Tender For Electrical Work Under Beautification/Strengthening Of Rashtriya Dalit Prerna Sthal And Green Garden, Noida. - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., All kinds of soil. 2 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). 4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:, Cement mortar 1:4 (1 cement : 4 coarse sand) 5 12 mm cement plaster of mix :, 1:4 (1 cement: 4 fine sand) 6 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels., Granite stone slab all colour and texture except black, Cherry/ Ruby red, Area of slab over 0.50 sqm 7 Supply and fixing 3 seater metal benches should be designed as per the aesthetics and theme of the city with Cast iron arm rests and stand, with sitting base made up of Mild Steel, the bench should be powder coated to prevent corrosion and rusting duly fixed and grouted on the ground. 8 Providing and fixing pair of Stainless Steel dustbins 100 litre volume, set of two different colours, for dry and wet waste, and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete. 9 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 35 sq. mm 3-1/2 core 10 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 120 sq. mm 3-1/2 core 11 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., 300 sq. mm 3-1/2 core 12 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 10 sq. mm 4 core 13 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 35 sq. mm 3-1/2 core 14 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 70 sq. mm 3-1/2 core 15 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 10 sq. mm 16 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 16 sq. mm 17 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 35 sq. mm 18 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 70 sq. mm 19 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 120 sq. mm 20 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 150 sq. mm 21 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge., 300 sq. mm 22 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 120 sq. mm 3-1/2 core 23 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge., 300 sq. mm 3-1/2 core 24 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 25 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. 26 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. 27 Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. 28 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 29 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 30 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 31 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 32 Repair of two old fountains, SITC of Fountain comprising of 28 nos. Aerating Jets fitted on 4 nos. rings of 2m día each. Each Aerating Jet Nozzle made of Brass-Chrome plated fitted with a Brass BJRC for directional adjustments, a gunmetal ISI mark wheel valve & necessary fittings. Water Spout from 8 Nos. Elephants Trunk at lowermost level. Trickling Waterfall/Cascading from all saucer-shaped structures. Rings, pipework & manifolds made from AISI 304 standard stainless steel with necessary accessories. Approx. height of water effects of Aerating Jets: 1.5m. (2 set) SITC of Monoblock type submersible pump set of Following Capacity (Three phase, 50Hz, 415-380V AC) with proper completion of work as per direction of E/Ic. Pump: Kirloskar/Crompton Greaves Make. Suction filter for each pump: Filter body & filter mesh made from AISI 304 standard stainless steel. 5 HP (12 Nos) Fountains & Waterfall/Cascadings Electrical Outdoor Panel (Body made from 16 gauge MS Sheet- Powder Coated): SITC of specialised Outdoor type Electric panel for fountain & Waterfall/Cascading which includes control arrangement for fountains & Waterfall/Cascadings pumpset and RGB/White/Warm White lights comprises of: 1. Contactor 25 Amp-06 Nos 2. Single Phase Preventer-06 Nos 3. Incomer Main Switch 100 Amp-01 Nos 4. Overload Relay 6-18 Amp-06 Nos 5. MCB for motor 32 Amp-06 Nos 6. MCB for Lights 6 Amp -01 Nos 7. Push Button On/Off switches (Red/Green)- 06 Nos. 8. Overload Indicator - 06 Nos 9. Single Phase Indicator-06 Nos 10. 3 Phase indicator RGB-01 Nos 11. Voltmeter-01 Nos. 12. Ampere Meter- 06 Nos (Total 2 set) Waterproof Lights for Fountains & Waterfall/Cascading:A SITC of waterpro of 12V LED lights (RGB/White/Warm White). Complete light body, stainless steel, total 27 watt power leds. Toughened glass with seal. stainless steel cable gland. All external nuts and bolts are of stainless steel. Adjustable mounting bracket is made of stainless steel (all component of AISI 304 standard). IP 68 compliant. Light complete with clamp, waterproof hardener & epoxy. All in pool connections shall be fully waterproof. 130 Nos SITC of waterproof LED lights Sequencer-2Nos Cables: A Providing & laying of 1.1 kV grade double insulated copper flexible cable 1.5 sq.mm x 4 core for lights, (1000 Mtr) B Providing & laying of 1.1 kV grade double insulated copper flexible cable 2.5 sq.mm x 3 core for pumps, (700 Mtr) 6 Earthing of Fountains electrical panel-4 Nos 33 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work, 40 mm dia. nominal bore 34 Providing, laying and fixing following dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required., 100 mm dia 35 Providing, laying and fixing following dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required., 150 mm dia 36 Providing, laying and fixing following dia RCC pipe NP2 class light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement: 2 fine sand) including trenching (75 cm deep) and refilling etc as required., 150 mm dia 37 Providing, laying and fixing following dia RCC pipe NP2 class light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement: 2 fine sand) including trenching (75 cm deep) and refilling etc as required., 100 mm dia 38 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., 63 mm dia (CD-63 mm & ID-51 mm nominal) 39 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., 160 mm dia (CD-160 mm & ID-135 mm nominal) 40 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required., 150 mm width X 50 mm depth X 1.6 mm thickness 41 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required., 300 mm width X 50 mm depth X 1.6 mm thickness 42 Supplying, erecting, testing and commissioning outdoor duty floor mounted weather proof IP66 feeder pillar fabricated as detailed above but with double door (lockable outer door), sloping roof, water run-off gutter on three sides as per approved drawing, entire unit mounted on 50mm x 50mm x 6mm angle iron with minimum 300mm long legs: Feeder Pillar 1 Incomer: 1nos 63A TPN MCB 2 set of three phase indicating lamps with suitable protection. Busbar: Equally sized three phase and neutral copper conductors busbar suitably sized to carry 100A current and suitably insulated with colour coded Heat Shrink Sleeve. Outgoings: 2nos 25A TP Contactor each with set of 6nos 10A SPN MCBs 2nos 24 Hour Timer with auxiliary contacts to close above contactor. 4nos 10A TP MCB 43 Incomer: 1nos 40A TPN MCB 2 set of three phase indicating lamps with suitable protection. Busbar: Equally sized three phase and neutral copper conductors busbar suitably sized to carry 100A current and suitably insulated with colour coded Heat Shrink Sleeve. Outgoings: 2nos 25A TP Contactor each with set of 9nos 10A SPN MCBs 2nos 24 Hour Timer with auxiliary contacts to close above contactor. 4nos 10A TP MCB 44 Incomer: 1nos 40A FP isolator Outgoings: 3nos 40A DP ELCB 18nos 6/10/16A SP MCB 45 Supply and laying of Copper conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected (4c x10sqmm) with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 46 Supply and laying of Copper conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected (4c x10sqmm) with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (4cx4 sqmm) 47 Supply and laying of Copper conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected (4c x10sqmm) with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (3c x 2.5 sqmm) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., 90 mm dia (CD-90 mm & ID-76 mm nominal) 49 Repairing of 500 KVA DG set panel as per direction of Engineer in charge 50 Repairing of Existing L.T. Panel as per direction of Engineer in charge 51 Dismantling of Existing Electrical work as per direction of Engineer in charge 52 Supplying, installation, testing and commissioning of Decorative pole shall be made of Mild Steel 6mtr height with die cast embellishments and Single arms decorative bracket of predefined design to hold drop down the street light of 90W . Pole shall be made out of Mild Steel Pipe having 60mmx3mmx1000mm at Top ,76mmx3.2mmx4000 mid and 1000X114mm bottom base with decorative cast base plate including plinth as per requirement of size. Light fixture shall be made of die cast aluminium with light dia 697X480mm. The complete fixture gives a royal finish of the tradition era. Pole having Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation as per direction of Electrical standard. Entire Pole, light and decorative brackets should be painted with proper zinc primer and Polyurethane powder coat/paint Pole is inclusive of 90 watt LED Post top with luminous flux 5400lm, luminaire efficacy 90lm/w, IP65, CCT:3000K/4000K/6000K as required by project, CRI>70, Maintenance of lumen 50,000hrs. @L70, operating temp. 0 to +40°C, Input voltage 140 to 270VAC, 50Hz. The decorative pole is suitable for outdoor lighting application. Pole is complete in all aspects with all accessories 53 SITC of Decorative pole shall be made of Mild Steel 6mtr height with die cast embellishments and Single arms decorative bracket of predefined design to hold drop down the street light of 60W . Pole shall be made out of Mild Steel Pipe having 60mmx3mmx1000mm at Top ,76mmx3.2mmx4000 mid and 1000X114mm bottom base with decorative cast base plate including plinth as per requirement of size Light fixture shall be made of die cast aluminium with light dia 697X480mm. The complete fixture gives a royal finish of the tradition era. Pole having Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation as per direction of Electrical standard. Entire Pole, light and decorative brackets should be painted with proper zinc primer and Polyurethane powder coat/paint Pole is inclusive of 60 watt LED Post top with luminous flux 5400lm, luminaire efficacy 90lm/w, IP65, CCT:3000K/4000K/6000K as required by project, CRI>70, Maintenance of lumen 50,000hrs. @L70, operating temp. 0 to +40°C, Input voltage 140 to 270VAC, 50Hz. The decorative pole is suitable for outdoor lighting application. Pole is complete in all aspects with all accessories. 54 Supplying, installation, testing and commissioning of Decorative pole shall be made of Mild Steel 6mtr height with die cast embellishments and double arms decorative bracket of predefined design to hold drop down the street light of 90W each . Pole shall be made out of Mild Steel Pipe having 60mmx3mmx1000mm at Top ,76mmx3.2mmx4000 mid and 1000X114mm bottom base with decorative cast base plate including plinth as per requirement. Light fixture shall be made of die cast aluminium with light dia 697X480mm. The complete fixture gives a royal finish of the tradition era. Pole having Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation as per direction of Electrical standard. Entire Pole, light and decorative brackets should be painted with proper zinc primer and Polyurethane powder coat/paint Pole is inclusive of 90 watt LED Post top with luminous flux 5400lm, luminaire efficacy 90lm/w, IP65, CCT:3000K/4000K/6000K as required by project, CRI>70, Maintenance of lumen 50,000hrs. @L70, operating temp. 0 to +40°C, Input voltage 140 to 270VAC, 50Hz. The decorative pole is suitable for outdoor lighting application. Pole is complete in all aspects with all accessories . 55 Supply of installation Diamond RGB LED light made of Stainless steel and have ingress protection of IP65 for optical compartment. Light Fixture of size 900x900mm above ground level with RBG spot light of 50W for 360-degree illumination from predesigned pattern on the surroundings with noticeable mode. All section Shall be welded using high and MIG welding process. Service door shall be provided at upper part of the fixture which equipped with a C clamp with sliding nuts to accommodate a built-in connection box. Fitting made of SS with fine laser cut design tailored with lighting. Diffused symmetric light without glare. Light output of source more than 110lm/ watt, system support Surge protection 4k, operating voltage 140-270V, wired with Branded LEDs and equivalent constant current driver with efficiency>85%, power factor>0.9, THD<=10%. CCT of led will be 3000/4000/5000/RGB as required by the project. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. 56 Supplying, installation, testing and commissioning of 46W 12 pcs Multi-LEDs Inground Lighting Fixture with LED Colour Temperature : 3200K , Operating Temperature : -10°C~+50°C, Input Power should be AC100~240V, Standard Optics - 16°, Controllable Section - 2, Ingress Protection - IP67, Impact Protection - IK10, Control Protocol - DMX + RDM, BIS 57 SITC of 40W ww Source Wash Light with the Following Specification : Max Power - 40W, Voltage - AC100~240V, Minimum Light efficiency (lm/W) > 45 lm/w, Standard Optical System - 12°/30°/45°/60°/12*50°/15*50°, LED Colour Temperature : 3200K , Operating Temperature : - 10°C~+50°C Fast Colour Pickup - 24 In-Built Presets, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDM, 58 SITC of 200W WW Source Wash Light with the Following Specification : Max Power - 200W, Voltage - AC100~240V, LED Colour Temperature : 3200K ,Minimum Light efficiency (lm/W) > 66 lm/w, Operating Temperature : -10°C~+50°C, Standard Optical System -12°/30°/45°/60°/12*50°/15*50°, Dimming - 24Bit, with, Fast Colour Pickup - 24 In-Built Presets, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDM , BIS, 59 SITC of 400 WW Source Wash Light with the Following Specification : Max Power - 400W, Voltage - AC100~240V, LED Colour Temperature : 3200K ,Minimum Light efficiency (lm/W) > 66 lm/w, Operating Temperature : -10°C~+50°C, Standard Optical System -12°/30°/45°/60°/12*50°/15*50°, Dimming - 24Bit, with, Fast Colour Pickup - 24 In-Built Presets, Impact Projection - IK10, Ingress Protection - IP67, Protocol - DMX + RDM , BIS, 60 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead., For thickness of tiles above 25 mm and up to 40 mm 61 Operation and Maintenance of 1st year (0.5%) 62 Operation and Maintenance of 2nd year (1%) 63 Operation and Maintenance of 3rd year (1.5%) 64 Operation and Maintenance of 4th year (2%) 65 Operation and Maintenance of 5th year (2.5%)