Tender For Repair / Replacement, Maint, Internal Wiring, Light Fittings, Mcbs, Dbs, Street Light, Junction Box And Cable And Allied Works At 799 Su Afs Kurseong Under Ge (Af) Bagdogra
Tender Value
33 Lakhs
Estimated cost
Bid Submission
28 Aug 2025
0 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kurseong → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair / Replacement, Maint, Internal Wiring, Light Fittings, Mcbs, Dbs, Street Light, Junction Box And Cable And Allied Works At 799 Su Afs Kurseong Under Ge (Af) Bagdogra
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/ aluminium point wiring for light, fan, socket or power point complete including making good the disturbed surface on walls, complete all as directed. |
| 2 | M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover/Hylem Sheet for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One light point/fan point/Bell point/ 5 Amp socket independent board controlled by one 5/6 Amps one way switch, complete all as specified and as directed. Note:-(i) All the disturbed surfaces of wall / ceiling shall be made good to match the existing wall / ceiling finishes and as directed by the Engineer-in-Charge. |
| 3 | All as per item No 2 above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and directed. |
| 4 | All as per item No 2 above but for one light point controlled by two 5/6 Amps two way switch complete all as specified and directed. |
| 5 | All as per item No. 2 above but for 15/16Amp switch socket out let, independent with 2.5 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 2.5 Sqmm for earth continuity conductor, complete all as specified and directed. |
| 6 | All as per item No. 2 above but for 15/16Amp switch socket out let, independent with 4.0 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified and directed. |
| 7 | M&L Point Wiring foronelight/Ceiling/Exhaust Fanpointcontrolled byoneswitch with 1.5 Sqmm Copper Conductor single core PVC insulated (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including Rigid PVC Concealed Conduit, medium grade, ISI marked of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on modular Sunk Mild Steel Pressed Terminal Box 1.22 mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover/hylem sheet /modular base plate and front plate for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly duly fixed with copper lugscomplete all as specified and as directed. Note:- Cutting chases for concealed Conduit wiring will be measured and paid separately. |
| 8 | All same as item No. 07 above, but foronesocketpoint5Ampsontheindependentboard complete all as specified and directed. |
| 9 | All same as item No. 07 herein before, but foronesocketpoint5Ampsontheindependentboard but below the switch board of light point in same vertical plane complete all as specified and directed. |
| 10 | All same as item No. 07 herein before, but foronesocketpoint5Amps on same board complete all as specified and directed. |
| 11 | All same as item No. 07 herein before, but for one light point controlled by two way switch complete all as specified and directed. |
| 12 | All same as item No. 07 herein before, but for one bell/buzzer point controlled by one push button on same board or independent with cable 1.5 sqmm complete all as specified and directed. |
| 13 | All as per item no 7 here in beforebut using 2.5 sq mm single core copper conductor cable of multistrand FRLSH grade PVC insulated Unshethed 1100 volt grade for 16 Amps socket combination pt. including running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuety conductor along with wiring and connecting to common earth dolly for One 6 pin multisocket outlet, 16Amps , complete all as specified and directed. |
| 14 | All as per item no 7 here in beforebut using 4 sq mm single core copper conductor cable of multistrand FRLSH grade PVC insulated Unshethed 1100 volt grade for 16 Amps socket combination pt. including running of 4 sq mm copper conductor FRLSH PVC wire as earth continuety conductor along with wiring and connecting to common earth dolly for One 6 pin multisocket outlet, 16Amps , complete all as specified and directed. |
| 15 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and cutting not exc 10 cm girth and making good the matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required(as per the existing condition) complete all as specified and directed. |
| 16 | Taking down by unscrewing from boards/outlet boxes,unsv fittings and fixtures such as switches, Sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc complete all as specified and directed. |
| 17 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, Sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site or carrying to the store(To be measured only when found serviceable in all respects complete for reuse). complete all as specified and directed. |
| 18 | Supply and fixing of switch paino,flush type,single pole,one way, 5/6 Amp, 230 Volt. complete all as specified and directed. |
| 19 | Fixing only switch piano single pole flush type 5 amps, 230 volts obtained from item No 12 above complete all as specified and directed. |
| 20 | Supply and fixing of bell push, 5 Amp, 230Volt, complete all as specified. |
| 21 | Supply and fixing of bell electric Ding Dong type, Ac 230 volts fixed complete all as specified and directed. |
| 22 | Supply and fixing of ceiling rose, surface Bakelite 65 x 30mm, three terminals,complete all as specified and directed. |
| 23 | Fixing onlyceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm obtained from item No 12 above complete all as specified and directed. |
| 24 | S & Fsocket (ISI marked) flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts complete all as specified and directed. |
| 25 | Fixing only socket flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Voltsobtained from item No 12 above complete all as specified and directed. |
| 26 | Supply and fixing of switch socket combination (ISI marked) 2 pin & 3 pin 5 Amp,230 volt,multipurpose, 2 screw to fix on board complete all as specified and directed. |
| 27 | Supply and fix in replacement switch socket combination(ISI marked) 2 pin & 3 pin 5 Amp,230 volt,multipurpose, 2 screw with PVC box fix on wall complete all as specified and directed. |
| 28 | Fixing onlyswitch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1230 Voltsobtained from item No 12 above complete all as specified and directed. |
| 29 | Supply and fixing of switch socket combination 5 in 1 type, 3 pin 5 / 15Amp,230 volt,multipurpose, 4 screws to fix (porcelain) on board complete all as specified and directed. |
| 30 | Supply and fix in replacement switch socket combination 5 in 1 type, 3 pin 5 / 16Amp,230 volt,multipurpose, 4 screws (porcelain) with PVC box to fix on wall complete all as specified and directed. |
| 31 | Fixing only switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type obtained from item No 12 above complete all as specified and directed. |
| 32 | Supply and fixing of switch paino,flush type,single pole,two way, 5/6 Amp, complete all as specified and directed. |
| 33 | S & F lamp holder with metal ring, insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/square blocks complete all as specified and directed. |
| 34 | Fixing only lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/square blocks obtained from item No 12 above complete all as specified and directed. |
| 35 | S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed. |
| 36 | S & F Modular Switch 2 way 6 A, 1 module complete all as specified and directed. |
| 37 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed. |
| 38 | S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 39 | S & F Modular Socket 6 A/ 16 A, 2/3/5 pin combined 2 module complete all as specified and directed. |
| 40 | S & F Modular Bell Push Switch 1 way 6 A, 1 module complete all as specified and directed. |
| 41 | S & F Modular Blank plate, 1 module complete all as specified and directed. |
| 42 | S & F Modular type White cover plate with frame 1 module complete all as specified and directed. |
| 43 | S & F Modular type White cover plate with frame 2 module complete all as specified and directed. |
| 44 | S & F Modular type White cover plate with frame 3 module complete all as specified and directed. |
| 45 | S & F Modular type White cover plate with frame 4 module complete all as specified and directed. |
| 46 | S & F Modular type White cover plate with frame 6 module complete all as specified and directed. |
| 47 | S & F Modular type White cover plate with frame 8 module complete all as specified and directed. |
| 48 | S & F Modular type Metal Flush box 1 or 2 module complete all as specified and directed. |
| 49 | S & F Modular type Metal Flush box 3 module complete all as specified and directed. |
| 50 | S & F Modular type Metal Flush box 4 module complete all as specified and directed. |
| 51 | S & F Modular type Metal Flush box 6 module complete all as specified and directed. |
| 52 | S & F Modular type Metal Flush box 8 module complete all as specified and directed. |
| 53 | Fixing onlyModular Switch 1 way 6 A, 1 module complete all as specified and directed. |
| 54 | Fixing only Modular Switch 1 way 16 A, 1 module complete all as specified and directed. |
| 55 | Fixing only Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 56 | Fixing onlyModular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 57 | Fixing onlyModular type White cover plate with frame 1/2/3/4/6/8/12 module complete all as specified and directed. |
| 58 | Supply and fix motor starter switch white colour 25 Amp push botton type 2 module complete all as specified and directed. |
| 59 | Supply only plug top 3 pin 15 Amp ISI marked complete all as specified and directed. |
| 60 | Supply onlyplug top 3 pin 5 Amp ISI marked complete all as specified and directed. |
| 61 | Taking down the complete hanging lamp fitting of any type and any location and refixing the same with accessories, including provision for cable from celling rose to fitting, complete all as specified and directed. |
| 62 | Supply and fix in replacement 10 W tubelight fitting with lamp, LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation having THD<20% with complete fittingcomplete all as specified and directed. |
| 63 | Supply and fix in replacement of 12 Watt LED Bulk Head fitting Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge- lit LED luminaries comprising of high brightness LEDs complete all as specified and as directed. |
| 64 | Supply and fix in replacement of 20 W tubelight fitting with lamp, LED Wall mounted LED batten with PC diffuser and aluminium housing & intergated driver for efficient heat dissipation having THD<20 %, efficiency125 lm/W, 6500K with complete fittingall as specified and as directed. |
| 65 | Supply and fix in replacement20 Watt T-8 LED tubelight having efficiency of 100 lumen/watt in existing fitting complete all as specified and directed. |
| 66 | Supply and fix in replacement of 36 W, 240 Volt, 50 HZLED recessed mounted 2X2 tile, glare free uniform illuminationhaving THD<20 %, 6500 k, with complete fitting(L bracket/Spring Clamps option)all as specified and directed. |
| 67 | Supply and fix in replacement of 12 W, 240 Volt, 50 HZLED recessed mounted, edge lit slim, downlight with dia-cast aluminium housin having THD<20 %, Cool day light temp,efficiency 120 lm/W with complete fittingall as specified and as directed. |
| 68 | Supply and fix in replacement of 18 W, 240 Volt, 50 HZLED recessed mounted, edge lit slim, downlight with dia-cast aluminium housin having THD<20 %, Cool day light temp,efficiency 120 lm/W with complete fittingall as specified and as directed. |
| 69 | Supply and fix in replacement of 12 W, 240 Volt, 50 HZ, 6500 K LED recessed mounted glare free uniform illumination having THD<20 %, Cool day light temp,efficiency 100 lm/W with complete fittingall as specified and as directed. |
| 70 | Supply and fix in replacement of 05 W, 240 Volt, 50 HZLED spike light using COB LED as light sourcehaving THD<20 %, IP-66, with complete fittingall as specified and as directed. |
| 71 | Supply and fix in replacement of 06 W, 240 Volt, 50 HZLED spot down lighthaving THD<20 %,with complete fittingall as specified and as directed. |
| 72 | Supply and fix in replacement of 09 W, 240 Volt, 50 HZLED wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lamp with complete fittingall as specified and as directed. |
| 73 | Supply and fix in replacement of240 Volt, 50 HZLED wall mounting gold finish fixture with cognac hammered glass diffuser suitable for 7.5 W LED filament lamp E27 base with complete fittingcomplete all as specified and directed. |
| 74 | Supply and fix in replacementLED retrofit lamp B22holder base with polycarbonate body and aluminium heat sinkof 09/10W, 6500 K, 3 star rating complete all as specified and directed. |
| 75 | Supply and fix in replacement7.5 W LED filament lampE27 holder base with aluminium heat sink , 2500 K,complete all as specified and directed. |
| 76 | Supply and fix in replacementLED AC Strip rope,IP 65, 3000 K ,complete all as specified and directed. |
| 77 | Supply and fix in replacement of LED security light35 W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and directed. |
| 78 | Supply & fixing in replacement street light bracket fabricated from 25mm dia medium grade GI pipe bent to shape not exceeding 1.5mtr long alongwith 2 Nos clamps of size 32x6mm flat iron and including nuts, bolts, washers suitable for fixing on Buildings including 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 79 | Taking down un-serviceable sub main wiring of any type and any size and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour of the wall with wash/paint/distemper whenever required(as per the existing condition) complete all as specified and directed. |
| 80 | M & L forsub main wiring withtwo run of 4.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH gradeand one run of copper earth wire 4.0 Sq mm drawn through PVC casing and caping, complete all as specified and directed. Note : Copper conductor 2 run and one run of copper earth wire along withPVC casing and caping shall be measured as one length. |
| 81 | M & L for sub main wiring withtwo run of 6.0 Sq. mm PVC sheathed, copper conductor cable, 1100 Volt, FRLSH grade and one run of copper earth wire 6.0 Sq mm drawn through PVC casing and caping, complete all as specified and directed. Note : Copper conductor 2 run and one run of copper earth wire along with PVC casing and caping shall be measured as one length. |
| 82 | M&L sub main wiring with 4 runs of 6 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLSH grade with drawn insurface casing-caping not less than 25mm dia and one run of PVC insulated unserviceable of 6 sqmm as earth continuity conductor drawn in PVC conduit / casing and capping with accessories complete all as specified and directed. NOTE: 4 runs of 6 Sqmm, 1 run of 6 Sqmm and 1 run of conduit will be measured as one unit i.e RM |
| 83 | M&L sub main wiring with 4 runs of 10 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLSH grade with drawn insurface casing-caping/PVC Conduit not less than 32 mm dia and one run of PVC insulated unserviceable of 10 sqmm as earth continuity conductor drawn in PVC conduit / casing and capping with accessories complete all as specified and directed. NOTE: 4 runs of 10 Sqmm, 1 run of 10 Sqmm and 1 run of conduit will be measured as one unit i.e RM |
| 84 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/including MCCB / MCB TPN/SPN/SP any description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 85 | Supply and fix factory made sheet metal enclosure withprotected type 2 pin and earth plug and complete socket with one MCB SP 240 volt, 20 Amps complete all as specified and directed. |
| 86 | Supply and fix Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt,12 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and directed. |
| 87 | Supply and fix Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt,8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified and directed. |
| 88 | Supply and fix Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt,4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified and directed. |
| 89 | Supply and fix Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt,4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified and directed. |
| 90 | S & FMCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA \"C\" series, complete all as specified and directed. |
| 91 | Supply and fix in replacement of MCB 32 Amp, 240 Volt, SPN, breaking capacity 10 KA \"C\" series, complete all as specified and directed. |
| 92 | Supply and fix in replacement of MCB 40 to 63 Amp, 240 Volt, DP, breaking capacity 10 KA \"C\" series,complete all as specified and directed. |
| 93 | Supply and fix in replacement ofMCB 40-100 Amp, 415 Volt, TPN, breaking capacity 10 KA \"C\" series, complete all as specified and directed. |
| 94 | Taking down and re-fixing of existing hanging conduit/Casing capping wiringwith proper saddles, complete all as specified and directed. Note :- (i) Unsv PVC conduit/Casing capping/dummy plate will be measured and paid separately (ii) Making good disturbed surfacedeemed to be inclusive of quotedrate |
| 95 | Supply only rigid non-metallic PVC conduit of size 32 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 96 | Supply only Rigid non-metallic PVC conduit of size 25 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 97 | Supply only Rigid non-metallic PVC conduit of size 20 mm in dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 98 | Supply only round dummy plate for electric wiring junctions, complete all as specified and directed. |
| 99 | Supply onlyPVC casing and capping of size 25mmduly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and directed. |
| 100 | Supply onlyPVC casing and capping of size 20 mmduly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and directed. |
| 101 | Supply and fix PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100mmX100mm and 50 mm deep, complete all as specified and directed. |
| 102 | Supply and fix PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175mmX100mm and 50 mm deep, complete all as specified and directed. |
| 103 | Supply onlyPVC20mm wideInsulation Tapeof length25 meter complete all as specified and directed. |
| 104 | S & FPVC Surface Box of Size 4\"\" x 4\"\" including replacement of old UNSV one and refixing of old switch sockets as per existing at sitecomplete all as specified and directed. |
| 105 | S & FPVC Surface Box of Size 7\"\" x 4\"\" including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. |
| 106 | S & FPVC Surface Box of Size 8\"\" x 6\"\" including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. |
| 107 | Supply and fixing in repair of Hylem sheet (ISI Marked) of size 9X11inch with 4 no of screws and washers complete all as specified and directed. |
| 108 | Supply and fixing in repair of Hylem sheet (ISI Marked) of size 9 X 7 inch with 4 no of screws and washers complete all as specified and directed. |
| 109 | Supply and fixing in repair of Hylem sheet(ISI Marked) of size 5X7 inch with 4 no of screws and washers complete all as specified and directed. |
| 110 | Supply and fixing in repair of Hylem sheet(ISI Marked) of size 5X5 inch with 4 no of screws and washers complete all as specified and directed. |
| 111 | Supply and fixing in repair MS sunken box of size 8 x 10 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as specified and directed. |
| 112 | Supply and fixing in repair MS sunken box of size 8 x 6 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as specified and directed. |
| 113 | Supply and fixing in repair MS sunken box of size 6 x 4 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface c complete all as specified and directed. |
| 114 | Supply and fixing in repair MS sunken box of size 4 x 4 inch with 4 no of screws and washers including taking down the existing and making good to match the existing surface complete all as specified and directed. |
| 115 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground(earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanisediron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways,20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. |
| 116 | M&L for earth continuity fixed to wall on batten or rececc or chases or buried in ground or drawn in conduit/pipe or other indicated situation for loop earthing etc as required 4mm dia GI or steel earth wire complete all as specified and directed. |
| 117 | Material and labour forPCC Chamber cover 40 mm thick of internal size 300 mm x 300 mm x 300 mm in PCC (1.3:6) type C1 (using 20 mm graded stone aggregate) with pit cover of 300 mm x 300 mm with RCC 1:2:4 type B1 cover 40mm thick, with 8 mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, along with provision ofhandle with 10 mm GI bar and funnel for water pipe complete including dismantling old PCC Chamber complete all as specified and directed. |
| 118 | Material and labour for adding salt upto 35 Kgs duly mixedwater to make the existing earthing serviceable and to get the desired earth values complete all as specified and directed. Note:- Cost is inclusive of replacement of rusted bolts, nuts, check nuts and washers of galvanisediron or steel, Funnel |
| 119 | Material and labour for charging of earth pit with conductolite back fill compound series upto 5 Kgs duly mixed withwater to make the existing earthing serviceable and to get the desired earth values complete all as specified and directed.Note:- Cost is inclusive of replacement of rusted bolts, nuts, check nuts and washers of galvanisediron or steel, Funnel |
| 120 | Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall or for repair and re-installation at any location including S&F in repair of heavy duty pin type fastener 4 inch Job long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and directed. |
| 121 | Inspection, checking adjustments and repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :-(a) Inspection, taking out of drain plug & dewatering and refixing the same complete all as directed .(b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts.(d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow.(e) Checking and correct earth continuity of electrical items.(f)Checking functioning of heating elementand correct setting adjustment of thermostat upto 55º C.(g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) The cost of spare parts required for repair & mainenance of geysers covered under this item shall be measured and paid separately under the relevant item as supply only. (j) Make of geysers covered under the scope of work :- Sidhson, bajaj, recold, crompton, orison, ditz premier, peeco, empire, shakti, sahas, konark USHA, Havells. |
| 122 | Supply only heating element, Round type / tikona type / banana type,2 KW 230 volts, ISI marked suitable for 25/35/50 ltrs geysers of any make complete all as specified and directed. |
| 123 | Supply only thermostat switch with/without reset botton as per sample for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and directed. |
| 124 | Supply and fixing glass wool for geysers complete all as specified and directed. |
| 125 | Supply only base assembly made up of SS-304 compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and directed. |
| 126 | Supply only indicator lamp for geyser of any type colour green & red complete all as specified and directed. |
| 127 | Supply only stainless steelinner tank of minimum 22 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25/35 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and directed. |
| 128 | Supply only of stainless steel inner tank of minimum 22 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and directed. |
| 129 | Supply only outer body of MS sheet not less than 22 gauge suitable for 25/35 ltr geyser with white synthetic enameled paints complete all as specified and directed. |
| 130 | Supply only outer body of MS sheet not less than 22 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and directed. |
| 131 | Supply only Top/bottom/Show cover of MS suitable for 25/35 ltrs capacity geysers complete all as specified and directed. |
| 132 | Supply and fix in replacement Stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, chromium plated fancy type, screwed both ends for 15mm bore iron pipe or for union, ISI marked, fixed as in repair complete all as specified and directed. |
| 133 | Supply and fix in replacement Bib tap, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, fixed as in repair complete all as specified and directed. |
| 134 | Supply and fix in replacement Brass Mixer tap cast copper alloy chromium plated, fancy type, wall mounted, suitable for mixing hot and cold water screwed for 15mm bore iron pipe, ISI marked, fixed as in repair complete all as specified and directed. |
| 135 | Supply and fix in replacement Stainless steel connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe, fixed as in repair complete all as specified and directed. |
| 136 | Supply and fix in replacement stainless steelconnection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe fixed as in repair complete all as specified and directed. |
| 137 | Supply and fix in replacement 3 core PVC insulated copper cable of size 2.5 Sqmmmulti stranded fixed as in repair complete all as specified and directed. |
| 138 | Supply and laying in floor, fixed to walls and ceiling, 25mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and directed. |
| 139 | Supply and laying in floor, fixed to walls and ceiling, 20 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and directed. |
| 140 | Supply and laying in floor, fixed to walls and ceiling, 15 mm bore galvanised steel tubing medium grade, ISI marked, including fittings including taking down existing unserviceable pipe, making good to floor, wall and ceiling as per existing complete all as specified and directed. |
| 141 | Material & Labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc complete all as specified and directed. |
| 142 | Material and Labour for Painting of outer surface of 25/35/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting complete all as specified and directed. |
| 143 | Supply and fix Instant hot water instrument for 3 Itr capacity 3 KW fixed as in repair complete all as specified and directed. |
| 144 | Supply and fix Oil filled radiator heater 2.5 KW, 13 fins and 400 watt power fan suitable to operate in 3 position complete all as specified and directed. |
| 145 | Disconnecting and taking down Exhaust Fan of any Sweep for rewinding by disconnecting Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including, re-fixing in Original Position checking smooth functioning and including electrical connection with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan cleaning all dust, etc. after repair and testing complete all as specified and directed. |
| 146 | M&L rewinding Exhaust Fan 450 mm Sweep of any Make and type with Super Enamelled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for satisfactory runningand testing, complete all as specified and directed. |
| 147 | All as per sr item no 146 but for 380 mm Sweep exhaust fan complete all as specified and directed. |
| 148 | All as per sr item no 146 but for 300 mm Sweep exhaust fan complete all as specified and directed. |
| 149 | Supply and fix in replacement of louvers suitable for 450 mm sweep exhaust fan complete all as specified and directed. |
| 150 | Supply and fix in replacement of louvers suitable for 300/380 mm sweep exhaust fan complete all as specified and directed. |
| 151 | Supply and fixing Ball Bearing (as approved) suitable for Exhaustfans of size 300/380/450 mm complete all as specified and directed. |
| 152 | Supply and fixing Gun MetalBush (as approved)suitable for Exhaustfans300/380/450 mm sweep complete all as specified and directed. |
| 153 | Supply and fix in replacement of PVC fan blade of exhaust fan of 200mm sweep as per existing complete all as specified and directed. |
| 154 | Supply and fix in replacement of blower motor of PVC sturdy plastic fan of 200 mm sweep as per existing complete all as specified and directed. |
| 155 | Supply and fix in replacement of PVC fan blade of exhaust fan of 250mm sweep as per existing complete all as specified and directed |
| 156 | Supply and fix in replacement of blower motor of PVC sturdy plastic fan of 250 mm sweep as per existing complete all as specified and directed. |
| 157 | S & F1100 volts gradePVC insulatedstranded Flexible Copper conductor twin core of 1.0 Sqmm from ceiling rose to fan/exhaust fans/ air circulator, etccomplete all as specified and directed. |
| 158 | Supply and fix in repairexhaust fan capacitor4 mfd of approved makecomplete all as specified and directed. |
| 159 | Supply and fix in repairexhaust fan capacitor2.5 mfd of approved makecomplete all as specified and directed. |
| 160 | M&L for Painting with ivory synthetic enameled paint after preparation of old surface of the Exhaust fan of any make/model of sweep,450 mm including filling cavities with filler after cleaning dust and refixing the same complete all as specified and directed. |
| 161 | M&L for Painting with ivory synthetic enameled paint after preparation of old surface of the Exhaust fan of any make/model of sweep,380 mm including filling cavities with filler after cleaning dust and refixing the same complete all as specified and directed. |
| 162 | M&L for Painting with ivory synthetic enameled paint after preparation of old surface of the Exhaust fan of any make/model of sweep,300 mm including filling cavities with filler after cleaning dust and refixing the same complete all as specified and directed. |
| 163 | M & L for servicing of wall mount modular electric chimeny 230 V with authorized service engineer of company,cleaning of external/internal surface removing Oil/greece from Oil seperator, baffle filter, fan and blower motor, hose pipe etc includinf servicing of blower motor completely complete all as specified and directed. Note:- Cost is inclusive of any spare parts/rewinding of motor required during servicing |
| 164 | Excavation in trenches exceeding 1.5 M in wide and not exc. 3.0 M in depth for taking out or laying ofunderground cable/pole in soft / loose soil complete all as specified and directed. |
| 165 | Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying ofunderground cable/pole in hard dense soil complete all as specified and directed. |
| 166 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and directed. |
| 167 | Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M abovethe starting point complete all as specified and directed. |
| 168 | Materials and labour for plain cement concrete (1:2:4) type B1 (using 20mm graded aggregate) as in copings and footings for poles etc including necessary formwork complete all as specified and directed. |
| 169 | Materials and labour for plain cement concrete (1:4:8) type D2 (using 40mm graded aggregate)as in foundations , filling and mass concrete complete all as specified and directed. |
| 170 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the existing surface with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed. |
| 171 | Supply and fixing HDPE double wall Corrugated Duct Pipe of Size 40 mm OD and 32 mm ID for Cable Protection laid in trench complete all as specified and directed. |
| 172 | M & L for demolition of old unserviceable steel tubular pole after taking out carefully all serviceable items such as termination box, street light, street light bracket, Channeland other itemsand keeping the serviceable item in safe custody for reuse and removing the demolished pole from site complete all as specified and directed. |
| 173 | Supply & Erecting in replacement Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No. with synthetic Enamel Paint (First Grade/quality), complete all as specified and directed. NOTE: Earthwork, Cement Concrete, etc. will be measured and paid under appropriate Items. |
| 174 | Taking up/down existing defective cable of sizes 2/3/4 core 10 to 35 sqmmfrom the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub stationincluding relaying in same or different position/location complete all as specified and directed. |
| 175 | Laying only serviceable cable obtained from taking out in same or new location or position i.e. in trenches/on walls/floor/roof/ceiling etc of size 2/3/4 core 10 to 35 sqmm including necessarycable lugs, gland etc complete all as specified and directed. |
| 176 | Supply, laying, testing and commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 25 Sq mm 4 Core complete all as specified and directed. |
| 177 | All same as item No. 176 above, but 16 Sq mm 4 Core |
| 178 | All same as item No. 176 herein before, but 10 Sq mm 4 Core |
| 179 | M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10/16sqmm x 4 core cables including testing complete all as specified and directed. |
| 180 | M & L for Repair to street light fitting any type, solar or conventional type in situ by checking for any loose connections, jointing of wires, replacement ofLED drivers/SPD and itssettings, checking forearth continuityand testingcomplete all as specified and directed. Note:- Cost of electronic driver will be measure and paid separately but inclusive of SPD or minor repair to street light and Al/CU Lugs |
| 181 | Supply only electronic driversuitable for LED street light fittings of capacity upto 100 Wattcomplete all as specified and directed. |
| 182 | Supply onlyreplacementof electronic driver suitable for LED street light fittings of capacity above 100 Wattcomplete all as specified and directed. |
| 183 | Supply and fixing in replacement LED street light fitting 120 Watt , input voltage 220-240 V, operating Voltage 120-277 V AC, THD < 10 % , inbuilt surge protection of 10KV, IK 07, lumen efficiency > 120LPW, CCT-5700K with high pressure die cast aluminum hosing and heat resistant with toughened glass and high power LED with secondary optics complete with driver, lamp bracket corrosion resistant including thermal management in multiple optics complete with IP 66, LED Life time 50000 Hr, lens and Optical Cover of Glass protection complete all as specified and directed. |
| 184 | All as per item No. 183 above, but LED street light fitting 90 Watt complete all as specified and directed. |
| 185 | All as per item No. 183 herein before, but LED street light fitting 60 Watt complete all as specified and directed. |
| 186 | S&F in replacement LED Flood lightfitting200 W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection, SPV 10 KV, efficiency 120 LPW, CCT- 5700K suitable for fixing on pole complete all as specified and directed. |
| 187 | All as per item No. 186 above, but LED Flood lightfitting150 W complete all as specified and directed. |
| 188 | S & F in replacement street light junction box made out with SMC material shock and dust proof of size 300 X 200 X 105 mm as per IS and including 30 mm(W) x 3 mm (T) TPN busbar fixed on insulator, 01 No 10 Amps SP MCB, earth termination with nuts and bolts and including 02 nos of flat iron clamps of size 25 x 6 mm, nuts, bolts and washers including two coat of aluminium paint over a coat of primer on exposed steel surface and connecting all incoming and outgoing wires with AL lugs of appropriate size complete all as specified and directed. |
| 189 | Supply & fixing in replacement street light bracket fabricated from 40mm dia medium grade GI pipe bent to shape not exceeding 1.5mtr long with 2 Nos clamps of size 25 x 6 mm flat iron and including nuts, bolts, washers suitable for fixing on poles complete all as specified and directed.Note Cost of clamps will be measured separately under relevant items but cost is inclusive of cost of nut and bolts |
| 190 | Supply & fix in repairs, 20mm dia PVC conduit heavy grade of 6 mtr long from street light bracket to junction box complete all as specified and directed. Note Cost of clamps will be measured separately under relevant items but cost is inclusive of cost of nut and bolts. |
| 191 | M&L in replacement ofclampssuitable for fixing street light /junction box/PVCor GI conduits on pole fabricated from 25 mm x 6 mmflat ironincluding nuts, bolts and washers suitable for fixing on poles including applying twocoat of synthetic enamel paint over a coat of red oxide primeron steel surfaces complete all as specified and directed. |
| 192 | S&F in replacement4 sqmm 4 core PVC insulated flexible copper conductor wire for post top light/garden light/board light drawn through MS pipe/PVC conduit/DWC or as directed complete all as specified and directed. |
| 193 | S&F in replacement2.5 sqmm 3 core PVC insulated flexible copper conductor wire from street light to terminal box drawn through MS pipe/PVC conduit or as indicated in other locations complete all as specified and directed. |
| 194 | S&F in replacement1.5 sqmm 3 core PVC insulated flexible copper conductor wire from street light to terminal box drawn through MS pipe/PVC conduit or as indicated in other locations complete all as specified and directed. |
| 195 | Material and labour for preparation of old painted surface of steel tubular pole of any type 9/11 mtr long for street/security lights, painting with one coat of aluminum paint on entire pole surface including(GI Brackets, clamps and MS cable termination junction box etc.) over one coat of red oxide paint on rusted surface and painting zebra pattern of alternate yellow and black strips withacrylic paint upto 0.9m height from pole coping and writing of pole Number inblack paint on yellow background of dia 100mm dia, painting with one coat of waterproof cement based paintin white colour to pole coping complete all as specified and directed. NOTE : Shades of colour shall be used as per direction of Engineer-in-charge |
| 196 | Material and labour for preparation of old painted surface of steel tubular pole of any type 2.5/3 mtr long for post top/garden lights, painting with two coat of enamel paint on entire pole surface including( clamps and nut bolt etc.) over one coat of red oxide paint and painting with one coat of waterproof cement based paintin white colour to pole coping complete all as specified and directed. NOTE : Shades of colour shall be used as per direction of Engineer-in-charge |
| 197 | S&F in replacement 25 Watt LED decorative post top light fitting of aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, clear cover IP 65 Rating 240V, 50 HZ, AC supply and with all accessories as required complete all as specified and directed. |
| 198 | All as per item No. 197 above, but 15 wattLED decorative post top light fitting complete all as specified and directed. |
| 199 | S&F in replacement 10 Watt LED Bollardlight fitting(1 m), IP 65 Rating, 5700K, lumen efficacy of LED >130 lm/W 240V, 50 HZ AC Supply, having avg life of 50000 hr and housing made of aluminum pipe UV protected pure polyester power coated black after phosphochromate treatment with aluminum heat sink for efficient thermal lighting management sturdiness & excellent corrosion resistant mounting flange of MS sand casting at bottom, clear diffuser for glare free uniform light distribution and electronic driver will in ABS housing with SMPS based constant current supply THD <10 %SPD 3.0 KV (CM & DM) with all accessories as required complete all as specified and directed. |
| 200 | Supply and Fix3 meter decorative hot dipped galvanised mild steel step pole with grey power finish, compatible for post top lantern. Window-plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connection & mounting accessories. window cover to be fitted with allen screws to the pole complete with pole foundation of PCC (1:2:4) and foundation bolt and nuts as per TDS drawing of company complete all as specified and directed. |
| 201 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) |
| 202 | M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in flooring /hard standing finishing the concrete surface as sub base without using extra cement complete all as specified and directed. |
| 203 | M&L for25 cm x 25 cm x 22 mm to 25mm thick Chequered cement concrete tilesin flooring, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shadeincluding 15mm thick Cement mortar (1:6) screed bed or bedding layer of mortar for laying floor tiles complete all as specified and directed. |
| 204 | M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 205 | M&L machine pressed precast concreteinter locking blocks with grey cement and no pigmentany shape and size confirming to IS 15658-2006 of 80 mmm thickness M-40 grade complete all as specified and directed. |
| 206 | Supply and fixing miniature circuit breaker (MCB) SP 6 TO 32 Amps amps amp rating 240V, 10KA \"C\" curve complete with connection testing and commissioning complete all as specified and directed. |
| 207 | Material & labour for earthing with Galvanised Steel earth plate electrode 60cmx 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by BFCfilling all around the earth plate up to 800 mm from bottom of earth plate and electrode connections by usingGalvanised Iron strip 25x4 mmas earthing lead(upto the test point ) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm boreGI pipe connected upto test point and GI pipe light grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 ofSSR 1991(Part-I) complete all as specified and directed. |
| 208 | Supply, fabricate, install, test and commissioning in replacement of Outdoor electrical panel board with double door arrangement for timer switch control of size as per CPRI norms weather proof, dust/ Vermin proof, made out of 3.15 mm thick CRCA sheet, CPRI approved manufacturer, enclosure with 4 Nos mounting stand made up of angle iron frame using 50x50x6 mm,0.5 m height, canopy of adequate size and locking arrangement, duly powder coated, aluminium TPN bus bar 150 Amps with provision of cable entry at bottom, internal control wiring with suitable size of PVC copper cable, cable gland brass copper/ brass lugs, voltmeter, ammeter with CTs, RYB indication lamps and suitable platform 30 cm below GL and 30 cm above GL by using PCC 1:2:4 type B-1 (20 mm graded aggregate) with the following complete all as specified and directed: (i) Power contactor,3 P,100 Amps-01 No. Model MNX 70 of Make L&T or its equivalent in Schneider or Legrand (ii) 4 way connector,75 Amps,415 V-03 Nos.(iii) MCCB 4 P,415 Volts 100 A- 01 No. Make L&T or its equivalent in Schneider or Crompton(iv) Auto/manual toggle switch-01 No.(v) Timer Digital type-01 No.Make : L & T GIC(Cat No :AS2DCDS) or its equivalent in Schneider or Crompton (vi) 0-500 Voltmeter with selector switch - 01 No(vii) 0-200Ammeter with selector switch - 01 No.(Viii) MCB DP 6-32 Amp -01 Nos Make L&T or its equivalent in Schneider or Crompton. (ix) Overvoltage and under voltage relay-01 NoMake L&T or its equivalent in Schneider or Crompton. (x) SPD 3 ph 440 V, 3 P + N, I max-50 KA - 01 no Make L & T cat part no AUSP123PN50D or its equivalent in Schneider or legrand. (ix)LED indicating lamps-1 set of 3 |
| 209 | NOTES :-1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. |
AI Tender Summary
Tender Timeline
Aug 07, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 30, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender