Tourism Government Departments Closing in 0 days TDR #50621668

Tender For Transformer And Cabling Work At Ajaymeru Hotel, Ajmer.

Issued by Government Departments · ajmer, Rajasthan
Tender Value
11.08 Lakhs
Estimated cost
Bid Submission
29 Aug 2025
0 days left
EMD
23000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ajmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Transformer And Cabling Work At Ajaymeru Hotel, Ajmer.

BOQ

Name of Work: Transformer &Cabling Work at Ajaymeru hotel, Ajmer.
Sl. No. Item Description
1S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star- 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .250 KVA with Off -LTC (+5% to - 10% @ 2.5%)
2SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) ,Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-606941996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder.- 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch
3SITCofHTmeteringcubicalpanelasapprovedByDISCOMsfabricatedoutof18 SWGCRCAsheetsteel intwocompartment&MSangleof size60mmX6mm havingprovisionforFollowing:(i)ProvisionforfixingTrivector/Import-Export Meter (TobesuppliedbyDISCOMs) (ii)Provisionfor fixingofcombinedCTPT SetwithCopper strip forConnection (TobesuppliedbyDISCOMs), (iii)Test terminalBlock,(iv)6mmthickBakelitesheetonallsides,(V)3/6corex1.5/2.5 Sq.mmcopper cable for interconnections, etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
4Providing&LayingP.V.C. / XLPE insulated&P.V.C. sheathedUn-luminiumcableconfirmingtoIS:1554P-/IS:7098P-1.1KVwithH4GradeelectrolyticaluminiumconductorconfirmingtoIS8130ofpurity>99.6%,Inner/outersheathconfirmingtoIS:5831inexistingRCC/Hume/Stoneware/ PVCpipe/openduct/cabletrench/Cabletray(withcabletie) including testing etc. as requiredof following size. OEMmust have it\"s own inhouseNABL accrediated Laboratory for testingprocedureas per IS:10810. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
5185.0 Sq. mm3.5 core
6SupplyingandmakingoneendterminationwithNickelplatedheavydutybrass singlecompressiongland(asperIS12943-1990))SIBGtypeconsistingofCheck Nut,GlandBody,MetalWasher(3Nos.),OuterSealRubberRing, Compression Nut, heavydutyaluminiumlugs (asper IS8309-1993) dulycrimpedwith crimpingtool,PVCtapeasper IS8337-1976of followingsizeof PVCinsulated &PVC sheathed/ XLPE aluminiumconductor cable of 1100 volt grade as required.AllasperpreapprovedbyEngineerincharge.Foradditionaltechnical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 3.5 x 185.0 sq.mm
7Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P- 2 with H4Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 3 core 120.0 Sq.mm
8Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
911 KV End Termination Kit Indoor type3 core 120/150/185 Sq.mm
1011 KV End Termination Kit Outdoor type3 core 120/150/185 Sq.mm
11Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
12Supply&Layingfollowingsizeearthstrip inhorizontalorvertical runin surface bymeans of Earth strip DMC Insulator including riveting/ soldering/welding, Jointingshallbedonebyoverlappingandwith2set ofBrass(forCustrip)/GI(forGIStrip)nutbolt&springwasherspacedat 50cmmaking connectionetc. as required.All asper preapprovedby Engineer in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 25mm x 3mm G.I. ( Hot Dipped) Strip

AI Tender Summary

OUR REF NO 50621668
AUTHORITY Government Departments
TENDER VALUE 11.08 Lakhs
LAST DATE 29-08-2025
Authority
Authority Name Rajasthan Tourism Development Corporation Limited
Work Description Tender For Transformer And Cabling Work At Ajaymeru Hotel, Ajmer.
Basic Detail
Tender No NIT no 08 1829 dated 05-08-2025
Bidding Type Tender
Location
City ajmer
State Rajasthan
Key Dates
Publish Date 11 Aug 2025
Submission Date 29 Aug 2025
Open Date 29 Aug 2025
Finance
Tender Value 11.08 Lakhs
Tender Fee 1000
EMD 23000
Exemption Not Available
Document List
Tendernotice_1.pdf
105b0964-af22-4d18-90e0-77e7012c0967.html
BOQ_880227.xls
Ajmer.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 29, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

105b0964-af22-4d18-90e0-77e7012c0967.html

xls

BOQ_880227.xls

pdf

Ajmer.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders