Tender For Repair /Maint/Servicing Of Power Supply/Distribution System Central S/S, C S/S, B S/S , E S/S Sre & Bcr Adjoing Locations And Connected Items In Domastic Area At Af Stn, Sulur, sulur-Tamil Nadu

Military Engineer Services has published Tender For Repair /Maint/Servicing Of Power Supply/Distribution System Central S/S, C S/S, B S/S , E S/S Sre & Bcr Adjoing Locations And Connected Items In Domastic Area At Af Stn, Sulur. Submission Date for this Tender is 21-08-2025. Overhead Line Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50600709
Tender For Repair /Maint/Servicing Of Power Supply/Distribution System Central S/S, C S/S, B S/S , E S/S Sre & Bcr Adjoing Locations And Connected Items In Domastic Area At Af Stn, Sulur
Tender
Indian
Tamil Nadu
Sulur
21-08-2025

Tender Documents

Tender Details

REPAIR /MAINT/SERVICING OF POWER SUPPLY/DISTRIBUTION SYSTEM CENTRAL S/S, C S/S, B S/S , E S/S SRE & BCR ADJOING LOCATIONS AND CONNECTED ITEMS IN DOMASTIC AREA AT AF STN, SULUR; SCHEDULE A BOQ 2 Supply andfix in repairHT, 11 KV grade, barrel fuse of capacity upto 40 Amps suitable for HT Switch fuse unit of Make ABB including taking down existing one complete all as spceified and directed. 3 Supply andfix in repair HT, 11 KV grade, barrel fuse of capacity upto 50 Amps suitable for HT LBSincluding taking down existing onecomplete all as spceified and directed. 4 Supply only Electrical Rubber hand gloves as perISI specification for operating voltage 11KV complete all as specified and as directed. 5 Supply and lay graded stone aggregate of 40mm size, spread and leveled around 4 pole/ 2 pole structure, transformer, sub stn, panel board yard including removal of existing complete all as specified and as directed. 6 Taking out existing old unservicable/burnt gang operated switches or DO fuse assys complete all as directed by the Engr-in-Charge. 7 S & Fswitch air break, gang operated, out door type, triple pole, HT 11000 volts, up to 400 Amps, vertical type with 3 insulators mounted with fixed contacts of phospor bronze and moving contacts of copper, manually operated from ground level with operating mechanism including mild steel galvanised light grade 25mm bore operating rod, pad locking arrangement,complete all as specified and directed by the Engr-in-Charge. 8 S & F in repairs drop out expulsion fuse assembly with fuse carrier, triple pole HT 11000 Volts, 200 Amps, out door type(having two Nos post insulators mounted on MS Channel for each pole ) complete all as specified and directed by the Engr-in-Charge. Make : PACTIL/JAIPURIA 9 S & F lightening arrestors Expulsion type complete with all fitting, transmission class, discharge capacity 10 kilo to 30 kilo Amps suitable for 11000 Volts and connecting to earth wire complete all as directedincluding taking down old u/s bursted lightning arrestors from Load break switch complete all as specified and directed. 10 S & F in repairs cable jointing kit for 1.1 KV grade cable for stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed. Make : Reychems, Densons, M-Seal 11 S & F in repair out door cable end jointing kit, inddor termination (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area185 Sqmm 3 corecomplete all as specified and directed Make : Reychems, Densons, M-Seal 12 Servicing the existing Drop out fuse assembly, of capacity 200 Amps, 11 KV, 3 Pole, including replacing worn out/ rusted nuts, bolts, clamps, washers, etc. and providing coloured sleaves for jumper connections complete. 13 Taking out and repairing / overhauling of air break gang operated switch 200 Amp, 11 KV capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally, replacement of broken/ worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly on contacts re-fixed the same after repair complete including new nut bolts and washer etc all as specified and directed.Note : The quoted rate by contractor shall include the serviceable parts in positionand replacement of U/S parts with new one. 14 Repairing, overhauling, Servicing & testing of RMUs, 11 KV, 20 KA, 3 Phase, 50 Hz, AC Supply system, outdoor type for trouble free operation, consisting of one/two incomming and one/two outgoingwith SF6 gas filled VCB/ LBS/Fuse units, metal clad totally enclosed free standing floor mounted, non draw out type includingthe following works complete all as specified and directed. Make of RMU : ABB 15 Note for Item No 14:- The Work shall be carried out through the authorised service engineers of the OEM only 16 (b)Servicing of Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism along with associated earthing switch. 17 (c)Servicing of true position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel for proper indication. 18 (d)Checking and tightening control wiring and rectifying the defects if any. 19 Repairing, overhauling, Servicing & testingof Vaccum circuit breaker11 KV, 630A to 800 Amps, 350/250 MVA, 66 KA Peak, 3 Phase, 50 Hz, AC Supply system, indoor type for trouble free operation, and VCBs are for incoming , Bus coupler & Bus riser and Outgoings ,metal clad totally enclosed free standing floor mounted type,and vaccum circuit breakers, draw out type HT VCBs includingthe following works complete all as specified and directed:- MRS (ABB/Siemens/CG/magawin) 20 Note for item No 15 :-(a) The rate for following shall be deemed to be included in quoted rate. 21 (b) The entire job shall be carried out through the authorised service engineers of the OEM only in the presence of Engineer-in-Charge/JE E/M. 22 (c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations. 23 (d) Servicing of 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system. 24 (e) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels. 25 (f) Servicing of Mech (caster lock) and elect inter locking system. 26 (g) Checking and tightening control wiring and rectifying the defects if any. 27 (h)Replacement of PTFuse 28 (j)Replacement of unserviceable spare parts will be measured and paid for separately. 29 (k)Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate. 30 (l)Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately. 31 Supply onlyagainst Item No. 14 above, Digital Microprocessor based Feeder protection Relay Model REF 615 for Over current and Earth fault including necessary necessary control wiring all as directed. 32 Supply only against Item No. 14 above, Electrical closing coil 110 volt DC operated all as directed. 33 Supply onlyagainst Item No.14 above, Electrical shunt trip coil 110 volt DC operated all as directed. 34 Supply only against Item No.14above,11 KV single phase in door resin cast CT of ratio 150/100/5A class 1.0/ 5P10,burden 15VA – 15 VA all as directed. 35 Supply onlyagainst Item No. 14above, Vaccum Interrupter (Vacum Bottle ) suitable for VCB all as directed. 36 Repair to transformer after disconnecting in coming HT connection and out going LT cable connection, draining out the transformer oil and keep in safe custody for reuse, disconnecting the breather assembly, temperature gauge, taking out the top cover of transformer 500 KVA, outdoor type, 11KV/433 Volt, step down, disconnecting LT/HT winding connections from LT/HT Bushing and carefully taking out LT/HT Bushing insulator and HT/LT Brass spindle, taking out gaskets of LT/HT Bushings and transformer top cover. Refixing exisiting LT/HT Brass spindle with Bushing insulators after replacing Gaskets, View glass of conservator tank, refixingall cable connections, top cover with new gasket, breather/temp gauge, refilling transformer oil, complete all as directed. 37 Note for item No 21 : (i) Transformer oil for topup, dehydration/filtration etc work will be measured and paid separately. 38 (ii) Complaints regarding Transformerwill be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days). 39 (iii) The contractor shall attend the complaint immediately. and shall report the Engr-in-Charge/JE( E/M) after completion. 40 (iv) Penalty of Rs 5000.00 per Job shall be applicable to the contractor if the complaint is not attended immediately. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 41 (v)The decision of the Accepting Officer in this regards shall be final and binding. 42 (vi) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC and thesame complaintshall be completed with in the period decided by the GE/EIC.The penalty of Rs 5000/ per Jobshall also be applicable to the contractorfor non-completion of complaint with in the time decided by the GE/EIC. 43 (vii) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof including tools and plants shall be deemed to be included in the unit rate quoted for this item. 44 (viii) Transformer oil shall be drained out by the contractor in suitable capacity mild steel drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be included in unit rate quoted against the respective item of this schedule. 45 (ix) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011at site in the presence of E-in- Charge/ JE and the cost of testing shall be deemed to be included in unit rate quoted against this item. 46 (x) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded. 47 All as per itemNo. 21 above but of capacity of transformer 160 KVA to 200 KVA. 48 All as per itemNo.21above but of capacity of transformer upto 100 KVA. 49 M & L removing HT cable, 11 KV, XLPE 185 Sqmm 3 core with aluminium conductor, shifting to other location (not exc 2 KM distance) and relaying same cable in trenches/through pipes or bare in road crossings/ paths/drains/ducts/ floors /along poles/walls/ ceilings/ equipments etc. all as directed. Note No 1 : The unit rate is deemed to be included for :-(a)Excavation for taking down existing cable, shifting of cable as directed by the Engineer-in-Charge and relaying cable including required excavation as specified in SSR Part-I.(b)Disposal and return filling.Note No 2 : Sand cushioning and PCC cover shall be measured and paid separatley under relevant item. 50 Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade,of cross sectional area 185 Sqmm x 3 core laid including taking down existing cable from trenches/ duct or any position all as specified and directed. 51 S & F Un-reinforced precast concrete cable cover class HV Type 1, flat size 300mm x 180 mm x 40 mm thick including taking down existing one of any size complete all as per specified and as directed. 52 S & Fin repairs Cable route indicators for HT cable with CI plate and angle iron 25x25x6mm showing MES,HT/LT cable,and voltage including excavation earth work and PCC complete all as per specified and as directed. . 53 S & F in repair Out door cable straight through jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (Earthed) grade, of cross sectional area 185 Sqmm 3 core complete all as per specified and as directed. 54 M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 300 sqm to 400 sqm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge . 55 M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 70 sqm to 95 sqm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge . 56 Note for Item No. 29 & 30 :- (i) The quoted unit rate deemed to be included for disconnecting the cable from the transformer/ LT panel/DBs and reconnecting the same after the insulation resistance test. 57 (ii) The insulation resistance shall be tested between the conductors. 58 (iii) The insulation resistance shall be tested between the conductor and armoured/ earth. 59 (iv) The contractor shall arrange necessary testing instruments of suitable range and cost for the same shall deem to be included in the quoted unit rate. 60 (v) Test to be conducted in the presence of MES rep and concerned user and will record it in prescribed format. Test records duly signed by all to be submitted by the contrator to the Engineer-in-charge. 61 (vi) If any damages found at end termination of the cable, same shall be rectified by using suitable size of lugs / nuts & bolts for the reconnection of cable in transformer/ LT Panel/ DBs. cost for the same shall deem to be included in the quoted unit rate. 62 (vii) Cost of earth work required for disconnecting and reconnecting the cable shall deem to be included in the quoted rate. 63 (viii) Any major item required to rectify the defect shall be measured and paid seperately. 64 (ix)Checking of earth resistance of chemical/conventional earthing, identifying the earth and recording of test results in a prescribed format all as directedby Engr-in-Charge. 65 M & L removing of acumulated earth of any width and depth up to 30 cm. cleaning/cutting the grass around two/ four pole structure, transformer yard,sub stn,generator rooms etc and removing the grass waste to outside MD land completed all as specified and as directed.Note :- The unit rate is deemed to be included :-(a)Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(b)Cutting the grass/feilling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shalll be carefully filled up with moorum/red bajri well rammed and levelled. 66 Supply and fixing HT tape roll 35mm width Appx 5 mtr length completed all as specified and as directed. 67 M & L for disconnecting in coming HT and out going LT cable connections and taking down Transformer of any type/size/make/capacity from 2/4 Pole structure or from floor/pedestal and shifting to new location with in 3 KM and install where directed, refixingHT/LT cable connections complete all as specified and directed. Note:-Any damages happened in transformer during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt 68 Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed. 69 Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed.. 70 Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.. 71 M & L riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. The rate is deemed to be included. 72 S & F XLPEinsulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 240 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note :- Necessary excavation and earth work, sand cushioning & bricks for protection shall be measured and paid separately. 73 M & L boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe heavy duty of size 100mm bore fixed in repairs complete all as specified and directed 74 M & L cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mmcomplete all as specified and directed. 75 Note for item No 40 :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :- 76 (i) Earth work excavation in any type of soil 77 (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. 78 (iii) Removing excavated material to out side MD land 79 (iv)Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately 80 (v)150 mm thickPCC 1:2:4 type B1 as in any type of road 81 Supply only GI pipe 100 mm bore medium grade for cable protection completeall as specified and as diercted by Engr-in-Charge.Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thickPCC 1:2:4 typeB1 as in any type of roadroadwill be measured and paid separately. 82 Supply andreplacement or topping up of transformer Oil HV as per IS 335 of 1983 Part II after dehydration & testinganddielectric strength not less than 40 KV complete all as spceified and directed.Note :- The transformer oil shall be supplied in sealed barrel and shall confirm to IS -335 (including all amendments upto date) 83 Supply only cottan / Baniyan waste 84 M & L Out door cable end jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area185 Sqmm 3 core complete all as specified and directed.Note:-(i)Taking out of existing cable, from VCBs, RMUs or Two Pole structuresand cutting faulty ends if required and re- fixing the same with out any damage of switch Gearsare deemed to be included in the item rate quoted)(ii) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days ). (iii) The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs (iv) Penalty of Rs 2000.00 per Job shall be applicable to the contractor if the complaint is not attended with in half anhrs. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. (v)The decision of the Accepting Officer in this regards shall be final and binding. (vi) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same. 85 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing oneall as directed. 86 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 87 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 88 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 89 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. 90 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 91 (vi) Copper strip of size 20 x 3 mm shouldbe fixed on proper post insulator at the instrument end ( The rate of earthing strip up to7.5 Mtrs is included in the quoted rate). 92 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concern. 93 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 94 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 95 (x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 96 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including dry or rocky soil. 97 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained. 98 (xiv) The electrode shallcarry manufacturers name . 99 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 100 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 101 (xvii)The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material. 102 (xviii) Sign boardof mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge. 103 (xix)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 104 S & F Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down existing one all as specified and directed.Note :- The contractor shall submit load bearing capacity certificate from the manufacturer. 105 S & F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. 106 Supply only against 14 of above Digital Microprocessor based Feeder protection Relayfor Over current and Earth fault including necessary control wiring all as directed. 107 M & L painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of transformer of rating upto 400 KVA using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM Nousing different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex) 108 Dismantling/taking down of insulators of any type/size from HT/LT poles/DOs/GODs complete all as directed by Engr-in-Charge. 109 S & F post type, HT 11 KV insulators suitable for GO/DO switch, duly tested and including making connections with proper size of thimbles complete all as specified and directed. 110 S & F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified. 111 S & F disc type insulator, porcelain, vitreous, 145 mm high and 255mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified. 112 M & L Painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of transformer of rating above 500 KVA using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM Nousing different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex) 113 Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KVor LT415 volt system, RMU,VCB,LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size. 114 Note for item No 55:(i) The abovework also include checking, detectionand rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M). 115 (ii) Hiring of cable fault detector to detect exact location of LT/HT UG cable fault deemed to be inclusive of quoted rate. 116 (iii) Major items required to be replaced/repaired will be measured under relevant items of schedule. 117 (iv) Excavation and earth work if required will be measured separately. 118 (v) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days). 119 (vi) In case of minor defect, entire job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300/- per hours shall be recovered. 120 (vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same. 121 (viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 500/- per hours shall be deducted from the dues of the contractor. 122 (ix)Note that penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding. 123 (x)Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon and after noon to collect routine/urgent works till completion of work. 124 Repair/Replacement ofstand alone HT Panel, 11 KV, 3 phase, 50Hz, 630A, 25 KA for 1 sec factory made, out door type cubicale fabricated out of CRCA sheet 3mm thick weather, dust and vermin proof, epoxy powder coated of IP-55 protection class with self contained air insulated compartment for bus bars and cable boxes with necessary support and 630A rated aluminium bus bar including cable galleries and provision of following switch gears including earthing switch, all pre-wiring with PVC copper conductor cable of suitable size including taking down of the unserviceable panel all as specified and as directed as per the below details :- 125 (a)Manually operated air break, load break switch alongwith earth switch and fuse trip mechanisum of HT HRC fuse - 50A, 230 V AC, Trip Coil and Aux Contact 2 No + 2NC. 126 (b)Space heater with ON/ OFF switch 10A, 230V AC. 127 (c)Emergency trip push botton - 01 128 (d)Cubicale illunination lamp with holder - 01 129 (e)Door limit switch, 230V AC. 130 (f)Provn of MCB, DP, 10A for control wiring. 131 (g)Provn of surge arrester 9 KV, 10 KA. 132 (h)Provn of thermostat 133 (j)Provn of indication lamp for LBS ON/ OFF, LBS E/S ON/ OFF 230V AC.Make of LBS shall be as mentioned in list of makes (PS). 134 S & F in repairsSurge arrester 9 kv /10 KV suitable for LBS ,RMU,VCB complete all as specified and as directed 135 Repair /Maint of old LT/HT Panels damaged doors,hinges ,indication Lamp RYB incluing welding work ,Power coating and lock and key complete all as directed 136 S&F MCCB, 4 Pole, 250 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 36 KA including connecting up using suitable size of copper lugs including taking down existing one complete all as specified and as directed. Make : L&T, Legrand, Siemens 137 Material and labour for finding faults of HT under ground cable XLPE 11 KV of any size up to 185 Sqmm by using computerised / primary current injection method /any other method and locating fault .Cutting removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site completeNote:-(i) Excavation earth work sand cushioning PCC coveretc will be measured and paid separately under relevant items of schedule here in after. (ii) Cable jointwill be measured and paid separately.(iii) Additional length of cable required at site for jointing will be measured and paid separately 138 Dehydration/Filteration of HV grade Transformer oilof transformer/switch gears minimum three cycles to achievedielectric strength not less than 40 KV for 1 minute with 2.5 mm Gap as per IS 335-1983 for HVgrade including topping up with new transformer oil complete all as specified and as directed 139 Note for Item No 61:-(i) Centrifuging Machine with all T & Pand testingmachine of oil, required for dehydration shall be arranged by contractor 140 (ii) Oil required for topping up the transformer will be measured & paid separately. 141 Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore medium grade including necessary Excavation in any type of soil, Returning, Filling and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. 142 Note for item No 62 :-(a)All Joints should be joined by Exothermic Welding or Brazing. 143 (b)The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately. 144 (c)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. 145 (d)Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. 146 (e)After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained. 147 S & F in repairs Galvanised Earth Strip of size 32x6mm as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. 148 Supply and fixingLT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of capacity upto 250 KVA including taking down u/s from the transformer complete all as specified and as directed 149 Supply and fixing LT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of above 250 KVA upto 500 KVA including taking down u/s from the transformer complete all as specified and as directed 150 Supply and fixing Breather assembly suitable for outdoor type transformerwithsilica Gel including taking down u/s from the transformer complete all as specified and as directed 151 Supply & filling silica gel inside breather assembly of trasformer complete all as specified and as directed 152 Repairing, overhauling, Servicing & testingof Air circuit breaker, 440V, 630 Amps to1600 Amps, 50 KA, 3 Phase, 50 Hz, AC Supply system,for trouble free operation,and draw out type Air Ciruit breaker including the following works complete all as specified and directed:- Makes ofACB :- C&S, Schneider, Siemens. Location - MAFI PS 1, Sub Stn B & D, Mehra Sub Stn, Simulator bldg, Avionic Eqpt bldg, EW block, ETB bldg, Electric logistic block, IFCS section, Mech CENGO section, Near LCA Hanger 153 Note for item No 68 :-(a)The rate for following shall be deemed to be included in quoted rate. 154 (b) The entire job shall be carried out through the authorised service engineers of the OEM only. 155 (c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations. 156 (d)Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the ACB trolly from the panels. 157 (e) Servicing of Mech/ elect inter locking system. 158 (f)Checking and tightening control wiring and rectifying the defects if any. 159 (g) Servicing of Mech (caster lock) and elect inter locking system. 160 (h) Checking and tightening control wiring and rectifying the defects if any. 161 (j)Replacement of PTFuse 162 (k)Replacement of unserviceable spare parts will be measured and paid for separately. 163 (l)Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate. 164 (m)Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately. 165 Supply only spring charging assembly including motor 230 V AC operated all as directed. 166 Supply only Electrical closing coil 230 volt AC operated all as directed. 167 Supply only Electrical shunt trip coil 230 volt AC operated all as directed. 168 S & F In repair LT, Air circuit breaker, operational voltage 415 to 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw outtype, rated current rating 630 amps and of breaking capacity not less than 50 KA with quick make, quick break, with manual operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed. Make : L&T/ Schneider/ Siemens/ABB 169 Repairing, overhauling, Servicing & testing of RMUs, 11 KV, 20 KA, 3 Phase, 50 Hz, AC Supply system, outdoor type for trouble free operation, consisting of one/two incomming and one/two outgoingwith SF6 gas filled VCB/ LBS/Fuse units, metal clad totally enclosed free standing floor mounted, non draw out type includingthe following works complete all as specified and directed. Make of RMU : ABB (Note : The Work shall be carried out through the authorised service engineers of the OEM only)(a) Servicing of Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism along with associated earthing switch (ii) Servicing of true position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel for proper indication (b) (e)Checking and tightening control wiring and rectifying the defects if any. 170 Supply, erect, Testing & Commissioning of Master trip electro mechanical relay, Single element high speed tripping relay with hand rest contacts.1/4N V,HR contacts complete control wiring with material, Programming/setting/calibration including softwareof relays required for CB proper operation and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay Make- ALSTOMorits techno commerical equivalent ABB/Scheinder /Siemens 171 Supply, erect, Testing & Commissioning of numerical directional Over Current & Earth fault relay,Directional power, residual/negative over voltage, under/over voltage, directional over current ,under/over frequency,CB fault detection, VT/CT supervision, all rms measurments: Model P3U30 incoming breakers as directed & specified ,complete M&L forcontrol wiring with material, Programming/setting/calibration to be done by OEM including softwareof relays as required for CB proper operation and necessary addition/alternation inpanel alongwith dismantling of old unserviceable old type of relay shall be deemed to be included in quoted rate.Make- Schneider orits techno commerical equivalent ABB/Semiens 172 M&L for calibration as directed& recommendedof all type of exisitng numerical relays/transformer protectionwith OEM recommended programmable settings,rewiring of control wiring,including all necessary elements for completeion of job all as specified and directed. 173 M&L for making of notice board/disply board by using foarm sheet with given letters, data etc red and blue colour letters including screws and paste in different sizes all as specified and directed by Engr-in-Charge. 174 M & L in replacement of signboard made out of SS frame and size of 1.5 Mtr x 1 Mtr box type withfine quality PVC sheet writing letter minimum letter size is 10 and 30 ltrs placing in side board with proper securing and fixing one 20watt LED tube light with control wiring from switch point all as specified and directed by Engr-in-Charge 175 M & L Painting using heat resisting spray paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of HT panel/VCBs using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM No and other required data using different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex)

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB