}

Tender For Maintenance And Repairs To Capacitor Panels Renewal Of Earthling System Other Allied Works (Tech And Domestic), coimbatore-Tamil Nadu

Military Engineer Services has published Tender For Maintenance And Repairs To Capacitor Panels Renewal Of Earthling System Other Allied Works (Tech And Domestic). Submission Date for this Tender is 29-08-2025. Electrical Panel Tenders in coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

50598745
Tender For Maintenance And Repairs To Capacitor Panels Renewal Of Earthling System Other Allied Works (Tech And Domestic)
Tender
Indian
Tamil Nadu
Coimbatore
29-08-2025

Tender Details

Tender For Maintenance And Repairs To Capacitor Panels Renewal Of Earthling System Other Allied Works (Tech And Domestic); 1 M&L for repair/servicing of capacitor panel 25 KVAR/30 KVAR/50 KVAR and carry out repairs such as dismantling of power contactros, auxillary contactors, CT Coil, checking the HRC fuse and replacement if any damaged, checking the control wiring and refixing all the components after proper servicing all as specified and as directed Note: Spare parts any required will be measured separately) 2 Supply only 5 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand 3 Supply only 10 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand 4 Supply only 15 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand 5 Supply only 33.3 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand 6 Supply only 40 KVAr capacitor duty contactors with built in surge suppressor and NO/NC . Make : L&T, Havells, Schneider, Legrand Note -Sl NO 2 to 5 The contactor frame size suitzble to mount existing capaciter panel 7 Supply only 20 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection complete.Make : L&T, HPL, Havells, Schneider, C&S 8 Supply only 15 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 9 Supply only 10 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 10 Supply only 7.5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 11 Supply only 5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 12 Supply only 4 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 13 Supply only 3 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 14 Supply only 2 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S 15 M&L for servicing of LT Panel board double door with canopy by cleaning with blower/replacement of lugs if any, replacemenmt of burned out copper wiring if any,cleaning and tightening of MCCB terminal connections, rectifying the loose connections, repairing of door locking arrangement including hinges or welding where required including marking the incomming/outgoing feeder name with label marker machine all as specified and as directed. 16 Supply and fixMCCB four pole 160A, 36 KA, 415 V, adjustable type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder 17 Supply and fixMCCB four pole 200A, 36 KA, 415 V, adjustable type suitable to existing frame with spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siemens/Indo asian/Havells /Schnieder 18 Supply and fixMCCB four pole 250A 36 KA 415 V, adjustable type suitable to existing framewith spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder 19 Supply and fixMCCB 3 pole 25-100 Amps, 16 KA, 415 V, fixed type suitable to existing framewith spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder 20 Supply and fix 415 V 10 KA C Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCBs all as directed. Make: C&S/ Siemens/Indo asian/Havells/Schnieder 21 All as per Item No 20 here-in-before but TPN 16 to 32 Amp capacity 22 All as per Item No 20 here-in-before but TPN 40 to 100 Amp capacity 23 Supply fix 415 V 10 KA B Curve miniature circuit breaker (MCB) of TP 25 to 63 Amp and current carrying capacity in the DB/LT Panel complete with connection testing and commissioning including taking down unserviceable MCBs all as directed.Make: C&S/ Siemens/Indo asian/Havells/Schnieder 24 All as per Item No 23 here-in-before but TPN/FP 16 to 32 Amp capacity 25 All as per Item No 23 here-in-before but TPN 40 to 100 Amp capacity 26 Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth or lengthwith cleaning, preparation of old painted surfaces and two coat of aluminium paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays poles etc all as specified and as directed. 27 Material and labour for painting of steel/iron surfaces of any description over 10 cm in width or girth with cleaning, preparation of old painted surfaces and two coat of Synthetic enamel paint of Gates and open palisade fencing, chain link fincing including standards. braces, rails. stays etc all as specified and as directed. 28 S&F in replacement of panel mounted LED phase indication lamp (Red,yellow,Blue ,Green colour) operating voltage 220 to 240 voltssuitable for fixing in the LT panel all as specified and as directed. Make L&T/AE/Simens or equivalent 29 Supply and fix in repair digital type voltage & amp meter 415 Volts, 3 Phase including connection, seting a ammeter asper exsisting CT ration and taking down unserviceable meter all as directed. MakeL&T, Havells, Sicco, AE, Elmeasure 30 Supply, Installing, testing and commissioning, CPRI approved outdoor cubial type LT feeder pillar box suitable for 415V, 3 Phase, 4 wire, 50 Hz, AC supply system fabricated from CRCA steel quality Atotally enclosed, dust, weather & vermin proof, front & back openable, double door system lockable / openable by keys from both sides having pattern fancy locks stainless steel in opening handle with louvers & air vent gasket for natural flow of air, the bottom of the outer shell contains a detacheable plate having provision for entry of adequate size with glands, 3.0 mm thick for outer shell and 2 mm thick for inner shell having TPN aluminium busbars of rating 1.5 times that of incoming MCCB supported on SMC insulators with short circuit withstand capacity 35 MVA for 1 second, bottom C type base channel of MS section not less than 100 mm, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 nos earth stud, solid bus bar connections from main bus bar to switchgears with required size and contrrol wiring with minimum 1.5 Sqmm FRLS insulated copper conductor wire, cable alleys, cable gland plates for Indicating lamp LED type, CT, selector switch,multifuction digital energy meter. The energy meter havingto measure voltage, current, PF KWH, KVAH, KVARH (Make - Secure / L&T / C&S / Schneider / Legrand), general construction confirming to IS : 8623 / 93 and mounted on suitable PCC foundation with followiing detailed specifications & controls and taking down the old panel board including disconnecting/reconnecting of all incoming and outgoing cable with new cable glande :- (Make - CPRI approved/certified manufacture)(a) The size of panel isnot less than 1.10 x1.10 x0.45 Mtr outdoor type having accomdoate 01 (one) Nos Incoming MCCB, 01 Nos change over and 04 (four) Nos MCCB outgoings.& 4 pole MCB,s outgoings four Nos separately Note : (i) The height of panel should be 0.45 to0.60 mtr from ground level with PCC foundation the cost of PCC foundation included in quated rate.(ii)Each MCCBs having seperate enclosures, marking with feeder name(iii) Switch gears (MCCB,MCB,ACB, Changeover, timer switch, contactor) will be measure and paid seperately under relevent items .(iv) The minimu height of PCC is 30 CM andratio of PCC 1:3:6 (v) Earth work excavation, returing filling, removel for panel erection and cabling connection included in quated rate 31 Supply and fixing 200 Amp, 4 Pole, 415 Volts, 50 Hz open executions on load mannual change over switch conforms to IEC-609473 with all accessories required for fixing in existing LT panel board complete. 32 Supply and fix APFC controller eight stage contactor switching three phase current and volatage measurment, auto/manual mode selection, individual PF setting system operating volatge 144 to 440 volts suitable to exsisting APFC panel including taking down unsderviceable controller all as directed Make - L&T, Havells, Elmeasure, AE 33 Supply, layig, connecting, testing and commissioning of 120 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Make: Havells/Polycab/Finolex/ Paragon/Gloster/Nicco 34 All as per Item No 33 here - in - before but 95 Sqmm 3.5 core complete. 35 All as per Item No 33 here - in - before but 70 Sqmm 3.5 core complete. 36 Supply and lay reinforced precost concrete cable cover class LV type 1 flat size 250 x 180x 40 mm all as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail