Construction Of Sanitary Complex At Office Building And Nulm Shelter In Velankannitown Panchayat Nagapattinam District , Earth Work Excavation For Foundation In Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales, Murram, Gravel, Stoney Earth And Earth Mixed With Small Size Boulders, Sand, Silt Or Other Loose Soil And To Full Depth As May Be Directed Except In Hardrock Reqiring Blasting Inclusive Of Shoring Shuttering And Bailing Out Water Wherever Necessary Refilling The Sides Of Foundation With Excavated Soil Other Than Sand In Layers Of 15Cm Thick Well Rammed And Completed Depositing The Surplus Excavated Soil With In The Compound In Places Shown By The Departmental Officrs With Initial Lead And Lifts And Cleaning, Levelling, The Site Etc., Complete As Per Ss 20B For Foundation , Cement Concrete 1:4:8 (One Cement, Four Fine Aggregate And Eight Course Aggregate) Mix Using 40Mm Hbg Iss Metal From Approved Quarry Including Cost And Conveyance Of All Materials To Site And Labour Charges, Including Dewatering If Found Necessary And Laid In Layers Of Not More Than 15Cm Thick And Compacted Etc., Complete Complying With Standard Specifications As Directed By The Departmental Officers , Centering For Soffits Of Rcc And Pcc Slabs Of Plane Surface Like Lintels, Beams, Etc., Including Strutting 3M High Using Mild Steel Sheets Of Size 90Cm X 60Cm X And Bg 10 Stiffened With Ms Angles Of Size 25Mm X 25Mm X 3Mm Laid Over Silver Oak Joists Of Size 10Cm X 6.5 Cm Spaced At About 90 Cm C/C And Supported By Consurina Props Of 10 Cm To 13Cm Dia Spaced Of 75Cm C/C Complying With Standard Specifications And As Directed By The Departmentsl Officers Etc., Complete , Grade Beam , Column , Plain Surface , Supply And Fabrication Of Steel And Placing In Position Ms/Ribbed Tor Steel Grills For Rcc Works As Per Design Given Including Cost Of Steel And Gi Binding Wire In All Floors Etc., Complete Complying With Standard Specificationsas Directed By The Departmentsl Officers , Providing And Laying In Position Standardised Concrete Mix M-20 Grade In Accordance With Is 456 - 2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Contenet Of 325Kg/ Cum And Maximum Water Cement Ratio Of 0.55 Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is 9103 To Accelerate, Related Setting Of Concrete, Improve Workability Without Imparing Strength And Durability With About (5.0Cum), 7730Kg Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cum), 5156Kg Of 10 - 12Mm Machine Crushed Stone Jelly And With About (4.79Cum) 7670 Kg Of Crushed Stone Sand (M- Sand), But Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabs Wherever Necessary Without Claiming Extra Cost Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers - , Foundation & Basement , Ground Floor , Brick Work With C.M. 1:5 (One Cement And Five Sand) Mix Using Ii Clsss Country Bricks Of Size 8 3/4 X 4 1/4 X 2 1/4Including Cost And Conveycnce Of All Materials And Labour Charges For Neat Finishing And Curing Etc., Complete Complying With Standard Specificationsas Directed By The Departmental Officers. (P & D) Data - 22 , Collection Supply And Filling Of Well Gravelin Layer Not More Than 15 Cm Thick Including Watering With All Layers And Consolidation Complying With Standard Specifications Including Cost And Conveyance Of Sand At Site And Labour Chrages And All Other Incidental Charges Etc., Complete As Per Standard Specifications , Special Ceiling Plastering With C.M.1:3 (One Part Of Cement And Three Part Of Sand) Mix Using 10 Mm Thick Including Cost And Conveyance Of All Materials And Labour Charges Ete., Complete Complying With Standard Specifications As Directed By The Departmental Officers , Plastering With C.M.1:5 (One Part Of Cement And Five Part Of Sand) Mix Using 12 Mm Thick Including Cost And Conveyance Of All Materials And Labour Charges Ete., Complete Complying With Standard Specifications As Directed By The Departmental Officers , Paving The Floor With Vitrified Marbonite Tiles Of Approved Quality And Colour Of Size 610X610x10mm Thick Of Approved Make, Quality And Colour In All Floors Over A Base Layer Of Cement Mortar 1:3(One Cement Three Sand) 20Mm Thick And Laid Straight Alignment And Pointed Neatly With Colour Cement At The Rate Of 0.40Kg/M2 Laid Without Any Air Gap In The Tiles Neatly And Fixing In Position As Per Standard Specifications And As Directed By The Departmental Officer.The Colour & Quality Of Tiles Should Be Got Approved By Municipal Engineer Before Use On Work , Dadooing Walls With Ceramic Tiles Of Sizes 300Mm X 450Mm X 8Mm Size Of Approved Make And Quality And Colour Set In Cement Mortar 1:2 (One Part Of Cement And Two Part Of Plastering Sand (P- Sand)) Over 10 Mm Base Layer Plastering And Pointing With White Cement Neatly As Directed. , Painting Two Coats For Exterior Surface With Approved Exterior Plastic Emulsion Paint Approved Quality And Colour Over A Priming Coat, Including Thorough Scrapping, Clean Removal Of Dirt, Etc Complete And Including Necessary Plaster Of Paris, Putty, Wherever Required Etc, Complete As Per Standard Specification. , Providing Upvc (Un-Plasticized Polyvinyl Chloride) Door: Providing And Fixing Casement Doors Fabricated From Unplasticized Polyvinyl Chloride (Upvc) Sections. Profiles: The Profiles Should Be Three Chamber System Which Provides High Insulation Properties With Outer Frame 60Mm X 55Mm With An Outer Wall Thickness Of 2.4Mm. The Window Unit Should Be Designed With All Corner Joints Mitred And Fusion Welded. Windows Should Be Steel Reinforced With 25 X 24 X 25Mm Steel Reinforcement With A Thickness Of 1Mm To Have Dimensional Stability. The Sash Should Be Of 60 X 102Mm. The Mullion Should Be Of 60 X 74Mm. The Profiles Should Have Co-Extruded Seals. Hardware: All The Hardware Like Friction Stays, Handles Should Be Screwed With Self Tapping Screws. The Handles, Locks Should Be Designed So That They Cannot Be Releasedfrom Outside. Glazing: The Window System Should Be Glazed With 5Mm Plain Float Glass / 6Mm Bison Lam Installation: The Profiles Should Be Cut To Length And Welded 45 Degrees. The Window Should Be Designed Such That The Water Drainage Does Not Pass Through The Reinforcement Chamber. The Window System Should Be Fixed Directly To The Plastered Brick Wall Using Self Expanding Nylon Plug And Driving Ms Electroplated Screws Into Plug. , Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators Of From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Size Of 60 X 78Mm Both Profiles Are Reinforced With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profile Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With All Over The Edges Of Frame And Shutter. The Corners And Joints Should Be Welded And Cleaned. Radiations Pin Headed Glass 4Mm Thick Should Be Provided In The Louvers. The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Ventilator Should Be Got Approved From The Executive Engineer Before Use On Work , Supplying And Fixing In Position Indian Water Closet Of Size 580 X 440Mm, White Glazed Earthen Ware Of Approved Quality With P Trap Or S Trap Confirming To Is:2556 -Part Xii With Sand Cushion And Forming Flooring Alround The Closet Using 40Mm Broken Brick Jelly In Lime Concrete1:2:5 ( One Part Of Lime, Two Parts Of Sand And Five Parts Of Brick Jelly) 100Mm Thick And Finishing The Top To Required Slope And Including Giving Necessary Connection To Cast Iron Soil Pipes/ Pvc Pipes By Dismandling Brick Masonry, Reinforced Cement Concrete Roof/Floor Slab And Making Good The Disturbed Portion To Original Condition Without Leakage Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. , Supplying And Fixing In Position Best Quality Approved Make White Glazed Earthenware Wash Hand Basin Of Size 550 X 400 Mm With A Pair Of Cast Iron Brackets, Including Cost Of 15Mm Diametre Brass Chromium Plated Piller Tape,32 Mm Diametre C.P. Waste Union, 32 Mm Diametre P.V.C. Waste Pipe With Rubber Plug And Chain, 15Mm Diametre G.M.Wheel Valve, 15Mm Dia Brass Nipple, 15Mm Dia Nylon Connections Etc., Including Fixing The Wash Hand Basin In The Wall In Position With A Pair Of C.I. Brackets With Teak Wood Plugs And Screws And Giving Necessary Water Supply Connection And Paintiung The Brackets With Two Coats Of Paint Over A Primimg Coat Of Anticorrosive Paint Including Testing For Leackage Etc., Complete Complying With Standard Specifications , Supply And Delivery And Fixing Of Hdpe Tank As Per Is 12701 / 1996 Including Loading, Unloading, Transportation And Labour Charges For Fixing Of The Gi Pipes And Specials For Pipe Connection Works Including Cutting, Threading And Fixing Charges Etc.,