In-Charge., Providing And Fixing Drywall Partition Using Non-Load Bearing Mr Gypsum Board / Cement Fiber Board / Calcium Silicate Board Steel Stud Partitions Supply And Install Non-Load Bearing Drywall Partitions With Steel Frame Comprising 0.55 Mm Thick, 48 Mm Wide Studs (Unequal Flanges 34.5 Mm & 37 Mm) And 0.55 Mm Thick, 50 Mm Wide Floor And Top Channels (Make Approved By Nau Authority). Floor Channels Fixed At 610 Mm Centers With Nylon Sleeves And Screws/Anchors; Studs Inserted At 600 Mm Centers And Cut 5 Mm Short For Alignment. Fix 12.5 Mm Thick Mr Gypsum Board (Make Approved By Nau Authority), Or 8 Mm Cement Bonded Particle Board (Make Approved By Nau Authority) / Calcium Silicate Board (Make Approved By Nau Authority), To Both Sides Of Frame With Self-Drilling Csk Screws At 200 Mm Centers, Maintaining 2 Mm Joint Gap. Screws Fixed Minimum 15 Mm From Edges And 40 Mm From Corners. Boards Staggered For Stability (610 Mm + 1220 Mm). Provide Cutouts In Studs For Electrical/Plumbing Services. Insert 50 Mm Thick Rockwool Insulation In Cavity (Paid Separately). Fixed Glass Windows (5 Mm Plain Glass With 20 Mm Wooden Beading), Doors, And Frames Paid Separately. Finish Joints With Compound And Fiber Tape. Apply Water-Based Primer, Putty, And Two Coats Of Distemper (Paid Separately). Work To Be Done In True Line, Level, And Good Finish As Directed By Engineer-In-Charge., Providing And Fixing Drywall Partition Using Non-Load Bearing 12Mm Thick Mr 303 Grade Plywood Steel Track Stud Partitions Supply And Install Non-Load Bearing Drywall Partitions With Steel Frame Comprising 0.55 Mm Thick, 48 Mm Wide Studs (Unequal Flanges 34.5 Mm & 37 Mm) And 0.55 Mm Thick, 50 Mm Wide Floor And Top Channels (Make Approved By Nau Authority). Floor Channels Fixed At 610 Mm Centers With Nylon Sleeves And Screws/Anchors; Studs Inserted At 600 Mm Centers And Cut 5 Mm Short For Alignment. Fix 12Mm Thick Mr 303 Grade Plywood (Make Approved By Nau Authority) To Both Sides Of Frame With Self-Drilling Csk Screws At 200 Mm Centers, Maintaining 2 Mm Joint Gap. Screws Fixed Minimum 15 Mm From Edges And 40 Mm From Corners. Boards Staggered For Stability (610 Mm + 1220 Mm). Provide Cutouts In Studs For Electrical/Plumbing Services. Insert 50 Mm Thick Rockwool Insulation In Cavity (Paid Separately). Fixed Glass Windows (5 Mm Plain Glass With 20 Mm Wooden Beading), Doors, And Frames Paid Separately. Finish Joints With Compound And Fiber Tape. Apply Water-Based Primer, Putty, And Two Coats Of Distemper (Paid Separately). Work To Be Done In True Line, Level, And Good Finish As Directed By Engineer-In-Charge., Providing And Fixing Drywall Acoustical Partition (Non-Load Bearing) Using Mr Gypsum Board, Cement Fiber Board, Or Calcium Silicate Board Steel Stud Partitions Assemble Non-Load Bearing Partition Frame On Site Using 0.55 Mm Thick, 48 Mm Wide Steel Studs With Unequal Flanges (34.5 Mm & 37 Mm) And 0.55 Mm Thick, 50 Mm Wide Floor And Top Channels (Make Approved By Nau Authority). Fix Floor Channels At 610 Mm Centers With Nylon Sleeves And Screws/Anchors; Insert Studs At 600 Mm Centers, Cut 5 Mm Short For Alignment. Web Cutouts Aligned For Services Electrical/ Plumbing). Fix 12.5 Mm Thick Non-Mr Gypsum Board (Make Approved By Nau Authority), 10 Mm Cement Bonded Particle Board (Make Approved By Nau Authority), Or 10 Mm Calcium Silicate Board (Make Approved By Nau Authority), Both Sides, With Self-Drilling Csk Screws At 200 Mm Centers. Maintain 2 Mm Gap Between Boards; Stagger Boards (610 Mm + 1220 Mm) For Strength. Screws Set Minimum 15 Mm From Edges And 40 Mm From Corners. Take Care At L And T Joints For Proper Fixing. Insert 50 Mm Thick Rockwool Insulation In Cavity For Acoustic And Thermal Performance (Paid Separately). Fixed Glass Windows (5 Mm Glass With 20 Mm Wooden Beading), Doors, And Frames Paid Separately. Finish Joints With Compound And Fiber Tape. Apply Water-Based Primer, One Coat Putty, And Two Coats Distemper (Paint Paid Separately). Complete Work In True Line, Level, And Good Finish As Per Engineer-In-Charge., Providing, Supplying & Installation Of 9/10 Mm Thick Membrane-Coated Stone Plastic Composite (Spc) Double-Screen Steel Track & Stud Partitions Assemble Partition Frame On Site Using 0.55 Mm Thick Cold-Rolled Galvanized Steel Sections (Make Approved By Nau Authority). Fix 0.55 Mm Thick Gi Floor And Top Channels (30X50x30 Mm) At 450/610 Mm Centers With Nylon Sleeves And Screws/Anchors. Insert 0.55 Mm Thick Gi Studs (34X48.5X37 Mm) At 450/600 Mm Centers; Cut Studs 5 Mm Short For Alignment. Provide Web Cutouts Aligned For Services. Use 9 Mm Membrane-Coated Spc Panels (Make Approved By Nau Authority) Fixed Both Sides Of Frame With Self-Drilling Csk Screws. Panels Feature 250 Mm Wide Multi-Chamber Hollow Sections With Tongue And Groove Joints. Cover Open Panel Edges With 9X28 Mm U-Shaped Or 25X25 Mm L-Shaped Pvc Sections. At Door/Window Openings, Use Reinforced Gi Head/Bottom Tracks With Seasoned Wood Supports (47X34 Mm); Studs Spaced Max 300 Mm. At Joints, Fix Panels Carefully With Inserted Junction Panels. Decorate Vertical And Ceiling Panel Joints With 35X35 Mm Double-Sided Or 25X30 Mm Single Cornice Sections Bonded Using Approved Cyanoacrylate Adhesive (Make Approved By Nau Authority). Complete Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing And Fixing 01Mm-02Mm Thick Vinyl Wallpaper Supply And Fix Waterproof Vinyl Wallpaper Of Brand Approved By Engineer In-Charge And Design On Drywall, Brick, Or Cement Sandwich Partitions On Any Other Location. Prepare Surfaces By Cleaning, Removing Dirt And Dents, And Smoothing As Per Manufacturer’S Standards. Use Standard Marine-Grade Adhesive For Installation. Rates Include Wastage. Complete Work To A Smooth Finish, True Line, And Level As Directed By Engineer-In-Charge., Providing And Fixing Wallpaper Supply And Fix Wallpaper Of Brand Approved By Engineer In-Charge And Design On Drywall, Brick, Or Cement Sandwich Partitions On Any Other Location. Prepare Surfaces By Cleaning, Removing Dirt And Dents, And Smoothing As Per Manufacturer’S Standards. Use Standard Marine-Grade Adhesive For Installation. Rates Include Wastage. Complete Work To A Smooth Finish, True Line, And Level As Directed By Engineer-In-Charge., Providing And Fixing Laminate On Partitions / Wall Paneling / Ceiling Supply And Fix 1 Mm Thick Laminate Of Approved Brand (Make Approved By Nau Authority) On Drywall, Wall Paneling, Or Cement Sandwich Partitions. Prepare Surfaces By Cleaning And Smoothing As Per Manufacturer’S Standards. Use Standard Marine-Grade Adhesive (Make Approved By Nau Authority). Rates Include Wastage. Complete Work To A Smooth Finish, True Line, And Level As Directed By Engineer-In-Charge., Providing And Placing Rock Wool Insulation Supply And Install 50 Mm Thick Rock Wool Slabs With 40 Kg/M³ Density Between Wall Structures And Panels Or Roofing And Ceiling Panels For Acoustic And Thermal Insulation. Work To Be Executed In True Line, Level, And Good Finish As Directed By Engineer-In-Charge., Providing And Supplying Paint Work On Wall, Partition, Cement Board, Plywood Or Any Other Location (Oil Paint Or Plastic Paint) Color Clean And Sand Partition Surface To Remove Dirt. Apply One Coat Of Primer (Make Approved By Nau Authority). Apply One Or More Coats Of Putty (Birla Or J.K. Laxmi) For A Smooth, Levelled Finish. Finish With Two Coats Of Plastic Paint Color (Inner Color) (Make Approved By Nau Authority). Work To Be Done In True Line, Level, And Good Finish As Directed By Engineer-In-Charge., Providing And Supplying Paint Work On Wall, Partition, Cement Board, Plywood Or Any Other Location (Royal Finish Or Velvet Paint) Clean And Sand The Surface To Remove Dirt. Apply One Coat Of Primer (Make Approved By Nau Authority). Apply One Or More Coats Of Putty (Birla Or J.K. Laxmi) For A Smooth, Levelled Finish. Finish With Two Coats Of Royal Finish Of Velvet Finish Category Paint (Make Approved By Nau Authority). Work To Be Executed In True Line, Level, And Good Finish As Directed By Engineer-In-Charge., Providing And Fixing Color Anodized / Powder Coated Aluminum Section Partition Supply And Fix Partly Paneled And Partly Glazed Aluminum Partitions Using Make Approved By Nau Authority Nau-Approved Anodized/Powder-Coated Aluminum Sections.Bottom, Top, And Side Sections: Single Member, 2 Mm Thick, 63.30 X 38.00 Mm, Weight 1.08–1.12 Kg/M.Internal Vertical/Horizontal Members: Double Partition Member, 2 Mm Thick, 63.50 X 38.1 Mm, Weight 1.08–1.13 Kg/M. Glazing Clips: 0.55 Mm Thick, 19 X 17.20 Mm, Jumbo Epdm Rubber Gasket. Infill: 5 Mm Clear/Colored Glass (Saint Gobain/Modiguard) And 3 Mm Aluminum Composite Panels (Make Approved By Nau Authority). Use Weatherproof Silicon Sealant For All Peripheral Gaps. Complete Installation To Be Done In Good Shape And Finish As Per Engineer-In-Charge Instructions., Providing, Supplying & Installation Of 60 Mm Thick Solid Pvc Double Screen Steel Track & Stud Partition (Full Height) Assemble Partition Frame Onsite Using 0.55 Mm Thick Cold-Rolled Galvanized Steel Sections (Make Approved By Nau Authority). Fix 5 Mm (±0.25 Mm) Thick Prelaminated Solid Pvc Panels (Make Approved By Nau Authority) On Both Sides Using Self-Drilling Screws And Solvent Cement Adhesive. Fix 0.55 Mm Thick G.I. Floor And Top Channels (30 X 50 X 30 Mm) As Per Layout With Nylon Sleeves And Screws/Anchors At 450/610 Mm Centers. Insert 0.55 Mm Thick G.I. Studs (34 X 48.5 X 37 Mm) At 600/450 Mm Centers; Cut 5 Mm Shorter For Proper Leveling. Provide Aligned Cutouts In Studs For Services. For Door/Window Openings, Reinforce Head And Bottom Tracks With 0.55 Mm G.I. Channels And Seasoned Wood (47 X 34 Mm). Stud Spacing At Openings Max 300 Mm. Fix 40 Mm Wide, 5 Mm Thick Pvc Strips To Floor, Head Channel, And Studs. Fix 5 Mm (±0.25 Mm), 30 Mm Wide Solid Pvc Sheets (Density 600 Kg/M³, Make Approved By Nau Authority) On Stud Faces With Screws. Clad Both Sides With 5 Mm (±0.25 Mm) Prelaminated Solid Pvc Sheets Using Solvent Cement Adhesive. At “L” And “T” Joints, Insert Panels Between Studs. Cover All Open Edges With Hot-Bent Molded 5 Mm Thick Prelaminated Pvc “C” Or “L” Shaped Channels. Complete All Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installation Of 60 Mm Thick Solid Pvc Double Screen Low Height Partition Assemble Partition Frame Onsite Using 2.0 Mm Thick Galvanized Steel Rectangular/Square Sections (50X25 Mm Or 50X50 Mm, Make Approved By Nau Authority) As Main Framing, And 0.6 Mm Thick Cold-Rolled Galvanized Steel Sections (Make Approved By Nau Authority) As Secondary Framing. All Framing Sections Shall Be Clad On Both Faces With 5 Mm Thick X 50 Mm Wide Prelaminated Pvc Panel Strips (Make Approved By Nau Authority) Fixed With Self-Drilling Screws. Fix 5 Mm (±0.15 Mm) Thick Prelaminated Pvc Panels (Make Approved By Nau Authority) On Both Sides Of The Frame, With 40 Mm Thick High-Density Expanded Polystyrene Insulation Placed In The Cavity, Adhered Using Solvent Cement Adhesive. Finish All Exposed Edges With Heat-Molded/Bent 5 Mm (±0.25 Mm) Thick Prelaminated Solid Pvc “C” Channels (Make Approved By Nau Authority), Sized 50X100 Mm With Feathered Edge At The Floor, And 50X75 Mm Plain/Feathered Edge Channels On Other Exposed Edges, Fixed Using Solvent Cement Adhesive. Complete All Work In True Line, Level, And Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Premium Shade Exterior Grade Double Screen Steel Track & Stud Partitions Assemble Partition Frame Onsite Using Galvanized Steel Sections. Fix 3 Mm Thick Premium Shade Wood/Marble Design Exterior Grade Aluminum Composite Panels (Make Approved By Nau Authority) On Both Sides Of Frame Using 3M Self-Adhesive Tape And Dow Corning Silicone. Fix 0.5 Mm Thick G.I. Cold-Rolled Floor Channels (30X50x30 Mm) At 450/610 Mm Centers With Nylon Sleeves And Screws Or Anchors. Fix 0.55 Mm Thick G.I. Top Channels (30X50x30 Mm) Plumb And Aligned With Floor Channels. Insert 0.55 Mm Thick G.I. Studs (34X48.5X37 Mm) At 601/611 Mm Centers; Studs Cut 5 Mm Shorter For Leveling. Provide Cutouts In Stud Webs For Services. At Door/Window Openings, Reinforce Head And Bottom Tracks With 0.55 Mm Thick G.I. Channels (30X50x30 Mm) And Seasoned Wood (47X34 Mm). Maintain Stud Spacing = 300 Mm At Openings. Fix 3/4 Mm Thick Aluminum Composite Panels On Frame Using Self-Adhesive Tape And Silicone As Per Approved Design And Color. Make “L” And “T” Joints With Care To Insert Panels Between Studs. Cover All Open Ends With Grooved And Folded Aluminum Composite Panel Sections. If Required, Fix Minimum 8 Mm Thick Glass Windows. Sliding Windows, Door Frames, And Doors Paid Separately As Per Approved Rates. Complete Work With True Lines, Level, And Aesthetic Finish As Directed By Engineer-In-Charge., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Plain Shade Exterior Grade Double Screen Steel Track & Stud Partitions Assemble Partition Frame Onsite Using Galvanized Steel Sections. Fix 3 Mm Thick Plain Shade Exterior Grade Aluminum Composite Panels (Make Approved By Nau Authority) On Both Sides Of The Frame Using 3M Brand Self-Adhesive Tape And Dow Corning Silicone. Fix Cold Rolled Form 0.5 Mm Thick G.I. Floor Channels (30 Mm X 50 Mm X 30 Mm) As Per Layout At 450 Mm / 610 Mm Centers With Nylon Sleeves And Screws Or Anchor Fasteners (6 Mm Or 8 Mm Diameter). Fix Cold Rolled Form 0.55 Mm Thick G.I. Top Channels (30 Mm X 50 Mm X 30 Mm) To Slab Or Soffit, Plumb And Aligned With Floor Channels. Insert Cold Rolled Form 0.55 Mm Thick G.I. Studs (34 Mm X 48.5 Mm X 37 Mm) Into Floor Channels At 601 Mm / 611 Mm Centers. Studs Cut 5 Mm Shorter For Level Alignment. Provide Stud Web Cutouts Aligned For Service Pipes (Electrical/Plumbing). At Door/Window Openings, Reinforce Head And Bottom Tracks With 0.55 Mm Thick G.I. Channels (30 Mm X 50 Mm X 30 Mm) And Seasoned Wood (47 Mm X 34 Mm). Maintain Stud Spacing = 300 Mm At Openings. Fix 3/4 Mm Thick Aluminum Composite Panels On Frame Using Self-Adhesive Tape And Silicone Per Approved Design And Color. Ensure “L” And “T” Joints Have Properly Inserted Panels Between Studs. Cover All Open Ends With Grooved And Folded Aluminum Composite Panel Sections Shaped As Required. If Fixed Glass Windows Are Required, Use Minimum 8 Mm Thick Glass. Sliding Windows, Door Frames, And Doors To Be Paid Separately As Per Approved Rates. Complete Installation Maintaining Aesthetic Quality, True Lines, And Levels As Directed By Engineer-In-Charge., Providing And Fixing Low Height Modular Partition For Office Cubicles The Partition Structure Shall Be Fabricated Using Powder-Coated Or Color-Anodized Extruded Aluminum Sections (Make Approved By Nau Authority). Base Frame: Section Code G-2989, Size 60 Mm X 19.5 Mm, Average Weight 420 Grams Per Running Meter (Rmt). Vertical Tracks (Both Sides): Section Code G-2984, Size 60 Mm X 19 Mm, Average Weight 460 Grams Per Rmt. Raceway Provision: Internal Bottom Section To Be G-2989 (60 Mm X 19.5 Mm, 420 G/Rmt) With Raceway Cap G-2993 (145 Mm X 1.7 Mm, 770 G/Rmt). Internal Horizontal Sections: G-2988 (60 Mm X 5.5 Mm, 321 G/Rmt) And G-2986 (60 Mm X 7.2 Mm, 290 G/Rmt) For Supporting Glass, Pin-Up Boards, Or Marker Boards At The Top. Top And Side Covering Sections: G-2983 (60 Mm X 7.7 Mm, 243 G/Rmt). Partition Connectivity: Use Gx 201 And Gx 207 L-Shaped Connectors For Right-Angle Junctions. Level Adjustment: Provide Floor-Adjusting Device Screws With Bottom Polymeric Wheel Assembly Gx 203 + Gx 204 For Height Leveling Of The Partition. Desk Panel Support: Aluminum Section G-2990 (46 Mm X 12 Mm, 280 G/M) To Be Inserted On Front And Side Partitions At Required Height To Support Desk Panels. Partition Panels: Both Sides Shall Be Clad With Either 6 Mm Thick Prelaminated Cement Bonded Particle Board Or 6 Mm Thick Glass (Approved Brand). Pin-Up Boards Or Marker Boards To Be Provided As Required. Entire Installation To Be Executed Maintaining True Lines, Levels, And Aesthetic Values As Directed By The Engineer-In-Charge., Providing And Fixing High Height Partly Paneled & Glazed Modular Partition For Office: Supply And Installation Of Self-Standing High-Height Modular Partitions Made From Powder-Coated Or Color-Anodized Aluminum Sections Make Approved By Nau Authority • Base Frame: Combination Of G-007 (56X40 Mm, 452 G/Rmt) And G-058 (77.8X26.9 Mm, 498 G/Rmt). • Vertical & Horizontal Divisions: G-052 Sections (77.8X18 Mm, 613 G/Rmt) Spaced At Max 1100 Mm Centers. • Panels: 6 Mm Thick Prelaminated Cement Bonded Particle Board Or 6 Mm Thick Glass With Epdm Gaskets (Gehc2, G050 - 18X15.8 Mm, 108 G/Rmt & G066 - 41.2X11.4 Mm, 203 G/Rmt). • Joints: O Three/Four-Way: G046 (80X80 Mm, 1387 G/Rmt) O L-Shaped: G063 (80X80 Mm, 1200 G/Rmt) • Door Frame: G043 (80X25 Mm, 1300 G/Rmt). Work To Be Executed Maintaining True Lines, Levels, And Aesthetic Standards As Directed., Providing And Fixing High Height Fully Double Glazed Modular Partition For Office: Supply And Installation Of High-Height Fully Double-Glazed Modular Partition Using Powder-Coated Or Anodized Aluminum Sections (Make Approved By Nau Authority) Main Frame: G-007 (56×40 Mm, 452 G/Rmt) And G-058 (77.8×26.9 Mm, 498 G/Rmt). Vertical/Horizontal Divisions: G-052 (77.8×18 Mm, 613 G/Rmt). Glazing: Both Sides With 6 Mm Toughened Glass Fixed With Epdm Gaskets Gehc2, G050 (18×15.8 Mm, 108 G/Rmt), And G066 (41.2×11.4 Mm, 203 G/Rmt). Junctions: • Three/Four-Way: G046 (80×80 Mm, 1387 G/Rmt) • L-Joint: G063 (80×80 Mm, 1200 G/Rmt) All Work Shall Be Completed In Proper Alignment And Finish, As Per The Instructions Of The Engineer-In-Charge., Providing And Fixing Modular Door (Partly Paneled/ Fully Glazed) For Office: Supply And Installation Of Modular Door (Partly Paneled Or Fully Glazed) With Powder-Coated Or Anodized Aluminum Frame (Make Approved By Nau Authority) Door Frame: G-043 (80×40 Mm, 1295 G/Rmt) Shutter Frame Sections: G-062 + S-58 (50×50 Mm, 990 G/Rmt) Infill: • Fully Glazed: 10 Mm Thick Toughened Glass With Epdm Gasket Gehc2 • Partly Paneled: 18 Mm Thick Prelaminated Particle Board Fittings: Heavy-Duty Hinges (4 Nos., 150×25×25×5 Mm), Two Handles, Door Stay, And Locking System Of Approved Make Work To Be Executed In Line, Level, And Fine Finish As Per Engineer-In-Charge’S Direction., Providing And Applying Decorative Glass Film: Supplying And Applying Decorative Glass Film Of Approved Brand, Design, And Quality On Glass Surfaces As Directed By The Authority. Work To Be Completed In Proper Alignment, Ensuring A Smooth Finish And Aesthetic Appearance., Providing And Fixing Work Top: Supplying And Fixing Work Top For Low-Height Modular Cubicles Using 30 Mm Thick Marine-Grade Ply Or Cement Bonded Particle Board, Finished With 1 Mm Thick Laminate On Top And 0.8 Mm Laminate On The Underside. Edges To Be Finished With 2 Mm Pvc Edge Banding And Supported With Powder-Coated/Anodized Aluminum Section (G-2990, 40×12 Mm, Avg. Wt. 280 Gm/Rmt) Of “Gilt Edge” Or Equivalent Brand Approved By Nau Authority. Work To Be Completed In Line And Level, Maintaining Aesthetic Finish As Directed., Providing And Fixing Computer Keyboard Tray With Mouse Holder: Supplying And Fixing Powder-Coated Metal Keyboard Tray With Mouse Holder, Mounted Under Work Top Of Low-Height Modular Cubicles With Smooth Sliding Runners And Necessary Hardware. Work To Be Completed In Proper Alignment And Aesthetic Finish As Directed., Providing And Fixing Computer Cpu Stand: Supplying And Fixing Under-Table Mounted Cpu Stand, Powder-Coated, With Swivel And Pull-Out Feature, With Or Without Wheels As Required. Installation To Be Completed With Proper Alignment And Aesthetic Finish As Directed., Providing And Fixing Workstation Pedestal Drawer Unit: Supplying And Installing Pedestal Drawer Unit Made From 18 Mm Prelaminated Wood-Based Particle Board Or 18 Mm Prelaminated Cement Bonded Board With 2 Mm Edge Beading. Unit To Include Required Drawers/Shutters With High-Quality Runners, Handles, And Locks. Finished In Proper Alignment And Aesthetic Quality As Directed By Authority., Providing And Fixing 75 Mm Cement Sandwich Panel Partition: Supplying And Installing 75 Mm Thick Cement Sandwich Panels (Make Approved By Nau Authority) With Tongue-And-Groove Joint System, Made Of Fiber-Reinforced Cement Sheets Enclosing A Lightweight Core Of Portland Cement, Binders, And Siliceous Aggregates. Panels To Be Fixed In 1.0 Mm Thick Cold-Rolled Gi “C” Channels (32X51x35 Mm), Anchored To Floor And Ceiling Using 100X8 Mm Screws And Pvc Plugs At 450 Mm C/C. Corners (“L”, “T”, “C” Junctions) To Have 2 Mm Thick 75X75 Mm Or 75X125 Mm Gi Angles Secured With 75X10 Mm Bolts And Washers. Openings (Doors/Windows) To Be Framed With Gi “C” Channel And 60X25 Mm Seasoned Teak Wood Battens. Fixed 5 Mm Glass Windows To Be Provided Where Required. Pillars, If Required, Shall Be 75X75 Mm Ms Square Pipes With 200X200x5 Mm Base Plates, Fixed With 100X15 Mm Anchor Bolts. All Panel Gaps To Be Filled With Roff Or Equivalent Acrylic Putty. Finish With Exterior-Grade Weatherproof Paint On The Outside And Interior-Grade Distemper On The Inside. All Work To Be Executed In True Line, Plumb, And Good Finish As Directed By The Engineer-In-Charge., Providing, Supplying & Installing Modular Workstation/Table (Shared Type Up To 1200 Mm Width): Modular Shared-Type Workstation Comprising Double-Leg Frame Made Of Powder-Coated/Anodized Extruded Aluminum Sections, Tapering From 80X40 Mm (Top) To 40X40 Mm (Bottom), 700 Mm In Height, Inclined At 9° From Vertical With 3° Tapered Legs. Abs Plastic Mounting Caps To Be Fixed On Legs For Top Panel Support. Legs To Be Connected With 1200 Mm Wide Horizontal Aluminum Gable Frame Members. Worktop Shall Be 25 Mm Thick Prelaminated Mdf/Ply With Four-Side Edge Banding. Divider Panels, If Required, Will Be Paid Separately. Entire Work To Be Completed In Line, Level, And Design As Per Engineer-In-Charges Direction. Payment To Be Made As Per Actual Top Area., Providing, Supplying & Installing Modular Workstation Partition: Modular Workstation Partition Using Color-Coated/Anodized Extruded Aluminum Main Sections (28X14 Mm) And End Sections (28X17 Mm) With 90° Connectors And Abs End Caps. Infill Panels To Consist Of Soft Boards On Both Sides, Prelaminated Panels, Or Glass As Per Design. Work To Be Completed In True Line, Level, And Finish As Directed By The Engineer-In-Charge., Providing, Supplying & Fixing Conference Table: Supply And Fix Conference Tables (Straight, U, C, Or Oval Shape) Made From 18 Mm Thick Moisture-Resistant Isi-Marked Ply (Make Approved By Nau Authority) For All Panels (Vertical, Horizontal, Front). Panels To Be Assembled With Screws And Marine-Grade Adhesive Make Approved By Nau Authority). Both Sides Covered With 1 Mm Thick Approved Laminate (Make Approved By Nau Authority). Peripheral Edges Thickened With Mr Grade Ply Up To 36 Mm Where Required, Finished With 2 Mm Pvc Edge Tape Or Teak Wood Molding. Provision For Audio/Electrical Cable Tracks And Cable Manager As Per Design. Work To Be Completed With Good Finish And Aesthetics As Directed. Rates Based On Tabletop Area., Pproviding, Supplying & Installing Modular Workstation/Table (Non-Shared, Up To 680 Mm X 1200 Mm): Supply And Install Modular Non-Shared Workstation/Table With Four Legs Made Of Color-Coated Or Anodized Extruded Aluminum Sections (80X40 Mm Tapering To 40X40 Mm, 700 Mm Height, Legs Angled 9° From Vertical). Legs Fitted With Abs Mounting Caps To Support The Top. Legs Connected By 600 Mm Wide Gable Frames And Joined With Up To 1200 Mm Wide Aluminum Cross Beams. Tabletop To Be 25 Mm Thick Four-Side Edge-Banded Prelaminated Mdf Or Ply. Work To Be Executed In True Line And Finish As Directed. Payment Based On Tabletop Area., Providing, Supplying & Installing 75 Mm Thick Plywood Double-Screen Partitions With Aluminium Pipe Frame (Full Height): Partition Assembled Onsite Using 50X25 Mm And 50X50 Mm, 18-Gauge Aluminium Hollow Pipes Forming A 600X600 Mm Grid Frame. Both Sides Fixed With 12 Mm Mr Grade Plywood (Approved Brand) Using Self-Drilling Screws. Vertical And Horizontal Pipes Connected With 3 Mm Thick Powder-Coated Aluminium L Brackets. Door/Window Openings Included As Required With Neat Finishing Of Edges. Laminate Or Other Cladding Paid Separately. Work To Be Done In True Line And Finish As Directed., Providing, Supplying & Installing 75 Mm Thick Plywood Double-Screen Partitions With Aluminium Pipe Frame (Low Height – 1200 Mm): Partition Framed With 50X25 Mm & 50X50 Mm, 18-Gauge Aluminium Hollow Pipes In 600X600 Mm Grid. Both Sides Fixed With 12 Mm Plywood (Make Approved By Nau Authority) Using Self-Drilling Screws. Vertical And Horizontal Pipes Connected With 3 Mm Powder-Coated Aluminium L Brackets. Top Covered With 12 Mm Plywood Fixed To Frame. Height Fixed At 1200 Mm. Laminate Or Other Cladding Paid Separately. Work To Be Done In True Line And Finish As Directed., Providing, Supplying & Installing 75 Mm Thick Double-Screen Plywood Partitions With Aluminium Pipe Frame: Partition Framed With 50X25 Mm & 50X50 Mm, 18-Gauge Aluminium Hollow Pipes In 600X600 Mm Grid. Both Sides Clad With 12 Mm Plywood (Make Approved By Nau Authority) Fixed With Self-Drilling Screws. Vertical And Horizontal Pipes Connected With 3 Mm Powder-Coated Aluminium L Brackets. Provision For Doors, Fixed Glass, And Windows As Required. Borders And Edges Finished True To Line And Level. Laminate Or Other Cladding Paid Separately. Work Executed As Directed By Engineer., Providing & Fixing Black Slim Profile Glazing: Supply And Fix 15Mm X 20Mm Matte Black Aluminum Profile To Hold 12Mm Thick Tempered Glass For Partition Walls. Profiles Fixed With Stainless Steel Patch Fittings As Per Design. Exposed Glass Edges Polished To High-Quality Finish., Providing & Fixing Black Slim Profile Glazed Door: Supply And Fix 15Mm X 20Mm Matte Black Aluminum Profile To Hold 12Mm Thick Tempered Glass Door. Profile Fixed With Stainless Steel Patch Fittings As Per Design. Glass Edges Polished To Superior Finish., Providing & Fixing Prelaminated 18Mm Solid Pvc Cabinet Shutter With Framing: Supply And Fix 18Mm Thick Solid Pvc Prelaminated Shutter With 1.2Mm Pvc Laminate (Density 900 Kg/M³) By Approved Brand (Make Approved By Nau Authority). Frame Edges And Shutter Edges To Be Covered With Prelaminated Pvc Panels And Rehu Lipping. Shutters Fixed To Carcass With Approved Hinges (Make Approved By Nau Authority) And 75Mm Stainless Steel Handles. Work To Be Done In True Line And Finish As Directed., Providing & Fixing Prelaminated 18Mm Solid Pvc Cabinet/Platform Shutter Without Framing: Supply And Fix 18Mm Thick Prelaminated Pvc Shutters (Make Approved By Nau Authority, Density 550 Kg/M³) Cut To Size. All Edges Lipped With Rehu Or Equivalent. Shutters Fixed To Carcasses With Approved Hinges (Make Approved By Nau Authority) And Fitted With 75Mm Stainless Steel Handles. Work To Be Executed In True Line And Finish As Directed., Providing & Fixing 18Mm Mr 303 Grade Plywood Cabinet Shutter With Laminate With Framing: Supply And Fix 18Mm Thick Mr 303 Grade Plywood Shutter With 1Mm Laminate On Exposed Side & 0.8Mm Liner Laminate By Approved Brand (Make Approved By Nau Authority). Frame Edges And Shutter Edges To Be Covered With Pvc Based Edge Band Tap. Shutters Fixed To Carcass With Approved Hinges (Make Approved By Nau Authority) And 75Mm Stainless Steel Handles. Work To Be Done In True Line And Finish As Directed., Providing & Fixing 18Mm Mr 303 Grade Plywood Cabinet Shutter With Laminate Without Framing: Supply And Fix 18Mm Thick Water Proof Plywood Shutters With Laminate (Make Approved By Nau Authority, Density 550 Kg/M³) Cut To Size. All Edges Lipped With Pvc Edge Band Tap. Shutters Fixed To Carcasses With Approved Hinges (Make Approved By Nau Authority) And Fitted With 75Mm Stainless Steel Handles. Work To Be Executed In True Line And Finish As Directed., Providing & Fixing Premium Shade Acp Cladded Cabinet/Platform Shutter Without Framing: Supply And Fix 3Mm Thick Plain Color Acp Shutters (Make Approved By Nau Authority) With 18Mm Acp Edge Tray. Fix 15Mm Thick Solid Pvc/Wpc Panel (Make Approved By Nau Authority, Density 550 Kg/M³) Inside Acp Tray Using Dow Corning Silicone. Attach Shutters To Carcasses With Approved Hinges (Make Approved By Nau Authority) And Fit 75Mm Stainless Steel Handles. Work To Be Executed In True Line And Finish As Directed., Providing & Fixing Plain Color Acp Cladded Cabinet/Platform Shutter Without Framing: Supply And Fix 3Mm Thick Plain Color Acp Panel (Make Approved By Nau Authority) With 18Mm Acp Edge Tray. Insert 15Mm Thick Solid Pvc/Wpc Panel (Make Approved By Nau Authority, Density 550 Kg/M³) Fixed With Dow Corning Silicone. Attach To Carcasses Using Approved Hinges (Make Approved By Nau Authority) And Fit 75Mm Stainless Steel Handles. Work To Be Done In True Line And Finish As Directed., Providing, Supplying & Installing Solid Pvc Shutter With Frame: Supply And Install 18Mm Thick Solid Pvc Frame (Density 600 Kg/M³, Make Approved By Nau Authority) With Edges Covered By 1.2Mm Thick Pvc Laminate “C” Channel (Density 900 Kg/M³) Fixed With Solvent Cement. Shutter Made Of 18Mm Solid Pvc Panel Clad With 1.2Mm Pvc Laminate, Edges Fully Covered Forming A Tray. Attach Shutter To Frame Using Approved Hinges (Make Approved By Nau Authority) And Anti-Corrosive Screws. Provide 75/100/150/200Mm Stainless Steel Handles And Locking System. Work To Be Done In True Line And Finish As Directed., Providing, Supplying & Installing Solid Pvc Shutter With 1.2Mm Pvc Laminate To Pvc/Cement Bonded Particle Board Carcasses: Supply And Fix 18Mm Thick Solid Pvc Panel Clad With 1.2Mm Pvc Laminate (Make Approved By Nau Authority, Nau Approved). Edges Covered With 1.2Mm Pvc Laminate Tray Or 2Mm Thick 18Mm Wide Rehu Edge Banding Tape. Attach Shutters To Carcasses Using Approved Hinges (Make Approved By Nau Authority) And Anti-Corrosive Screws. Provide 75Mm X 8Mm Stainless Steel Handles Of Approved Brand. Work To Be Executed In True Line And Finish As Directed., Providing, Supplying & Installing Solid Pvc Shutter Without Frame For Cupboard/Platform Carcasses: Supply And Fix 15Mm Thick Solid Pvc Panel Clad With 5Mm Prelaminated Solid Pvc (Make Approved By Nau Authority, Nau Approved), Edges Heat-Molded To Form A Tray. Attach To Carcasses With Approved Hinges (Make Approved By Nau Authority Or Equivalent) And Anticorrosive Screws. Provide 75Mm X 8Mm Stainless Steel Handles Of Approved Brand. Work To Be Done In True Line And Finish As Directed., Providing, Supplying & Installing Solid Pvc Cupboard/Platform Shutter With Frame: Supply And Fix 15Mm Thick Solid Pvc Frame (Make Approved By Nau Authority) With Edges Covered By Heat-Molded 5Mm Prelaminated Solid Pvc “C” Channel Using Solvent Adhesive. Shutter Made Of 15Mm Solid Pvc Panel Clad With 5Mm Prelaminated Solid Pvc, Edges Heat Molded To Form A Tray. Fix Shutters To Frame With Approved Hinges (Make Approved By Nau Authority) And Anticorrosive Screws. Provide Stainless Steel Handles (75–200Mm) And Locking System. Execute Work In True Line And Finish As Directed., Providing & Fixing Premium Shade (Wood/Marble Finish) Acp Cabinet/Platform Shutter With Framing: Supply And Fix Seasoned Teak Wood Or 40Mm Thick Solid Pvc/Wpc Framing (Make Approved By Nau Authority) Fixed To Existing Structure With Suitable Screws. Shutter Made Of 3Mm Thick Premium Shade Acp Panel (Make Approved By Nau Authority) With All Edges Formed As An 18Mm High Acp Tray. Insert 15Mm Thick Solid Pvc/Wpc Panel (Make Approved By Nau Authority) Fixed To Acp Tray Using Dow Corning Silicon Adhesive. Attach Shutters To Framing With Approved Hinges (Make Approved By Nau Authority) And Provide 75Mm X 8Mm Stainless Steel Handles. Execute Work In True Line And Finish As Directed., Providing & Fixing Plain Color Acp Cladded Cabinet/Platform Shutter With Framing: Supply And Fix Seasoned Teak Wood Or 40Mm Thick Solid Pvc/Wpc Framing (Make Approved By Nau Authority) Secured To Existing Structure With Suitable Screws. Shutter Made Of 3Mm Thick Plain Color Acp Panel (Make Approved By Nau Authority) With All Edges Formed As 18Mm High Acp Tray. Insert 15Mm Thick Solid Pvc/Wpc Panel Fixed To Acp Tray Using Dow Corning Silicon Adhesive. Attach Shutters To Framing With Approved Hinges (Make Approved By Nau Authority) And 75Mm X 8Mm Stainless Steel Handles. Execute Work In True Line And Finish As Directed., Providing, Supplying & Installation Of Membrane Coated Multi-Chambered Hollow Pvc Cabinet/Loft Shutter: Supply And Install Membrane Coated Heavy-Grade Multi-Chambered Hollow Pvc Sections (Make Approved By Nau Authority) With Minimum 1.8Mm Wall Thickness. Frame Sections (65X24mm Or 32X42mm) Reinforced With Seasoned Wood And Fixed Using 0.5Mm Aluminum L-Section. Outer Frame Corners Reinforced With Polymeric Corner Blocks (200X85x25mm). Shutter Frames Of 40X24mm Or 30X60mm Pvc Sections With Polymeric Corner Blocks. Infill Panel: 20Mm Thick Multi-Chambered Pvc Section In One Piece. Optional 5Mm Plain Glass Fixed With 15X20mm Section. Reinforced Hinges (60X20x25mm Stainless Steel) Fixed Through Polymeric Reinforcement. Each Shutter Fitted With Stainless Steel Handle (75X6mm) And Magnetic Catch. Joints Sealed With Adhesive And Silicone Sealant At Gaps. Work Executed In True Line And Finish As Directed., Providing, Supplying & Installation Of Lab Platform Carcasses Using 20Mm Thick Cement Board With Granite Top: Supply And Fix Lab Platform Carcasses Using 20Mm Thick Cement Compressed Particle Board (Make Approved By Nau Authority) For Top, Sides, Bottom, And Shelving; Backing Panel 8Mm Thick. Panels Assembled With Anti-Corrosive Screws And Adhesive, Ensuring True Line, Level, And Right Angles. Front Skirting Of Required Size Provided. Edges Finished With 5Mm Thick X 20Mm Seasoned Teak Batten Or 2Mm Thick X 20Mm Edge Banding Tape. Vertical Panels To Extend To Floor For Load Support. Fabricate Openings For Sink, Keyboard, And Leg Room As Required. Top Finished With 15Mm Thick Approved Granite Stone Fixed With Mortar/Adhesive; Edges Rounded And Polished. Skirting And Exposed Sides Clad With Matching Granite Material. All Panels Laminated With Approved Liner-Grade Laminate. Work Completed True To Line, Level, And Aesthetic Standards As Directed., Providing, Supplying & Installation Of Lab Platform Carcasses Using 18Mm Thick Mr 303 Grade Plywood With Granite Top: Supply And Fix Lab Platform Carcasses Using 18Mm Thick Mr 303 Grade Plywood (Make Approved By Nau Authority) For Top, Sides, Bottom, And Shelving; Backing Panel 12Mm Thick Mr 303 Grade Plywood. Panels Assembled With Anti-Corrosive Screws And Adhesive, Ensuring True Line, Level, And Right Angles. Front Skirting Of Required Size Provided. Edges Finished With 2Mm Thick X 20Mm Edge Banding Tape. Vertical Panels To Extend To Floor For Load Support. Fabricate Openings For Sink, Keyboard, And Leg Room As Required. Top Finished With 15Mm Thick Approved Granite Stone Fixed With Mortar/Adhesive; Edges Rounded And Polished. Skirting And Exposed Sides Clad With Matching Granite Material. All Panels Laminated With Approved Liner-Grade Laminate. Work Completed True To Line, Level, And Aesthetic Standards As Directed., Providing, Supplying & Installation Of Lab Platform Carcasses Using 20Mm Thick Cement Board With Laminate Top: Supply And Fix Lab Platform Carcasses Using 20Mm Thick Cement Compressed Particle Board (Make Approved By Nau Authority) For Top, Sides, Bottom, And Shelving; Backing Panel 8Mm Thick. Panels Assembled With Anti-Corrosive Screws And Adhesive, Ensuring True Line, Level, And Right Angles. Front Skirting And Edges Finished With 5Mm Thick X 20Mm Teak Wood Batten. Vertical Panels To Extend To Floor For Load Support. Fabricate Openings For Sink, Keyboard, And Leg Room As Required. Top Finished With 1.0Mm Thick Approved Laminate (Make Approved By Nau Authority) Fixed With Marine-Grade Adhesive. Front Edge Rounded And Polished. Skirting And Exposed Sides Clad With Same Laminate. All Panels Laminated With Approved Liner-Grade Laminate. Work Executed As Per True Line, Level, And Aesthetic Standards Directed By Engineer., Providing, Supplying & Installation Of Lab Platform Carcasses Using 18Mm Thick Mr 303 Grade Plywood With Laminate Top: Supply And Fix Lab Platform Carcasses Using 18Mm Thick Mr 303 Grade Plywood (Make Approved By Nau Authority) For Top, Sides, Bottom, And Shelving; Backing Panel 12Mm Thick. Panels Assembled With Anti-Corrosive Screws And Adhesive, Ensuring True Line, Level, And Right Angles. Front Skirting And Edges Finished With 5Mm Thick X 20Mm Teak Wood Batten. Vertical Panels To Extend To Floor For Load Support. Fabricate Openings For Sink, Keyboard, And Leg Room As Required. Top Finished With 1.0Mm Thick Approved Laminate (Make Approved By Nau Authority) Fixed With Marine-Grade Adhesive. Front Edge Rounded And Polished. Skirting And Exposed Sides Clad With Same Laminate. All Panels Laminated With Approved Liner-Grade Laminate. Work Executed As Per True Line, Level, And Aesthetic Standards Directed By Engineer., Providing, Supplying & Installation Of Lab Platform Carcasses With Prelaminated Cement Bonded Particle Board: Supply And Fix Lab Platform Carcasses Using 18Mm And 8Mm Thick Prelaminated Cement Bonded Particle Board (Make Approved By Nau Authority) For Top, Sides, Bottom, Shelving, And Backing Panels. Assemble With Knock-Down Hardware (Make Approved By Nau Authority), Anti-Corrosive Screws, And Adhesive, Ensuring True Line, Level, And Right Angles. Front Edges Finished With 5Mm Thick X 20Mm Teak Wood Batten. Vertical Panels To Extend To Floor For Load Support. Fabricate Openings For Sink, Keyboard, And Leg Room As Required. Platform Top To Have 1.0Mm Thick Approved Laminate (Make Approved By Nau Authority) Over 8Mm Cement Bonded Board, Fixed With Marine-Grade Adhesive. Front Edges Rounded And Polished. Skirting And Exposed Sides Clad With Same Laminate. Entire Work To Be Executed As Directed Maintaining Finish And Aesthetics., Providing, Supplying & Installation Of Solid Pvc Kitchen/Lab/Service Platform Carcasses With Granite Top: Supply And Fix Platform Carcasses Of Dimensionally Stable 18Mm ±0.7Mm Thick Solid Pvc Panels (Density =550 Kg/M³) From Iso 9001 Certified Brand Make Approved By Nau Authority. Assemble All Panels (Top, Sides, Bottom, Shelving, Backing) With Anti-Corrosive Self-Drilling Screws And Solvent Adhesive As Per Manufacturer. Vertical Panels Spaced Max 700Mm For Load Support. Front Edge Doubled With 50Mm X 18Mm Solid Board Strip. All Open Edges Lipped With 18Mm X 1Mm Edge Banding Tape. Platform Top With Minimum 15Mm Thick Approved Granite Fixed With Adhesive. Front And Side Edges Rounded And Polished. Skirting And Exposed Sides Clad With Matching Granite. Work Executed As Per Manufacturer’S Guidelines, Ensuring True Level, Finish, And Strength As Directed., Providing, Supplying & Installation Of Solid Pvc Kitchen/Lab/Service Platform Carcasses With Pvc Laminate Top: Supply And Fix Platform Carcasses Of 18Mm ±0.7Mm Thick Solid Pvc Panels (Density =600 Kg/M³) From Iso 9001 Certified Brand Make Approved By Nau Authority. Assemble All Panels (Top, Sides, Bottom, Shelving, Backing) Using Anti-Corrosive Self-Drilling Screws And Solvent Adhesive As Per Manufacturer. Vertical Panels Spaced Max 700Mm For Load Support. Front Edge Doubled With 50Mm X 18Mm Solid Board Strip. All Open Edges Lipped With 18Mm X 1Mm Edge Banding Tape. The 18Mm Thick Top Panel Covered With 5Mm Thick Prelaminated Pvc Sheet (Density =550 Kg/M³), Fixed With Solvent Cement, Edges Grooved And Sealed. Skirting And Exposed Sides Clad With Same Top Material. Work To Be Executed As Per Manufacturer’S Guidelines Ensuring True Level, Finish, Strength, And Aesthetics As Directed., Providing, Supplying & Installation Of Solid Pvc Filing Cabinet Carcasses: Supply And Fix Filing Cabinet Carcasses Made From Dimensionally Stable 18Mm ±0.7Mm Thick Solid Pvc Panels (Density =600 Kg/M³) Of Iso 9001 Certified Brand Make Approved By Nau Authority Assemble All Panels (Top, Sides, Bottom, Shelving, Backing) Using Anti-Corrosive Self-Drilling Screws And Solvent Adhesive As Per Manufacturer. Vertical Panels Spaced Max 700Mm For Load And Stability. Provide Steel Reinforcement With 5Mm Thick Heat-Molded “C” Channel Where Required. Double Front Edge Of Top And Shelving With 50Mm X 18Mm Solid Board Strip. All Open Edges Lipped With 18Mm X 1Mm Edge Banding Tape. Skirting And Exposed Sides Clad With Shutter/Door Lamination Material. Execute Work As Per Manufacturer’S Guidelines Ensuring True Level, Finish, Strength, And Aesthetics As Directed., Providing, Supplying & Installation Of Filing Cabinet Carcasses Using Mr 303 Grade 18Mm Plywood: Supply And Fix Filing Cabinet Carcasses Made From Dimensionally Stable 18Mm ±0.7Mm Thick Mr 303 Grade Plywood Of Iso 9001 Certified Brand Make Approved By Nau Authority Assemble All Panels (Top, Sides, Bottom, Shelving, Backing) Using Anti-Corrosive Self-Drilling Screws As Per Manufacturer. Vertical Panels Spaced Max 700Mm For Load And Stability. Double Front Edge Of Top And Shelving With 50Mm X 18Mm Solid Board Strip. All Open Edges Lipped With 18Mm X 1Mm Edge Banding Tape. Skirting And Exposed Sides Clad With Shutter/Door Lamination Material. Internal Side Of Cabinate Carcases Clad With 0.8Mm Thick Liner Laminate. Execute Work As Per Manufacturer’S Guidelines Ensuring True Level, Finish, Strength, And Aesthetics As Directed., Providing, Supplying & Installation Of Filing Cabinet Carcasses Using Cement Bonded Particle Board: Supply And Fix Filing Cabinet Carcasses Using 20Mm Thick Cement Compressed Particle Board (Make Approved By Nau Authority) For Top, Sides, Bottom, And Shelving, And 12Mm Thick Board For Backing. Assemble With Appropriate Screws And Adhesive Ensuring True Level And Right Angles. Provide Skirting At Front As Required. Front Edges Covered With 5Mm Thick × 20Mm Teak Batten Or 2Mm Thick × 20Mm Pvc Edge Banding Tape. Vertical Panels To Rest On Floor For Load Bearing. All Panels Clad With Approved Liner Grade Laminate; Exposed Sides Covered With Matching 1Mm Thick Laminate Using Quality Adhesive. Execute Work With Proper Finish And Aesthetics As Directed., Supply & Installation Of Filing Cabinet Carcasses Using Cement Bonded Prelaminated Particle Board: Provide And Fix Filing Cabinet Carcasses Using 18Mm And 8Mm Thick Cement Bonded Prelaminated Particle Board (Make Approved By Nau Authority). Assemble All Panels With Approved Knock-Down Hardware (Make Approved By Nau Authority), Anti-Corrosive Screws, And Adhesive, Ensuring True Line And Right Angles. Backing Panel To Be 8Mm Thick. Provide Required Skirting At Front. Cover All Edges With 5Mm X 20Mm Teak Batten Or 2Mm Thick Pvc Edge Banding Tape. Vertical Panels Must Extend To Floor For Load Bearing. Complete Work With Proper Finish And Aesthetics As Directed., Supply & Fix Conference Table (Various Shapes) With Moisture-Resistant Ply: Provide And Fix Conference Tables (Straight, U, C, Oval) Using 18Mm Thick Moisture-Resistant Ply (Isi Marked, Nau Approved Make) For All Panels (Vertical, Horizontal, Front), Height 760–830Mm, Top Depth 600–680Mm. Assemble With Approved Screws And Marine-Grade Adhesive. Both Sides Laminated With 1Mm Thick Laminate (Iso 9001 Certified, Nau Approved Make). Edges Thickened As Per Design Using Mr Grade Ply; Vertical Panels Doubled To 36Mm. Finish Open Edges With 2Mm Pvc Tape Or Teak Moldings. Include Cable Management (Ebco Or Equivalent) As Required. Complete With Quality Finish And Aesthetics As Directed., Supply & Fixing Of Conference Table (Various Shapes) Using Solid Pvc Ply: Provide And Fix Conference Tables (Straight, U, C, Oval) Made From 18Mm Thick Solid Pvc/Wpc Panels (Density =600 Kg/M³) With Outer Layer 0.8–1.0Mm Thick Pvc Laminate (Density =1400 Kg/M³), From Iso 9001 Certified Brands (Make Approved By Nau Authority). Vertical Panels To Be Doubled (18Mm X 18Mm). Assemble With Approved Screws And Adhesive. All Exposed Surfaces Covered With 1.2Mm Thick Pvc Decorative Laminate Or 5Mm Solid Pvc Prelaminated Panels. Edges Thickened As Per Design Using 75/100Mm Wide Solid Pvc Panels; All Open Edges Finished With 2Mm Pvc Edge Tape. Provide Cable Management Under Top And Cable Manager (Make Approved By Nau Authority) As Required. Complete With True Finish And Aesthetics As Directed., Supply & Fixing Of Office Table Using Moisture-Resistant Ply: Provide And Fix Office Tables (Height 760–830Mm, Top Depth 600–900Mm) Made From 18Mm Thick Moisture-Resistant Ply (Isi Marked Make Approved By Nau Authority) For All Vertical, Horizontal, Shutter, Drawer Fascia, And Front Panels. Assemble With Approved Screws And Marine-Grade Adhesive (Make Approved By Nau Authority). Exposed Surfaces Covered With 1Mm Thick Laminate (Make Approved By Nau Authority), Inner Sides With 0.8Mm White/Ivory Liner Laminate. Edges Thickened As Needed Using 75/100Mm Wide Mr Grade Ply; Open Edges Finished With 2Mm Pvc Edge Tape Or Teak Moldings. Provide Isi-Marked Locking Devices (Make Approved By Nau Authority) With Duplicate Keys. Glass Tops (10Mm Thick) With Polished Rounded Edges To Be Paid Separately. Complete Work With True Finish And Aesthetics As Directed., Supply & Fixing Of Office Table Using Solid Pvc Ply: Provide And Fix Office Tables (Height 760–830Mm, Top Depth 600–900Mm) Made From 18Mm Thick Solid Pvc/Wpc Panels (Min. Density 600 Kg/M³) By Iso 9001 Certified Brands Make Approved By Nau Authority. Panels Include Vertical, Horizontal, Shutter, Drawer Fascia, And Front. Assemble With Approved Screws And Adhesive Per Manufacturer’S Guidelines. Exposed Surfaces To Be Covered With 1.2Mm Thick Pvc Decorative Laminate (Min. Density 1400 Kg/M³) Or 5Mm Solid Pvc Prelaminated Panel. Edges Thickened With 75/100Mm Solid Pvc Panels As Required. Open Edges Finished With 2Mm Pvc Edge Tape. Provide Isi-Marked Locking Devices (Make Approved By Nau Authority) With Duplicate Keys. Optional 10Mm Thick Glass Top With Polished Rounded Edges Paid Separately. Complete Work With True Finish And Aesthetics As Directed., Supply & Fixing Of 12Mm Thick Glass Top: Provide And Fix 12Mm Thick Glass Top Of “Modiguard” / “Saint Gobain” Approved By Nau Authority. All Edges To Be Rounded/Sloped As Directed. Glass To Be Supported On Furniture Using Glass-Holding Vacuum Plugs Or Stainless Steel Studs (100Mm/150Mm/200Mm)., Supply & Installation Of Computer Table With Cubicle Using Prelaminated Cement Bonded Particle Board: Provide And Fix Computer Room Cubicles Using 18Mm And 8Mm Thick Prelaminated Cement Bonded Particle Board Make Approved By Nau Authority). Side Panels: 1200Mm (H) X 600Mm (W); Table Top Depth 530Mm, Height 765Mm. Table Supported By Bottom Panel With 250Mm Gap For Cpu Storage, Plus Salving Panel For Cpu Unit. Assemble All Panels Using Knock-Down Hardware (Make Approved By Nau Authority) With Screws And Adhesive. Provide Adjustable Cpu Stand If Required. Edges Finished With 2Mm Pvc Edge Banding. Include Two Quality Cable Managers And One Powder-Coated Sliding Keyboard Tray With Mouse Holder (Make Approved By Nau Authority). Complete Work With Proper Finish, Alignment, And True Level As Directed., Supply & Fixing Of 18Mm Thick Solid Pvc Shelving: Provide And Fix 18Mm (+/-0.15Mm) Thick Solid Pvc Shelving (Density 600 Kg/M³) By Iso 9001-2015 Certified Brands Make Approved By Nau Authority. Shelves To Be Supported On All Three Sides With 50Mm Wide 18Mm Thick Pvc Supports Fixed With Appropriate Screws And Pvc Reinforcement. Shelving Panels Fixed With Screws And Solvent Cement Adhesive. Front Edges Reinforced With 18Mm X 50Mm Pvc Strips And Finished With 2Mm Thick Edge Banding Tape As Per Manufacturer’S Guidelines. Work To Be Done In True Line And Level, Maintaining Aesthetic Standards As Directed., Supply & Fixing Of Cement Bonded Particle Board Shelving: Provide And Fix 18/20 Mm Thick Cement Bonded Particle Board Shelving With Open Edges Covered By 20 Mm X 5 Mm Wood Battens. Both Sides Of Shelving To Be Finished With Two Coats Of Distemper Paint. Shelves Supported Using “C” And “L” Shape Cappings. Work To Be Executed In True Line And Level, Maintaining Aesthetics As Directed By Officer-In-Charge., Supply & Fixing Of Mr 303 Grade 18Mm Plywood Shelving: Provide And Fix 18 Mm Thick Mr 303 Grade Plywood Shelving With Open Edges Covered By 20 Mm X 5 Mm Wood Battens. Both Sides Of Shelving To Be Finished With Both Side 0.8 Mm Liner Laminate. Shelves Supported Using “C” And “L” Shape Cappings. Work To Be Executed In True Line And Level, Maintaining Aesthetics As Directed By Officer-In-Charge., Supply & Fixing Of Drawers For Cabinets, Cupboards, Office Tables: Provide And Fix Drawers With Four Side Panels Of 18/20 Mm Thick Solid Pvc/Wpc (Make Approved By Nau Authority) Having Minimum Density 500 Kg/M³ And Compressive Strength 15 Mpa. Side Panel Heights: 75/150/200/300 Mm. Bottom Panel: 10 Mm Thick Solid Pvc/Wpc Or 4 Mm Thick Approved Aluminum Composite Panel. Panels To Be Securely Assembled With Approved Screws And Adhesive Per Manufacturer’S Guidelines. Drawers To Be Fitted With Two Telescopic Runners (Ebco/Hattich Nau Approved). Work To Be Finished True To Line And Level As Directed By Officer-In-Charge., Supply & Fixing Of 50 Mm Dia. Rigid Pvc Drainage Pipeline: Provide And Fix 50 Mm Dia. Rigid Pvc Drainage Pipeline With All Necessary Isi-Marked Fittings And Fasteners (Elbows, Tees, Couplers, Traps, Sealants) From Approved Brands (Make Approved By Nau Authority, Nau Approved). Pipes To Have Minimum 6 Kg/Cm² Pressure Rating With Leak-Proof Joints. Complete Work As Directed By Officer-In-Charge., Supply & Fixing Of 100 Mm Dia. Rigid Pvc Drainage Pipeline: Provide And Fix 100 Mm Dia. Rigid Pvc Drainage Pipeline With Isi-Marked Pipes And Fittings (Elbows, Tees, Couplers, Traps, Sealants) From Approved Brands (Make Approved By Nau Authority, Nau Approved). Pipes To Have Minimum 6 Kg/Cm² Pressure Rating And Leak-Proof Joints. Complete As Directed By Officer-In-Charge., Supply & Fixing Of 610 X 535 Mm Laboratory Ceramic Sink: Provide, Supply, And Fix 610 X 535 Mm Laboratory Ceramic Sink (Standard Brand, Any Color) On Cement Or Pvc Board Platform With All Necessary Fittings, Fixtures, And Adhesive/Mortar (Pillar Cock Excluded). Complete As Directed By Engineer-In-Charge., Providing, Supplying & Fixing Office Table With Granite Top (Mr Ply): Supply And Fix Office Table (Height 760–830 Mm, Depth 600–900 Mm) Made From 18 Mm Thick Isi-Marked Moisture-Resistant Ply (Make Approved By Nau Authority) For All Structural Panels. All Exposed Surfaces To Be Finished With 1 Mm Thick Sf-Grade Laminate; Internal Surfaces With 0.8 Mm Liner-Grade Laminate (Make Approved By Nau Authority, Iso 9001 Certified). Panel Edges To Be Sealed With 2 Mm Pvc Edge Tape Or Polished Teakwood Molding. Edges To Be Thickened With 75–100 Mm Mr-Grade Ply Where Required. 19 Mm Thick Granite Top Fixed Over Ply Using Bond Tite Or Equivalent Adhesive, With Moulded Edges. Fitted With Isi-Marked Locking Device ((Make Approved By Nau Authority). Drawers Paid Separately.Work To Be Completed In Line And Level With An Aesthetic Finish As Per Directions Of The Officer-In-Charge., Providing, Supplying & Fixing Solid Wpc Door Frame (90X45 Mm): Supply And Fix 90 Mm X 45 Mm Solid Wood Plastic Composite (Wpc) Door Frame Of Minimum 780 Kg/M³ Density, Manufactured By Iso 9001:2015 Certified Company (Make Approved By Nau Authority). Frame Sections To Be Cut To Size And Joined Using Recommended Screws And Adhesive. Fixing To Be Done With Hooks And Self_Expanding Screws As Per Manufacturers Guidelines. Gaps Between Frame And Wall To Be Filled With Silicone Or Cement_Based Filler (Make Approved By Nau Authority). Work To Be Completed In True Line And Level With Good Finish As Directed By The Engineer_In_Charge., Providing, Supplying & Fixing Solid Wpc Door Frame (100X50 Mm): Supply And Fix 100 Mm X 50 Mm Solid Wood Plastic Composite (Wpc) Door Frame With Minimum Density Of 780 Kg/M³, Manufactured By Iso 9001:2015 Certified Company ((Make Approved By Nau Authority). Frame Sections To Be Cut And Joined Using Approved Screws And Adhesive As Per Manufacturers Instructions. Install Using Hooks And Self_Expanding Screws. Fill All Gaps Between Frame And Wall With Silicone Or Cement_Based Filler (Make Approved By Nau Authority). Work To Be Completed In True Line, Level, And With Neat Finish As Directed By The Engineer_In_Charge., Providing, Supplying & Fixing Solid Wpc Double Rabbet Door Frame (120X50 Mm): Supply And Fix 120 Mm X 50 Mm Solid Wood Plastic Composite (Wpc) Double Rabbet Door Frame With Minimum Density Of 780 Kg/M³, Manufactured By Iso 9001:2015 Certified Company (Make Approved By Nau Authority). Frame Sections Shall Be Cut, Joined, And Fixed Using Approved Screws And Adhesive As Per Manufacturer’S Specifications. Install With Hooks And Self_Expanding Screws. Gaps Between Frame And Wall To Be Filled With Silicone Or Cement_Based Filler (Make Approved By Nau Authority). Work To Be Completed In True Line, Level, And With A Clean Aesthetic Finish As Directed By The Engineer_In_Charge., Providing, Supplying & Fixing Pvc Door Frame (Chokhat): Supply And Install Pvc Chokhat Made From 53×60 Mm Or 42×50 Mm Extruded Pvc Sections (Make Approved By Nau Authority), Reinforced With Seasoned Wood. Corners To Be Joined Using 200×85×25 Mm High_Density Polymeric Blocks And Fixed With Screws. For Hinges, Handle, Or Knob, Provide 15×300 Mm Solid Polymer Reinforcement. All Joints To Be Sealed With “Thanga Bond” Adhesive And Dow Corning Silicone. Work To Be Completed In True Line, Level, And With A Neat Aesthetic Finish As Directed By The Engineer_In_Charge., Providing, Supplying & Installation Of 30 Mm Thick Pvc Laminated Door: Supply And Install 30 Mm Thick Pvc Laminated Door Using Heavy_Grade Profiles (Non_Economy) From Make Approved By Nau Authority. Door Frame Sections Shall Be 24×44 / 24×60 / 24×85 / 24×110 Mm, With 20 Mm Thick Multi_Chambered Hollow Pvc Infill Panel (1_Piece, Pre_Laminated) And 1.8 Mm Minimum Wall Thickness. Use 200×85×25 Mm High_Density Polymer Corners For Frame Assembly. Reinforce Hinge And Hardware Zones With 15×300 Mm Solid Polymer Insert. Fix 3 Nos. Stainless Steel Hinges (75×19×19 Mm), 2 Nos. 125×15 Mm Ss Handles, And 2 Nos. 200×10 Mm Ss Aldrops With Zinc_Coated Screws (16×6 Mm). Use Adhesive For Panel And Channel Joints. Install All Hardware Over Reinforcement. Ensure Neat Alignment And Aesthetic Finish As Directed By The Engineer_In_Charge., Providing And Fixing Solid Core Flush Door With Both Side Laminate (Nau Approved Brand): Providing And Fixing 30 Mm Thick Solid Core Flush Door Made From Seasoned Timber, Hot_Pressed With Phenol Formaldehyde Resin Under Cross_Bonding Process. Door Should Be Termite Resistant, Moisture_Proof, Dimensionally Stable, With Minimum Density Of 600 Kg/M³, Moisture Content 8To10percentage, Screw Holding Strength ≫225 Kg, And Nail Holding Strength ≫100 Kg. Both Sides To Be Finished With 1 Mm Thick Decorative Laminate (Make Approved By Nau Authority) Using Marine_Grade Adhesive. Provision For Vision Panel/Louver Cutouts If Required. Hardware To Include: • 2 Nos. Ss Aldrops (8×200 Mm) • 1 No. Ss Door Stay • 4 Nos. Ss Hinges (150×25×25×3 Mm) • 1 No. Ss Handle (200×5×3 Mm) All Fittings Should Be Fixed Securely And Neatly. Work To Be Completed In True Line, Level, And As Per Engineer_In_Charge’S Direction., Providing, Supplying & Fixing 30 Mm Thick High_Strength Pvc Door Shutter With Iron Reinforcement (Nau Approved): Providing And Fixing 30 Mm Thick High_Strength Prelaminated Solid Pvc Door Shutter With Internal Ms Reinforcement. The Shutter Shall Consist Of 5 Mm Thick Prelaminated Solid Pvc Panels On Both Sides, With A Core Of 15 Mm Thick Solid Pvc (Minimum Density 600 Kg/M³), Manufactured By Iso 9001:2015 Certified Brand ((Make Approved By Nau Authority). Top, Bottom, And Lock Rails Shall Be Reinforced With 19 Mm × 19 Mm, 19_Gauge Ms Square Pipes Coated With A Primer. Core Construction Includes 20 Mm Thick Multi_Chambered Hollow Pvc Profiles (1 Mm Wall Thickness) Reinforced With Solid Pvc Battens, Bonded Using Cyanoacrylate/Solvent Cement Adhesive. All Four Edges To Be Sealed With 15 Mm Thick × 20 Mm Wide Pvc Battens Using Approved Solvent Adhesive. Lock Rail Reinforced With 20 Mm Pvc Insert. Lipped Edge To Be Finished With Matching Pvc Ink. Fittings Include: • 3 Nos. Ss Hinges (100 × 25 × 25 × 3 Mm) • 2 Nos. Ss Handles (125 × 15 Mm) • 2 Nos. Ss Aldrops (200 × 10 Mm) All Accessories To Be Of Approved Quality And Securely Fixed. Entire Work To Be Completed In True Line And Level, Ensuring Durability And Aesthetic Finish As Directed By The Engineer_In_Charge., Providing & Fixing 35 Mm Thick Solid Core Flush Door With Both Side Laminate (Nau Approved): Providing And Fixing 35 Mm Thick Solid Core Flush Door Made From Seasoned Timber, Hot_Pressed With Phenol Formaldehyde Resin Under Cross_Bonding. Door Should Be Dimensionally Stable, Termite_ And Moisture_Resistant, With A Minimum Density Of 600 Kg/M³ And Moisture Content Between 8–10Percentage. Screw And Nail Holding Strength Shall Be =225 Kg And =100 Kg Respectively. Both Faces To Be Laminated With 1 Mm Thick Decorative Laminate (Make Approved By Nau Authority) Using Marine_Grade Adhesive. Openings For Vision Panels Or Louvers To Be Provided As Required. Door To Be Installed With: • 4 Nos. Stainless Steel Hinges (150 × 25 × 25 × 3 Mm) • 2 Nos. Ss Aldrops (8 Mm × 200 Mm) • 1 No. Ss Door Stay • 1 No. Ss Handle (200 × 5 × 3 Mm) All Accessories To Be Of Approved Quality. Work To Be Completed In True Line And Level With Smooth Finish, As Directed By The Engineer_In_Charge., Providing, Supplying & Fixing 30 Mm Thick Three_Layer Solid Pvc Door (Nau Approved): Providing And Fixing 30 Mm Thick Co_Extruded Three_Layer Rigid Pvc Foam Door, Made From Solid Pvc Board (Minimum Density 600 Kg/M³) With Outer Layers (0.8–1.0 Mm) Of High_Density Pvc (=1400 Kg/M³), Manufactured By Iso 9001:2015 Certified Brand (Make Approved By Nau Authority). All Four Edges Shall Be Sealed With 2 Mm Thick, 30 Mm Wide Pvc Edge Band Using Approved Solvent Adhesive. Door To Be Installed With: • 3 Nos. Stainless Steel Hinges (100 × 25 × 25 × 3 Mm) • 2 Nos. Stainless Steel Handles (125 × 15 Mm) • 2 Nos. Ss Aldrops (200 × 10 Mm) All Hardware To Be Of Approved Quality. Installation To Be Completed In True Line, Level, And With A Neat Finish As Directed By The Engineer_In_Charge., Providing & Fixing Fully Glazed Color Anodized/Powder Coated Aluminum 2_Track Sliding Window: Supply And Install 2_Track Sliding Window Made From Approved Color Anodized/Powder Coated Aluminum Sections (Make Approved By Nau Authority). Frames To Include Bottom (61.85X31.75X1.5 Mm), Top/Sides (61.85X31.75X1.5 Mm), Sliding Shutter Top (40X18x1.55 Mm), Bottom (52X18x1.56 Mm), Handles/Sides (40X18x1.55 Mm), And Interlock (40X27x1.45 Mm) Profiles As Per Manufacturer Specs. Glazing With 5 Mm Thick Plain Or Tinted Glass (Make Approved By Nau Authority). Complete With Fixtures, Fasteners, Locking System, Transparent Rubber Gaskets, Extruded Weather Strips, And Anti_Rattling Vibration Control At Top And Bottom. Installation As Per Drawings And Direction Of Engineer_In_Charge And Architect., Providing & Fixing Fully Glazed Color Anodized/Powder Coated Aluminum 3_Track Sliding Window: Supply And Install 3_Track Sliding Window Using Approved Color Anodized/Powder Coated Aluminum Sections (Make Approved By Nau Authority) As Per Is 1949. Frame Sections Include Bottom (92X31.75X1.5 Mm), Top/Sides (92X31.75X1.5 Mm), Sliding Shutter Top (40X18x1.55 Mm), Bottom (52X18x1.56 Mm), Handles/Sides (40X18x1.55 Mm), And Interlock (40X27x1.45 Mm). Glazed With 5 Mm Thick Plain Or Tinted Glass (Make Approved By Nau Authority). Complete With Fixtures, Fasteners, Locking System, Wool Felt, Virgin Transparent Rubber Gaskets, Extruded Weather Strips, And Anti_Rattle Vibration Control Pieces At Top And Bottom. Work As Per Manufacturer Specs, Drawings, And Engineer/Architect Instructions., Providing & Fixing Color Anodized Aluminum Sliding Window With Mosquito Net: Supply And Fix Color Anodized Aluminum Sliding Window Sections (Make Approved By Nau Authority). Two_Track Bottom Section: 31.75X61.85Mm, 1.20Mm Thick, Approx. 