Repair/Replacement To Fire Fighting Equipments , Fire Alarm Panels, Electrical And Diesel Engine Driven Sewage Pumps, 6 Afh Kitchen Appliances And Essential Repairs To Fire Fighting And Sewage Installations ( Domestic, Tech And 6 Afh Area); 1 Meterial and labour for removing the smoke detectors/respose indicators from below/above the false ceiling of any height, disconnect the electrical connection and cleaning the smoke detector,/respose indicators checking on bench for its proper function, refixing the detectors with reconect the electrical connection with suitable size of nut bolt & washers in fall celing boards and ensure the cable connections etc all as directed 2 Material and labour for repair/service/cleaning ,checking and callibaration of auto/manual operation fire fighting control panel with servicing of main/jockey pump starter, auto/manual operation and main Diesel pump operation with respect water pressure switch of pipe line, auto cut operation of jockey pump etc and ensure the proper functions of panel all as specified and directed. Note : (i) The cleaning materials, NO/NC contactors deemed to be included in quated rate 3 M&L for Comprehensive maintenance of50 HP diesel driven pump set for routine/preventivemaintenance checks at least twice in a month, checking up of engine and pump for trouble free functioning and attending break downs/ complaints as and when required for smooth functioning, servicing (Oil Changing of engine once in contract period) all as directedThe comprehensive maintenance includes the following works:-Note :-(a) Taking out & removing unserviceable/defective parts/spares, cleaning, servicing, oiling and greasing of necessary parts, refixing the serviceable parts in position after servicing, replacement of unserviceable parts including draining-out of existing engine oil and filling new engine oil of same grade and filters, refixing of all accessories, making functional and testing on full load complete all as directed (b) The Item rate quoted includes of fixing the serviceable parts in position and replacement of unserviceable parts with new part.The new replaced parts shall be measured and paid separately under respective items of Sch A as supply only, but the quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts small springs, O rings, screws/ gaskets/ packing/studs etc. (c) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly (d) Fresh engine oil shall be measured and paid separetely under respective item of Sch A. However the cost of filling is deemed to be included under the rates quoted by the contractor (e) All servicing of fire pump shall be done by the reputed staff of OEM. (f) attend the emergency breakedown/unserviceablity with in 24 hrs without any extracost all as directed 4 All as per item no 3 above but 14 HP diesel pump set 5 Supply only fuel filter element spin one typesuitable for diesel engine fire pumpset 50 HP all as directed 6 Supply only oil filter element Spin one AL type suitable for diesel engine fire pumpset 50 HP all as directed 7 Supply only Engine Oilfor diesel driven pumpset 50 HP pump setas per manufacturers recommendation complete as as specified and directed by Engr-in-Charge 8 Material and labour for removing the fire extinguser 9 ltrs capacity from its position, transport to workshop & back ,refilling the chemicals,water,powder,CO2 etc as per extinguser required quatity as per safety norms refixing its on same position, testing of extinguser after completion of refilling all as specified and directed 9 Supply and fix detector complying with certified EN 45 addressable type smoke detector photoelectric/optical with base with self built inteligence as per IS 11360 including taking down unserviceable detectors any type all as directed 10 Supply and fix remote response indicators including taking down unserviceable detectors all as directed 11 Supply and fix fire alarm sounder/siren electronic type horizontal two stage continuoues operation for atleast 50 minits airth sound level 65 db to 120 db measured with sound output variation of +5db of distance 500 mtr range including taking down unserviceable sounder all as directed 12 Supply and fix CP hose 15 meter legnth for fire fighting system including taking down unserviceable hose pipeall as directed 13 Supply and fix pressure switch universal type including taking out unserviceable switch all as directed 14 Material and labour for painting of steel/iron surfaces of pipes any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of Synthetic enamel fire red paint of stand post rising pipes in any postion/height including standards. braces, rails. stays etc all as specified and as directed. 15 Supply and fix sprinkler head glass bulb type standered response as per IS 15106 pendent type temperature range 68 degree including unserviceable sprinkler all as directed 16 Material and labour for fire alarm panel servicing, configaration, testing for proper function, alarm location indication, interconnection of repeter panel, dial and speach option of paneletc forof 4 loop with three cards fire alarm panel minimum 190 detectors per card, rectification of defects at any situation zone to zone vise all as directed 17 Supply, layig, connecting, testing and commissioning of 1.5 Sqmm 2 core multistanded PVC insulated copper conductor heavy duty electric cable conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe/conduit, duct or along the pole and includingthe disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, bottle type lugs etc including taking down unserviceable cable all as specified and directed. Make: Havells/Polycab/Finolex/ Paragon/Gloster/Nicco 18 Material and labour for servicing the hospital kitchen appliances motor of any capacity gears, greasing of bearings drive shaft, replacing of drive belt, testing of appliances for its proper function through authorized technician of OEM of the equipment for Dog kneeder, potato pelar, veg cutting machine, coffee vending machine etc as one time service during the contract period excluding emergency breakedown service all as directed 19 Supply and fix SMPS based automatic floot cum bost battery charging unit suitable for 12 volts lead acid battery 180 AH for existing fire fighting control panelwith following parameters Voltage 12 voltfrequency 50 HZ ,DC, current 10 to 20 amps, input up to 270 Volts, output 12 Volt, Short circuit, over volatge, reverse polarity protection, fan cooling type, auto cut system during the time of engine working condition including taking down unserviceable chrger unit all as directed 20 Supply and fix lead acid battery 12 volt 150 AH heavey duty model XP 1500for suitable for 60 hp pump set Make - Exide, Tata, Amaron 21 Supply and fix plain brass gas burner control valves two way of size 25 to 30 mm hospital grade suitable for existing MS LPG gas pipe line including taking down old valves all as directed 22 Supply and fix hospital grade vertical mount torch type or V type heavey duty burner plain brass suitable for existing MS LPG gas pipe line and cleaning of burner/stove area including taking down old valves all as directed 23 Supply and fix rubber steel wire reinforced LPG safety gas pipe hose IS/ISO certified of length 1.5 Mtr longred including taking down old gas pipe any type all as directed 24 Supply and fix low pressure LPG gas regulator of HP/Indane/Bharat fixed with exsisting pipe line including taking down unserviceable regulator all as directed 25 Supply and fix pressure gauge 820 cm dia dial 0 to 21 kgs rating in any position including taking down unserviceable pressure gauge all as directed 26 Metrial and labour for cleaning of sedimended sludge fromSTP sump of capacity approx 30KL complete in any location, racking of sedimented sludge by using mechanical equipments and water pressure jets to made easy to pumping the sludge after neuralisation of harmful gases any type in sumincluding removing of sludgefrom sump by using the sludge removal pumps to sludge removel vehicle and transport to desiggnated place indicated by corporation authority and disposed off properlly, after cleaning of sump treated with necessary chemicals all as directed at site(Note - (i) No of loads will be calculated after cleaning of the tank Approx sludge capacity of veh 6500 ltr (ii) cleaning chemicals, mechanical equipments, water pressure jet assembly deemed to be included in quated rate (iii) Necessary arrangement for workforce/veh to eassy approch STP provided by the contractor without any extra cost 27 Material and labour for leak rectification in any size of fire fighting pipe line in any situation and height including necessary cutting/welding in MS pipeline, making good as per existing finish, necessary earth work were require at site all as directed 28 Supply and fix butterfly valve 80 mm dia with necessary nut bolts washer, gaskets including taking down unserviceable valve in any situation/height, necessary welding/cutting where required and making good the surface with existing finish all as directed 29 Supply and fix in replacement gun metalgatevalve heavy duly ISI marked with iron wheel head screwed both ends for iron pipes 25 mm bore dia including taking down unserviceable valve all as directed . 30 Supply and fix in MCCB 4 Pole, 415V, adjustable type, 160 Amps with Breaking Capacity 36 KA of existing frame including taking down unserviceable MCCB all as specified and as directed. Make L&T, Havells, ABB, C&S 31 Supply and fix in MCCB 4 Pole, 415V, adjustable type, 200 Amps with Breaking Capacity 36 KA of existing frameincluding taking down unserviceable MCCBall as specified and as directed. Make L&T, Havells, ABB, C&S 32 Supply, layig, connecting, testing and commissioning of16 Sqmm 4 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Make: Havells/Polycab/Finolex/Paragon/Gloster/Nicco 33 Supply, layig, connecting, testing and commissioning of6 Sqmm 4 Core LT cable XLPE/PVC insulat insulated un armoured heavy duty electric cable stranded copper conductor 1100 volts laid in ductfloor, fixed to walls/drawn through pipe, duct or along the pole, fixing the cable with suitable size glands, bottle type lugs etc all as specified and directed. Make:Havells/Polycab/Finolex/Paragon/ Gloster/Nicco 34 All as per item No 33 above 4 Sq mm 3 core 35 Material and labour for Sub main wiring by surface/ in any situation complete with 2 runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20/25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface in wall/Ceiling etcfrom Main DB to sub DB /poleall as specified and as directed by engr - in- charge. Note :- 2 runs of 1.5 sqmm, + 1 run of 1.5 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. 36 Supply and lay reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm all as directed.