| Sl. No. | Item Description |
| 1 | W.T.P -Design (hydraulic and structural ), construction, (including topographical survey, geotechnical investigation and other Surveys as required) for specified capacity of WTP based on 20 Hrs. operation including inlet chamber, aeration fountain / cascade, inlet channels ,chemical building ,including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby ,safety equipment’s &EOTcrane,pressureandleveltransmitterfor pumpingplant,turbidity, TDS, PHAnalyzer,chlorineanalyzer,ROFTandLOHTforfilter house,flowtransmitterultrasonic/electromagneticatinletandoutletandFilter backwashwithentirepipingsystem , sludge handling unit and recycling of collected water from sludge , etc. complete to achieve desired perameters of clear wateras specified in tender document andin accordace letest C.P.H.E.E.O.Manual,/ltest guidline/ I.S. Codes/Govtt. Orders . All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building,Sub station building (L.T./H.T. Room), Platform for Transformer,Meter Room ,chlorine Room,Staff Quarter (Type III-one Number), sanitary block with necessary water supply and drainage arrangement, campus roads (Interlocking Road/C.C.Road), landscaping( earth filling up to 115.00level including levelling and dressing of Campus )and other campus development works with rain water harvesting and garden, etc. all required works complete as per the direction of Engineer-in-Charge in Pile Foundation .The WTP shall be fully automatic prefrablybased onRapid sand gravity filter or any proven technologysuitable to treat Raw water from yamuna river throug out the year , PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring systemincluding Soil testing, Design ,S/o all labour ,material T&P etc. required for proper completion of the work as per letest IS Codes ,manuals ,instruction of engineer in charge and tender document. |
| 2 | INTAKE WELL- Supply of all materials, labour, T&P etc.as requiredforDesign and construction of Intake- well - cum - pump house of 9.0 m. internal dia. The intake well upto floor level shallbe firmly based on suitable foundation made with well sinking tecgnology including construction of coffer damand Annular raft/ well foundation , including construction of 1.20 m. wide R.C.C. balcony at plinth level, construction of Pump House made of brick masonry, duly embraced within R.C.C. column, and fitting of doors and windows, making opening arrangement at floor level of pump house (9.00 m. dia and 6 m. height)and construction of 1.20 m. wide R.C.C. balcony at Pump house floor levelincluding S.S. Rolling Shutter, steel cage hinged with locking arrangement, duly supported on steel girder. Plateform for transformer ,meter room andSubstation Building (HT pannel room,LT pannel room ) Ventilator arrangement along with fixing of required size dia. DID/F pipesand Sluice Valves- 3 Noat inlet etc. as per site requirement or as per the design. The work also includes steelrailing(grad 304 ) in three rows on both sides of pump house balcony and fixing of 0.5m. wide M.S. ladder made of 50 x 50x 6mm. angle iron ladder from floor of pump house to floor of intake well, duly supported on R.C.C.landing at suitable interval. The ladder shall run spirally inside the intake well and each landing shall be supported on R.C.C. M.S. channelpost, spaced not more than 1.5 m. interval including Construction of R.C.C. foundation block as required also include provision for dismantling and reinstatement of stone pitching,removal earth of Coffer dam to maintain flow through-out the year ,Approch roadup to Approch bridge etc up to completion of work as per insrtuction of engineer in charge and tender document . |
| 3 | The floor of pump house & balcony shall be of Kota Stone etc. complete. Frames for doors / Shutter shall be made of 50x50x5 mm. M.S. angle iron and ionized and shall be partly panelled and glazed, made of suitable steel sections, conforming to relevant BIS. The work also includes painting of all concrete surfaces with three coats of approved paint and painting of pipes, doors, windows with anticorrosive paints including design of intake well, foot bridge, pump house etc. considering seismic and other forces as per relevant BIS requirements. |
| 4 | Design and construction of 4.0 mts. wide R.C.C Foot bridge from Intake well to bank of river for length of 350 mtsminimum height of foot over bridgeslab should be equal to level of floor level of Pump House. pier of bridge in well shinking foundation minimum two Beam below deck slab with bearing support. Provision for padestal construction to rising main pipe fixing with anchor Clamping ,casing pipe for electric cables . Also including Supply& fixing ofstainless steel (gread 304) railing both sides of foot bridge , floor shall be plain chequered tiles, Statinless steel gate at entry gate of Approch bridge with locking arrangmentsup to completion of work as per insrtuction of engineer in charge and tender document . |
| 5 | Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 and IS 11682 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit asI.S. 456.Minimum depth of founditation below original ground level will be 2.0 M and in pile Foundation .Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope domto bootom dome). |
| 6 | 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.including soil testing from govt institute as per tender document andrelevent IS codes. |
| 7 | Zone -1 1300KL/22M |
| 8 | Zone -21100KL/25M |
| 9 | Zone -3 2400KL/22M |
| 10 | Zone -4 300KL/25M |
| 11 | CONSTRUCTION OF R.C.C CLEAR WATER RESERVIOUR (C.W.R) CUM PUMP HOUSE OF VARIOUS AT DIFFERENT SITE Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with HT, L.T and meter room, GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank and inside the tank, locking device, ventilator, supply and fixing digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.including soil testing from govt institute as per tender document andrelevent IS codes. |
| 12 | 1200kl (MCWR) |
| 13 | Demolition of R.C.C Over Head Tank (OHT)Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency and other defung buildings like staff quarters, damaged pump house including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity of E.S.R. upto 2 lakh litres and staging upto 12 M heightZone -1 500KL/12M |
| 14 | Zone -2 -400KL/12M |
| 15 | Raw Water Rising Mains From Intake To WTPExcavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters. |
| 16 | 500 mm DI K-7(yamuna river to WTP) |
| 17 | Supply of ISI mark DI K-7 S&S pipes (push on joints) with supply of allDI specials of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete |
| 18 | 500 mm DI K-7(yamuna river to WTP) |
| 19 | Lowering, laying and jointing with ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position also fixing of pipe on foot over bridge, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. |
| 20 | 500 mm DI K-7(yamuna river to WTP) |
| 21 | Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. |
| 22 | Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm |
| 23 | -Air valves as per IS 14845 : 2000-100 mm |
| 24 | Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. |
| 25 | Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm |
| 26 | Kinetic Double Air Valves-Air valves as per IS 14845 : 2000-100 mm |
| 27 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
| 28 | Providing reinforcementincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar) |
| 29 | Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. |
| 30 | Sluice valve Chamber 500mm |
| 31 | Air valve Chambers -Air valves as per IS 14845 : 2000-100 mm |
| 32 | Rising MainsSupply of ISI mark DI K-7/K-9 S&S pipes (push on joints) of following with D.I. specials and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete |
| 33 | 125 D.I K-9 |
| 34 | 200 D.I K-9 |
| 35 | 350 D.I K-9 |
| 36 | 400 D.I K-9 |
| 37 | Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth |
| 38 | Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. |
| 39 | 125 D.I K-9 |
| 40 | 200 D.I K-9 |
| 41 | 350 D.I K-9 |
| 42 | 400 D.I K-9 |
| 43 | Supply of following type ofDI valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. completeDouble flanged Ductile Iron Sluice valves as per IS 14840 : 2000./Air valves as per IS 14845 : 2000 including Sluice valve of Isolation |
| 44 | 125 mm D.I D.F. |
| 45 | 200 mm D.I D.F. |
| 46 | 350mm D.I D.F. |
| 47 | 400 mm D.I D.F. |
| 48 | 25 mm D.I D.F. |
| 49 | 50 mm D.I D.F. |
| 50 | 80 mm D.I D.F. |
| 51 | Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 /Air valves as per IS 14845 : 2000 |
| 52 | 125 mm D.I D.F. |
| 53 | 200 mm D.I D.F. |
| 54 | 350mm D.I D.F. |
| 55 | 400 mm D.I D.F. |
| 56 | 25 mm D.I D.F. |
| 57 | 50 mm D.I D.F. |
| 58 | 80 mm D.I D.F. |
| 59 | Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. |
| 60 | Sluice valve Chamber (MASONRY TYPE) |
| 61 | Air Valve Chamber |
| 62 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
| 63 | MS work in plain RCC incluiding bending supply wastage overlaping etc complete |
| 64 | Provision for crossing of Nalas/culvert for laying of pipe line usingsuitable dia. and length 0.60 m more than the outer width of nala, labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.(up to 3.50m wide) |
| 65 | NHAI crossing by trenchless technologyProviding and laying of 700 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 400 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply distribution. |
| 66 | Railway crossing by trenchless technologyProviding and laying of 250 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 125 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply. |
| 67 | Dismantling of following type of road surfaces for laying of pipe line n work including sorting out of serviceable materials and disposal of unserviceable materials. |
| 68 | Bituminious Road |
| 69 | Cement Concrete Road |
| 70 | Re-instatement of following type of road surfaces after laying of pipe linework including supply of all materials, labour, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. |
| 71 | Bituminious Road |
| 72 | Cement Concrete Road |
| 73 | Distribution Network .Supply of ISI Marked or its relevant code HDPE Pipes and Electrofusion specialsof follwing sizes (Dia in mm) with jointing materials, specials of sizes required during constructionas per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer |
| 74 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
| 75 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
| 76 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
| 77 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
| 78 | Supply of ISI Marked or its relevant code DI K-7 Pipes and Specials of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer |
| 79 | D.I. K-7/ 200 mm |
| 80 | D.I. K-7/ 250 mm |
| 81 | D.I. K-7/ 300 mm |
| 82 | D.I. K-7/ 350 mm |
| 83 | D.I. K-7/ 400 mm |
| 84 | D.I. K-7/ 450 mm |
| 85 | Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. /Air Valve as per as I.S : 14845D.I. D/F Sluice valve/ Scour valve |
| 86 | 25 mm. dia DI D/F |
| 87 | 50 mm. dia DI D/F |
| 88 | 100 mm. dia DI D/F |
| 89 | 150 mm. dia DI D/F |
| 90 | 200 mm. dia DI D/F |
| 91 | 250 mm. dia DI D/F |
| 92 | 350mm. dia DI D/F |
| 93 | Fire hydrant (80 mm dia.) |
| 94 | Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. |
| 95 | Cartage fromstore to site of work for following size (dia in mm)HDPE pipes andElecrofusion Specialsand lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) |
| 96 | HDPE PIPE GRADE PE 100/ PN 6- 90 mm |
| 97 | HDPE PIPE GRADE PE 100/ PN 6- 110 mm |
| 98 | HDPE PIPE GRADE PE 100/ PN 6- 140 mm |
| 99 | HDPE PIPE GRADE PE 100/ PN 6- 160 mm |
| 100 | Cartage of DI K-7 pipes and specials of following size (dia in mm) , lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. |
| 101 | D.I. K-7/ 200 mm |
| 102 | D.I. K-7/ 250 mm |
| 103 | D.I. K-7/ 300 mm |
| 104 | D.I. K-7/ 350 mm |
| 105 | D.I. K-7/ 400 mm |
| 106 | D.I. K-7/ 450 mm |
| 107 | Carting of following size of Sluice Valves/ Scour Valves Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete.D.I. D/F Sluice valve/ Scour valve/ air valve |
| 108 | 25mm dia |
| 109 | 50 mm dia |
| 110 | 100 mm dia. |
| 111 | 150 mm dia. |
| 112 | 200 mm dia. |
| 113 | 250 mm dia. |
| 114 | 350 mm dia. |
| 115 | Fire hydrant (80 mm dia.) |
| 116 | R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. |
| 117 | Thrust Block |
| 118 | Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . |
| 119 | Sluice valve chamber |
| 120 | Scour Valve Chamber |
| 121 | Air Valve chamber |
| 122 | Fire hydrant chamber |
| 123 | Flow Meter chamber |
| 124 | Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. |
| 125 | For crossing ofnalla/culvert upto 3.5 m wide(90mm dia to 110mm dia ) |
| 126 | For crossing ofRoad upto3.5 m wide(90mm to 110mm ) |
| 127 | For crossing ofRoad upto7.0. m wide(90mm to 110mm) |
| 128 | Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work |
| 129 | Interlocking tile |
| 130 | C.C Road |
| 131 | Bituminous Road |
| 132 | B.O.E Road |
| 133 | Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour T&P etc. required for proper completion of work. |
| 134 | Interlocking tile |
| 135 | C.C Road |
| 136 | Bitumenous Road |
| 137 | B.O.E Road |
| 138 | NEW HOUSE CONNECTIONMaking House Connectionwith Distribution main with elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe , including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches , fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. |
| 139 | In C.C. Roads |
| 140 | For 90 mm to 110mm dia |
| 141 | For 125 mm to 160 mm dia |
| 142 | For 200 mm to 250 mm dia |
| 143 | For 300 mm to 350mm dia |
| 144 | For 400 mm to 500mm dia |
| 145 | In Bitumenous Roads |
| 146 | For 90 mm to 110mm dia |
| 147 | For 125 mm to 160 mm dia |
| 148 | For 200 mm to 250 mm dia |
| 149 | For 300 mm to 350mm dia |
| 150 | For 400 mm to 500mm dia |
| 151 | In B.O.E. Roads |
| 152 | For 90 mm to 110mm dia |
| 153 | For 125 mm to 160 mm dia |
| 154 | For 200 mm to 250 mm dia |
| 155 | In C.C. Interlocking Tiles Roads |
| 156 | For 90 mm to 110mm dia |
| 157 | For 125 mm to 160 mm dia |
| 158 | For 200 mm to 250 mm dia |
| 159 | For 300 mm to 350mm dia |
| 160 | For 400 mm to 500mm dia |
| 161 | In Kacha Roads |
| 162 | For 90 mm to 110mm dia |
| 163 | For 125 mm to 160 mm dia |
| 164 | For 200 mm to 250 mm dia |
| 165 | For 300 mm to 350mm dia |
| 166 | SHIFTING OF HOUSE CONNECTIONMaking House Connection with Distribution mainwith elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe ,including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches ,fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. |
| 167 | In C.C. Roads |
| 168 | For 90 mm to 110mm dia |
| 169 | For 125 mm to 160 mm dia |
| 170 | For 200 mm to 250 mm dia |
| 171 | For 300 mm to 350mm dia |
| 172 | For 400 mm to 500mm dia |
| 173 | In Bitumenous Roads |
| 174 | For 90 mm to 110mm dia |
| 175 | For 125 mm to 160 mm dia |
| 176 | For 200 mm to 250 mm dia |
| 177 | For 300 mm to 350mm dia |
| 178 | For 400 mm to 500mm dia |
| 179 | In B.O.E. Roads |
| 180 | For 90 mm to 110mm dia |
| 181 | For 125 mm to 160 mm dia |
| 182 | For 200 mm to 250 mm dia |
| 183 | In C.C. Interlocking Tiles Roads |
| 184 | For 90 mm to 110mm dia |
| 185 | For 125 mm to 160 mm dia |
| 186 | For 200 mm to 250 mm dia |
| 187 | For 300 mm to 350mm dia |
| 188 | For 400 mm to 500mm dia |
| 189 | In Kacha Roads |
| 190 | For 90 mm to 110mm dia |
| 191 | For 125 mm to 160 mm dia |
| 192 | For 200 mm to 250 mm dia |
| 193 | For 300 mm to 350mm dia |
| 194 | Building worksSupply of all materials, labour, T& P, complete and construnction of a Half set of One No.Single Roomed staff quarters for Operator staff, pump operator, chaukidaar, pump attendent and other as per approved design in pile Foundation. |
| 195 | Zone-1 |
| 196 | Zone-2 |
| 197 | Zone-3 |
| 198 | Zone-4 |
| 199 | At wtp campus |
| 200 | Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation.For Construction of general resedential staff quarters(type-II) 1nos of 2 half set of area 57.70sqm. |
| 201 | Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation for Construction of following type of ancliary buildings Master Control Room(5x4.5x4m) |
| 202 | Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per Approved design in pile foundation. |
| 203 | Water Campus Zone 1 |
| 204 | Water Campus Zone 2 |
| 205 | Water Campus Zone 3 |
| 206 | Water Campus Zone 4 |
| 207 | AT wtp campus |
| 208 | Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. |
| 209 | Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc |
| 210 | Water Campus Zone 1 |
| 211 | Water Campus Zone 2 |
| 212 | Water Campus Zone 3 |
| 213 | Water Campus Zone 4 |
| 214 | Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete |
| 215 | Zone-1 |
| 216 | Zone-2 |
| 217 | Zone-3 |
| 218 | Zone-4 |
| 219 | Filling of earth of lower portion including levelling and dressing at water works |
| 220 | E&M works |
| 221 | RAW WATER PUMPING PLANT ATINTAKE WELL |
| 222 | Supply of Vertical type oil lubricated statically, dynamically, hydraulicallybalancedturbinepumpcapableofdischargingat980 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 980 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, oil tube and 24mtr/suitablelengthcolumnassembly,withverticalSolidshaft Squirrel cage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuousratedTEFCIP-55withClass\"F\"insulation,antirotation locking arrengementfor operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 6000 LPM / 35 Mtr. HEAD / 75 HP MOTOR (2w+1s) |
| 223 | MAIN PIPING AND VALVES :- |
| 224 | Supplyof250 mm dia DIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . |
| 225 | SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67 (IP-68 for field installation),protectionclasssuitableforinstallation inanypositionwithout lubrication, leakage or other operational difficulty with special grease filledgearboxandsuitableformanualoperationforemergency which will automatically dis-engage on restoration of power to motor andwith10wattsinglephasespaceheaterandcontinuouslocal mechanicalpositionindicatorandindividuallyreplaceablecounter gear assembly and with two torque and four limit switches with S.S. flapandoperatedwithgeardrivencamsandofrating250Volt,5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation sluice valve havingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI.Valvesare suitablefor hydrostatictestpressureof10Kg./Cm2forseatand15Kg./Cm2for body(PN-1.0)of following sizes |
| 226 | 250 mm dia size at Pump delivery |
| 227 | 350 mm dia size at common header |
| 228 | SupplyofDIDF manuallyoperatedsluicevalvehavingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass |
| 229 | Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -3 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -1 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot |
| 230 | SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size |
| 231 | Dismantling joint 200 mm dia size at pump delivery |
| 232 | Dismantling joint 350 mm dia size at common header |
| 233 | Suitable capacity heavy duty handoperatedoverheadTravelling(HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. |
| 234 | MOTOR CONTROL CENTER (MCC) PANEL :-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust andvermin proof IP-54 /IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 3 No, Digital Amperemeter0-1000A -3Nos,CTFormeterResinCastCL- 1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A |
| 235 | SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ampere meter, Voltmeter, indicating lamp6Nos,LEDON/OFFtypeandStart/Stoppushbuttonand InstrumentFuses,suitabletoSCADAoperationwithRS485Port rating capacity 75 HP / 55 KW |
| 236 | Supply & laying of 1.1KV grade XLPE insulated armured multi strand copperconductorcableof3Cx50sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I/ IS :7098 P-I) |
| 237 | Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm |
| 238 | Earthing with GI earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories, and providing masonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 :2018 |
| 239 | Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) |
| 240 | Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 |
| 241 | Supply of CE/UL Certified Surge protector for control panel |
| 242 | Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 400 Amp |
| 243 | S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact SolarLED Street Light- 60W/12V/27Ah with GI pole |
| 244 | Internal & External electrification of Pump house :- |
| 245 | Twin tube light covered LED 20 Watt |
| 246 | 450 mm dia exhaust fan |
| 247 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light |
| 248 | CompletewiringofPumphouse with1.5 Sqmm& 2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose |
| 249 | RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 250 | INSTRUMENTATIONWORKS AT INTAKE WELL |
| 251 | Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved makeoffollowing dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SS AISI 316L /Hastelloy C276/Tantalum,LiningMaterial:Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard&Rating:ANSI150,Coilhousing:SSAISI304/Carbon Steel/DieCastAluminium, withanticorrosivepaint &provide completelysealed(leakproof)constructionasperrequirement ‘of IEC60529,Accuracy:+0.5%M.V.-velocity0.3to10m/s, Transmitter/signaconvertor Enclosure :DieCast Aluminium, Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable(size - 350 mm dia at common header) |
| 252 | SupplyofCE/ULCertifiedpressuretransmitterCEmarkdwith following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 253 | Supply of CE/UL cirtified ofRadar level transmitter CE marked with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 254 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and PowerSupplywithanalogandDigitalParameterandfeaturesas specified tostoreandtransmitdataonGSMbackbone,RTU/PLC designedwithlogictotansferdataatmultiplestationsandalso compatible for satellite communication. |
| 255 | Control panel with IP 54 Protection, Industrial grade forall equipment and 24V and power supply |
| 256 | GSM/GPRS based wirelesscommunicationwith 4G modem for RTU/PLC Capable to transfer and gather data from remotesites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge |
| 257 | CE & UL Certified 10\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters |
| 258 | CE/UL Certified Intelligent energy meters |
| 259 | Complete cabling for instrumentation works with power cabeling to panel of automation |
| 260 | SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. |
| 261 | Installation, testing and comissioning of pumping plant & associated allequipmentsasperapproveddrawingshallbedonebybidder includingchequerredplateandpaintingofpumpingplant&main piping-valves. |
| 262 | Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works |
| 263 | CLEAR WATER PUMPING PLANT AT MCWR |
| 264 | SupplyofVerticaltypeselfwaterlubricatedstatically,dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm thefollowingdutyconditionasgivenbelowduetoallcauseswith surfacedischargeheadconfirmingtoIS:1710andasamendedason datewithaccessoriesasperIS5120/1977(Reconfirmed2011)andas amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260 with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer,Suctionbellmouth,strainer,oiltubeand05mtr/suitable lengthcolumnassembly,withverticalSolidshaft Squirrelcage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class \"F\" insulation, anti rotation locking arrengement for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 5300 LPM / 50 Mtr. HEAD / 100 HP MOTOR (2w+2s) |
| 265 | MAIN PIPING AND VALVES :- |
| 266 | SupplyofDIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing 250 mm |
| 267 | SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67(IP-68 for field installation),protectionclasssuitableforinstallationinanypositionwithout lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotorand with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADAoperation sluice valve having Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0)of following sizes :- |
| 268 | 250 mm dia size at Pump delivery |
| 269 | 350 mm dia size at common header |
| 270 | Supply of DIDFmanually operated sluice valve having body Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass |
| 271 | Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -4 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 4 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot |
| 272 | SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size |
| 273 | Dismantling joint 200 mm dia size at pump delivery |
| 274 | Dismantling joint 350 mm dia size at common header |
| 275 | 3 Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. |
| 276 | MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147,consideredEarthBus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCBmicroprocessor baseed(O/C,S/C) release - 1 No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital MultifunctionMeter-1No,DigitalVoltmeter0-500V-1No,Digital Amperemeter0-400A -3Nos,CTFormeterResinCastCL- 200A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, ControlMCBSP6A,10KA-3Nos,CTShortingTerminal-4Nos, Neutral Link - 1 No.OUTGOING SECTION250 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A |
| 277 | SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offeredforoperationinACthreePhase50Hz(+/-5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFFtypeandStart/StoppushbuttonandInstrumentFuses, suitable to SCADA operation with RS485 Port rating capacity 100 HP / 75 KW |
| 278 | Supply & laying of 1.1KV grade XLPE insulatedarmured multi strand copperconductorcableof3Cx95sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI marked as per IS:1554 P-I / IS:7098 P- I) |
| 279 | Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm |
| 280 | EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 |
| 281 | Supplyingandlaying50mmX12mmG.I.stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedone by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 282 | Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 |
| 283 | Internal & External electrification of Pump house :- |
| 284 | Twin tube light covered LED 20 Watt |
| 285 | 450 mm dia exhaust fan |
| 286 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light |
| 287 | Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose |
| 288 | Supply of CE/UL Certified Surge protector for control panel |
| 289 | RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 290 | INSTRUMENTATION WORKS |
| 291 | SupplyofCE/ULFullBoreElectromagneticFlowMeterofapproved makeoffollowingdiaandspecificationscomplete: Media: Water ( Chlorinated) , Pressure : up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, withanticorrosivepaint&providecompletely sealed (leakproof) construction as per requirement ‘of IEC 60529, Accuracy:+0.5%M.V.-velocity0.3to10m/s,Transmitter/signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP68forsensor(flowtube)andIP67fortransmitter/ convertor, including Surge Arrester, cable, of of following sizes :- |
| 292 | 350 mm dia. Size at common header of pumping plant |
| 293 | 350 mm dia. Size at OHT outlet of zone-1 |
| 294 | 350 mm dia. Size at OHT outlet of zone-2 |
| 295 | 450 mm dia. Size at OHT outlet of zone-3 |
| 296 | 200 mm dia. Size at OHT outlet of zone-4 |
| 297 | Supply of Electrically Motor operated actuator with positioning card and bracketforsluicevalvesuitableforSCADAoperationwithlimit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable forOHT outlet of following sizes |
| 298 | 350 mm dia. Size at OHT outlet of zone-1 |
| 299 | 350 mm dia. Size at OHT outlet of zone-2 |
| 300 | 450 mm dia. Size at OHT outlet of zone-3 |
| 301 | 200 mm dia. Size at OHT outlet of zone-4 |
| 302 | SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size |
| 303 | Dismantling joint 350 mm dia size at OHT outlet of zone-1 |
| 304 | Dismantling joint 350 mm dia size OHT outlet of zone-2 |
| 305 | Dismantling joint 450 mm dia size at OHT outlet of zone-3 |
| 306 | Dismantling joint 200 mm dia size at OHT outlet of zone-4 |
| 307 | Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 |
| 308 | Supply of CE/UL cirtified ofRadarlevel transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 |
| 309 | CE & UL Certified PLC/ RTU with redundent CPU & power supply in IP 54 enclosure suitable to communicate with GSMBasedmodemwith redundentCPU andPower Supply with analog and Digital Parameter and features as specified for each ZPSto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for CWR. |
| 310 | Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply |
| 311 | GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for CWR & OHT |
| 312 | CE & UL Certified 10\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. |
| 313 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligentGSMBasedmodemunit with CPU andPower Supply with analog and Digital Parameter and features as specifiedto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for OHT |
| 314 | Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply |
| 315 | GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for OHT |
| 316 | CE/UL Certified Intelligent energy meters |
| 317 | Complete cabling of instrumentation equipments with power supply of panels for CWR & OHT |
| 318 | SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. |
| 319 | Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. |
| 320 | Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works |
| 321 | 11/0.44KV SUB STATION AT INTAKE WELL |
| 322 | Supply of star rated Copper wound distribution Transformer ( All the distributiontransformermustbestarratedaspernotificationof (BEE)ministryofpower,GoverenmentofIndia)offollowingrating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cablebox<cableboxes,Off-LTC(+7.5%to-15%@2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, OTI & WTI, marshallingbox,firstfillingoftransformeroilasperIS:335-1953, Epoxy based paint.Rating capacity - 200 KVA (1w+1s) |
| 323 | Supply of SCADA compatible with RS 485 port , 11KV, 800 A, 25kA / 1 Sec, VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steelWith Copper Bus bar, Ammeter,Voltmeter,PFMeter,KWHMeter,MDIMeter,Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps, S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformerprotection(Highoiltemperature,Buchholzprotection, highwindingtemperature,powerpack2x12V,etccompleteinall respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB. |
| 324 | Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 3 No, 3 Phase Digital Multifunction Meter- 1 No, Digital Voltmeter 0- 500V- 1 No, Digital Ampere meter 0-1000 A- 3 Nos, CT For meter Resin Cast CL-1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400A,50KA,TPN,ACB, EDO microprocessor based(O/C,S/C) RELEASE - 1 No, 63A TPN MCCB 32KA- 2 Nos. Terminal 63A. |
| 325 | Supply and laying of 11/12KV grade XLPE insulated H.T. armoured cable as per IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCLmetering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size |
| 326 | Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. |
| 327 | SupplyofH.T.Cableendterminationheatshrinkabletypeoutdoor joint kit 120 sq.mm. |
| 328 | Supply & laying of L.T. XLPE insulatedarmoured aluminium conductor cableof1.1KVgradeMaterial:-H4-Gradealuminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel and main LT panel to MCC panel of 3.5C x 300 Sq.mm. |
| 329 | Earthing with copper earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 |
| 330 | Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) |
| 331 | Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 |
| 332 | RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 333 | NOC from electrical safety Dept. Govt. of UP |
| 334 | Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. |
| 335 | Internal & External electrification of HT & LT panel room :- |
| 336 | Twin tube light covered LED 20 Watt |
| 337 | 450 mm dia exhaust fan |
| 338 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light |
| 339 | CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose |
| 340 | S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. CompactSolarLEDStreetLight- 60W/12V/27Ah with GI pole |
| 341 | Supplyofmicroprocessorbasedthreephasesensingpowerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor,lag/leadcapacitorswitchingstatus,alarmoutputforunder current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 100 KVAR |
| 342 | SITC of 01 No. DG Set of Capacity 180 KVA 415+ volt with AMF control Panel cabling,copper earthing etc. complete in all respect.( As per Lataest CPCB- IV Emission Norm ) |
| 343 | Installation, testing and commissioning of 11 KV /.44 KV substations includingH.T.panelandL.T.panelincludingchequeredplates,all labour T&P complete in all respect. |
| 344 | Testing of DG., Transformer, HT and LT Panel etc at Manufacturer Works |
| 345 | 11/0.44KV SUB STATION AT MCWR |
| 346 | SupplyofstarratedCopperwounddistributionTransformer(Allthe distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C inoil/45degreeCinwinding,ISImarkeddrainvalve,Dialtype Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 400 KVA (1w+1s) |
| 347 | Supply of SCADA Compatible with RS 485 port 11KV,800 A, 25kA / 1 Sec, VCBIndoortypepanelHTboard,freestandingmotoroperated& withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With copper busbar, Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel, AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB |
| 348 | Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION800 A, 50KA, TPN, ACB, EDOmicroprocessor baseed(O/C,S/C) release-2No SpreaderLinks&ExtendedROH -2No,3PhaseDigital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A -1No, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2 No, 200 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2No, spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A |
| 349 | Supplyandlayingof11/12KVgradeXLPEinsulatedH.T. armouerd cableasper IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as perIS:1554P-I/IS:7098P-(I)fromUPPCL meteringpaneltoH.T. Switch gear panel and panel to transformers 120 Sq.mm. size |
| 350 | Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. |
| 351 | Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. |
| 352 | Supply & laying of L.T. XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 300 Sq.mm. (in 2 run for each transformer) |
| 353 | Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at WTP of 3.5C x 150 Sq.mm. |
| 354 | Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at MCWR of 3.5C x 400 Sq.mm. |
| 355 | EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 |
| 356 | Supplyingandlaying50mmX12mmG.I. stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 357 | Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 |
| 358 | Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness |
| 359 | NOC from electrical safety Dept. Govt. of UP |
| 360 | Fancing of substation in 2.5mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. |
| 361 | Internal & External electrification of Pump house :- |
| 362 | Twin tube light covered LED 20 Watt |
| 363 | 450 mm dia exhaust fan |
| 364 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light |
| 365 | CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose |
| 366 | Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay&enclosure(Confirms to IEC:60947-1&IEC: 60947-6-1)of 630 Amp |
| 367 | Supplyofmicroprocessorbasedthreephasesensing auto powerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current,insufficientcompensation,communicationinterfacewithRS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 200 KVAR |
| 368 | SITC of 01 No. DG Set of Capacity 380 KVA 415+ volt with AMF control Panel cabling, earthing etc. complete in all respect. ( As per Lataest CPCB- IV Emission Norm ) |
| 369 | Installation,testingandcommissioningof11KV/.44KVsubstations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. |
| 370 | Testing of D.G, Transformer, HT and LT Panel etc at Manufacturer Works |
| 371 | Automation of DMA |
| 372 | Flow Control Valve |
| 373 | Supplying, installing ,commissioning & testing of Flow Control Valvefor inlet with flow measuring, flow controlling, pressure monitoringandweb based with cable PLC etc Complete.Pattern Hydraulically operated self actuated flow & level control valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body, Y - Pattern, Double Chamber, unitized actuator, Fusion bonded epoxy coating, copper control tubing with Latching Solenoid & Pilot operated as per design, additional speed control feature, drip tight sealing, In-line serviceable, internals stainless steel & protected diaphragm suitable for drinking water. |
| 374 | For Zone -1 |
| 375 | 300 mm ( for OHT Inlet) |
| 376 | 250 mm ( DMA-1) |
| 377 | 250 mm ( DMA-2) |
| 378 | 250 mm ( DMA-3) |
| 379 | For Zone -2 |
| 380 | 300 mm ( for OHT Inlet) |
| 381 | 200 mm ( DMA-1) |
| 382 | 250 mm ( DMA-2) |
| 383 | 250 mm ( DMA-3) |
| 384 | For Zone -3 |
| 385 | 450 mm ( for OHT Inlet) |
| 386 | 300 mm ( DMA-1) |
| 387 | 400 mm ( DMA-2) |
| 388 | 300 mm ( DMA-3) |
| 389 | For Zone -4 |
| 390 | 100 mm ( for OHT Inlet) |
| 391 | 200 mm ( DMA-1) |
| 392 | IsolationValve |
| 393 | Supplying, installing ,commissioning & testing of DI Isolationvalve with electric acuator for isolation of DMA flow controling with cable PLC etc Complete. |
| 394 | For Zone -1 |
| 395 | 250 mm ( DMA-1) |
| 396 | 250 mm ( DMA-2) |
| 397 | 250 mm ( DMA-3) |
| 398 | For Zone -2 |
| 399 | 200 mm ( DMA-1) |
| 400 | 250 mm ( DMA-2) |
| 401 | 250 mm ( DMA-3) |
| 402 | For Zone -3 |
| 403 | 300 mm ( DMA-1) |
| 404 | 400 mm ( DMA-2) |
| 405 | 300 mm ( DMA-3) |
| 406 | For Zone -4 |
| 407 | 200 mm ( DMA-1) |
| 408 | Pressure Transmitter |
| 409 | Supplying, installing ,commissioning & testing of CE/UL Certified Pressure Transmitterfor pressure monitoring web based with cable PLC etc Complete for all 10 DMA,s of All 4 Zones |
| 410 | Electromagnetic Flow Meter |
| 411 | Supplying, installing ,commissioning & testing of CE/UL Certified Electromagnetic Flow Meterfor Flow monitoringweb based with cable PLC etc Complete |
| 412 | For Zone -1 |
| 413 | 250 mm ( DMA-1) |
| 414 | 250 mm ( DMA-2) |
| 415 | 250 mm ( DMA-3) |
| 416 | For Zone -2 |
| 417 | 200 mm ( DMA-1) |
| 418 | 250 mm ( DMA-2) |
| 419 | 250 mm ( DMA-3) |
| 420 | For Zone -3 |
| 421 | 300 mm ( DMA-1) |
| 422 | 400 mm ( DMA-2) |
| 423 | 300 mm ( DMA-3) |
| 424 | For Zone -4 |
| 425 | 200 mm ( DMA-1) |
| 426 | Residual Chlorine Analyser |
| 427 | SITC of Chlorine Analyser with MODBUS RTU having Following specification - (a) FRC senser range 0-5 ppm (b) Analyser with RS 485 O/P suitable to OHT distribution line and compatible with SCADA system toofor all 10 DMA,s of All 4 Zones |
| 428 | Chlorine Dozer For DMA |
| 429 | SITC of SCADA Compatible Chlorination Systemfor all 10 DMA,s of All 4 Zones |
| 430 | SCADA For DMA |
| 431 | CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Powersupply with annlog & digital parameter & featuers as specified, for each DMA to store and transmit dataon GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified intender technical specifications. |
| 432 | G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internetcharges as specified in tender technical specification . |
| 433 | Intelligent energy meters |
| 434 | Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps. |
| 435 | CE/ UL Certified 10\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. |
| 436 | CE/UL Certified 1 KVA UPS with Batteries for data backup. |
| 437 | CE/UL Certified 10 KVA UPS with Batteries for valve operation of each OHT . |
| 438 | Cabling |
| 439 | Complete Cabling for Intake well including all power & control cable of all equipments at ZPS and OHT. |
| 440 | SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories . |
| 441 | MASTER CONTROL STATION (MCS) AT WTP |
| 442 | CE/UL & BIS Certified industrial grade LED MONITOR with latestconfiguration as per specification 65\" |
| 443 | Video call media player of same OEM |
| 444 | Core i7 10th gen Desktop/ laptop with 32 GB RAM and 256 GB SSD + 1TB HDD |
| 445 | CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup |
| 446 | Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements |
| 447 | CE/ULcertifiedmastercontrolroomPLCwithredundantCPU&power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect |
| 448 | CE/UL certified Field gateway agent for transfering data forMCS/control room |
| 449 | GSM/GPRSbasedwireless/Broadband/equivelentcommunicationsystem for PLC Capable to transfer and receive data & gather data from remote sitestocontrolstationsallaccessoriesincludedwithsignalenhancer,antenna along with running expences |
| 450 | CE/UL certified Firewall for network protection |
| 451 | CE/UL Certified Surge protector for Ethernet communication protection |
| 452 | CE/UL Certified industrial grade Ethernet switch |
| 453 | Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) |
| 454 | Canon/HP or equivalent Laser Printer 1018 or equivalent. |
| 455 | Hp or equivalent multifunctioning Laser Printer with scanner |
| 456 | BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer |
| 457 | Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) |
| 458 | SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories. |
| 459 | Installation, Commissioning and testing of all above equipments for MCS with all power cables |
| 460 | TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY CHARGES |