0.700 Kg/Rmt; Top/Vertical Two_Track: Same Size, 1.30Mm Thick, Approx. 0.655 Kg/Rmt. Shutter Frame Sections And Interlocks: Min. 1.20Mm Thick With Specified Sizes And Weights.Sliding Shutters Fitted With Isi Brand Runner Bearings And Locking System. Mosquito Net Of Ss 304 Grade Wire Mesh (20X30 Gauge, 8Percentage Nickel, Approx. 0.685 Kg/Smt) With Pvc Buffers (10X10mm) On All Edges. Gaps Sealed With Waterproof Silicon. Installed Using Stainless Steel Screws And Wall Plugs. Finished True To Line And Level As Directed., Providing & Fixing Hydraulic Floor Springs (Capacity Up To 150 Kg): Supply And Fix Double_Action Hydraulic Floor Springs Of Approved Brand (Make Approved By Nau Authority, Is:6315 Compliant) For Aluminum, Glass, Or Wooden Flush Doors. Capacity Up To 150 Kg. Includes Floor Cutting, Embedding, Cover Plates, Chipping, Finishing, And Repairs As Directed., Providing & Fixing Round/Handle Lock (S.S. Finish): Supply And Fix Make Approved By Nau Authority Six_Lever Cylindrical/Round Head Lock With All Necessary Hardware, Complete As Directed By Engineer_In_Charge., Providing, Fixing & Supplying Fan Hook: Supply And Fix 16 Mm Dia. Ms Fan Hook Bent With Hooked Ends, Embedded In Rcc Slab During Casting, Including Painting Of Exposed Portion., Providing & Fixing Isi Hydraulic Door Closer: Supply And Fix Isi_Approved Hydraulic Door Closer Of Approved Make, Installed In True Line And Level On Doors/Walls, Complete As Directed., Providing & Fixing Hydraulic Floor Springs (Up To 90 Kg): Supply And Install Double_Action Hydraulic Floor Springs Of Approved Is:6315 Brand (Make Approved By Nau Authority) For Aluminum, Glass, Or Wooden Doors With Capacity Up To 90 Kg. Includes Floor Cutting, Embedding, Cover Plates, Finishing, And Repairs As Directed., Providing & Fixing Hydraulic Floor Springs (Up To 120 Kg): Supply And Install Double_Action Hydraulic Floor Springs (Capacity Up To 120 Kg) Of Approved Is:6315 Brands (Make Approved By Nau Authority) For Aluminum, Glass, Or Wooden Doors. Includes Floor Cutting, Embedding, Cover Plates, Finishing, And Repairs As Directed., Providing & Supplying Heavy_Duty Plastic Chair Without Arm (Nilkamal/Cello/Supreme): Supply Of Robust Molded Plastic Chair Without Arm, Supporting Up To 110 Kg. Approximate Size: W47 Cm X D51 Cm X H89 Cm; Weight Approx. 2 Kg. Chair To Include Minimum 1_Year Manufacturer Warranty From Supply Date., Providing & Supplying Heavy_Duty Plastic Chair With Arm (Nilkamal/Cello/Supreme): Supply Of Molded Plastic Chair With Arm, Supporting Up To 125 Kg. Approx. Size: W56 Cm X D61 Cm X H78 Cm; Weight Approx. 2.2 Kg. Includes Minimum 1_Year Manufacturer Warranty From Supply Date., Providing & Supplying Plastic Chair With Arm And Cushion (Nilkamal/Cello/Supreme): Heavy_Duty Molded Plastic Chair With Arm, Fabric Cushions On Seat And Back, Supporting Up To 125 Kg. Approx. Size: W56 Cm X D56 Cm X H81 Cm; Weight Approx. 3.0 Kg. Includes Minimum 1_Year Manufacturer Warranty From Supply Date., Providing, Supplying & Placing Mid_Back Chair With Polypropylene: Seat Made Of 12Mm Hot_Pressed Plywood; Back Of Injection_Molded Glass_Filled Polypropylene, Upholstered. Seat Size: 47 X 51.5 Cm; Back Size: 45 X 65.3 Cm. High Resilience (Hr) Polyurethane Foam (Density 55±2 Kg/M³, Hardness 16±2 Kgf As Per Is:7888). Armrests Adjustable Up/Down By 8.5 Cm With Tpe Top Layer. Height_Adjustable Lumbar Support (8±0.5 Cm Adjustment). Front Pivot Synchro Mechanism With 360° Swivel, Single_Point Control, Tilt Tension Adjustment, 4_Position Lock With Anti_Shock, Seat/Back Tilt Ratio 1:2. Pneumatic Height Adjustment Stroke 10 Cm. Black Glass_Filled Nylon Pedestal With 5 Twin_Wheel Castors; Pedestal Diameter Approx. 66 Cm (76 Cm With Castors). Overall Dimensions: W 76.1 Cm, D 76.1 Cm, H 98–108 Cm, Seat Height 45.8–55.8 Cm., Providing, Supplying, And Placing Mid_Back Mesh Chair: Seat: 15Mm Hot_Pressed Plywood Upholstered With Fabric And Molded Pu Foam (Size 51.8 X 49.7 Cm). Back: Injection_Molded Glass_Filled Polypropylene With Fabric Upholstery And Adjustable Lumbar Support (5–10 Cm Adjustment); Back Size 47.9 X 66.9 Cm. Hr Pu Foam Seat Density 45±2 Kg/M³, Hardness 14±2 Kgf (Is:7888). Adjustable Armrests (Height 6–10 Cm) With Swivel And Fore_Aft Movement, Molded Pu Top. Active Bio_Synchro Mechanism: 360° Swivel, Front_Pivot Tilt With Foot Support, Continuous Lumbar Support, Tilt Tension Adjustable, 5_Position Tilt Limiter, Seat/Back Tilt Ratio 1:2; Mechanism Housing Of Hpdc Aluminum With Black Powder Coating (40–60 Micron). Pneumatic Height Adjustment Stroke 10±0.3 Cm. Pedestal: Injection_Molded Black 30Percentage Glass_Filled Nylon With 5 Twin_Wheel Castors (Wheel Diameter 6±0.1 Cm). Overall Dimensions: W 76 Cm, D 76 Cm, H 95.5–105.5 Cm, Seat Height 43.5–54 Cm., Providing, Supplying & Placing High_Back Chair With Polypropylene: Seat Made Of 12Mm Hot_Pressed Plywood; Back Of Injection_Molded Glass_Filled Polypropylene, Upholstered. Seat Size: 47 X 51.5 Cm; Back Size: 45 X 65.3 Cm. High Resilience (Hr) Polyurethane Foam (Density 55±2 Kg/M³, Hardness 16±2 Kgf As Per Is:7888). Armrests Adjustable Up/Down By 8.5 Cm With Tpe Top Layer. Height_Adjustable Lumbar Support (8±0.5 Cm Adjustment). Front Pivot Synchro Mechanism With 360° Swivel, Single_Point Control, Tilt Tension Adjustment, 4_Position Lock With Anti_Shock, Seat/Back Tilt Ratio 1:2. Pneumatic Height Adjustment Stroke 10 Cm. Black Glass_Filled Nylon Pedestal With 5 Twin_Wheel Castors; Pedestal Diameter Approx. 66 Cm (76 Cm With Castors). Overall Dimensions: W 76.1 Cm, D 76.1 Cm, H 140 Cm – 150Cm, Seat Height 100 Cm – 106Cm., Providing, Supplying, And Placing High_Back Mesh Chair: Seat: 15Mm Hot_Pressed Plywood Upholstered With Fabric And Molded Pu Foam (Size 51.8 X 49.7 Cm). Back: Injection_Molded Glass_Filled Polypropylene With Fabric Upholstery And Adjustable Lumbar Support (5–10 Cm Adjustment); Back Size 47.9 X 66.9 Cm. Hr Pu Foam Seat Density 45±2 Kg/M³, Hardness 14±2 Kgf (Is:7888). Adjustable Armrests (Height 6–10 Cm) With Swivel And Fore_Aft Movement, Molded Pu Top. Active Bio_Synchro Mechanism: 360° Swivel, Front_Pivot Tilt With Foot Support, Continuous Lumbar Support, Tilt Tension Adjustable, 5_Position Tilt Limiter, Seat/Back Tilt Ratio 1:2; Mechanism Housing Of Hpdc Aluminum With Black Powder Coating (40–60 Micron). Pneumatic Height Adjustment Stroke 10±0.3 Cm. Pedestal: Injection_Molded Black 30Percentage Glass_Filled Nylon With 5 Twin_Wheel Castors (Wheel Diameter 6±0.1 Cm). Overall Dimensions: W 76.1 Cm, D 76.1 Cm, H 140 Cm – 150Cm, Seat Height 100 Cm – 106Cm., Providing And Fixing Gi Steel Work: Supply, Fabrication, And Erection Of Welded Prefabricated Gi Steel Structures For Windows And Grills Using Structural Steel Tubes, Plates, Flats, Square Bars, And Rods. Includes Cutting, Welding, Bolting With Bolts/Nuts/Washers, Surface Preparation, One Coat Zinc Phosphate Primer Before Erection, And Two Coats Synthetic Enamel Paint After Erection. Complete As Per Drawings And Specifications., Providing And Fixing Ms Steel Work: Supply, Fabrication, And Erection Of Welded Prefabricated Ms Steel Structures For Windows And Grills Using Structural Steel Tubes, Plates, Flats, Square Bars, And Rods. Includes Cutting, Welding, Bolting With Bolts/Nuts/Washers, Surface Preparation, One Coat Zinc Phosphate Primer Before Erection, And Two Coats Synthetic Enamel Paint After Erection. Complete As Per Drawings And Specifications.Top Of Formbottom Of Form, Providing, Supplying & Installing Perforated Cutlery Kitchen Basket (370X485x100 Mm): Supply And Fix Perforated Kitchen Basket Made Of 201 Grade Nickel_Chromium Plated Steel, Model Make Approved By Nau Authority. Basket Frame: 5 Mm Round S.S. 202 Nickel_Chromium Plated; Bottom: Perforated S.S. 201 Sheet. Installed In Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Perforated Cutlery Kitchen Basket (420X485x100 Mm): Supply And Fix Perforated Kitchen Basket Of 201 Grade Nickel_Chromium Plated Steel, Make Approved By Nau Authority Basket Frame: 5 Mm Round S.S. 202 Nickel_Chromium Plated; Bottom: Perforated S.S. 201 Sheet. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Perforated Cutlery Kitchen Basket (470X520x100 Mm): Supply And Fix Perforated Kitchen Basket Of 201 Grade Nickel_Chromium Plated Steel, Make Approved By Nau Authority. Basket Frame: 5 Mm Round S.S. 202 Nickel_Chromium Plated; Bottom: Perforated S.S. 201 Sheet. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Perforated Cutlery Kitchen Basket (520X520x100 Mm): Supply And Fix Perforated Kitchen Basket Of 201 Grade Nickel_Chrome Plated Steel, Make Approved By Nau Authority Basket Frame: 5 Mm Round S.S. 202 Nickel_Chrome Plated; Bottom: Perforated S.S. 201 Sheet. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Thali/Plate Kitchen Basket (370X485x200 Mm): Supply And Fix Thali/Plate Basket Of 202 Grade Nickel_Chrome Plated Steel, Make Approved By Nau Authority. Basket Frame: 5 Mm Round S.S. 202 Nickel_Chrome Plated; Bottom Structure: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Thali/Plate Kitchen Basket (420X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Basket Frame: 5 Mm Round S.S. 202 Nickel_Chrome Plated; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Thali/Plate Kitchen Basket (470X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Basket Frame: 5 Mm Round S.S. 202 Nickel_Chrome Plated; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Thali/Plate Kitchen Basket (520X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202 Nickel_Chrome Plated; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (370X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work Completed In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (420X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (470X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (520X485x200 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work Executed In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (370X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work Executed In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (420X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (470X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (520X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (370X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (420X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (470X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Plain Kitchen Basket (520X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Work To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Cup Saucer Basket (370X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Cup Saucer Basket (420X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Cup Saucer Basket (470X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Cup Saucer Basket (520X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Partition Kitchen Basket (370X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Partition Kitchen Basket (420X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Partition Kitchen Basket (470X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, “Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Partition Kitchen Basket (520X485x150 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, “Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level As Directed By Engineer., Providing, Supplying & Installing Partition Kitchen Basket (370X485x100 Mm): Supply And Fix 202_Grade Nickel_Chrome Plated Steel Basket, Make Approved By Nau Authority. Frame: 5 Mm Round S.S. 202; Bottom: 2.7 Mm S.S. 201 Round Bar. Installed On Existing Stone Platform With Seasoned Teak Packing, Approved 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation In True Line And Level As Directed By Engineer., Partition Kitchen Basket (420X485x100 Mm) – Supply & Installation Providing And Fixing Partition Kitchen Basket Of Size 420X485x100 Mm Made From 202 Grade Steel With Nickel_Chrome Plating, “Make Approved By Nau Authority. Frame: 5 Mm S.S. 202 Round Steel; Bottom: 2.7 Mm S.S. 201 Round Bar. Fixing Includes Seasoned Teak Wood Packing, 510 Mm Telescopic Channel (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installed In True Line And Level, Maintaining Aesthetics As Directed By Engineer_In_Charge., Partition Kitchen Basket (470X485x100 Mm) – Supply & Installation Providing And Installing Partition Kitchen Basket Of Size 470X485x100 Mm Made From 202_Grade S.S. With Nickel Chrome Plating, Make Approved By Nau Authority. Frame: 5 Mm S.S. 202 Round Steel; Base: 2.7 Mm S.S. 201 Round Bar. Fixing With Seasoned Teak Wood Packing, 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be Done In True Line And Level, Maintaining Aesthetics As Per Engineer’S Instructions., Partition Kitchen Basket (520X485x100 Mm) – Supply & Installation Supplying And Installing Partition Kitchen Basket Of Size 520X485x100 Mm, Made From 202_Grade Stainless Steel With Nickel Chromium Plating (Make Approved By Nau Authority). Frame: 5 Mm S.S. 202 Round Bar; Base: 2.7 Mm S.S. 201 Round Bar. Mounted On Existing Stone Kitchen Platform Using Seasoned Teak Wood Packing, 510 Mm Telescopic Channels (Make Approved By Nau Authority), Nylon Plugs, And Anti_Corrosive Screws. Installation To Be In True Line And Level, Ensuring Aesthetic Finish As Directed By The Engineer., Supply & Installation Of 12–16 Mm (Id–Od) Water Supply Pipeline Supplying, Laying, And Fixing 12–16 Mm (Id–Od) Multilayer Composite Water Pipeline (Make Approved By Nau Authority) With Composite Fittings Such As Female/Male Threaded Connectors, Tees (Equal/Reducing), Elbows, Etc., Suitable For Laboratory And Solar Water Heating System. All Work To Be Completed As Per Specifications And As Directed By Engineer_In_Charge., Supply & Installation Of 16–20 Mm (Id–Od) Water Supply Pipeline Providing, Supplying, And Installing 16–20 Mm (Id–Od) Multilayer Composite Pipe (Make Approved By Nau Authority), With All Required Composite Fittings (Threaded Connectors, Tees, Elbows, Reducers, Etc.) For Laboratory And Solar Water Heating Systems. Work To Be Completed As Per Specifications And As Directed By The Engineer_In_Charge., Supply & Installation Of 20–25 Mm (Id–Od) Water Supply Pipeline Providing, Supplying, And Installing 20–25 Mm (Id–Od) Multilayer Composite Pipe (Make Approved By Nau Authority), Including All Necessary Composite Fittings (Threaded Connectors, Tees, Elbows, Reducers, Etc.) For Laboratory And Solar Water Heating Systems, As Directed By The Engineer_In_Charge., Supply & Installation Of 25–32 Mm (Id–Od) Water Supply Pipeline Providing, Supplying, And Installing 25–32 Mm (Id–Od) Multilayer Composite Pipeline (Make Approved By Nau Authority), With Required Composite Fittings (Threaded Connectors, Tees, Elbows, Reducers, Etc.) For Laboratory And Solar Water Heating Systems, As Per Directions Of The Engineer_In_Charge., Supply & Installation Of Solar Water Heating System Providing, Supplying, And Installing An Mnre_Approved, Iso 9001:2000 Certified Solar Water Heating System Of Supreme Solar/ Tata Power/ Farmson/Uratom Brand. The System Shall Be A Non_Pressurized, Direct_Injection Vacuum Tube Type With The Following Specifications: Tank: 2.5 Mm Thick Epoxy_Coated Gi Inner Tank (Tig Welded), Outer Cladding Of Pre_Painted Gi, Insulated With Cfc_Free Pu Foam. Collector Tubes: • For 300 Lpd: 30 Tubes (58 Mm Od, 48 Mm Id, 1800 Mm Length) • For 500 Lpd: 32 Tubes (58 Mm Od, 48 Mm Id, 2100 Mm Length) • Tubes Made Of Borosilicate 3.3 Glass (1.6 Mm Thick) With Graded Al_N/Al Coating, Vacuum ≪5×10?³ Pa, 0.8 Mpa Pressure Capacity. Gasket: Epdm Type, Heat Resistant Up To 125°C. Stand: Pre_Coated Gi Structure With All Necessary Mounting Fittings. Electric Backup: 2 Kw Immersion Heater. Accessories: Includes Required Nrv, Stopcock. Water Inlet/Outlet Piping Measured And Paid Separately. Installation To Be Completed In Line And Level, Maintaining Aesthetics, As Directed By Engineer_In_Charge., Supply Of 18Mm Mr Grade Plywood Providing And Supplying 18Mm Thick Solid Core, Moisture_Resistant (Mr) Grade Plywood Of Approved By Nau Authority At Any Centre Of Nau As Per Tender Including Loading, Unloading, And Transportation., Supply Of 12Mm Mr Grade Plywood Providing And Supplying 12Mm Thick Solid Core Mr Grade Plywood Of Approved By Nau Authority At Any Centre Of Nau As Per Tender Including Loading, Unloading, And Transportation., Supply Of 6Mm Mr Grade Plywood Providing And Supplying 6Mm Thick Solid Core Mr Grade Plywood Of Approved By Nau Authority At Any Centre Of Nau As Per Tender Including Loading, Unloading, And Transportation., Providing & Fixing Stainless Steel Ss Letter Board Supply And Installation Of Stainless Steel Ss Letter Board Signage, Fabricated As Per Approved Design And Specifications For Branding Or Display Purposes., Providing & Fixing Acp (Aluminum Composite Panel) Name Board Supply And Installation Of Lightweight, Durable Acp Name Board Made Of Two Aluminum Sheets Bonded To A Core, Suitable For Weather_Resistant Outdoor Signage As Per Specifications., Providing & Supplying Sofa Supply And Installation Of Sofa As Per Specified Dimensions, Made With Solid Wood, Metal, Engineered Wood, And Plywood. Upholstered In High_Density, Fire_Retardant Fabric Or Leather (Up To Rs. 500 Per Running Meter). Seating Includes Coil/Pocket Springs Or High_Density Foam For Comfort. Legs Made Of Solid Wood, Metal, Or Plastic With Matching Finish., Providing & Supplying Sofa Supply And Installation Of Sofa As Per Given Dimensions, Made From Solid Wood, Metal, Engineered Wood, And Plywood. Upholstered With High_Density, Fire_Retardant Fabric Or Leather (Rs. 500–1000 Running Meter Range, User’S Choice). Seating Includes Coil/Pocket Springs Or High_Density Foam For Comfort And Durability. Legs Made Of Solid Wood, Metal, Or Plastic With Matching Finish., Providing & Supplying Sofa Supply And Installation Of Sofa As Per Given Dimensions, Made From Indian Teakwood. Upholstered With High_Density, Fire_Retardant Fabric Or Leather (Up To Rs. 1500 Running Meter, User’S Choice). Seating Includes Coil/Pocket Springs Or High_Density Foam For Comfort And Durability. Legs Made Of Solid Wood, Metal, Or Plastic With Matching Finish.

Key Value

Document Fees
INR 5000 /-
EMD
INR 200000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail