Tender For Certain Repair To Geyser, Fans And Other Misc Items At Af Stn Awantipur, Pulwama-Jammu And Kashmir

Military Engineer Services has published Tender For Certain Repair To Geyser, Fans And Other Misc Items At Af Stn Awantipur. Submission Date for this Tender is 05-09-2025. Ceiling Fan Tenders in Pulwama Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50573575
Corrigendum : Tender For Certain Repair To Geyser, Fans And Other Misc Items At Af Stn Awantipur
Tender
Indian
Jammu And Kashmir
Pulwama
05-09-2025

Tender Details

Tender For Certain Repair To Geyser, Fans And Other Misc Items At Af Stn Awantipur; 1 Taking down carefully electric geyser of any type and capacity complete opening of the geyser and replacing the defective parts including disconnecting electric and water supply connection and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed by Engineer -in-Charge.Note :-Any accessories found unserviceable that shall be replaced under respective items of this Sch 2 Supply only, syphon assembly with rubber gasket, including nuts, bolts, washers etc of following capacity geysers:- 3 (a)50 Ltrs capacity geysers. 4 (b)35 Ltrs capacity geysers. 5 (c)25 Ltrs capacity geysers. 6 Supply and fixing in repairs 15mm bore GI tubing , medium grade, with all fitting fixed to wall and flores etc , making holes, complete all as specified and directed by Engineer -in-Charge .Make:Tata/Prakash Surya/Jindal. 7 Supply only inner tank, vessel made of MSsheet 22 gauge all as specified and directed by Engineer-in-ChargeISI marked factory madefor suitable pressure following capacity:- 8 (a)50 Ltrs capacity . 9 (b)35 Ltrs capacity. 10 (c)25 Ltrs capacity. 11 Supply and fixing of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed by Engineer-in-Charge Make-Microne/Globo. 12 All as per srl item No-05 above but capacity 2 KW. 13 All as per srl item No-05 above but capacity 3 KW. 14 Supply onlyglass wool heat insulation superior quality suitable for geyser of capacity 25/35/50 Ltrs. 15 Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. 16 Supply and fixing of PVC insulated shethed cable 3 core flexible copper conductor of size 2.5 sqmm fire proof make:Havells/Gloster/Polycab 17 Supply and fixing of drain plug for geyser. 18 Supply and fixing of safety valve for geyser. 19 Supply and fixing of indicator lamp for geyser of any type as per existing in geyser. 20 Supply and fixing of thermostat switch suitable for 50/35/25 ltrs capacity geysers as per sample. 21 Supply and fixing of push type thermostat switch suitable for 50/35/25 ltrs capacity geysers as per sample. 22 M&L for spray painting to water heather of capacity25 Ltrs to 50 Ltrs capacity by spraying two coats of synthetic enamel paint after filling cavities with filler and cleaning dust etc complete all as specified and directedby Engineer –in-Charge incl writing MES number. 23 Taking down existing unserviceable outer cover and supply and fix new outer cover of geyser capacity 25 Ltrs complete all as specified and directed by Engineer–in-Charge. 24 All as per Srl item No 16 above but capacity 50 ltrs. 25 Taking down unserviceable bottom cover plates (2 half) and supply and fix with new bottom cover plates with machine columns of geyser of capacity 25/50 Ltrs. 26 Supply and fix in replacement MCB single pole 240 volts any rating from 20 amps, with rupturing capacity 10 KA, class c ,including providing thimble for out going cables. Make:- Legrand(DX 3 )/ Siemens (Betagard)/Schneider (Acti-9) 27 S&F of PVC connection mesh type for cold/Hot water as per sample . Complete all as specified and directed by Engineer-in-Charge 28 S&F 15 Amps three pin socket suitable for metal clad Make-Schenider/Legrand/Hagger 29 S&F 15 Amps three pin Top suitable for metal clad Make-Schenider/Legrand/Hagger 30 S&F stop valve cast copper alloy screwed down with butterfly or crunch handle of size 15mm bore ISI marked. All as directed and specified by Engr-in-charge Make :- Neta, Jindal, Gem, Parko 31 S&F single pole and nuetral enclosure with two pin and earth plug and socket completewith one single pole MCB up to 20 Amp ,240 Volts complete. 32 Replacement of old unserviceable anchor bolt with anchor bolt 12mm 100mm long complete all as specified and directed (Note- Achor bolt shall be grouted with hammer drill only). 33 Disconnecting electrically dismantling and taking out electric energy meter any type and capacity and depositing to MES Store Yard complete all as specified and directed . 34 Repair to electronic energy meter single phase/three phase up to 60 Amps after disconeeting proper electric coneection from main board and refixing in same or other location incl sealing properlead seals and wires as required complete all as specified and directed . 35 S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 1.5 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 1.5 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. 36 S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. 37 S&F in replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. 38 Supply and fixing in replacement Meter box IP-65 for 3 meters with triangular locks of size 300x450x170 mm transparent LID of Cat part No Mi 0400 T of Hensel or equivelent to HPL /Indoasian includingcutting and chases wall and removing old metal or wooden box and fitted new box and match the disturbed surface with existing specification by required PCC andplastering workall as per directed . 39 S&F in replacement of sheet metal enclosure DB SPN 2 way, single door, 230 volts AC, surface mounting complete for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.(For Bldg Security light) 40 S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.Make: Havells/L&T/Legrand 41 S&F in replacement of sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SP as outgoing complete all as specified. 42 S&F in replacement of MCBs, SP, 6-32 Amps, 230 volts,10 kA rupturing capacity, B curve type complete all as specified. Make : L&T/Havells/ABB 43 S&F in replacement of MCBs, SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified. 44 S&F in replacement of MCBs, TPN, 40-100 Amps, 415 volts, 10 kA rupturing capacity, C curve type complete all as specified. 45 S&F in replacement offan capacitor with wire terminals of capacity 2.5 Mfd, 230 volts AC all as specified. 46 S&F in replacement of fan capacitor with wire terminals of capacity 3.15 Mfd, 230 volts AC all as specified. 47 S&F in replacement of fan capacitor with wire terminals of capacity 4.0 Mfd, 230 volts AC all as specified. 48 S&F in replacement of rubber reel suitablefor ceiling fan/Ex fan/cabin fan of any type/make/size all as specified. 49 S&F in replacement of down rod of 1 height fabricated out of MS pipe 10 mm dia heavy duty duly painted with white paint suitable to hang ceiling fan of any description, make and model complete all as specified. 50 S&F only in replacement of heavy gauge ceiling fan hanging clamp fabricated out of MS flat with nut bolts with split pins complete all as specified 51 M&L for overhauling of fan of any type and any make by opening, cleaning, greasing, oiling of fan motor after testing the faults including replacement of minor parts and re-assembling complete all as specified.(Note: Spare parts & winding shall be measured and paid separately). 52 S&F in replacement of ball bearing suilable for ceiling/ exhaust/ cabin/ wall/ pedestrial fan of any type/ make/ size all as specified. 53 S&F in replacement of bush suitable for ceiling/ exhaust/ cabin/ wall/ pedestrial fan of any type/ make/ size including namda if required all as specified. 54 S&F in replacement Fan dimmer 6electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd and as specified and directed. 55 Transportation of rotor of fan to work shop for rewinding/repair work and returning back to site complete all as specified.(Note:- Rewinding will be measured and paid separately.) 56 M&L for removing old/burnt winding, cleaning of slots/pitches by using cleaning material by removing the insulating materials and then rewinding (i.e renewal of winding) the fans with appropriate/same gauge of super enamelled copper wire and insulating material, varnishing, drying the winding for adequate periodto remove the moisture content and strengthening the winding and testing to the speed and flow of the fans any make all as specified for the following type of fans:-(a)Ceiling fan 1200/1400 mm sweep 57 (b)Exhaust fan 300/380/450 mm sweep 58 (c)Wall mounted/cabin fan 400/450 mm sweep 59 S&F in replacement of fan blades heavy duty of any make suitable for exsiting pattern and colour scheme including screws all as specified for following type of fans:-(a)Ceiling fan 1200/1400 mm sweep (set of three blades) 60 (b)Exhaust fan 300/380/450 mm sweep 61 (c)Wall mounted/cabin fan 400/450 mm sweep 62 (d)Pedestal fan 400/450mm sweep 63 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed 64 S&F of Ceiling fan canopy made up of plastic of desired colour complete with taking down the Fan and reinstall after fixing of canopy to the Fan complete all as specified and as directed. 65 M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified. 66 S&F earth continuity conductor or main earthing lead fixed to wall on batten or reccess or chases or burid in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or as required of size 4 mm dia galvanised iron wire complete all as specified. 67 S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Complete all as specified and as directed. 68 S&F in replacement LED Building security light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete. Complete all as specified and as directed. 69 Supply and fixing GI Bracket bent to shape fabricated with GI Pipe 40mm dia light grade 1.5m long including mounting clamps nut bolts complete all as specified and directed. 70 Note:-An amount of Rs. 20,149.50 on account of credit schdule for Sch A Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 29-08-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-09-2025

Key Value

Document Fees
INR 500 /-
Tender Value
INR 20 Lakhs /-