Construction Of Rcc H.L. Bridge In Gamhariya Chowk Raxaulto Gamhariya Chowk Adapur At Ch-4.400 Km
Tender Value
32.50 Crore
Estimated cost
Bid Submission
18 Aug 2025
0 days left
EMD
42.51 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
raxaul → Bihar
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of RCC H.L. Bridge In Gamhariya Chowk RaxaulTo Gamhariya Chowk Adapur At Ch-4.400 Km
BOQ
| Sl. No. | Item Description |
| 1 | Construction Of RCC H.L. Bridge In Gamhariya Chowk RaxaulTo Gamhariya Chowk Adapur At Ch-4.400 Km |
| 2 | H.L. BRIDGE WORK |
| 3 | FOUNDATION |
| 4 | Excavation for Structures |
| 5 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 6 | I. Ordinary Soil |
| 7 | i) Upto 3m depth |
| 8 | Providing and laying of PCC M15 levelling course 100mm thick below the pile cap. |
| 9 | II. PCC Grade M-15 (Levelling Course for Pile Cap) |
| 10 | R.C.C. grade M 35 in Pile Foundation complete as per Dwg & Tech Specification. |
| 11 | Pile Cap in RCC M-35 (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 12 | Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. |
| 13 | II. 1200 mm Dia(UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 14 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 15 | Providing Steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing |
| 16 | Providing and Constructing Temporary Earth Island (Assuming depth of water 1.0 m and height of island to be 1.25 m including Royality for earth |
| 17 | Providing and constructing One Span Service Road to reach island location from one pier location to another pier location including Royality for earth |
| 18 | Carrying out the Confirmatory Boring for Soil Investigation for foundation as per clause 2400 of MORT&H Specification. |
| 19 | Carrying Out Load Testonany pile as per standard procedure laid down in the IS:2911 specification including construction of test cap, dismantling the cap aftertest and cleaning the site and maintaining complete records of load |
| 20 | a) Initial Load Test on test pile for 2.5 times the design load specified in Drawings |
| 21 | 1.2 m Dia Pile |
| 22 | b) Routine pile load test on pile for 1.5 times the design load specified in Drawings |
| 23 | 1.2 m Dia Pile (2% of piles in total). |
| 24 | c) Horizontal pile load test on pile for 1.5 times the design load specified in Drawings |
| 25 | 1.2 m Dia Pile (2% ofpiles in total) . |
| 26 | SUBSTRUCTURE |
| 27 | R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification |
| 28 | i) Upto 5m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 29 | ii) From 5m upto 10m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 30 | R.C.C. grade M-35 in Substructure complete as per Dwg & Tech Specification |
| 31 | RCC M-35 |
| 32 | ii) From 5m upto 10m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 33 | Supplying, fitting and placing HYSD Bar Reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 34 | Supplying,fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. |
| 35 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 36 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 |
| 37 | I) Sandy Material |
| 38 | Providing and laying filter media with granular crushedaggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 |
| 39 | SUPERSTRUCTURE |
| 40 | Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 |
| 41 | II. RCC M-30 (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 42 | Supplying, fitting and placing HYSD Bar Reinforcement (Fe 415) in superstructrue complete as per drawings and technical specification Clauses 1002, 1010 & 1202 |
| 43 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 44 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 45 | Drainage Spouts complete as per drawing and technical specifications Clause 1209 |
| 46 | P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211. |
| 47 | Reinforced Cement Concrete M-30 Grade Approach Slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 |
| 48 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm,complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer\"s instructions for installation.) |
| 49 | Providing & fixing 20 mm thick Compressible Fibre Board in expansion joint complete as per drawing & Technical Specification. |
| 50 | Providing and fixing in position 20 mm thick Premoulded jPJoint Filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm,covered with sealant complete as per drawing and technical specifications. |
| 51 | PROTECTION WORK |
| 52 | Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 53 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 54 | Miscellaneous Work |
| 55 | Providing & Applying 2 coats of water based cement paints to unplastered concrete surface after cleaning the surface of dirt,dust,oil,grease,effloresence and applying paint @ of 1 litre for 2 sqm |
| 56 | APPROCH ROAD |
| 57 | Clearing and Grubbing Road Land ( By manual means)including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees ofgirth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I |
| 58 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . |
| 59 | Construction of Subgrade And Earthen Shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 60 | GSB (G-II) :- Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 61 | WBM Grading 2:- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. |
| 62 | Wet Mix Maccadam:- Providing Laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill) carraige of mixed material by tipper to site,laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100KN weight to achieve the desired density including lighting, barricading and maintainance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 63 | PRIME COAT:- Providing and applying primer coat with Bitumen emulsion (SS-1)on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 64 | TACK COAT:- Providing and applying tack coat with bitumen emulsion (RS ) using emulsion distributor @ 0.25 to 0.30 kg per sq m on the prepared Granular surface cleaned with hydraulic broom as per technical specification clause 503. |
| 65 | Bituminous Macadam:- Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over apreviously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 66 | TACK COAT:- Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 67 | Semi-Dense Bituminous Concrete:- Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects. |
| 68 | Providing and Fixing \"Logo\" of Projectinformayory sign board with Logo as per MORD specifications and drawing.Three MS plates of1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5 m size on back on edges.The lower plate will be welded with MS angle ironframe of25mm x 25mm 5mm.The angle iron frame of the lower mostplate and flat iron frame of middle plate will be welded to 2 Nos.75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600 mm,600 mm,600 below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12SWG steel plate tube.All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc, will be painted with ready mixed synthetic enamer paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 abd Annexure 1700.1. |
| 69 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 |
| 70 | 900 mm equilateral & triangle |
| 71 | 900 mm side octagon |
| 72 | 900 mm x 300 mm,Hazard Marker |
| 73 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface:-Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 74 | Type - A, \"W\" : Metal Beam Crash Barrier:-Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 |
| 75 | DIVERSION |
| 76 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . |
| 77 | Providing and Laying Reinforced Cement Concrete Pipe NP4 as per design in Single Row (1000 MM DIA HPC) |
| 78 | BOULDER PITCHING IN PROTECTION WORK |
| 79 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 80 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9Sand Filling |
| 81 | Providing and laying Boulder pitching on slopes with stone/ Boulder laid over prepared filter media as per drawing and technical specifications Clause 1302 (WIRE CARATED) |
| 82 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 83 | 1% LABOUR CESS |
| 84 | SEIGNOIRAGE FEE |
| 85 | 18% GST |
| 86 | Total Cost for 1st Year Maintenance Work |
| 87 | Total Cost for 2nd Year Maintenance Works |
| 88 | Total Cost for 3rd Year Maintenance Works |
| 89 | Total Cost for 4th Year Maintenance Works |
| 90 | Total Cost for 5th Year Maintenance Works |
| 91 | 1% LABOUR CESS |
| 92 | SEIGNOIRAGE FEE |
| 93 | 18% GST |
| 94 | Construction Of RCC H.L. Bridge In Gamhariya Chowk RaxaulTo Gamhariya Chowk Adapur At Ch-10.270 Km |
| 95 | H.L. BRIDGE WORK |
| 96 | FOUNDATION |
| 97 | Excavation for Structures |
| 98 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 99 | i) Upto 3m depth |
| 100 | Providing and laying of PCC M15 levelling course 100mm thick below the pile cap. |
| 101 | II. PCC Grade M-15 (Levelling Course for Pile Cap) |
| 102 | R.C.C. grade M 35 in Pile Foundation complete as per Dwg & Tech Specification. |
| 103 | Pile Cap in RCC M-35 (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 104 | Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. |
| 105 | II. 1200 mm Dia(UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 106 | Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 107 | Providing Steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing |
| 108 | Providing and Constructing Temporary Earth Island (Assuming depth of water 1.0 m and height of island to be 1.25 m including Royality for earth |
| 109 | Providing and constructing One Span Service Road to reach island location from one pier location to another pier location including Royality for earth |
| 110 | Carrying out the Confirmatory Boring for Soil Investigation for foundation as per clause 2400 of MORT&H Specification. |
| 111 | Carrying Out Load Testonany pile as per standard procedure laid down in the IS:2911 specification including construction of test cap, dismantling the cap aftertest and cleaning the site and maintaining complete records of load |
| 112 | a) Initial Load Test on test pile for 2.5 times the design load specified in Drawings |
| 113 | 1.2 m Dia Pile |
| 114 | b) Routine pile load test on pile for 1.5 times the design load specified in Drawings |
| 115 | 1.2 m Dia Pile (2% of piles in total). |
| 116 | c) Horizontal pile load test on pile for 1.5 times the design load specified in Drawings |
| 117 | 1.2 m Dia Pile (2% ofpiles in total) . |
| 118 | SUBSTRUCTURE |
| 119 | R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification |
| 120 | i) Upto 5m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 121 | ii) From 5m upto 10m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 122 | R.C.C. grade M-35 in Substructure complete as per Dwg & Tech Specification |
| 123 | ii) From 5m upto 10m height (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 124 | Supplying, fitting and placing HYSD Bar Reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 125 | Supplying,fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. |
| 126 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 127 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 |
| 128 | I) Sandy Material |
| 129 | Providing and laying filter media with granular crushedaggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 |
| 130 | SUPERSTRUCTURE |
| 131 | Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 |
| 132 | II. RCC M-30 (UsingBatching Plant, Transit Mixer and Concrete Pump) |
| 133 | Supplying, fitting and placing HYSD Bar Reinforcement (Fe 415) in superstructrue complete as per drawings and technical specification Clauses 1002, 1010 & 1202 |
| 134 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 135 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 136 | Drainage Spouts complete as per drawing and technical specifications Clause 1209 |
| 137 | P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211. |
| 138 | Reinforced Cement Concrete M-30 Grade Approach Slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 |
| 139 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm,complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer\"s instructions for installation.) |
| 140 | Providing & fixing 20 mm thick Compressible Fibre Board in expansion joint complete as per drawing & Technical Specification. |
| 141 | Providing and fixing in position 20 mm thick Premoulded jPJoint Filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm,covered with sealant complete as per drawing and technical specifications. |
| 142 | PROTECTION WORK |
| 143 | Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 |
| 144 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 145 | Miscellaneous Work |
| 146 | Providing & Applying 2 coats of water based cement paints to unplastered concrete surface after cleaning the surface of dirt,dust,oil,grease,effloresence and applying paint @ of 1 litre for 2 sqm |
| 147 | APPROCH ROAD |
| 148 | Clearing and Grubbing Road Land ( By manual means)including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees ofgirth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I |
| 149 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . |
| 150 | Construction of Subgrade And Earthen Shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 151 | GSB (G-II) :- Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 152 | WBM Grading 2:- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. |
| 153 | Wet Mix Maccadam:- Providing Laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill) carraige of mixed material by tipper to site,laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100KN weight to achieve the desired density including lighting, barricading and maintainance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 154 | PRIME COAT:- Providing and applying primer coat with Bitumen emulsion (SS-1)on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 155 | TACK COAT:- Providing and applying tack coat with bitumen emulsion (RS ) using emulsion distributor @ 0.25 to 0.30 kg per sq m on the prepared Granular surface cleaned with hydraulic broom as per technical specification clause 503. |
| 156 | Bituminous Macadam:- Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over apreviously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 157 | TACK COAT:- Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 158 | Semi-Dense Bituminous Concrete:- Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects. |
| 159 | Providing and Fixing \"Logo\" of Projectinformayory sign board with Logo as per MORD specifications and drawing.Three MS plates of1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5 m size on back on edges.The lower plate will be welded with MS angle ironframe of25mm x 25mm 5mm.The angle iron frame of the lower mostplate and flat iron frame of middle plate will be welded to 2 Nos.75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600 mm,600 mm,600 below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12SWG steel plate tube.All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc, will be painted with ready mixed synthetic enamer paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 abd Annexure 1700.1. |
| 160 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 |
| 161 | 900 mm equilateral & triangle |
| 162 | 900 mm side octagon |
| 163 | 900 mm x 300 mm,Hazard Marker |
| 164 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface:-Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 165 | Type - A, \"W\" : Metal Beam Crash Barrier:-Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 |
| 166 | DIVERSION |
| 167 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . |
| 168 | Providing and Laying Reinforced Cement Concrete Pipe NP4 as per design in Single Row (1000 MM DIA HPC) |
| 169 | 1% LABOUR CESS |
| 170 | SEIGNOIRAGE FEE |
| 171 | 18% GST |
| 172 | Total Cost for 1st Year Maintenance Work |
| 173 | Total Cost for 2nd Year Maintenance Works |
| 174 | Total Cost for 3rd Year Maintenance Works |
| 175 | Total Cost for 4th Year Maintenance Works |
| 176 | Total Cost for 5th Year Maintenance Works |
| 177 | 1% LABOUR CESS |
| 178 | SEIGNOIRAGE FEE |
| 179 | 18% GST |
| 180 | Gamhariya Chowk Raxaul To Gamhariya Chowk Adapur |
| 181 | Clearing and Grubbing :- Clearing and Grubbing Road Land (By manual means)including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees ofgirth upto 300mm, removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification clause 201.1 and direction of E/I |
| 182 | Scarifying :- Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. |
| 183 | Dismantling of Cement Concrete Pavements :- Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately |
| 184 | Box Culvert :- Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 |
| 185 | Construction of embankment with approved material deposited from road way cutting and excavation from drain and foundation of other structures and excavated with an average lead of 100 m graded and compacted to meet requirement of tables 300.1 and 300.2 as per technical specification clause 301.5 |
| 186 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m & 100 m as per Technical Specification Clause 301.5 . |
| 187 | For 1000 M Lead |
| 188 | For 100 M Lead |
| 189 | Construction of Subgrade And Earthen Shoulders :- Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 190 | Granular Sub-base with Well Graded Material(Grade II) :- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 191 | Water Bound Macadam with Stone Screening Gr-II :- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. |
| 192 | Water Bound Macadam Gr III :- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 193 | Wet Mix Macadam (WMM) :- Providing Laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill) carraige of mixed material by tipper to site,laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100KN weight to achieve the desired density including lighting, barricading and maintainance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 194 | Prime Coat :- Providing and applying primer coat with Bitumen emulsion (SS-1)on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 195 | Tack Coat :- Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surface tretaed with Primer and clened with hydriloc broom as per technical specification aclouse 503. |
| 196 | Bituminous Macadam :- Providing and laying bituminous macadam with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over apreviously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 197 | Tack Coat :- Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 198 | Semi Dense Bituminous Concrete :- Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects. |
| 199 | Pavement Quality Concrete (PQC) :- Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing |
| 200 | Reinforced cement concrete M15 grade kilometre local stone of standard design asper IRC:8 fixing in position including painting and printing , etc as per drawing and technical specification clause 1703. |
| 201 | 5th km stone |
| 202 | Km stone |
| 203 | 200 m stone |
| 204 | Retro-reflectorised Traffic SignsProviding and erecting direction and place identification retro-\reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos.firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. |
| 205 | Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 |
| 206 | Road Markers/Road Stud with Lens Reflector :- Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973. |
| 207 | Road Delineators :- Supplying and installation of delineators (Road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC- 79 and the drawings. |
| 208 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 |
| 209 | 600 mm equilateral & triangle |
| 210 | 600 mm circular |
| 211 | 600 mm x 450 mm rectangular |
| 212 | 900 mm x 300 mm,Hazard Marker |
| 213 | 900 mm side octagon |
| 214 | Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 |
| 215 | Planting of Trees and their Maintenance for one Year :- Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year |
| 216 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 217 | At Edgefor BT Portion |
| 218 | Pedestrian Crossing(2 m in length and providing at 50 cm apart) |
| 219 | At Edgefor New & Old CC Portion |
| 220 | Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 221 | PARAPET REPAIR |
| 222 | R.C.C. grade M 25Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 223 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 224 | R.C.C. grade M 30Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 225 | Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 226 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 227 | M-20Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 228 | 300MM Irrigation Pipe |
| 229 | Providing and laying of a reinforced cement concrete pipe duct,300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:981997,bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. |
| 230 | 1% LABOUR CESS |
| 231 | Seigniorage Fee |
| 232 | 18 % GST |
| 233 | 6 YEAR MAINTENANCE COST |
| 234 | 1% LABOUR CESS |
| 235 | Seigniorage Fee |
| 236 | 18 % GST |
| 237 | Renewal Coat |
| 238 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.25kg per sqm on the prepared granular surface tretaed with Primer and clened with hydriloc broom as per technical specification aclouse 503. |
| 239 | Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects. |
| 240 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 241 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 242 | 1% LABOUR CESS |
| 243 | Seigniorage Fee |
| 244 | 18 % GST |
AI Tender Summary
Tender Timeline
Aug 07, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedAug 18, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 18, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender