Tender For Provn Of Containerised Accn Facility Toilet Block Site Offices And External Services At Af Stn Deesa Under Ge Af Baroda; 1 Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and all directed. 2 Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and all directed. 3 Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and all directed. 4 Returning, filling in, incl spreading, leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and all directed. 5 M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and all directed. 6 M&L for brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and dircted by engr-in-charge. 7 M&L for 10mm thick cement plaster in CM 1:6 on concrete or brick wall surfaces finished even & smooth without using extra cement complete all as specified 8 M&L for 15 mm rendering in two layers ie first layer 10 mm thick in CM 1:6 & further 5 mm thick with CM (1:4) using water proffing compound on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified. 9 M&L for accommodation facility (01 BED) (20ft X 10ft X 8.5ft) with attached Toilet &fully furnished single Sharing accommodation in each room with single Bed, 2 Almirah, 1 Dressing Table,1 Geyser, 3X3 ft Window ,6X3 ft Door, LED Light -4, Fan-1, Backlight-1 all as specified and as directed by Engineer-in-Charge/GE. 10 M&L for accommodation facility OFFICER (02 BED) (2 × 2) (20ft X 10ft X 8.5ft) with attached Toilet,fully furnished double Sharing accommodation in each room with single Bed,2 Almirah, 1 Dressing Table,1 Geyser,3X3 ft Window ,6X3 ft Door, LED Light -4, Fan-2, Backlight-1 all as specified and as directed by Engineer-in-Charge/GE. 11 M&L for accommodation facility WOs (3x2) (02 BED) (20ft X 10ft X 8.5ft) with fully furnished-Two Men accommodation in each room with Bunk Bed with 2 Almirah, 1 Dressing Table, 1 Geyser,3X3ft WINDOW,6X3ft DOOR, LED LIGHT-4,FAN-2 BACKLIGHT-1 all as specified and as directed by Engineer-in-Charge/GE.Note for Item 9 TO 11 .1.The Other Specification Include:- Base Frame:- 1. Bottom Frame 100mm X 50mm C channel 2. Stiffener Bottom 100mm x 50 mm 1 Beam.2. Side and End Walls 1. Paneling outside Specially G I Sheet (Galvanized Sheet) 2. Internal Wall Paneling 8 mm MDF OSL Sheet. 3. All Steel Sheets Used tested for corrosion resistance. 4. All gap sealed at edges & at seams, bottom etc.for preventing nearess of moisture.3. Flooring System: 1. Bottom flooring 18mm Cement Fiber Board of self-tapping screws) 2. Vinyl Carpet fixed on panel as directed by Eng-in-Charge.4. Roof: 1. Roof outside Specially (Galvanized Sheet) Property Stopped and water tight. 2. False Ceiling 8mm MDF-Plane White.5.Paint: 1. Outside Painting Phosphate the Cabin and painting with 1 coat of epoxy primer with Two Coat of Epoxy Paint.6.Insulation: 1. Insulation glass Wool density of 16kg/m3RB Wool Insulation.7.Main Entry Door: 1. Door with for locking agreement, Hold Draft & Handles.Aluminum Windows: 1. Aluminum Windows Double Shutter Sliding Aluminum Powder Coated Windows ASIS with Safety Grills. Electrical Systems and Wiring 1. All wiring shall be concealed type & shall be of copper wire. All electrical fitting in the portable cabin shall be 220-240 V, AC 50Hz Tubes Door Light, Fan, Switches, Socket, Telephone, Air Conditioners Point (MCB) All Type of Window Air Conditioning Systems as desired upon can be installed. Earthling point shall be provided for saftey. 12 1. Supply and install split Air conditioning unit (White), inverter type with split unitsindoor/outdoor with insulated copper tubing, Copper condenser coil, precision coolingtechnology, dual rotor inverter technology, R32 / R22/R410 or any other ecofreindlyRefrigerant, Brushless DC motor, 4-in-1 Convertible Cooling, auto clean, Magic DisplayEcofriendly refrigerant, copper wound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for batter indoor air quality5 siar rating ISEER 4.51 and of capacity 1.5 TR as comprising of the following:-(a) 1.5 Ton capacity using Eco friendly refrigernt cooling unit wall mounting typecomplete with remote control draining out arrangement manually adjustable cover forcool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. Make: Hitachi/blue star/LG/Voltas(b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as singleiphase electric driven compressor, condensing fan motor, condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge.Note :- (i) Additional length for copper tubing if required at site shall be supply and fix bythe contractor without any extra cost.(ii) Rate for filling of hole with white cement/POP including matching with existing surface included in item rate. 13 M&L for sand filling under floors or in foundations incl watering and consolidation etc complete all as specified and as directed. (Note : Punned thickness shall be measured for sand cushioning of UG cable). 14 M&L for machine pressed precast concrete interlocking paver block any shape and size cofirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed by Engr-in-charge. 15 M&L for PCC type B0 1:2:4 (12.5mm aggregate) for coping complete all as specified and as directed. 16 M&L PCC 1:2:4 type B1 20mm graded aggregate in foundation of the LTPanel including form work and all as directed by Engr-in-Charge 17 M&L for Bricks common burnt clay building bricks, sub-class Bdesignation of size 230mm x 115mm x 40mmfor cable protectionall as directed by Engineer-in-charge. 18 Supply, laying, testing and commissioning of XLPE insulated LT U/Gcable heavy duty,1100 volts grade, galvanized wire armoured andPVC sheathed with multistranded aluminium conductor of size 4 core16 Sqmm laid in trenches or fixed on wall (including saddle clip) orpoles drawn through pipes complete all as specified and as directed. 19 Supply, laying, testing and commissioning of XLPE insulated LT U/Gcable heavy duty, 1100 volts grade, galvanized wire armoured andPVC sheathed with multistranded aluminium conductor of size 3.5 core95 Sqmm laid in trenches or fixed on wall (including saddle clip) orpoles drawn through pipes complete all as specified and as directed. 20 Supply, laying, testing and comminssioning of XLPE insulated LT U/Gcable heavy duty, 1100 volts grade, galvanized wire armoured andPVC sheathed with multistranded aluminium conductor of size 3.5 core185 Sqmm laid in trenches or fixed on wall (including saddle clip) orpoles drawn through pipes complete all as specified and as directed. 21 Supply, install, commissioning and testing factory made (CPRIapproved manufacturer) LT panel box (KIOSK) out door type slze not less then 1500mm (W)x1500mm (H) x 500mm (D) platform mounted suitable for 415 volt, 3 phases, 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nosinsulated AL bus bars 400 amps rating installed on percelain insulators the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB Volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded toframe/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height .2 Nos earth terminal to be welded with feeder piller. The Complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032)including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :-(For Porta cabine)Incomer :-(a) MCCB FP 160 A, 36 KA with Electronic microprocessor release withover load Zone of adjustment 0,4 to 1.0 In and Electronic release withShort circuit Zone of adjustment 1.5 to 8.0 Ir. (Adjusted current) withtime with Extended Rotary Handle vari-depth type and Spreaderbetween phases and neutral. -01 no 22 (b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete--01-setOutgoing :-(c) MCCB TP 100A 36 KA with Adjustable Thermal release for over load 0.8 to 1.0 and Adjustable magnetic release (6-10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral, -06Nos Metering Compartment(d)Digital type Amp meter 0-200Amp (size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 250 A/5A-1No(e)Digital Type volt meter 0-500 V with selector switch -1Nos(g) RYB LED incating lamp-3 NosNotes :-(i)Cost of taking out old unserviceable panel is deemed to be included with unit rate of item(ii)Earth work, PCC base as directed by Engr-in-Charge etc is deemed to be included with unit rate of item.(iii) All MCCB to be installed vertically thereforpanel shall be designed accordigly.(iv)Taking Out Existing MCCBs of any Capacity from old LT panel to be fixed in any other LT Panel Boardand rate will be inclusive in this item for fixing in other panel or depositing in MESstore yard as directed by Engr-in-Charge. 23 Supply, install, commissioning and testing factory made (CPRI approved manufacturer) LT panel box (KIOSK) out door type, size not less then2000mm (W)x 2000mm (H) x 550mm (D) platform mounted suitable for 415 volt, 3 phases, 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base framework having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height. 2 Nos earth terminal to be welded with feeder piller. The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032)including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified:-(Location - NearMT)Incomer :- 24 (a) MCCB FP 400 A 50 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreaderbetween phases and neutral. -01 no (b) 4 Nos Aluminium Bus bar of 600 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase andneutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete-01 set Outgoing :-(c) MCCB TP 200 A 35 kA with Adjustable Thermal release for over load 0.8 to 1.0 and Adjustable magnetic release (6- 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -03 Nos(d) MCCB TP 100 A 36 kA with Adjustable Thermal release for over load 0.8 to 1.0 and Adjustable magnetic release (6- 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. 03 NosMetering Compartment(e) Digital type Amp meter 0-400 Amp(size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 400 A/5A-1 No(f) Digital Type volt meter 0-500 V with selector switch -1 Nos(g) Digital Multifunction meter having for measuring KW, KVA KVRa,KWAH, KVAH, Pf, Hz etc-1 Nos 25 (i) RYB LED incating lamp -3 NosNote :- (i) Cost of taking out old unserviceable panel is deemed to beincluded with unit rate of item.(ii) Earth work, PCC base as directed by Engr-in-Charge etc is deemed to be included with unit rate ofitem.(iii) All MCCB to be onstalled vertically therefor panel shall be designedaccordingly.(iv) Taking Out Existing MCCBs of any Capacity from old LT Panel tobe fixed in any other LT Panel Board. wherever required and rate willbe inclusive in this item for fixing in other panel or deposited in MES store yard as directed by Eng-in-Charge. 26 Supply and fixng VTPN load DB 4 way Sheet metal encloser including MCCB 63 Amp 25 KA and MCB SP. 27 Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete.in intenal surfaces of pole including providing 5Nos synthetic enemelled paint bends (in skyblue and white coloure) of 30cm each as in repairs for 410 SP-31 (9 mtr long) complete all as specified and directed.Note: Excavation / earth work and PCC work shall be measured andpaid separately under respective items of BOQ 28 Supply and fixing of Galvanised steel tubes, light grade of 40mm bore for cable protection laid in pole coping, on wall/ under the road complete all as specified and directed.Note :-(i)Cost of Bends under the coping, demolition of existing PCC for layingof pipe are deemed to be included with unit rate of item. (ii)Taking down of old GI Pipe of any size is deemed to be included inquoted rate 29 Supply and fix in repair 1.5 sqmm three core PVC insulated, PVC sheathed multistranded copper conductor cable 1100 volts grade from junction box to street light fittings complete all as specified and directed 30 S&F Junction box 290x200x130 mm polycarbonate/ ABS hinged enclosure box IP-66/67 for cable in/out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles, 4 poles 100 Amp connector/ terminal assembly with nut bolt and washer, including MCB SP 6A, 240V, 10 KA -01 Nos for connectingsuitable size of XLPE UG cable all as specified and directed. 31 Supply and fix LED street light fitting of 70 Watt LED IP-66, sealedoptic luminaire with housing made of die cast aluminium with smoothfinish powder coated for better environmental protection completeincluding 1200mm long Gl pipe (40mm bore) light grade breaket bend to shap, Fl clamp 50mmX6mm-2 Nos all as specified below-(i) The fixture shall be designed so as to average lumenmaintenance of at least 70% at the end of 70000 hours.(ii) The luminaire should be operable with auto adjustable 120-240volt supply using the same driver. Ambient temperature at LED shouldnot be more that 70 degree centigrade.(iii) Power factor of the electronic driver should be at least 0.90 abdefficiency of the luminaire to be nore than 85%.(iv) The fixture should be dark sky complaint. The fixture should usealuminium, MCPCB printed circuit boards for better thermalmanagement.(v) The luminaire should throw the perfect amount of uniform light 32 S&F of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based. on Natural light Lux level. Required illuminance level for Switching ON is<= 30 lux and for switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along withsuitable Power contactors, incoming-outgoing MCBs and Auto manual(Sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, temite proof and FR grade IP66 protection class 2 Enclosure made of thermoplastic polycarbonate and protected against weather influences. For three phase load of 5KW (Swadeep02 EC dual series- 5kW3P) with: 3 Nos contactors, 3 nos incoming MCBs & 3 nos outgoing MCBs of 20-25 Amps each and 1 No time switch & circuit wiring (copper) of min 10 sqmm complete all as specified and directed. 33 Earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1,5 metres below normal around level, connected togalvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated including testing on completion including excavation & earth work in any type of soil/strata, PCC(1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in: reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade Gl watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc.complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in lengthshall be measured and paid extra.. 34 M&L Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x6 mm burried directly in ground vetically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised eath lead as GI strip of 32X6mm size by means of bolts, nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation & earth work in any type of strata, PCC(1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in: reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade Gl watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc.complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in lengthshall be measured and paid extra. 35 Supply & laying in trenches 100mm bore DI pipe Class K-7 With tyton Rubber joint and fittings complete all as specified & directed by Engr-in-Charge. 36 Supply & laying in trenches/Walls 25mm GI medium grade, ISI marked with GI fitting such as tees, bend, elbows connecting to existing water main all as directed by the Engr-in-Charge. 37 Supply and fixing of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engr-in-Charge. 38 Supply and fixing sluice valve. 100mm bore flanged type of class 1.6 PN includes rubber packing and nuts and bolts required complete all as specified & directed by Engr-in-Charge. 39 M&L for valve pit chamber ofsize 1000mmx1000mmx1000mm with angle Iron frame 50x50x6 mm, 3 mm thick MS cover, excavation work, 10 mm thick plastering in CM 1:4 inside and outside, coping 50mm in cement concrete 1:2:4 type B1, Brick masonry of 23 mm thick in cm 1:4, PCC 1:3:6 in foundation work earth and excavation work in any type of soil complete Job all as directed by Engr-in-Charge. 40 M&L for common Toilet Bunk House (20ftX10ftX8.5ft) with fully furnished with Shower-3, Toilet EWC-3 and Wash Basin -2, Exhaust fan with ventilation-6, light-8 etc all as specifed and as directed by Engr-in-Charge. 41 Note for item No 37.1.The other specification including-Base Frame :- (i) Bottom frame 100mmx50mm C channel. (ii)Stiffener Bottom 100mm x 50mm 1 Beam.2. Side and End Walls:- (i) Panelling outside specially G I Sheet (Galvanized Sheet)(ii) Internal Wall Paneling 8mm MDF OSL Sheet.(iii) All steel sheets used tested for corrosion resistance.(iv) All Gap sealed at edges & at seams, bottom etc for preventing nearess of moisture.3.Flooring System :- (i)Bottom flooring 18mm Cement fiber Board (Fixed by means of self- tapping screws) (ii)Vinyl Carpet Fixed on panel.4.Roof :- (i) Roof outside specially (Galvanized Sheet) Properly stopped and water tight. (ii) False ceiling 8mm MDF-Plane white5.Paint :- (i)Outside Painting Phosphate the Cabin and painting with 1 coat of epoxy primer with Two Cost of Epoxy Paint6.Insulation :- (i)Insulation glass wool density of 16kg/ M3 RB wool insulation.7.Main Entry Door :- (i)Door with for locking arrangement, Hold fast &Handles.8. Aluminum Windows :-(i)Aluminium Windows Doublesliding Aluminum Powder CoatedWindows ASIS with Safety Grills.Electrical systems andwiring :-(ii)All wiring shall be concealed type & shall be of copper wire. (iii) All electrical fitting in the portable cabin shall be 220-240 V, AC 50Hz Tubes Door Light, Fan, Switches, Socket, Telephone, Air Conditioning Point (MCB). (iv) All type windows Air Conditioning Systems as desired upon can ce installed.Earthing point shall be provided for safety. 42 M&L for RCC NP3 150 mm diameter Pipes for depth 0.7m to 1.65m laid on150 mm thick bed PCC 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional in all respect complete all as specified and directed. 43 M&L for 10 user capacity conventional type on site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed by Engr-in-Charge/ GE. 44 M&L for 30 user capacity conventional type on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed by Engr-in-Charge/ GE. 45 M&L for soakage well of size 1.8M dia and 3.0 M effective depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of appropriate size complete all as specified and directed by Engr-in-Charge/ GE. 46 M&L for Office facility (1 x 2) (20ft x 10ft x 8.5ft) with fully furnished- 2 Almirah, Table 4, Side table 2, Chair 8, 1.5 Air conditioning, LED light-4, Fan-2, Backlight-1 all as specified and directed by Eng-in-Charge/GE. 47 M&L for Office facility(5 x 4) (20X10X8.5) with fully furnished- 2 Almirah, Table 4, Side Table-2, Chair-8, 1.5 Air conditioning, LED Light-4, Fan-2, Backlight-1 all as specified and directed by Eng-in-Charge/GE.Note foritem No 42 & 431.The other specification include:-(i) Base Frame-1Bottom, Frame 100mm X 50mm C channel (ii)Stiffener Bottom 100mm x 50mm 1 Beam.2.Side and End Walls :- (i) Paneling outside Specially G.I Sheet (Galvanized Sheet)(ii) Internal wall paneling 8 mm MDF OSL Sheet (iii)All steel sheets used tested for corrosion resistance. (iv)All gap sealed at edges & seams, bottom etc for preventing nearess of moisture.3.Flooring system :-(i) Bottom flooring 18mm Cement Fiber Board (Fixed by means of self tapping screws) (ii)Vinyl Carpet fixed on panel.4. Roof outside specidly (Galvanised sheet).(i) Properly stopped and water tight.(ii) False ceiling 8mm MDF- plane white.5.Paint :- (i) Outside Painting phasphate the Cabin and painting with 1 coat of epoxy primer with Two coats of Epoxy paint.6.Insulation. :- (i)Insulation glasss wool density of 16 kg/m3RB wool insulation.7.Main Entry Door :-(i) Door with for locking agreement.Hold fast & Handles Aluminum Windows.(i) Aluminium Windows Double Shutter sliding Aluminium Powder Coated Windows ASIS with Safety Grills.Electricalssystem and Wiring.(ii) All wiring shall be concealed type & shall be of copper wire.All electrical fitting in theportable cabin shall be 220-240 V. AC 50Hz Tubes Door Light, Fan, switches, Socket, Telephone, Air Conditioners Poiint (MCB) All type of Window Air Conditioning Systems as desired upon can be installed Earthing point shall be provided for safety.