Tender For Provision Of Hard Standing With Covered Shed, Interlocking Tiles, Bathroom With Toilet, Septic Tank & Soakage Well Of Age B/R & Age E/M Under Ge Tenga.; 1 Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil. 2 Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed. 3 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil. 4 Excavation over areas n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed. 5 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin hard/dense soil complete all as specified and directed. 6 M&L for Pre-cast cement concrete block masonry type C-1 1:3:6(20mm graded agg) in CM 1:6 with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed. 7 Returning/filling in including spreading, levelling, watering and well remming in hard/dense soil. 8 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 9 Removing excavated material n exc100m and depositing where directed at a level n exc. 1.5 m above the starting point 10 M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces,finished even & smooth w/o using extra cement in CM 1:4 complete all as specified and directed. 11 M&L for Hard core, (broken srone or boulders) broken to gauge exc 63 mm and n exc 100mm complete all as specified and directed. 12 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. 13 M&L for 100mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as cement concrete in Sub-base floors, sub-bases floors and pavings etc complete all as specified. 14 M & L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compactedbed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified . 15 M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. 16 M&L forPCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases). 17 S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified. 18 S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. 19 S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed. 20 M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer. 21 M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement based paint,over a coat of whitewash complete all as specified and directed. 22 M&L PCC 1:4:8 type D2(using 40mm graded aggregate)as in foundation filling and mass concrete etc. 23 M & L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges type B1 1:2:4 (20mm graded aggregate) . 24 M&L for rendering 15 mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement. 25 M&L for Preparing newly plastered surfaces of walls and applying three coats of white wash. 26 M&L for 100mm thick PCC 1:4:8 type C2 (using 40 mm graded stone aggregate) as cdement concrete in Sub-base floors, sub-bases floors and pavings etc complete all as specified. 27 M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in sub base of floorings. 28 M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles complete all as specified and directed. 29 M & L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white coloured cement to match complete all as specified and directed. 30 M & L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finshed rough to receive tiles . 31 M & L for 350 x 250 x 7 mm/450 x 350 x 7 mm thick glazed coloured ceramic tiles on vertical surface of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. 32 M&L for 75 mm thick plain cement concrete type C-1, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement. 33 S & F 3mm thick figured glass, pin head glazing with oil putty /wooden beads in squares n exc 0.50 Sqm in each pane. 34 S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying and fixing in opening as per specification and drawing. 35 S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frameshall be covered with heat moulded plain colour PVC C channelhaving a PVC sheet strip of 20mm width stuckinside with solventcementfor stiles and plain colour PVC sheets for top rail, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frameat siteas per specification & drawing. 36 S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw etc. all as specified as directed. 37 S& F Aluminium anodised barrel tower bolts150mm long of extruded section and fixed 38 S & F 150mm size extruded aluminium alloy handles, fabricated type anodised 39 S&F vitreous china wash down water closet pan of pedestal pattern, white with P or S traps,including connecting to trap, seat cover and to flushing pipe etc complete all as specified. 40 S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engr-in-Charge 41 S & F10 litres PVC, Syphonic action type, Flushing cistern low level, white with inlet ball valve float chain and pull and bracketscomplete. 42 S&FPVC connection of 15 mm size withPTMT nuts of length 450 mm 43 S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls 44 S&F PVC (SWR) junction single, (single T) equal or unequal with access door110mm dia. 45 S&F PVC (SWR) bends any radius, bend 110mm dia. 46 S&F PVC (SWR) vent cowl 110mm dia 47 S&F PVC (SWR) WC connector 110mm dia lip ring. 48 S&F75 mm diaPVC (SWR) floor trap, plain with grating including jointing with solvent cement. 49 S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints fixed to walls. 50 S&F PVC (SWR) bends any radius with access door, 75mm dia. 51 S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings forwater supply pipes fixed to walls . 52 S&F 20 mm bore galvanised steel tubes medium grade with all fittings for water supply pipes fixed to walls. 53 S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. 54 S&F 15mm bore angle stop valves, fancy type chromium plated, screwed down, high pressure,screwed both ends for iron pipe or for unions & fixed. 55 S&F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cmlong between fllanges. 56 S&F in repairs 600mm x450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board fixed t wooden plugs with chromium plated brass screws and cup washers all as specified and directed 57 S&F vitreous china wash hand basin white flat back of size 550mmx400 mm includingcutting forand pinning in ends of brackets or errecting stand but exclusive of fixing ofwaste pipeand CI bracketscomplete all as specified and directed. 58 S&F 32 mm bore Low density poly ethylenepipes of pressure rating 6kgf/cm2fixed complete to walls,ceiling or in floors etc. 59 S&F 15 mm bore chromium plated fancy type pillar tap cast copper alloy with capstan heads, screwed down high pressure,with or without leterredHot ot Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed. 60 S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. 61 M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. 62 S&F 30 mm thick 2nd class hardwood glazed and skeleton shutters,open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securingglass etc ; sizes of members of shutters as specified in SSR Part-I, section-8, clause 8.24(a). 63 S & F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. conforming to e 410-W (GdeE- 250) quality A complete as specified. 64 S&F Rotational mounded polythene water storage tank of 1000 ltrs capacity,( Three layered, cylindrical, vertical with closed top) hoisted and fixed in position as specified in SSR Pt-I. 65 S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipes of 20 mm dia or brass ferrule and fixed, all as directed. 66 S&F Gun metal globe or gate valve with Iron wheel head, screwed both ends for 20 mm dia of pipe and fixed. 67 M&L for re-inforced cement concrete Nominal Mix 1:2:4 type B-1 (20mm graded aggregate) as in slab supported on walls, beams and columns etc complete. 68 M&L for MS TMT bars10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. 69 M&L for Form work to soffits of suspended slabs such as roof slab. Floor slab, landings and similar work n.exc 200 mm thick for rough finish flat surface of concrete. 70 M&L for Form work to edges of concrete flat, tread, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n.exc 10 cm wide for rough finish surfaces of concrete. 71 M&L for construction of 1.20 m dia x 3.00 m deep soakage well, excavation in hard/dense soil foundation PCC 1:3:6 ,wells of honey combed stone masonry wall, including intercepting chamber, screen chamber, RCC cover slab, filling with brick bats etc complete all as specified. 72 Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 150mm on after they are laid and tested complete all as specified and directed.. 73 Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 100mm on after they are laid and tested complete all as specified and directed.. 74 Material and labour for PVC (SWR) pipes 110mm dia single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 75 Material and labour for PVC (SWR) pipes 75mm dia single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. 76 M&L for point wiring with 1.5 sqmm(nominal area),two run ofsingle core PVCinsulated unsheathed,1100 volts grade,multi stranded copper conductor ,in and including PVC casing capping of adequate size with all fittings and acessories including PVC board with top cover housing/mounting brackets switches,sockets etc,including PVC insulated unsheathed single core multi stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch complete all as specified and directed. 77 All as per item ser No 76 here in beforebut for 3 pin 15 Amps socket outlet independent board drawn from DB and including PVC insulated multi stranded copper conductor 2.5 sqmm 1100 volts grade and wire earth continuity wire 2.5 sqmm PVC insulated copper wire (Green) including PVC casing and capping complete all as specified and as directed. 78 All as per item no 76 here in before One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. 79 All as per item No 76 here in before One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. 80 S&F Socket outlet 2 in 1, 3 pin, 5amp flush type 81 Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. 82 Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. 83 Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 04 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. 84 S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 Vcomplete all as specified and directed. 85 S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 Vcomplete all as specified and directed. 86 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm 87 Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified & directed. 88 Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. 89 S&Fof 1100 Volts grade heavy duty ISI marked cable PVC insulatedmulti stranded aluminium conductor one twin core cable flat or circular of size 16 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections , ofsize 10 Smm 2 core. 90 S&F for switch socket combination multiporpose 15 A flush type,5 in 1,240 volts all as specified and directed. 91 S&F switch socket combination 2 in 1, 3 pin, 6 Amp piano flush type (ISI marked),240 Volts including taking down unserviceable one complete all as specified & directed. 92 Supply and fixing LED Building securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete 93 S&F sheet metal enclosure for DBs SPN 8 way,with 200 amp rated bus bar Double door complete all as specified and directed. . 94 Supplying and fixing 1100 volt grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular multistranded 6 sqmm complete all as specified and directed