| 1 | Interiors Works |
| 2 | Providing and Fixing in position Aluminium Frame work for Partitions, paneling, boxing, soffits with vertical members at not more than 600 mm centers & horizontal members not more than 600 mm centers. Complete including necessary additional supports, bracing runner etc. complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge.Size 50 x 50 x 1.62 mm |
| 3 | Size 50 x 25 x 1.62 mm |
| 4 | Providing & Fixing in position Marine plywood on existing frame work including all materials, labour etc complete. Item to be completed in all respects as per drawings & instructions from Engineer - In - Charge. i) 9mm thick Marine plywood |
| 5 | ii) 12 mm thk marine plywood |
| 6 | iii) 19 mm ply marine plywood |
| 7 | Providing & fixing in position Finishes for Partitions / Panelling. Actual executed area will be measured as two sides of same partition are likely to have different finishes. Rate of this item shall include cost of providing cross matching laminate in approved pattern etc. as per details .The finishing material shall be fixed in required divisions / panels / pattern with proper grooves etc. as per drawings & directions. Item to be completed in all respects as per drgs & instructions from EIC.i) Laminate :- Providing & Fixing Laminates of 1.5mm thickness of approved make, shade & Quality. |
| 8 | Providing & fixing in position 460 mm deep storage unit along with partitions etc with 1) sides,top,bottom shelves made out of 19 mm marine plywood for all inside surfaces 2)6 mm thk. marine ply backing panels with french polish on both sides 3) Shutters made out of 19 mm thick ply finish with material specified below from outside and one mm thick laminate for inside of shutters. 6 mm thick teakwood leaping with egde moulding of approved profile if any shall be provided in all exposed ply edge surfaces& be finished withmelamine polish.4) hardwares such as heavy duty hinges, brass body locks(Elpro make) with extra large group key of approved quality, magnetic ball catchers, handles, towerbolt etc. All exposed woodwork to be finished with 3 coats of melamine polish & all internal surface finished with 3 coats of french polish.The exposed surfaces shall be finished with 1.5 mm thk. laminate of approved shade & colour. All as per detailed drgs and instructions of EIC / Architect. Full height storage with laminate finish (FST) |
| 9 | Low height storage with Laminate finish (LST) |
| 10 | Overhead storage with Laminate finish (LST) |
| 11 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 12 | Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. |
| 13 | Executive Cabin Table Finished with Veneer in table size 2000 - 2500 mm x 1000 - 1200 mm x 750 mm) side table (size 1100 - 1300 mm x 450 mm x 700 mm) |
| 14 | Cabin Table Finished with Laminate in table size 1500 - 1800 mm x 750 - 900 mm x 750 mm) side table (size 1100 - 1300 mm x 450 mm x 700 mm) |
| 15 | Workstation L type (size 1500 x 600 x 750mm & 1250 x 600 x 750mm) |
| 16 | Square/circular corner Table - Providing & arranging in position centre tables made out of TW members 40X 75 mm with proper joinert & hardware as per drawing. The top finished with 12mm thk tinted glass with bevelled edges. Item tobe completed in all respect as per drawing & instruction from E.I.C. of given size & shape |
| 17 | Square/Circular Center table \"Providing & arranging in position center table Made out of 12 mm Toughened glass with SS Frames Size:-ø500 X 450mm\" |
| 18 | Conference table (Size 1000 X 3750 X 750MM) |
| 19 | Discussion Table (Size 1000 X 2200 X 750MM) |
| 20 | Providing and placing in requireed position Very High Back Chair of approved equiivalant make, chair of size size 49.0cm W X 48cm (H) with 75.o cm (D) including necessary approved type and colour fabric complete as per manufacturer specifications and as per instruction of Engineer in charge(Rate excluding GST). |
| 21 | Providing and placing in requireed position Mid Back Chair of approved equiivalant make, chair of size size 50.0cm W X 49.5cm (H) with 75.o cm (D) including necessary approved type and colour fabric complete as per manufacturer specifications and as per instruction of Engineer in charge. |
| 22 | Providing and placing in requireed position Mid Back Chair of approved equiivalant make, chair of size size 50.0cm W X 49.5cm (H) with 75.o cm (D) including necessary approved type and colour fabric complete as per manufacturer specifications and as per instruction of Engineer in charge(Rate excluding GST). |
| 23 | Lounge Chair- Inner frame: Built-in shaped sponge Sponge: Fully shaped sponge Fabric, base frame to be made out of metal frame stracture with duly powder coated and joint metal wood finish leg. Model : EASE |
| 24 | Providing & supplying multi seater sofas with teakwood internal frame out of size min. 70x40mm as mentioned in drawing with necessary spring /rubberised coir/32 density polyurethene foam/100% latex rubber foam of appropriate quality & thickness as shown in the drawing with melamine polish on all exposed wooden surface. 75mm thk. for seat & 50mm thk for back. 25mm polyurethene in it to give required shape. The rate to include upholstry material of approved velvet(fabric) on outer side & on the inner side white cloth of approved qulaity shade etc. The contractor shall use appropriate size of frame work instead of mentioned to achieve desired shape & comfort as shown. All as per instructions of Engineer-incharge. a) Three Seater Sofa |
| 25 | b) Single Seater Sofa |
| 26 | Providing & arranging in position dust bins out of perforated S.S Sheets (min Size 350 mm dia x 400 mm Height). Item to completed in all respect as per drg & directions. |
| 27 | Providing and fixing composite material of High Tenacity Polyester Yarn Fabric with PVC Coating, Aluminium Backing, & Fungistatic Treatment of Hunter Douglas,Serge Ferrari,MAP,Softlite Impex,Mado approved make manual Roller blinds with end brackets, components, bottom bar & fabric with manual operation and warranty of minimum 5 years and Greenguard Certificate – UL 2818 Gold Certification as per specifications. Fabric to be as per approved sample. manual system to include chain ball operation. Composition: 39% Polyester / 61% PVC with Aluminium Backing,Weight: 290 g/m2 (+/-5%) as per Fungistatic Treatment: Degree 0, Excellent (EN ISO 846-A) Fire Retardancy:B-s2,d0/EN 13501-1, CLASS A/ASTM E84., Color: as per selected color Openness factor: 3%, Reflection solar radiation: 9% TO 65%, Light transmission: 2%-4%,Solar Absorption : 22% - 88%,Solar Transmission-3% -13%,Tensile Strength (Wrap/Weft)-160/170 daN / 5cm.All complete as per approval of designer & instruction of Engineer-in-charge. |
| 28 | Supply & Installation of 3M Crystal Glass film Frosted/DUSTED/ effect with approved artwork, cut using digital plotter. Self-adhesive, bubble-free installation to be done on clean glass , by Authorized Installers only.3M Architectural Markets. 3M interior Warranty for a period of 5 years for interior application. |
| 29 | Providing & fixing Artificate like Artifical Plant, Picture Frame etc. as per shown in drawing & manufacturers specification. a) Artifical Plants |
| 30 | b) Picture Frame |
| 31 | L - shape PELMETS / Jamblining : (upto 300 mm wide)-Supplying, Providing & fixing in position of required size pelmets / jamblining made out of 19mm thick Marine ply board finished with approved finish mention below and 3 coats of French polish for inside surface as per the direction by Architect. Item to be completed in all respect as per the drawing & instruction from Architect. |
| 32 | Providing and fixing in position 12mm thk soft board panelling with approved adhesive, partition surface including fabric cover, wood beading finished with melamine polish of approved shade etc. complete as per drawings & directions by Architect. |
| 33 | Work station (Size -1250X600X750MM) |
| 34 | HVAC Works -Air Conditioners (AP-AC)-Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC |
| 35 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC |
| 36 | VRV/VRF Air conditioning -supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 37 | supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. |
| 38 | Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 39 | SITC of Hard PVC drain piping with 9mm Armaflex class \"O\" insulation and covered with fiber cloth with elbow, bends, tees, cleanouts eyc. |
| 40 | Architectural Fees |