| 1 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63mm & ID-51 mm nominal) |
| 2 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90mm & ID-76 mm nominal) |
| 3 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including xcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63mm & ID-51 mm nominal) |
| 4 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including xcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90mm & ID-76 mm nominal) |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 Sqm |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 50 sq.mm |
| 7 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 9 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 11 | Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required. 4 Core 16 Sq.mm |
| 12 | Supplying and laying of following size XPLE insulated, armoured, power cable of 1.1 KV grade, duly ISI marked, with Aluminium conductor, confirming to IS: 7098 (Part-I) in existing RCC / HUME / GI / DWC HDPE pipe, as required.3.5 Core 35 Sqmm |
| 13 | Supply and errection of 8.0 meter nominal height Galvanized octagonal pole (As per BS EN ISO 1461) bottom 130 mm made up of3mm thick sheet including foundation bolts, having 1 No. single arm bracket 1 meter long suitable for fixing the existing LED light fittings with clamps, making foundation with grade M20/25 RCC and Fe 415 grade reoforcement (500mm x 500mm x 900mm), GI base plate, GI anchor plate, MS canopy etc as required. Having a junction/looping box complete with 10 Amps, 10 KA DP MCB, Screw less DIN mounting Connectors suitable for 16/25 Sqmm terminations complete with DIN bar, shorting links, end locks etc as required. |
| 14 | Supplying, installation, testing & commissioning of 45 Watt street light fitting in pressure die cast aluminium body with toughened glass/PC cover, colour temperature 5700-6500K, minimum IP65 protection, High Power LED with system efficacy> 1101m/W, PF>0.95, THD <10% at full load, CRI>70, Avg life class 50000Hours @ L70, with in built driver set, surge protection 4KV or more, operating voltage 150-270Volts i/c making connection with 1.5 Sqmm FRLS PVC insulated copper conducter single core cable and earthing, testing etc as required. |
| 15 | Supply and errection of 8.0 meter nominal height Galvanized octagonal pole (As per BS EN ISO 1461) bottom 130 mm made up of3mm thick sheet including foundation bolts, having 1 No. Y shape double arm bracket of size of 2.2 meter long suitable for fixing the existing LED light fittings with clamps, making foundation with grade M20/25 RCC and Fe 415 grade reoforcement (500mm x 500mm x 900mm), GI base plate, GI anchor plate, MS canopy etc as required. Having a junction/looping box complete with 10 Amps, 10 KA DP MCB, Screw less DIN mounting Connectors suitable for 16/25 Sqmm terminations complete with DIN bar, shorting links, end locks etc as required. |
| 16 | Supplying, installation, testing & commissioning of 45 Watt street light fitting in pressure die cast aluminium body with toughened glass/PC cover, colour temperature 5700-6500K, minimum IP65 protection, High Power LED with system efficacy> 1101m/W, PF>0.95, THD <10% at full load, CRI>70, Avg life class 50000Hours @ L70, with in built driver set, surge protection 4KV or more, operating voltage 150-270Volts i/c making connection with 1.5 Sqmm FRLS PVC insulated copper conducter single core cable and earthing, testing etc as required. |
| 17 | Supplying, installation, testing & commissioning of power coated factory assembled hut type double door, both side openable floor monted pitdoor feeder pillar suitable for 3 phase, 4 wire 415 Volt AC supply and of following sizes, fabri cated out of 2mm thick CRCA sheet tapered, drip proof, top extended 100mm on all sides including 50mm x 50mm x 5mm MS angle iron base frame duly welded with 4 no\"s legs for grouting in cement concrete 1:3:6 (1 cement, 3 coarse Sand, 6 grouted stone aggregate of 40mm nominal size) foundation (300mm abouve the ground lebvel) all around, earthing studs and detachable individual gland plates for each cable andwith the following mountings/accessories & having individual compartment for switch gear etc. duly connection and inter connection and painting with epoxy based primer and two coats of epoxy paint of approved shade complete with loking arragement etc. as required. (Street Light Feeder Pillar). Minimum front surface area not less than 1.5 Sqmtr & 450mm deep) |