| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-09-2025 |
| 2 | 26-08-2025 | Corrigendum 01 | BOQ | 06-09-2025 |
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) areanot exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and asdirected. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) areaexceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and asdirected. |
| 3 | Taking down shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and removing from site complete all as specified and asdirected. |
| 4 | Dismantling boarding any description fixed in any position as in cup board, cabinet, false ceiling etccomplete all as specified and asdirected. |
| 5 | Supply and fixing factory made uPVC white colour casement (Open-able, double shutter glazed and wire guage, Net Opening area not exceeding 1Sqm ) window/ventilator made of extruded profiles with wall thickness of 2.3mm (± 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 ± 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Including Hardware:[casement handle made of zinc alloyed (white powder coated), But Hinges of\"zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and including 5mm thick toughened glass and Wire cloth Stainless steel 304 Grade, natural finish, 0.36 mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 6 | Supply and fixing factory made uPVC white colour Three track three panels sliding window (area exceeding 1 Sqm and not exceeding 2 Sqm) with fly proof SS wire mesh (Two nos. glazed& one no. wire mesh panels) upto 1.50m height made of (big series) frame 90 x 42 mm & sash 31 x 57 mm both having wall thickness of 2.3 ± 0.2 mm and single/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality (as per approved sample), including 5mm thick toughened glass and Wire cloth Stainless steel 304 Grade, natural finish, 0.36 mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 7 | Supply and fixing factory made uPVC white colour Three track three panels sliding window (area exceeding 2 Sqm) with fly proof SS wire mesh (Two nos. glazed& one no. wire mesh panels) upto 1.50m height made of (big series) frame 90 x 42 mm & sash 31 x 57 mm both having wall thickness of 2.3 ± 0.2 mm and single/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality (as per approved sample), including 5mm thick toughened glass and Wire cloth Stainless steel 304 Grade, natural finish, 0.36 mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed. |
| 8 | Supply and fixing factory made uPVC white colour fixed glazed ventilator made of frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, including Glass- 5mm thick tinted or figured glass pin head type complete all as specified and as directed. |
| 9 | Note for uPVC Window/VentilatorNote :(i) The cost of glass, wire meshand all other connected accessories shall deemed to be included in the quoted unit rate. (ii) Net Opening will be measured for payment purpose. (iii) Cutting holes of suitable depth in wall for inserting lugs etc including making good dismantled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate and cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles ± 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 10 | Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 11 | Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 12 | Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 13 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos. per leaf |
| 14 | Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos. per leaf |
| 15 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) decorative type glazed/gauge skelton door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with butt hinges with necessary full body threaded star headed counter sunk S.S screws including S&F wire cloth complete all as per direction of Engineer- In- Charge including supply and fixing following items:-(a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos. per leaf(f) Stainless Steel (304 Grade) (natural finish) wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm, fixing as per manufacture |
| 16 | Note for WPC/uPVC Frame/window/shutter(a) Test certificate of Manufacturer to be provided by contractor.(b) Embossing with Barcode of Manufacturer engraved over each door Frame & shutter is mandatory. |
| 17 | Material and labour for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed.Note :- (i) Glass panes & wire mesh shall be measured and paid separately under respective item of Sch |
| 18 | Material and labour for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges, pivots, Aluminium mongery/fittings and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed.Note :- (i) Glass panes & wire mesh shall be measured and paid separately under respective item of Sch |
| 19 | Material and labour forAnodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed. |
| 20 | Note for Aluminium Frame, Door. Window and Grill(a) The weight of Aluminium section/Frame or complete door/wndow and aluminium grill shall be physically ascertained through a board of officers convened by CWE and payment shall be made only after the actual weight at site.(b) The weight shall be measured before fixing the glass/wiremesh. |
| 21 | Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed complete all as specified and as directed by Engineer-in- charge |
| 22 | Supply & fixing 4mm thick sheet glass ordinary quality in squares / retangular in any size of each pane and fixed complete all as specified & directed by Engineer-in- charge. |
| 23 | Supply & fixing 4mm thick figured glass pin head type in squares / retangular not exceeding 0.5sqm in each pane and fixed complete all as specified & directed. |
| 24 | Supply & fixing aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (IS Marked) complete all as per direction of Engineer- in-Charge |
| 25 | Material and labour for roller venetian blinds including rails, runners, strips and opening/closing arrangement fixed to opening such as window/ventilators etc. complete all as specified and as directed. |
| 26 | M & L for modular kitchen (kitchen cabinet bottom unit, over head wall unit, Loft unit, Cup board etc ) made out of HDHMR board 18/19mm thick, density over 850kg/Cum having a class A fire rating, interior grade, both side pre-laminated, shutters fixed with soft auto closing hinges, shelves fixed with brackets/cleats as required, SS handles fixed on shutters and fixing baskets/trolley of any type as required complete all as specified and directed. Note:(i) Accessories such as basket/trolley, hinges, GI channels, handles shall be measured and paid separately as supply only. Other minor items not otherwise described shall be deemed to be included in the unit rate quoted(ii)The actual net area of HDHMR board as fixed at site shall be measured for payment.(iii) The 3 D design/ drawing of the modular kitchen/cabinets etc shall be provided by the GE before execution of the work. |
| 27 | M & L for modular kitchen (kitchen cabinet bottom unit, over head wall unit, Loft unit, Cup board etc ) made out of HDHMR board 18/19mm thick, density over 850kg/Cum having a class A fire rating, interior grade, both side laminated using acrylic sheet 1.50mm thick, shutters fixed with soft auto closing hinges, shelves fixed with brackets/cleats as required, SS handles fixed on shutters and fixing baskets/trolley of any type as required complete all as specified and directed.Note:(i) Accessories such as basket/trolley, hinges, GI channels, handles shall be measured and paid separately as supply only. Other minor items not otherwise described shall be deemed to be included in the unit rate quoted(ii)The actual net area of HDHMR board as fixed at site shall be measured for payment.(iii) The 3 D design/ drawing of the modular kitchen/cabinets etc shall be provided by the GE before execution of the work. |
| 28 | Supply only soft closing/self closing concealed hinges, SS304 grade, partial overlay / fully overlay, nickel finish complete all as specified and as directed.Make :- Hafele / Godrej / Hettich / Blum |
| 29 | Supply only soft closing/self closing Telescopic channels (drawer slides or drawer runners suitable for depth of BOX 560mm), galvanized steel zinc coated, suitable for min 35 Kg weight complete all as specified and as directed.Make :- Hafele / Godrej / Hettich / Blum |
| 30 | Supply only Handle 100mm size, SS304 grade, nickel finish, fancy type complete all as specified and as directed. |
| 31 | Supply only following accessories (grain/oil pullout/utensils etc) for modular kitchen cabinet, made out of stainless steel 316 grade complete all as specified and as directed.(a) Cutlery basket (b) Cup & saucer basket (c) Plate (Thali) basket (d) Detergent holder (e) Oil bottle pullout basket (f) Grain Trolley (g) Plain tray (h) Dustbin HolderMake :- Hafele / Godrej / Hettich / Blum |
| 32 | Supply & fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, Overall length of cover plate 150mm, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & fixing 100mm longaluminum anodised hasp & staple, safetytype,with hinge pin including bolt to hinge plate fixed with and including SS screws complete all asspecified and directed. |
| 34 | Supply and fixing mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate and fixing to frame with steel screw complete all as specified and as directed. |
| 35 | Supply and fixing Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed. |
| 36 | Supply and fixing stainless steel pipe 25mm bore (as a curtain rod), wall thickness of pipe not less than 1mm and grade SS 202, fixed in position with fixing accessories like Brackets, finial and side holder of same manufacturer including taking down old existing curtain rod any type complete all as specified and as directed.Note : (i) Brackets, finial and side holder shall be measured and paid separately for supply only but the cost for fixing the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.(ii) Cost for screws, rawl plugs as required for fixing shall also shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 37 | Supply only stainless steel 202 grade brackets for fixing of 25mm bore curtain rods complete all as specified. |
| 38 | Supply only stainless steel 202 grade finials for fixing of 25mm bore curtain rods complete all as specified. |
| 39 | Supply only stainless steel 202 grade side holder for fixing of 25mm bore curtain rods complete all as specified. |
| 40 | S&F Gl frame work for ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including hangers 6 mm dia. GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long at any height and position complete all as specified and as directed. |
| 41 | S&F 6mm thick non asbestos fibre cement designer building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed. |
| 42 | S&F of 5mm thick aluminium composite panel (ACP) of approved colour, fire / UV / Fuel / smoke and heat-resistance type, confirming to ASTM 4956 type-IV or above for wall cladding or ceiling at any height or position including with all necessary fixing arrangements and writing / printing of letters, numbers, comma, dashes etc with retro reflective tape, cut to size (Block, italic, Roman etc. upto 30 cm high) using computerised cutter plotter & pneumatic automated squeeze roll applicatorcomplete all as specified and as directed. |
| 43 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position and including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed. |
| 44 | Dismantling of floor hearth or wall tilling/terrazzo including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed. |
| 45 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium (1st) quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed. |
| 46 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium (1st) quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed. |
| 47 | Ditto all as above item non skid ceramic tile as in skirting, but tiles laid over and including 10 mm thick bedding layer in cement mortar (1:3) complete all as specified and as directed. |
| 48 | Material and labour for Double charge vitrified coloured tiles (approved shade) of size 600mm x 600mm or above having thickness 8 to 9 mm premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed. Make : Johnson (Snow Flair/Albano White Plus/Albano Lemon Plus) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 49 | Ditto all as above item but as in skirting, but tiles laid over and including 10 mm thick bedding layer in cement mortar (1:3) complete all as specified and as directed. |
| 50 | Material and labour for Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic coloured tiles in approved shade, size exceeding 0.06sqm and not exceeding 0.18sqm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white cement with pigment to match the colour of tiles complete all as specified.Note : Dado should be flushed with the wall plastering.Make : Johnson (Digital HD Tiles) (Barstow DK/LT/HL for Toilets & Verona LT/HL for Kitchens) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 51 | Material and labour for Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic coloured tiles in approved shade, size 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white cement with pigment to match the colour of tiles complete all as specified.Note : Dado should be flushed with the wall plastering.Make : Johnson (Digital HD Tiles) (Barstow DK/LT/HL for Toilets & Verona LT/HL for Kitchens) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 52 | Dismantling of stone slab tiling including cement mortar bedding ( but not backing) and including removing rubbish material from building and thrown in low lying empty area at any distance as direccted from the site complete all as specified and as directed. |
| 53 | Material and labour 16-18mm thick approved shade green marble, machine cut, duly factory grinding and polishing (table rubbed and polished)as in cooking platform, in steps, jambs, pillars, window-cills, for counter sunk wash basin and like or where directed laid over and including 15mm thick cement mortar (1:4) screed bed including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble, including cutting as required including cleaning and extra polishing if required complete all as specified and as directed.Note : Single piece should be used in steps/cills/jambs/shelves/ equal to width of slab, including accomodate the hole for gas pipe in cooking platform and chamfering/rounding the outer edges, nothing extra shall be paid on this account. |
| 54 | Material and labour 18-20mm thick approved shade Granite, machine cut, duly factory grinding and polishing (table rubbed and polished)as in cooking platform, in steps, jambs, pillars, window-cills, for counter sunk wash basin and like or where directed laid over and including 15mm thick cement mortar (1:4) screed bed including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble, including cutting as required including cleaning and extra polishing if required complete all as specified and as directed.Note : Single piece should be used in steps/cills/jambs/shelves/ equal to width of slab, including accomodate the hole for gas pipe in cooking platform and chamfering/rounding the outer edges, nothing extra shall be paid on this account. |
| 55 | Material and labour for machine cut18-20mm thick (minimum), Kota stone slab (size of slab not less than 550x500mm for flooring and in single piece for treads of staircase, laid over and including 20 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding andpolishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Material and labour for machine cut 15-18mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding and polishing by machine, including machine cutting to make it square or rectangularcomplete all as specified and as directed by Engineer-in-Charge. |
| 57 | Material and labour for rubbing /grinding andpolishing upto glossy finish by machine to old existing kota stone flooring, including repairing of joints/cracks with cement complete all as specified and as directed by Engineer-in-Charge. |
| 58 | Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, in post hole, bed block& similar work etc including form work complete all as specified and as directed by Engineer-in-charge. |
| 59 | Material and labour for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, hard standing, path etc, laid in suitable panels not exceeding 3.00 m length finished even and smooth without using extra cement, 10mm Joints filledwithbituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and directed. |
| 60 | Dismantling of interlocking tile/paver block/brick etc (laid flat or on edge etc) laid dry or pointed complete all as specified and as directed. |
| 61 | Material and labour for hard core of broken stone or boulders of gauge exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge. |
| 62 | Material and labour for 100mm thickcement concrete ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 63 | Material and labour for 75mm thickcement concrete ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 64 | Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, mud stops, packing sides/around of interlocking tiles, bed block, for embedded posts & similar work etc including weatherings, slightly rounded or chamfered angles complete all as specified and as directed by Engineer-in-charge. |
| 65 | Supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block/ interlocking tile of M-35 grade, prepolished & preglazed, with approved colour, design & pattern (laid in required colour & pattern as directed) as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 66 | Supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block/ interlocking tile of M-40 grade, prepolished & preglazed, with approved colour, design & pattern (laid in required colour & pattern as directed) as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 67 | Supply and laying at or near ground level factory made kerb stone of M-20 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 68 | Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge. |
| 69 | Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS),including special shaped washers, bending and welding etc, complete all as specified and as directed by the Engineer-in-Charge. |
| 70 | Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar ncluding removing from the site complete all as specified and as directed. |
| 71 | Demolition/taking out any type roof treatment, any thickness, like mud phuska/brick coba, APP membraneetc from roofs,including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including cleaning of surface of loose dust, and dirt and cement slurry etc. by means of wire brush, dust removing brush and scraper etc. and washing with water and preparing the roof surface to receive further treatmentincluding removing rubbish material from building and thrown in low lying empty area at any distance upto 5 KM as direccted complete all as specified and as directed.Note :- Only Plan area of roof will be measured for payment.Cost for removing/cutting uprooting grass, vegetations etc from area for surrounding/parapit wall etc shall deemed to be included in unit rate quoted, nothing extra shall be admissible on this account. |
| 72 | Material and labour for repair of surface with GP-2 (General Purpose Grout) or repair mortar uto 15mm thick as per site condition/ manufacturer’s instruction and including cracks shall be repaired with cement admixed with polymer as per manufacturer’s instructions complete all as specified and as directed.Make of material : Sika /Fosroc / Pidilite / Asian Paints / MBTCC (BASF) or Techno commercial equivalent make approved by CWE in writing from E-in-C\"s Br approved list |
| 73 | M and L for cleaning surface of any loose dust, dirt or slurry by means of wire brush, dust removing brush etc. after preparation of surface treated with PU epoxy primer to seal the pores and enhance the adhesive of the coating, after primer applying single component waterproofing liquid membrane based on pure, polyurethane resin cold applied with spray, applied PU membrane shall be UV resistant with SRI (Sun Reflective Index) of 98 with an elongation of 650% +50 and tensile strength not less than 2Mpa. No leakage upto five bars of water pressure. Shore hardness >70 shall be 2.00mm (overall) DFT (Dry film thickness), In two or more layers (each layer minimum 750 micron) or as per manufacturer’s instructions so as to achieve thickness not less than 2.00mm DFT complete all as specified and as directed.Make of material : Sika /Fosroc / Pidilite / Asian Paints / MBTCC (BASF) or Techno commercial equivalent make approved by CWE in writing from E-in-C\"s Br approved listNote: - (i) Payment will be made after providing warranty certificate for 10 years from the company. (ii)The thickness of the PU membrane shall be checked with cut and seal method and the third-party test to be carried out from NABL approved lab. The sample size for check should be 50x50mm randomly at any location and kept in record. |
| 74 | Material and labour for Providing PCC coving/ gola along vertical parapets of size 75 mm X 75 mm with concrete M20 (Nominal Mix) using 20 mm crushed stone aggregate including supply and mixing liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg complete all as specified and as directed. |
| 75 | Material and labour for 25mm average thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in roof slab padding, increasing uniformly towards ridges to maintain a chain slope, the top shall be trowelled and finishing the surface even amd smooth complete all as specified and directed by Engineer-in-Charge. |
| 76 | Demolition of cement concrete and digging out (unreinforced) as in sunken floor of any description and in any position and including removing rubbish material from building and thrown in low lying empty area at any distance as directed from the site complete all as specified and as directed. |
| 77 | Material and labour forwater proofing treatment to RCC sunken slab and adjoining vertical slab as described following any one method complete as per directions of GE. |
| 78 | Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B)Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment.(D)40 mm dia HDPE pipe to be provided as spout pipe in sunken portion. |
| 79 | Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slabsurface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.(D)40 mm dia HDPE pipe to be provided as spout pipe in sunken portion. |
| 80 | Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in make mentioned in Appx \"B\"approved by CWE Note :- (i)The treatment shall be carried out by authorised applicator (through specialized agency ) approved by CWE as per the manufacturer.(ii) PCC filling under sunken area will be measured & paid separately (iii) Treatment should be conitue upto 450mm height on vertical wall of sunken but only plan area of sunken will be measured for payment. |
| 81 | Material & Labour for PCC (1:5:10) type E2 using 40mm graded AAC sludge/bats as filling of sunken floors complete all as specified and as directed. |
| 82 | Supply and fixing chicken wire mesh( Murga jali ) in cement plaster or over joints of RCC and brickwork or as per site requirement of 24 gauge & 12 mm mesh and 300 mm width for construction joints and chasing in brick work for electrical conduits or water supply pipes and pegs/nails with nailing machine as required before rendering / plastering etc. as per site requirement complete all as specified and as directed.Note: Rendering / plastering shall be measured and paid separately under respective item of BOQ |
| 83 | Material and Labour forCarefully chipping, removing existing loose/ damaged concrete with plaster from column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operateddiamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower and including removing rubbish material from building and thrown in low lying empty area at any distance as directed from the site complete all as specified and as directed.Note:- Mode of measurement : per sqm of breaking area of concrete only. |
| 84 | Material and Labour for Cleaning all existing reinforcement bars in column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, complete all as specified and as directed.Note :- Mode of measurement: per sqm of breaking area of concrete only.Make: Sika- Rustoff 100/Fosroc- Reebaklens RR/ OM AGRO- DERUSTER / Pidilite Dr Fixit Rust Remover / Asian Paints Apcorep Rust Rem / MBTCC (BASF) or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 85 | Material and Labour for Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min0.4 kg/Sqm approx) in column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed, the product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and as directed.Note :- Mode of measurement: per sqm of application area of concrete.Make: Sika- Friazinc R/Fosroc- Nitozinc Primer/ Pidilite Dr Fixit Zinc Rich Primer / Asian Paints Apcorep Rust coat RB / MBTCC (BASF) or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 86 | Material and Labour for Apply SBRbasedbondingagenttotheentireconcretesurfacepriortobuildingupofconcretewith Polymer modified mortar or any other treatment, including cleaning the surface to remove dirt, dust or anyotherimpuritiesoncolumn, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed complete all as specified and as directed.Make: Sika - SikaDur 32 LP / Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP) / MBTCC (BASF) or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 87 | Material and Labour forRebuilding the section of structural damaged RCC/PCC elements of column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength>= 50 N/Sqmm (28 days) according to ASTM C 109, flexural strength >= 5N/Sqmm (7 days) according to ASTM C-293-79 complete all as specified and as directed. Make: Sika / Fosroc /Pidilite Dr Fixit or Techno commercial equivalent in make mentioned in Appx \"B\"approved by CWE Note:- Mode of measurement : per sqm of breaking area of concrete only. |
| 88 | Material and Labour forRebuilding the section of structural damaged RCC/PCC elements of column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed repair to spalling concrete to its original size and shape in additional layers of 10 mm uniform thickness for subsequent layers by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength>= 50 N/Sqmm (28 days) according to ASTM C 109, flexural strength >= 5N/Sqmm (7 days) according to ASTM C-293-79 complete all as specified and as directed. Make: Sika / Fosroc /Pidilite Dr Fixit or Techno commercial equivalent in make mentioned in Appx \"B\"approved by CWE Note:- Mode of measurement : per sqm of breaking area of concrete only. |
| 89 | Material and Labour forProviding and filling ready mix Polymers Modified Mortar (PMM) in grooves of any depth in column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed in layers upto required thickness to reach the surface level not exceeding 20mm at a time.PMM shall have compressive strength >= 50/sqmm (28 days) according to ASTM C 109; flexural strength >=5N/ sqmm (7 days) accordign to ASTM C 293-79 complete all as specified and as directed.Make: Sika / Fosroc /Pidilite Dr Fixit / MBTCC (BASF) or Techno commercial equivalent in make mentioned in Appx \"B\"approved by CWE |
| 90 | M&Lfor drilling and cementitious injection grouting in the prefixed nozzle, using plasticized expanding grout admixture cementitious grouts MBT Non- shrinkage material having mixed with cement @ 225 gms per 50kg of cement. Fix the drill and fix 10-12 mm dia, 50-75 mm long PVC injection packers at approved spacing as per methodology, not less than 3 Nos per Sqm in cleaned holes with fast setting mortar. Later cleaning the treatment and start grouting with pressure machine. Later the nozzles shall be cut, and space shall be refilled with SBR modified mortar. Using 140 PSI pressure grouting machine for the complete work. All work shall be executed as per direction of Engineer-in-charge, Including all Material, Labour, Tools and Machinery etc. for column, roof beam, plinth beam, roof slab, ceiling, chajja, fascia, fins, drops and similar surface where directed after thermal scanning the structural member complete all as specified and as directed.Make of material : Sika /Fosroc / Pidilite / Asian Paints / MBTCC (BASF) or Techno commercial equivalent make approved by GE in writing from E-in-C\"s Br approved list. |
| 91 | Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed. |
| 92 | Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed. |
| 93 | Supply & fixing of 20mm outer dia CPVC pipes SDR 11 including all fittings Plain/brass threaded CPVC SDR 11 (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 94 | Supply & fixing of 25mm outer dia CPVC pipes SDR 11 including all fittings Plain/brass threaded CPVC SDR 11 (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 95 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 96 | Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling or laid in floor including cutting and threading of pipe complete all as specified and as directed. |
| 97 | NOTE FOR CPVC/GI PIPES : (i)Pipes inside the buildings shall be fixed concealed and outside the buildings shall be fixed on the surface along wall with clamps/brackets. (ii) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (iii) Where concealed pipe laying in new location (other than taking out old pipe location) then cutting chases in wall shall be measured & paid separately under relevant item of BOQ. |
| 98 | Material and labour for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing, cutting not exc 10 cm girth in brick wall and making good, complete all as specified and as directed by the Engineer-in-Charge. |
| 99 | Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection including dismantling/taking down old water storage tanks of any description and capicity with float valve and gate valve complete all as specified and as directed. |
| 100 | Supply & fixing rotational mouldedpolyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection including dismantling/taking down old water storage tanks of any description and capicity with float valve and gate valve complete all as specified and as directed. |
| 101 | Supply and fixing CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 20mm bore iron pipes and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 102 | Supply and fixing CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 25mm bore iron pipes and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 103 | Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed. |
| 104 | Taking down old Bib tap/Angular stop cock/basin mixer valve/pillar cock/Shower etc complete all as specified and as directed. |
| 105 | Supply and fixing Bib taps,CP,fency type long body with wall flange screwed for 15mm bore brass ferrule and fixed in position complete all as specified and as directed.Make : Jaquar (Cat No. VGP-81037) (Vintage Prime) or equivalent from Cera (Valentina Single Lever Series) or equivalent from Hindware (Fluid Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 106 | Supply and fixing Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore brass ferrule or for union and fixed in position complete all as specified and as directed.Make : Jaquar(Cat No. VGP-81053) (Vintage Prime) or equivalent from Cera (Valentina Single Lever Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 107 | Supply and fixing 2 Way Angle Valve, Stop Cock, with Wall Flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore brass ferrule and fixed in position complete all as specified and as directed.Make : Hindware (cat No F740006CP) or equivalent from Jaquar / Cera (Valentina Single Lever Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 108 | Supply and fixing Stop valves, fancy type, CP with long shank and cup ( concealed type ), exposed part kit with wall flange and regular body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete all as specified and as directed.Make : Jaquar(Cat No. VGP-81083K (Vintage Prime) & ALD 083) or equivalent from Cera (Valentina Single Lever Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 109 | Supply and fixing central hole basin mixer valve with regular spout, 15mm bore, brass chromium plated, for mixing hot & cold water, complete with fittings, 450mm long braided hoses with connection and nut for WHB complete all as specified and as directed.Make : Jaquar (Cat No. CQT-CHR-23167B or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 110 | Supply and fixing Wall Mixer Non-Telephonic Shower Arrangement with Connecting Legs & Wall Flanges, screwed down for brass ferrule suitable for fixing to wall, complete all as specified and as directed. Make : Jaquar (Cat No. CQT-23219) or equivalent from Hindware (Fluid Series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 111 | Supply and fixing Chromium plated overhead shower with Rubit Cleaning System (Square Shape Single Flow) of size 200mm X 200mm with shower arm of 450mm long 20mm dia round shape with 90º bend for wall mounted shower with flange of same make and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified.Make : Jaquar (Shower-OHS-35497, Shower Arm-SHA-479L450) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 112 | Supply and fixing Chromium plated overhead shower 100mm dia with shower arm of 450mm long 20mm dia round shape with 90º bend for wall mounted shower with flange of same make and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified.Make : Jaquar (Shower-OHS-1989, Shower Arm-SHA-479L450) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 113 | Supply and fixing Stainless Steel Towel Rack 600mm Long Without Lower Hangers but with 3 hooks,including all fixing fixing accessories, fixed in position including taking out any type towel rail/ring complete all as specified and as directed. CAT PART No. ACN-1181FHS of Jaquar or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 114 | Supply and fixing Stainless Steel Single Towel Rail 20mm dia, 60 cm long between flanges and including all fixing fixing accessories, fixed in position including taking out any type towel rail/ring complete all as specified and as directed. CAT PART No. AKP-35711PS of Jaquar or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 115 | Supply and fixing Stainless Steel Towel Ring including all fixing fixing accessories, fixed in position including taking out any type towel rail/ring complete all as specified and as directed. CAT PART No. CAN-1121BN of Jaquar or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 116 | Supply and fixing Toilet Roll Holder with Stainless Steel Flap complete all as specified and as directed. Make - Jaguar Cat Part No ACN-1153S or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 117 | Supply and fixingin replacement PVC Bathroom mirror cabinet of appx size 450mm X 350mm X 140mm / 450mm X 380mm X 140mm (Compact Mirror Cabinet, Concealed shelves) approved quality complete all as specified and as directed. |
| 118 | Supply and fixing soap dish, stainless steel of suitable size to accommodate soap, tooth brush glass and tooth paste complete all as specified and as directed. |
| 119 | Supply and fixing Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and as directed. |
| 120 | Supply and fixing Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 121 | Supply and fixing Soap Dispenser chromium plated with Glass bottle, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed.Cat part No AKP-35735P of Jaquar or Techno commercial equivalent in make mentioned in Appx \"B\" |
| 122 | Supply and fixing sheet glass corner assembly of 300X300mm/250x250mm for corners consisting of 5.5mm thick glass shelf and with bevelled edges/hatching of edges fixed with stainless steel\"D\" bracket fixed and railing complete all as specified and as directed.Cat part No ACN-1173 of Jaquar or Techno commercial equivalent in make mentioned in Appx \"B\" |
| 123 | Supply and fixing in replacement any size as directed bevelled edge mirror of selected quality 6-6.3mm thick glass mounted on PVC sheet and shall be fixed at wall with CP studs, complete all as specified and directed by Engineer-in-Charge. |
| 124 | Supply and fixing PVC connection 15 mm size of length 600 mm with PTMT nuts of approved qualitycomplete all as specified and as directed. |
| 125 | Supply and fixing PVC connection 15 mm size of length 450 mm with PTMT nuts of approved qualitycomplete all as specified and as directed. |
| 126 | Supply & fixing in replacement vitreous china Oval Shape Table Top Basin Size (mm) 465 x 475 x 185, Ceramic Wash Basin, white, including 32mm chromium plated waste coupling and PVC waste pipe including fixing material for wash basin on granite slab and including making hole in granite slab for coupling, and taking down existing WHB of any description/size complete all as specified and as directed.Make : Jaquar (JDS-WHT-25903) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 127 | Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe (flexible)600mm long including bracket and cutting for and pinning in end of bracket or erecting with long screwed shanks & fly-nuts, flange end bedded in red lead cement complete all as specified and as directed. |
| 128 | Supply and fixing vitreous china premium/1st quality wall hung water closet with P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc., and incl. plastic soft close seat cover as recommended by manufacturer for particular model closed pattern with flat bottom etc; and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges, SS jet spray with 01 mtr long PVC pipe with CP connector etc as recommended by manufacturer for fixing, packing and taking down existing WC with cistern of any description/size complete in all respect all as specified.Make : Jaquar (Continental Series-CNS-WHT-963N or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 129 | Supply and fixing health faucet (Hand Shower) fancy type, CP including 1.2 meter long 8mm dia wasy flex tube in chrome finish and including wall hook and fixing material, making connections and fixed in position complete all as specified and as directed. Make: Jaquar(continental series) ALD-573 / Hindware (contessa plus series)/ Cera (Ocean series) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 130 | Supply and fixingconcealed flushing cistern of PVC 8 ltr. cap with dual flushing system, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and \"S\" type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including S&F of actuator knob/flush plates and and taking down existing of any description/size complete in all respect all as specified.Make : Jaquar (Concealed Cistern-JCS-WHT-2400S, Flush Plate-JCP-CHR-812415) or Techno commercial equivalent in make mentioned in Appendix \"B\" |
| 131 | Supply & fixingin replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed. |
| 132 | Supply & fixing in replacement vitreous China squatting pan \"Orissa\" pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including cast iron \"P\" or \"S\" trap set 100mm bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed. |
| 133 | Supply and fixing in replacement 10 litres capacityPVCvalveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handleincluding brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge. |
| 134 | Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs,bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling, 32mm dia waste pipe and water spreader, pointing around urinal back in cement mortar,including taking down old urinal with fittings complete all as specified & directed by Engineer-in-charge. |
| 135 | Supply & fixing waste fittings/coupling 32/40mm dia CP, including waste pipe and rubber packing complete all as specified and as directed. |
| 136 | Taking down any type of soil waste, vent pipe, rain water pipes (PVC/CI any size or pattern) including all fittings, heads, shoes, bends, swan-neck etc fixed along wall complete as specified and as directed by Engineer-in- charge |
| 137 | Supply & fixing 110mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls with clamps/brackets and pipe keeping 100mm away from wall,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture grade \"B\" like bend/tees of any radious/junction (double T/Y, socket)equal or unequal (fittings with or without access door as per requirements and as directed), reducer any type, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 138 | Supply & fixing 75mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls with clamps/brackets and pipe keeping 100mm away from wall,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture grade \"B\" like bend/tees of any radious/junction (double T/socket)equal or unequal (fittings with or without access door as per requirements and as directed), reducer any type, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 139 | Supply & fixing 50mm bore uPVC pipesgrade \"B\"single socketedin any length with rubber ring joints, fixed along walls with clamps/brackets and pipe keeping 100mm away from wall or fixed as a spout/over flow pipe of tank,joints fixed with pipe joint lubricant including uPVC fittings/ Fixture grade \"B\" like bend/tees, vent cowls etc., complete all as specified and as directed.Note:- (i) Bracket, clamp, nut bolt, fastner, slotted channel etc shall be measured & paid separately under relevant item of BOQ. (ii) The testing for leakage of pipe shall be done before completion as directed by AGE. (iii) The separate pipes shall be provided for Sewage and drain system in all floors, No combination should be done. |
| 140 | Supply & fixing Bracket, Stack clamp, nut bolt, fastner, slotted channel etc suitable for uPVC pipe of any dia 110/75/50mm and for CPVC pipe of dia 20/25/40mm, all made out of Galvanised iron material with hot dip zinc aluminium flake coated, size and shape of bracket and clamp as directed so that pipe keeping 100mm away from wall complete all as specified and as directed.Note :- The weight of Bracket, Stack clamp, nut bolt, fastner, slotted channel etc shall be physically ascertained through a board of officers convened by GE and payment shall be made only after the actual weight at site. |
| 141 | Supply & fixing in replacement uPVCgrade \"B\"P trap 110mm bore with stainless steel grating including jointing with pipe joint lubricant, including PCC work complete all as specified and as directed. |
| 142 | Supply & fixing in replacement uPVCgrade \"B\"floor trap 110mm bore long neck with stainless steel grating including jointing with pipe joint lubricant, including PCC work complete all as specified and as directed. |
| 143 | Supply and fixing gully trap(IP) of Polyethylene (PE) material, of size 110mmX110mm (square) with socket type SPG including cover complete all as per manufacturer\"s instructions and complete all as specified and as directed. |
| 144 | Supply & fixing in replacement PVC (SWR) gully trap 125 X 110 mm, type b, setting and jointing with solvent cementcomplete all as specified and as directed. |
| 145 | Supply & fixing stainless steel Grating 125 mm dia with or without waste hole complete all as specified and as directed. |
| 146 | Taking down cement plaster from brickwalls/soffits of roof projections & chajjas /ceilings etc. including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. |
| 147 | Material and labour for rendering/plastering 15mm thick with ready mix cement plaster material on external surface of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 148 | Material and labour for rendering/plastering 12mm thick with ready mix cement plaster material on internal surface of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 149 | Material and labour for rendering/plastering 5mm thick with ready mix cement plaster material on concrete surfaces of ceiling, finished fair and evencomplete all as specified and as directed. |
| 150 | Dismantling of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed. |
| 151 | Dismantling of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including removing rubbish from the site complete all as specified and as directed. |
| 152 | Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 153 | Material and labour for brick workin half brick thick wall with sub class \"B\" burnt clay bricks (old size ), straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed. |
| 154 | Material and labour for brick work(old serviceable bricks obtained from dismantled itemshall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 155 | Demolition of cement concrete reinforced of any description such as roof slab, slab, beam, staircase, landing chajja, kitchen chimney, OHT staging, fins, shelves, etc, including reinforcement cut as required to facilitate demolition and prepare the surface to casting/jointing newincluding removing rubbish material from building and thrown in low lying empty area at any distance from the site complete all as specified and as directed. |
| 156 | Material and labour for reinforced cement concrete M-25 (Nominal mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 157 | Material and labour for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 158 | Material and labour for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in walls, retaining walls, basement wall, ballast walls and the like, any thickness above top of footing including attached pilasters and buttresses complete all as specified and directed by Engineer-in-Charge.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.appropriate item of this schedule. |
| 159 | Material and labour for reinforced cement concrete M-30 (Design mix) using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels any span and the like complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 160 | Material and labour for reinforced cement concrete M-30 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule. |
| 161 | Material and labour for reinforced cement concrete M-30 (Design mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of BOQ. |
| 162 | Material and labour for mild steel TMT bars 10mm dia & over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 163 | Material and labour for mild steel TMT bars 6 to 8 mmdiacut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 164 | Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge.(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose) |
| 165 | Form work tosides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits of foundation and plinth beams and similar work vertical or to betterrough finished flat complete all as specified & directed by Engineer-in- charge. |
| 166 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter rough finished complete all as specified and as directed. |
| 167 | Form work toflat sides and soffits offloor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar worksrough finished flat surfaces complete all as specified & directed by Engineer-in- charge. |
| 168 | Form work tosidesof pillars , posts, struts piers, columns and stanchions and similar worksrough finished complete all as specified & directed by Engineer-in- charge. |
| 169 | Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed. |
| 170 | Material and labour for covering the crumple joint between walls, beams, columns by 0.56 mm thick, 240mm wide Plain Aluminium sheeting,Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)after plastering including taking down old sheet complete all as specified and as directed. |
| 171 | Material and labour for mild steel Framed work such as grills, guard bars, ladder, cooler stand, as door frame, railing, cloth drying provision, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work including welding work as required conforming to Fe.290.Gde-E-165 including taking down any framed work complete all as specified and as directed. |
| 172 | Material and labour for preparation ofnew steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (1st quality) of approved tint/colour over a coat of red oxide primer with using paint brush complete all as specified and as directed. |
| 173 | Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by complete removal of existing treatment and cleaning the dust and removing all loose particle & applying two coats of synthetic enamel paint (1st quality) of approved tint/colour over a coat of red oxide primer with using paint brush complete as specified and as directed. |
| 174 | Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying two coats of french polish complete as specified and as directed by Engineer-in-Charge. |
| 175 | Material and labour for complete removal of existing treatment of any type/description from external/internal wall/ceiling surfaces, soffits/chajja/roof projection surfaces etc., by Mechanical sander/grinder machine having suction vaccum Bag (Smart periodical methodology), complete all as specified and as directed. |
| 176 | Material and labour for new plastered surfaces and prepared surface after complete removal, applying acrylic wall putty in internal/external walls/RCC surfaces/soffits of chajjas/roof projections / cantilevers / balcony / ceilings etc (thickness vary from 1.5 to 2 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 177 | Material and labour for applying 02 coats of interior acrylic emulsion paint of approved tint/shade (Company Depot Tinted) @ 12 sq.m/litre/2 coats to wall surfaces (internal verticle new or old prepared surface after applying wall putty) over a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion brands by using airless spray gun/roller brush complete all as specified and directed. |
| 178 | Material and labour for applying 02 coats @ 5 sqm/litre/02 coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior emulsion paint of approved tint/shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 11 Sqm /litre/ 1 coat as recommended for under coat by manufacturer of exterior emulsion brands to external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (new or old prepared surface after applying wall putty) by using airless spray gun/roller brush complete all as specified and directed. |
| 179 | Material and labour for Preparation of new plastered or old surface after complete removal as in ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed. |
| 180 | Material and labour for Preparation of old decorated surfaces (plastered / unplastered) of ceiling by remove / scraping down allloose treatment etc with using broom /steel patti / wire brush / sand papering or by any other mean including applyingwall putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth, and after preparing the surface smooth applying one coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed. |
| 181 | Material and labour for preparation of new concrete surface / kerb stone surfaces of any description not otherwise described over 10cm width or girth, by cleaning the dust and removing all loose particle with using clean cloths, brooms and dry paint brush etc and after preparing the surfaces applying two coats of water based road marking paint(1st quality) of approved tint/colour (one colour or alternative colour as directed) complete as specified and as directed by Engineer-in-Charge. |
| 182 | Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying twocoats of cement base paint as per approved tint/colour with using paint brush complete all as specified and as directed by Engineer-in-Charge. |
| 183 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed |
| 184 | Surface dressing not exceeding 15cm deep in soft/ loose soilincluding cutting of grass, roots, bushes if any and removing from site all grass, roots and extra soil if any complete all asspecified and as directed by Engineer-in-Charge. |
| 185 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches, , for pipe line/cable trenches, for manholes or drains etc (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and as directed. |
| 186 | Excavation in trenches (Manual), not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe/cable and laying new pipe/cable etc. not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 187 | Excavation in trenches (Manual), exceeding 1.5m but not exceeding 3m wide and not exceeding 1.5m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe/cable and laying new pipe/cable etc. not exceeding 10 Sqm on plan and getting out in any type of soft including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 188 | Excavation over area (Manual), not exceeding 1.5 metre deep and getting out in any type of soil complete all as specified and as directed. |
| 189 | Excavation over area (Manual), exceeding 1.5 metre but not exceeding 3 metre deep and getting out in any type of soil complete all as specified and as directed. |
| 190 | Excavation over area (Manual), exceeding 3 metre but not exceeding 4.5 metre deep and getting out in any type of soil complete all as specified and as directed. |
| 191 | Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge. |
| 192 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 193 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 194 | Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and including 150 mm bore pipes complete all as specified and directed. |
| 195 | Supply and laying DWCPE (SN8) for non-pressure underground drainage and Sewerage drain pipe 150mm nominal dia, Type B, confirming to 16098 (Part 2):2013 (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated), laid in trenches on and including 100mm thick beding layer comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed. |
| 196 | Supply and laying DWCPE (SN8) for non-pressure underground drainage and Sewerage drain pipe 200mm nominal dia, Type B, confirming to 16098 (Part 2):2013 (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated), laid in trenches on and including 100mm thick beding layer comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed. |
| 197 | Supply and laying DWCPE (SN8) for non-pressure underground drainage and Sewerage drain pipe 300mm nominal dia, Type B, confirming to 16098 (Part 2):2013 (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated), laid in trenches on and including 100mm thick beding layer comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed. |
| 198 | Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in cradles or bed of pipe including packing under and haunching against the sides of pipes (where required as per site requirement only) after they are laid and tested complete all as specified and as directed. |
| 199 | Supply and fixing PFRC (Polymer fibre Reinforcement concrete) cover 600mm diameter having high load-bearing capacity, fixed & set over manhole in CM 1:4 including PCC benching in (1:2:4) and finishing smooth complete all as specifed and directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 200 | Supply and fixing readymade PVC, Polyethylene (PE) manhole Base of size 1000 mm dia, 1200mm height, stay on and including PCC (1:4:8) base bed 100mm thick complete all as per manufacturer\"s instructions, including provision of inlet and outlet (number of inlet/outlet as directed as per site requirement) suitable for 160/200/250/300mm dia pipe, complete all as specified and as directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 201 | Supply and fixing readymade PVC, Polyethylene (PE) Manhole shaft pipe 600mm long suitable for Polyethylene (PE) 1000mm dia manhole base to maintain the required height of manhole as per ground requirement, fixing/sealed with \"O\" ringscomplete all as per manufacturer\"s instructions and complete all as specified and as directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 202 | Supply and fixing readymade PVC, Polyethylene (PE) Manhole shaft pipe 150mm long suitable for Polyethylene (PE) 1000mm dia manhole base/shaft to maintain the required height of manhole as per ground requirement, fixing/sealed with \"O\" ringscomplete all as per manufacturer\"s instructions and complete all as specified and as directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 203 | Supply and fixing readymade PVC, Polyethylene (PE) Manhole Cone, Single piece of size 600mm dia on top and 1000mm dia at base, 600mm height, suitable for Polyethylene (PE) 1000mm dia manhole base/shaft, fixing/sealed with \"O\" rings/with Rubber seal complete all as per manufacturer\"s instructions and complete all as specified and as directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 204 | Supplying, installing, testing, and commissioning a high-grade Polyvinyl Chloride (PVC) grease trap with a nominal capacity of 100 liters (nominal liquid volume) with cover, suitable for underground or under-sink installation as per site requirements, including all necessary fittings, connections, and accessories, for effective separation and retention of fats, oils, and greases (FOG) from kitchen and food service wastewater prior to discharge into the sewer system, Access Cover shall be easily removable and securely fitting for inspection and maintenance, Sealing: 100% watertight construction to prevent leaks and infiltration and the PVC material should exhibit excellent chemical resistance to typical kitchen wastewater components complete all as specified and as directed.Make Astral/Supreme/Nilkamal Limited/Pars Ethylene Kish Co |
| 205 | Material and labour for boring of holes (trenchless horizontel hole at any depth upto 2.5 m)under main road pavement, hard standing or any other situation by using trenchless boring machine/mechanically or by manual manpower suitable for inserting any type of pipe any dia 150-300mm in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed.NOTE:- Pipe for inserting as required shall be measured and paid for separately |
| 206 | Supplying, installing, commissioning and testing of Non-clog vertical Submersible pump for handling sewage water and having discharge of minimum 141 LPM and 21M head, 415 Volts, 50 Hz, 2900 RPM, \"F\" Cl insulation, IP 68 protection, 40 degree centigrade operating temperature with CI Impellor, CI motor body, CI pump housing, stainless steel shaft and delivery pipe size of 50mm including hoisting submersible sewage pump into sewage collection tank using suitable stainless steel heavy duty (Gde 316) chain and anchoring with hook on top of sewage tank with necessary nuts, bolts, washers etc complete all as specified and as directed. |
| 207 | Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and as directed. |
| 208 | Material and labour for Cutting into existing manholes for connecting new drains 150 mm dia to 300mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete as specified and as directed by Engineer-in- charge |
| 209 | Providing Modular Operation Theatre of internal size 6400mmx5030mmx2590mm, including Prefabricated puff panels fire retardant with antifungal coating, plenum with laminar flow conductive vinyl flooring, hinged doors, hermetically sealed sliding door (automatic with sensor), pressure relief damper (stainless steel), aluminium ducting, air return grills, AHU and condensing unit, LED x-ray viewing Screen, magnetic writing list board, complete in all respects as per manufacturer design and as per following specifications and as directed.Note :- (i)The design /drg/specification amd manufacturer of Modular Operation Theatre shall be got approved from Accepting Officer before procurement of the item.(ii) OT control panel (Touchscreen/Membrane type), LED peripheral lights, single arm pendent, double dome LED OT lights shall be measured and paid separately under respective item of Sch |
| 210 | WALL, CORNER & CEILING PANELS: Pre Fabricated puf Wall panel Ceiling Panels and corners panels. PUF Panels, between both sheets of PPGI / GI having PUF density of 40kg/m3 with proper supports. Ceiling Panels will be supported with Brick wall thru L type Flashing, ceiling support system as required. (PPGI Sheet Make‐ Tata steel / Bhushan / Jindal / National). Panels including cutouts for Lights, Pendants, electrical switch‐sockets etc. |
| 211 | Antifungal Paint Coating :- Jointless Coatings for puf Wall, Ceiling & Corner Panels, Filling of all joints & cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial & antifungal paint equivalent to a minimum dry film thickness of 300 microns. |
| 212 | Plenum Laminar Flow :- Planair Ceiling mounted system with unidirectional airflow , Plenum unit will be made of Aluminum sheet to insure rust free surface, Holding structure will be in galvanized steel sheet duly powder coated & Top plenum are conforming to DIN 4799 standards for the air distribution system complete with 6 Nos HEPA Filters (efficiency 99.97% down to 0.3 m ). (Plenum size 2400 mm x 2600 mm). Diffuser are made out of Aluminum perforation for laminar of filtered air. Diffusers will be fixed thru Aluminium / SS 304 extruded frame, sealing gasket and stainless steel screw which will not be exposed outside, It will be covered with sealing gasket. |
| 213 | Conductive Vinyl Flooring :- Seamless antistatic conductive ESD, anti-fungal vinyl flooring system, 2mm thick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting. Flooring in operation theater room will be seamless with perfectly curved flash-covings, resistance to mechanical stress and dynamic loads and having ESD/EMI (Conductive) protection characteristics, 2mm thick, washable vinyl. The conductive carbon coated PVC pellets create the permanent static-conductive properties. It complies with EN 649. Before laying the Flooring inside the Operation Theater a copper strip of width of 25 mm and thickness of 0.05mm is placed in such a way that each flooring tiles get connected to earthing. |
| 214 | Manual Sealed Hinged Door :- Manual Sealed Hinged Door in High Pressure Laminate ( HPL ) on both side & PUF/Honeycomb material will be filled between two sheets framed in aluminium extruded profile, Door size 1000 x 2100 or (as per site opening) complete with double toughened glass vision window of 300mm x 300mm, SS 304 door hinges make Dorset/Dorma, SS Handle, Door Closer make Dorset/Dorma, Door lock make Dorset/Dorma, sealing gasket & Automatic drop seal in bottom of door with required accessories. Door frame will be aluminium extruded profile duly anodized with sealing gasket. |
| 215 | Automatic Hermetically Sliding Door :- Automatic operated hermetically sealed sliding door with HighPressure Laminate on both side, Door size (1500mm wide 2100mm height) complete with double toughened glass vision window of 300mm x 300mm and smooth effortless sliding door runs on nylon wheel within an aluminum extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door. The doorframes consist of reinforced plasterboard panels faced with the same laminate as the door and will be edged with an aluminium extrusion and with concealed fixings that are adjustable during installation to ensure a 100% hermetic seal is achieved. Microcontroller based door automation unit complete with motor, touch less hand sensor 2nos, foot switch 2nos, safety beam sensor |
| 216 | Pressure Relief Damper :- Pressure Relief Dampers made out of 1.5mm thick blades with Balancing weight made out of Stainless steel & brass for maintaining the positive pressure inside the operation theatre complete with aluminium powder coated grill outside the OT. (size: 300mm x350mm). |
| 217 | Aluminium Ducting : - Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication. Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart. Thermal insulation with 9mm XLPE with aluminium foil for supply & return air ducts. Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 2 meters. No insulation is allowed inside the duct. |
| 218 | Air Return Grill :- Air Return Grill made of SS 304 / Alumi on each four corners. |
| 219 | AHU & Condensing Unit :- AHU System & Condensing Unit with consisting of following characterisitcs : AHU Unit : floor mounted air-cooled, double skinned AHU with following capacities of GI casing 0.6mm outer layers, o.6mm inside layer, with 25mm polyurethane insulation, with mixing chamber, 6 RD cooling coil, 0.1mm thickness aluminum fins, filters with 50mm aluminum/ washable pre and fine filter, belt drive motor of 50Hz, 3phase AC supply, drain connection etc. with complete as per these specification 3200 CFM with 80-20% Fresh Air, Static Pressure - 125.(Make :- FAN SECTION – KRUGER/ NIKOTRA, MOTOR – ABB /CG)Condensing Unit : Micro Processor controlled Air Cooled Condensing Unit of 8.5 TR) , hermetically sealed scroll compressor, refrigerant, complete with motor, condenser, fan of 3 phase connection, copper piping, insulation. (Make - VOLTAS / Dakin / Carrier )(a) AHU- Air handling Unit(b) AC Unit 8.5 TR ( 5.5 Ton X 1 Nos And 3.0 Ton X 1 Nos )(c) Copper Piping with Insulation for AC Condensing Unit (d) Gas Charging of AC (e) Internal Wiring of AHU & AC |
| 220 | LED - X-Ray Viewing Screen :- LED X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by switches mounted on front screen of Viewer. The system having electrical safety codes for high & Low voltage system. |
| 221 | Magnetic Writing List Board :- Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fiberboard sheet for additional rigidity. Writing board will be supplied with 02 Nos Duster & 02 Nos white board pens. |
| 222 | Supplying, installing and commissioning a 2-bay automatic surgical scrub sink of size L-1500mm x H-1450mmx D 600mm, fabricated from SS-304 grade stainless Steel with seamless welding and a polished, stain-resistant finish, the unit shall include a front access panel equipped with a thermostatic mixing valve (over trap) with an adjustable timer setting ranging from 1 to 3 minutes for hot & cold water, the system shall feature jaguar spouts, strainers, manual foot-operated bypass system and hands free operation via infrared sensor etc. complete all as specified and as directed.Make: Altos Engineers /Steris hybeat / PGK Clean air systems |
| 223 | Supplying, installing, commissioning and testing of hatch box made from SS-304 grade stainless steel, designed for disposal of dirty linen/waste. Each hatch shall be equipped with two electronically operated doors, configured to ensure that only one door can be opened at a time to maintain airlock integrity. A UV light shall be installed inside the hatch box and shall remain operational only when both doors are closed, UV light shall automatically switch off upon the opening of either doors. Visual indicators shall be provided on both sides to show the operational status of the hatch complete in all respects as per manufacturer design and specification and as directed.Make: Altos Engineers /Steris hybeat / PGK Clean air systems |
| 224 | Supply & Installation of Modular Glass Panel with 50 mm thick panels having composite construction of two skins with 8mm thick toughened glass with digital print and back with 0.8mm thick PPGI sheets with proper supports complete all as specified and as directed. |
| 225 | S&F in replacement 12mm thick toughened glass as in doors, partitionsand similar work including necessary fixing/supporting arrangements like cleats etc cutting to shape, drilling holes, design etc including taking down of existing any type with fittings complete all as specified and directed |
| 226 | S&F in replacement 8mm thick toughened glass as in doors, partitions and similar work including necessary fixing/supporting arrangements like cleats etc cutting to shape, drilling holes, design etc including taking down of existing any type with fittings complete all as specified and directed. |
| 227 | Supply and fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body cover with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed. |
| 228 | Supply and fixing Handle 250mm size, SS304 grade, nickel finish, fancy type suitable for glass door complete all as specified and as directed. |
| 229 | Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch socket with sheet, ceiling rose, lamp holder including rusted/broken concealed conduit, junction and sunken boxes etcand making good disturbed surface of walls/floors etc complete all as specified and as directed. |
| 230 | Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate white colour, any module as per requirements) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)including fixing ofswitch/socket etc complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).Note:- (i) Where ever it is not feasible to cable drawn through existing PVC conduit in roof slab (for ceiling fan point only) due to blocked, casing caping in lieu of pipe shall be provided by contractor without any extra cost, cost for the same shall deemed to be included in the quoted unit rate. |
| 231 | All as per above Srl item No. 216 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 232 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding i.e for phase, netural, earth wire etc) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switche / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate). |
| 233 | Material and labour for concealed Point wiring for one bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular bell switch (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate white colour, single module) suitable for fixing the modular bell switch, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)including fixing ofswitch/socket etc complete all as specified and as directed. (Bell switch shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ) |
| 234 | Material and labour for concealed Point wiring for onesocket out let 15/16 Amps point controlled by one switch/AC starter switch (on independant board) (using red, black and green colour wires as colour coding i.e for phase, netural, earth wire etc) complete with 4 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket/AC starter switch, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, AC starter switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate). |
| 235 | Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding i.e for phase, netural,earth wire etc) ) complete with 2.5 Sqmm(nominal cross section area) single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing ofswitches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 236 | Supply only modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed. |
| 237 | Supply only modular switch 6Amps, single pole, two way complete all as specified and as directed. |
| 238 | Supply only modular switch 16Amps, single pole, one way (1 module) complete all as specified and as directed. |
| 239 | Supply only modular Bell Push switch, 6Amps, single pole, one way (1 module) complete all as specified and as directed. |
| 240 | Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed. |
| 241 | Supply only modular Socket outlet multipurpose type 16 Amp, flush type (2 module) complete all as specified and as directed. |
| 242 | Supply and fixing modular stepped type (1-4/5), electronic Fan regulator, 100-120 watt,250 volts, (2 module) suitable for other than BLDC fan complete all as specified and as directed. |
| 243 | Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed. |
| 244 | Supply and fixingelectric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge. |
| 245 | Supply and fixing lamp holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 6Amps, complete all as specified and directed. |
| 246 | Supply and fixing LED lamp minimum 3 star rated 9/10W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications(a) Lumen system efficacy of lamp should be minimum 90 Lumen per watt.(b) Input Voltage range : 140 to 270 volts(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95(e) CRI: Morethan80 |
| 247 | Supply and fixing in replacement (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating 200 Amps, with two neutral bar, 2 earth bar and cable tie for cable management, including in built one number MCCB 4 pole 160Amp, 35KA as incomer,DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.. |
| 248 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) TPN, 4 Way, 415V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 249 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) TPN, 12 Way, 415V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 250 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way, 240V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 251 | Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way, 240V AC supply, As per IEC 61439-3, suitable for mounting Isolator/MCB, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed.Note :- MCB/ISOLATOR shall be measured and paid separately under appropriate item of BOQ. |
| 252 | Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply including taking down unserviceable old any type complete all as specified and as directed. |
| 253 | Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 40 to 63Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB/panel complete all as specified and as directed. |
| 254 | Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 63Amps, TP with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB/panel complete all as specified and as directed. |
| 255 | Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 to 63 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB/panel complete all as specified and as directed. |
| 256 | Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed. |
| 257 | Supply and fixing MCCB 125 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply, fixing in DB/panel complete all as specified and as directed. |
| 258 | Supply and fixing MCCB 200 Amps, Four pole, adjustable thermal magnetic protection, 36 KA, 415 V AC supply, fixing in DB/panel complete all as specified and as directed. |
| 259 | Taking down existing LED tubelight, bed side lamp, ceiling light, panel light, bulk head light etc of any size complete all as specified and as directed. |
| 260 | Taking down existing LED out door securoty/street light fitting with GI bracket & clamps of any size complete all as specified and as directed. |
| 261 | Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20Watt, appx 4 feet long, housing environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 262 | Supply and fixingLED light fitting 1 x 8/10Watt, appx 2 feet long LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap.(h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV.(l) CCT : Minimum 6000K(m) CRI : Minimum 80(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 263 | Supply and fixing LED Bulkhead fitting 1 x 9/10Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing, environment friendly, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories complete all as specified and as directed. |
| 264 | Supply and fixing recessed type, LED light fitting, 500 Lux, rectangular shape 2 feet x 1 feet, 220V AC, with high efficiency, PMMA diffuser soft glare free light complete with drivers, LED lamps including making connection complete all specified and as directed. |
| 265 | Supply and fixing recessed type, LED 34/35/36 Watt flat panel of size 600x600mm, 220V AC, with high efficiency, PMMA diffuser soft glare free light complete with drivers, LED lamps including making connection complete all specified and as directed. |
| 266 | Supply and fixing wall mounted bed side lamp with provision of lamp holder and 5 watt lamp, including electric connection with using suitable size flexible copper conductor cable, complete fitting with all accessories and following specifications, complete all as specified and as directed. :- (a) Lumen system efficacy of luminaire should be minimum 90 Lumen per watt.(b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20. (f) (e) CRI: Morethan80 |
| 267 | Supply and fixing energy efficient LED security light fitting of 45 W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5 Sqmm, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket along wall including painting to bracket, MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed. :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 268 | Taking down carefully existing sub main wiring three run/five run any size including rusted/broken concealed conduit, junction boxes etcand making good disturbed surface of walls/floors etc complete all as specified and as directed. |
| 269 | Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 4 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 270 | Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 6 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 271 | Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 10 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 272 | Material and labour for concealed sub main wiring (Five run i.e. 3 x phases and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 10 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 32mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :- Five run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 273 | Material and labour for concealed sub main wiring (Five run i.e. 3 x phases and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 16 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 32mm dia (medium quality ISI marked), on independent circuit from panel/DB including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, complete all as specified and as directed.Note :- Five run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 274 | Disconnectingelectric connection and taking down carefully ceiling fan, exhaust fan, Geyser complete with accessories and deposited to E/M store yard complete all as specified and as directed. |
| 275 | Supply and hanging /fixing ceiling fan 1200 mm sweep color white AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of \"B\" class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum with remote and remote holder (remote holder fixed on wall where directed), 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 276 | Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in opening in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making good of opening in wall if required for fixing of exhaust fan same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 277 | Supply and fixing ventilating Air axial flow Fan of size 250mm sweep, single phase, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with and including new 1 Sqmm, 2 core flexible copper conductor cable from ceiling rose to fan, complete all as specified and as directed.Note :- Serial Number of exhaust fan issued by Engr-In-Charge and GE Office name shall also be written on fan with red colour permanent marker.(ii) Cost for making good of opening in wall if required for fixing of exhaust fan same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 278 | Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body of capacity 25 litre with 2kw heating element, BEE approved 5 Star rating, 230 V, single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as having indicating light, safety valve, thermostat, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable and making connections with and including 15 amp top plug, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.(b) Serial Number of geyserissued by Engr-In-Charge and GE Office name shall also be written on geyser with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 279 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto main switch board, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 280 | Supplying, installing, commissioning and testing of Double Dome Shadow less OT Light with Ceiling Flange and Base Tube with Ceiling Fixed assembly. It should be European CE and US FDA registered it should be double dome with latest led technology confirm to standards for Medical electrical equipment IEC60601-1 and IEC 60601-2-41. Class 1 Protection. Consist of one main and One Satellite Light heads in Round Shape, complete in all respects as per manufacturer design and as per following specifications and as directed.Note :- Manufactured by a USFDA & CE European approved reputed company with experience in OT light Manufacture with past experience of supply to Military and Govt Hospitals and able to provide good post sale maintenance support and must give at least 3 Satisfactory Performance reports from Command/Military Hospitals and Government Hospitals |
| 281 | (a) Conform to standards for medical electrical equipment IEC60601-1 and IEC 60601-2-41. Class 1 Protection (b) Consist of One Main and One Satellite Light heads in Round Shape (c)Microprocessor controlled Hybrid LED technology with Sensors for Light obstruction and Depth Selection (d) Illumination provided by multiple high performance Hybrid LED (e) Illuminance (Lux) 160000 + 160000 lux(f) Led Housing with more than 95 Lamps and Dome size between 70-80 cms (g) LED life of 60000 hrs or more (h) The External construction should be made of high grade of ABS plastic being Electrical, Heat and Chemical resistant to ensure an efficient heat management for not more than 1 degree C temperature rise at surgeons head level (i) Illumination field of 18-30 cm dia (j) Variable Colour temperature 3600K to 5500K ± 100K (h) Colour rendering Index 99 or better for RA and R9 (k) Light held depth 65 to 120 cm (l) Intensity control 25-100% |
| 282 | (m) Intensity control 25-100% (n) Light head suspension should be fully cardanic and camera ready for future up gradation (o) Should not interfere with laminar flow system of the OT with turbulence intensity (matching as per DIN 1946-4 standards) at 13 -14% (p) Endo Light for enabling Laparoscopic Surgery Dim Illumination at 8000 Lux (q) Shadow Dilution with Tube to be 95%, With One Mask 90%, With 2 Masks 65%, With One Mask at base of Tube 85% and With 2 masks at base of Tube 60%. (r) Ingress Protection to be IP42 (s) Radiation Energy 3.7mW/m² lx and Illumination Energy 570W/m² (t) Sterilizable Handle and Touch sensitive Arm control to offer changing of illuminating field and control of intensity, Colour Temperature and Depth of Light and Synchronizing Both Light heads with each other. (u) SMPS to be 28V DC capacity (v) Remote cordless tablet PC for changing operating parameters. |
| 283 | (i) Should have an integrated/external uninterrupted power supply unit suitable for 01 Hour Backup(ii) Camera should be mounted on light head for displaying real-time images during surgery with a Coaxial camera chip of 1.28 CMOS or more than with 2.10 Megapixels capability with at least 12X Digital Zoom and 30X Optical Zoom. Full HD 1080p (1920x1080) image capture and external recording. Camera control should have function like Zoom In/Out, White Balance, Focus In/out, Auto, Aperture In/out, Freeze. All function of HD camera should be controllable through Andriod Tablet PC /voice control & touch Panel. It should be in HD formats 1080i: 1920 x 1080 pixels/60 frames / sec. Minimum Object distance 10 mm to 1200 mm. Focal Length 4.3 to 129 mm. Shutter Speed 1/1-1/10000(22 Steps). Signal Noise Ratio 50Db. Output 3G HD-SDI, SMPTE 424M and 292M |
| 284 | (iii) Wall Mounted Surgical Grade Monitor display 31-32 inch screen compatible for full HD (iv) Medical Recording Device with 5 inch touch screen preview of Video Recording and Archiving Device to capture HD photo (up to 1920x1080p) and medical session video recording (up to 1080p 60Hz). The system should simultaneously record to the 2 terabyte internal hard disk drive and an external USB flash drive. It should record 2 sources at once and play back 1 or 2 sources from the same video file. Files to be recorded through a Software for Digitizing and Archiving Data through a password protected to send images in HD-SDI Video Inputs. Simply Use Web Browser interface to access Data on Computer or Tablet Video Recording upto1080P at 60Hz. System controls can be managed using the touch screen and buttons on front of the unit.Should be suitable for storing HD videos from ultrasound, digital X-ray, endoscopic, laparoscopic and other compatible diagnostic and surgical imaging systems. |
| 285 | (v) Computer/Laptop for Data Management shall be of core i7 or more with latest features (vi) Integrated Wiring from OT\"s to Head of Department and Conference Room(vii) Supply and fixing of LED TV Monitor 55\" for display and Live Streaming of Surgical Procedures in the Head of Department and Conference Room from all the OTs. The TV shall be connected with integrated wire from OT\"S. (viii) Video Editing software should be accessible through Windows, very user friendly with MS Word like Ribbon UI, user Login screen to allow access only to authenticated users, inbuilt Patient-Visit-Image management feature. Multiple visits per patient are allowed. Video Editing software should stores & calculates Patient’s IN/OUT timings for defined procedures to measure the efficiency of work flow, Save video in AVI/MPEG/MP4 format with excellent video compression. Save storage space more than 90%.Video Editing software should be operated through USB footswitch support for capture/start/stop action for hands free functions, Audio recording for audio notes dictation. |
| 286 | Supply and fixing 22 inch Modular LCD Touch screen (Surgeon Control Panel) complete flush to wall including connections complete all as specified and directed. |
| 287 | Supply and fixing Double Arm moveable pendant (includes 2 Tray, 2 IV poles, 6 Gas Outlets & 8 Electrical Sockets (5/15 Amps) complete all as specified and directed. |
| 288 | Supply and fixing Detectors Complying with and type certified to EN-45 Addressable type multi sensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360, including taking out /down old any type complete all as specified and as directed. |
| 289 | Supply and fixing Loop powered sounder strobe, including taking out /down old any type complete all as specified and as directed. |
| 290 | Supply and fixing Addressable manual call point resettable type, including taking out /down old any type complete all as specified and as directed. |
| 291 | Supply and fixing FRLS PVC insulated unsheathed copper conductor armoured cable multistranded 2 x 1.5 sqmm (2 core) for connecting fire detector, test point and Hooters with control panel, including taking out /down old any type wiring complete all as specified and as directed. |
| 292 | Supply and fixing FRLS PVC insulated unsheathed copper conductor armoured cable multistranded 2 x 2.5 sqmm (2 core) for connecting Siren with control panel, including taking out /down old any type wiring complete all as specified and as directed. |
| 293 | Supply and fixing Fire alarm control panel complying with BS EN 54 Two loop panel of capacity from 99 detectors & 99 modules upto 200 detector, including taking out /down old any type complete all as specified and as directed. |
| 294 | Supply and fixing Termination Plexo Box size 80X80X75 mm for connection of cables of detector including brass gland, IP55 and IK07 rated, suitable for indoor and outdoor use, Halogen Free - Weatherproof, including taking out /down old any type complete all as specified and as directed. |
| 295 | Supply and fixing Sealed Maintenance Free Battery 12 volt 28 AH including Battery Box, including taking out /down old any type complete all as specified and as directed. |
| 296 | Supply and fixing Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 1500 meter range, including taking out /down old any type complete all as specified and as directed. |
| 297 | Supplying, installing, commissioning and testing of active Repeater panel (Remote Control Panel) with white backlit (240x64) graphical LCD Display, incorporates function buttons for silence, mute, resound, reset and disable/enable flash memory and advanced graphical display allows it to be easily configured to operate in virtually any language, with any character set and allows for the installer\"s logo and company details to be displayed on the LCD display during normal operation. Networked for system display and control, in-built fault-tolerant network card to network with compatible addressable panel (s) and repeater panel(s), fully on-site programmable via alphanumeric keypad or configuration software, panel housing meets min IP 30 ingress protection classification finished in RAL 7035, approved by: British Standards Institute (BSI) and vertrauen durch Sicherheit (VDS), independently certified as complying with requirements of BS EN 54 Part-2 & 4, including taking out /down old any type panel complete all as specified and as directed. |
| 298 | Supply and fixing Remote response indicators, including taking out /down old any type complete all as specified and as directed. |
| 299 | Supply, installation, testing & commissioning LT Panel board, indoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, outer body made out of 2mm thick & inner shell made out 1.6mm thick CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated and conforming to IEC-61439 part I & II, The cubical shall have frame work, bottom & 75CM base frame Angle iron, Aluminum main busbar of incomer switch gear duly sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and control wiring with multi-stranded PVC insulated copper wire size not less than 1.5 Sqmm, complete comprising with following accessories complete all as specified and directed. (Note: Feeder Pillar box shall be mounted on suitable size of channel as per OEM as directed. |
| 300 | Incomer TRANSFORMER 1 & 2(a)ACB EDO 2000 Amps(electrically operated Draw-Out type) 50 KAACB with Ics=Icu=Icw (1 sec), having Microprocessor based Releases -02 No(b)Digital Multifunction meter with LED display V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, On hours, Phase angle, Interrupts, THD, WITH RS485 (c)on/off/trip Indicator(d)LED indicating lamps (RYB) (e)Control Mcb 2A SP 10KA |
| 301 | Incomer DG 1 & 2(a)ACB EDO 2000 Amps(electrically operated Draw-Out type) 50 KAACB with Ics=Icu=Icw (1 sec), having Microprocessor based Releases -02 No(b)Digital Multifunction meter with LED display V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, On hours, Phase angle, Interrupts, THD, WITH RS485(c)on/off/trip Indicator(d)LED indicating lamps (RYB) (e)Control Mcb 2A SP 10KA |
| 302 | Incomer bus coupler 1, 2 & 3(a)ACB EDO 2000 Amps(electrically operated Draw-Out type) 50 KAACB with Ics=Icu=Icw (1 sec), having Microprocessor based Releases -03 No(b)Digital Multifunction meter with LED display V, A, F, PF, kW, kVA, Old energy, On and Run hours, site selectable kWh/ kVAh(c)on/off/trip Indicator(d)LED indicating lamps (RYB) (e)Control Mcb 2A SP 10KA |
| 303 | Outgoing -1(a)MCCB FP LT 415 volt 50 Hz, AC 400 Amps 36 KA with adjustable thermal setting With Extended Rotary Handle, Spreaders, Phase Barrier.-03 No(b)on/off/trip Indicator (c)Auxiliary 1 C/O + TAC 1 C/O(d) Control Mcb 2A SP 10KA(e) MCCB FP LT 415 volt 50 Hz, AC 250 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-03 No(f)on/off/trip Indicator (g)Auxiliary 1 C/O + TAC 1 C/O(h) Control Mcb 2A SP 10KA(j)MCCB 63A FP 10KA - 2No (FOR LIFT 1 & LIFT 2) |
| 304 | Outgoing -2(a)MCCB FP LT 415 volt 50 Hz, AC 400 Amps 36 KA with adjustable thermal setting With Extended Rotary Handle, Spreaders, Phase Barrier.-02 No(b)on/off/trip Indicator (c)Auxiliary 1 C/O + TAC 1 C/O(d) Control Mcb 2A SP 10KA(e) MCCB FP LT 415 volt 50 Hz, AC 250 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-04 No(f)on/off/trip Indicator (g)Auxiliary 1 C/O + TAC 1 C/O(h) Control Mcb 2A SP 10KA(j)MCCB FP LT 415 volt 50 Hz, AC 200 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-01 No(k)on/off/trip Indicator (l)Auxiliary 1 C/O + TAC 1 C/O(m) Control Mcb 2A SP 10KA(n)MCCB FP LT 415 volt 50 Hz, AC 160 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-01 No(o)on/off/trip Indicator (p)Auxiliary 1 C/O + TAC 1 C/O(q) Control Mcb 2A SP 10KA |
| 305 | Outgoing -3(a)MCCB FP LT 415 volt 50 Hz, AC 200 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-08 No(b)on/off/trip Indicator (c)Auxiliary 1 C/O + TAC 1 C/O(d) Control Mcb 2A SP 10KA(e) MCCB FP LT 415 volt 50 Hz, AC 100 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-01 No(f)on/off/trip Indicator (g)Auxiliary 1 C/O + TAC 1 C/O(h) Control Mcb 2A SP 10KA |
| 306 | Outgoing -4(a)MCCB FP LT 415 volt 50 Hz, AC 630 Amps 36 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-01 No(b)on/off/trip Indicator (c)Auxiliary 1 C/O + TAC 1 C/O(d) Control Mcb 2A SP 10KA(e) MCCB FP LT 415 volt 50 Hz, AC 250 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-01 No(f)on/off/trip Indicator (g)Auxiliary 1 C/O + TAC 1 C/O(h) Control Mcb 2A SP 10KA(j)MCCB FP LT 415 volt 50 Hz, AC 200 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-03 No(k)on/off/trip Indicator (l)Auxiliary 1 C/O + TAC 1 C/O(m) Control Mcb 2A SP 10KA(n)MCCB FP LT 415 volt 50 Hz, AC 63 Amps 25 KA with adjustable thermal setting WithExtended Rotary Handle, Spreaders, Phase Barrier.-04 No(o)on/off/trip Indicator (p)Auxiliary 1 C/O + TAC 1 C/O(q) Control Mcb 2A SP 10KA |
| 307 | NOTE:- The panel shall tested in presence of Engineer-in-charge and GE after installing. |
| 308 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing strip of size 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto the body of electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 309 | Design, Supply, installation, erection, testing and commissioning of Electrically operated Passenger cum Stretcher elevator all as per IS 14665 (Part 1 & 2) : 2000 (with latest amendment) for G+3, 04 Floors, suitable for existing shaft of size and as per following specifications, after and including taking out existing old unserviceable electrically operated Lift of any type and capacity including all connected accessories and depositing the same in MES E/M store yard complete all as specified and as directed. |
| 310 | (a) Capacity: 16 passengers, 1088 Kgs, (b) Speed: 1.0 mtr per second,(c) Machine and motor: Permanent Magnet Synchronous Electric Traction Gearless Motor,(d) Type of Drive: Microprocessor controlled AC V3F drive,(e) Number of floors/ stops: 04 Floors with 04 stops, 04 openings on one side. (f) Type of door opening : Telescopic/ centre opening type(g)Car size: Width 1200 x Depth 2100 x Height 2100 mm,(h) Head room : 4000 mm, (j) Car Enclosure: Scratch resistant stainless steel 304 of finish as approved by GE, (k)Door opening: 900 x 2000 mm, (l) Door opening mechanism: Automatic DC Door operation with adjustable door opening and closing timings, (m) Type of Control: Simplex full collective with or without attendant, Automatic operation, 415 Volts, 3 Phase, 50 Hz AC Supply, (n) Flooring: PVC/wooded Flooring, (o) Lighting: Diffused LED Lighting, (p) COP and LOP: Digital Seven Segment Direction and Position indicators in both car and at all Landings (q) Fire Rating: Two Hours (02 Hrs) with fire emergency switch. (r) Travel Height: 12 m. |
| 311 | (s) Traction Media : Steel rope (t) Car Finish : Rear Mid Panel, Rear Corner Panel, Side Mid Panels, Side Corner Panels, Front Panels all are made of Stainless Steel SS304 with honey comb finish (u) False Ceiling Finish : Stainless steel with hairline finish and with provision for LED lights (v) Ventilation : PVC heavy duty Cross Flow Fans (w) Hand Rails : Stainless Steel Finish round Handrails on rear car panels (x) Car door and Landing Door finish : Stainless steel SS-304, mirror finish outside(y) COP : COP (car operating panel) and LOP (landing operating panel) in Stainless Steel Hairline finish with display. (z) CAR POSITION INDICATOR : Dot Matrix type (aa) HALL FIXTURES : Dot Matrix type, FACE PLATE : Stainless steel hairline finish-SS-304 (ab) HALL BUTTON ARRANGEMENT: Hall and call Buttons with illumination and Braille(ac) Car and counter weight guide as per OEM recommendation (ad) Terminal buffers metal spring/oil buffer as per OEM recommendation (ae) STANDARD FEATURES :Anti-nuisance Car Call Protection, Independent Service, Overload Device, Nudging, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking Door Open/Close Button, Manual Rescue Operation, Auto Fan Cut Off, Over Speed Governor for Car, Floor announcement system in car cabin. |
| 312 | (af) Car Enclosure: Manufactured with stainless steel frame not less than 1.5mm with honey combfinish (SS-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED sleek light fittings (as per manufacturer’s instructions, minimum 04 Nos) operated on commercial supply and one LED light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection (ag) Safety Device: (i) Automatic Rescue Device (ARD), automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open. (iii) Emergency Firemen’s Service,(iv) Intercom(v) Overload Safety alarm |
| 313 | Design, Supply, installation, erection, testing and commissioning of Electrically operated Passenger cum Stretcher elevator all as per IS 14665 (Part 1 & 2) : 2000 (with latest amendment) for G+2, 03 Floors, suitable for existing shaft of size and as per following specifications, after and including taking out existing old unserviceable electrically operated Lift of any type and capacity including all connected accessories and depositing the same in MES E/M store yard complete all as specified and as directed. |
| 314 | (a) Capacity: 16 passengers, 1088 Kgs,(b) Speed: 1.0 mtr per second,(c) Machine and motor: Permanent Magnet Synchronous Electric Traction Gearless Motor, (d) Type of Drive: Microprocessor controlled AC V3F drive, (e) Number of floors/ stops: 03 Floors with 03 stops, 03 openings on one side. (f) Type of door opening : Telescopic/ centre opening type(g)Car size: Width 1200 x Depth 2100 x Height 2100 mm,(h) Head room : 4000 mm, (j) Car Enclosure: Scratch resistant stainless steel 304 of finish as approved by GE,(k)Door opening: 900 x 2000 mm, (l) Door opening mechanism: Automatic DC Door operation with adjustable door opening and closing timings, (m) Type of Control: Simplex full collective with or without attendant, Automatic operation, 415 Volts, 3 Phase, 50 Hz AC Supply,(n) Flooring: PVC/wooden Flooring, (o) Lighting: Diffused LED Lighting, (p) COP and LOP: Digital Seven Segment Direction and Position indicators in both car and at all Landings (q) Fire Rating: Two Hours (02 Hrs) with fire emergency switch. (r) Travel Height: 12 m. |
| 315 | (s) Traction Media : Steel rope (t) Car Finish : Rear Mid Panel, Rear Corner Panel, Side Mid Panels, Side Corner Panels, Front Panels all are made of Stainless Steel SS304 with honey comb finish (u) False Ceiling Finish : Stainless steel with hairline finish and with provision for LED lights (v) Ventilation : PVC heavy duty Cross Flow Fans (w) Hand Rails : Stainless Steel Finish round Handrails on rear car panels (x) Car door and Landing Door finish : Stainless steel SS-304, mirror finish outside(y) COP : COP (car operating panel) and LOP (landing operating panel) in Stainless Steel Hairline finish with display. (z) CAR POSITION INDICATOR : Dot Matrix type (aa) HALL FIXTURES : Dot Matrix type, FACE PLATE : Stainless steel hairline finish-SS-304 (ab) HALL BUTTON ARRANGEMENT: Hall and call Buttons with illumination and Braille(ac) Car and counter weight guide as per OEM recommendation (ad) Terminal buffers metal spring/oil buffer as per OEM recommendation (ae) STANDARD FEATURES :Anti-nuisance Car Call Protection, Independent Service, Overload Device, Nudging, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking Door Open/Close Button, Manual Rescue Operation, Auto Fan Cut Off, Over Speed Governor for Car, Floor announcement system in car cabin. |
| 316 | (af) Car Enclosure: Manufactured with stainless steel frame not less than 1.5mm with honey combfinish (SS-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED sleek light fittings (as per manufacturer’s instructions, minimum 04 Nos) operated on commercial supply and one LED light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection (ag) Safety Device: (i) Automatic Rescue Device (ARD), automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. (ii) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open. (iii) Emergency Firemen’s Service,(iv) Intercom(v) Overload Safety alarm |
| 317 | Providing the services for comprehensive maintenance/comprehensive AMC of electric Passenger cum stretcher lift-02 Nos (Lift No 01 G+3 and Lift No 2 G+2 installed under above mentioned BOQ items) of capacity of 16 passenger (1088 Kgs) respectively, i.e Routine / Basic maintenance, performance monitoring, corrective maintenance, other services as specified in tender all as per maintenance schedule and manufacture\"s maintenance manual as per following complete all as specified and as directed.Note :- (i) Comprehensive maintenance/comprehensive AMC shall be carried out by personnel with the experience in the Lift and by manufacture\"s authorised personnel. |
| 318 | Comprehensive maintenance/comprehensive AMC for 1st year during defect liability period. |
| 319 | Comprehensive maintenance/comprehensive AMC for 2nd year during defect liability period. |
| 320 | Comprehensive maintenance/comprehensive AMC for 1st year after expiry of defect liability period. |
| 321 | Comprehensive maintenance/comprehensive AMC for 2nd year after expiry of defect liability period. |
| 322 | Comprehensive maintenance/comprehensive AMC for 3rd year after expiry of defect liability period. |
| 323 | Note for item No 284 :- The parts/ components shall be replaced any number of times during the contract period if it gets defective during the contract period. The contractor shall perform periodic overhauls and preventive maintenance required for the lift as per scope of Work and as specified in tender doc. The contractor’s quoted rate shall be inclusive of all the factors as per AMC and as specified. |