Tender For Supply Installation Testing And Commissioning For Installation Of 2 Nos Ht Meter For New Terminal Building At Leh Airport On Full Turnkey Basis Under Deposit Work 2025 26, Leh-Ladakh

Power Development Department has published Tender For Supply Installation Testing And Commissioning For Installation Of 2 Nos Ht Meter For New Terminal Building At Leh Airport On Full Turnkey Basis Under Deposit Work 2025 26. Submission Date for this Tender is 18-08-2025. Energy Meter Tenders in Leh Ladakh. Bidders can get complete Tender details and download the document.




Tender Notice

50625470
Tender For Supply Installation Testing And Commissioning For Installation Of 2 Nos Ht Meter For New Terminal Building At Leh Airport On Full Turnkey Basis Under Deposit Work 2025 26
Tender
Indian
Ladakh
Leh
18-08-2025

Tender Details

Supply Installation Testing And Commissioning For Installation Of 2 Nos Ht Meter For New Terminal Building At Leh Airport On Full Turnkey Basis Under Deposit Work 2025 26 Same As Above- 1 HT Metering 2 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. 3 Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5 The CT ratio shall be as under:i. 150/5= 2 Sets 4 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute. 5 Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate sizePTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape 6 PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). 7 Copper Lugs preferably ring type duly crimped for termination of wires and tapes 8 Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm2 9 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS Compliant Category C with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB) 10 Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment. 11 Pedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm, duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts 12 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixing where ever required. 13 Cable termination kits suitable for 3 x 35 mm2 XLPE Cable (indoor/outdoor) 14 Earthing of HT Meter Chamber--Excavation of earth pit of dia 650mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 Mtr long as per IS 1239. GI Strip for meter chamber earthing of size 25 mm x 3 mm. GI nut & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

Key Value

Document Fees
INR 300 /-
EMD
INR 13000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail