| Sl. No. | Item Description |
| 1 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavating over areas, n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L for Plain cementconcrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation/mass concrete complete all as specified and directed. |
| 6 | M&L for RCC (nominal mix) type B-1, 1:2:4 using 20 mm graded stone aggregate) inrafts, footings, foundation beams, Plith beams, bases for columns etc basement slabs, under - reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L for RCC (nominal mix) type B-1, 1:2:4 using 20 mm graded stone aggregate) in columns, Piller, Piers, post and structs etc basement slabs,under - reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L forRCC (nominal mix) type B-1, 1:2:4 in using 20 mm graded stone aggregate Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and inshelves and the like complete all as specified and directed. |
| 9 | RCC (nominal mix) in using 20 mm graded stone aggregateincluding Beams, Cantilevers, brussesmers, lintels over 1.5 m span etc complete all as specified and directed. |
| 10 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed. |
| 11 | Formwork to sides of pillars, posts, struts, piers, columnsand stanchions for fair finish surfaces in rectangular, square or pentagolnal complete all as specified and directed. |
| 12 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed. |
| 13 | Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc also splays between floors and beams etc complete all as specified and directed. |
| 14 | M&L forPolythene film black 50mm micron applied Bitumen blown any grade appled hot, two coats, to concrete surfaces at the rate of 1.5 Kg/ Sqm per coat complete all as specified and directed. |
| 15 | M&L for TMTmild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | All as per item No 15 here in before but 6-8 mm dia and over as in stirrups,spacers and binder etc complete all as specified and directed. |
| 17 | M&L for Brick Masonry with subclass \"B\" bricks, straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 18 | M&L for Rendering 15mm thick in cement mortar 1:6 on fair faces of brickwork or concrete sur faces even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brickwork or concrete sur faces even and smooth without using extra cement with using water proofing compound complete all as specified and directed. |
| 20 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 21 | M&L for Moorum/red bajri filling in floors or paving, laid in layers n.exc 15 cm thick, spread,levelled and rammed including watering complete all as specified and directed. |
| 22 | M&L for broken stone or boulder hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 23 | M&L for 75 mm thick Plain cementconcrete 1:3:6 type C2 using 40mm graded stone aggregate as sub base/ Plinth Protector complete all as specified and directed. |
| 24 | M&L for 100 mm thick Plain cementconcrete 1:3:6 type C2 using 40mm graded stone aggregate as sub bases, sub floors/ paving complete all as specified and directed. |
| 25 | M&L for 100 mm thick Plain cementconcrete 1:2:4 type C2 using 40mm graded stone aggregate as sub bases, sub floors /paving complete all as specified and directed. |
| 26 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 27 | M&L for Preparation of newly plastered surfaces of Wall and applying Threecoats of White washingover a coat of Chalk Whiting complete all as specified and directed. |
| 28 | M&L for surface walltwo coat cement paint over priming plastered and other surfaces with alkali-resistant paint complete all as specified and directed. |
| 29 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 30 | M&L for Endura tiles 8 to 10 mm thick (square /rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm, in foot path etc complete all as specified and directed. |
| 31 | M&L for 100 mm thick Plain cementconcrete 1:4:8 type C2 using 40mm graded stone aggregate as sub bases,sub floors/ paving complete all as specified and directed. |
| 32 | M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:4 under the endura tiles complete all as specified and directed. |
| 33 | M&L for reinforced concrete pipes, class NP3 in 450mm bore of pipe, laid and joint complete with collars complete all as specified and directed. |
| 34 | M&L for provideed,cement concrete type B1 1:2:4 using 20mm graded stone aggregate in roof kerb or mud stops, rounded or chamfered on edgein lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 35 | Taking down existing unserviceableroof treatment of any description including cement plaster, any thickness from roof surface ,cleaning of roof surface and preparaing it for further treatmentand removing the debries / rubbish material from site complete all as specified and directed. |
| 36 | M&L for preparation of plastered/concrete surfaces of Bldg roofs & tarraces,parapets, sunshades and exterior wallsby brushing/brooming/blowing and applying HS Roof Kool & Seal fibre reinforeced liquid applied elastomeric waterproofing membrane, impregneated with nano-fibre and formulated with PU-Acrylic Hybrid Polymer complete all as specified and directed.Method of Application:-The surface to be applied should be clean & sound ,free from any kind of contamination, dirt, tar/bitumen coating etc. Oil & Greese must be removed using degreasing solvents.Any damaged surface must be repaired by using crack fillers or polymer modified repair mortar using ADVANCED LATES PLUS as per Manufacture direction.Angular fillets-Hampering of junction of any right -angled corner( 50mm x50mm) & repairing the same using polymer modified mortar in1:4 ratio (cement sand) admixed withHS Advanced Latex Plus @3% by weight of cement.Application of Primer:- Providing and applying single coat of HS PU Roof Kool& seal using brush/ roller after diluting the water in 40% ratio by volume (as per manufactures specification ) as the primer coat .Allow the primer to dry for 3-4 hours prior to waterproofing coating application.Application of HS Roof Kool & Seal :- providing and applying two coats of HS Roof kool & Seal (Non -diluted )up to verticalwall 300 mm. Retention 4-5 hours. One component water based ,high soild, UV resistant hybrid Polyurethanemembrane with 300% elongation,as per ASTM D412, for long lasting waterproofing SRI 107. |
| 37 | HORIZANTAL WATERPROOFING: (By using :-HS Roof Kool & Seal Product)Stage Dliution ToolInter coat periodForced coverage (Compressive system)Self priming40% withHard brush3-4 Hrspotable water/ RollerWater proofingUndiluted -4-6 Hrs 1.0-1.1 Sqm/ltr 1st coat (for 03 coats application)Water proofingUndiluted -4-6 Hrs 1.0-1.1 Sqm/ltr 2nd coat (for 03 coats application)The cured applied system shall achieve a total dry film thickness of 450-500 microns.VERTICAL WATERPROOFING:- (By using :-HS Roof Kool & Seal Product)Stage Dliution ToolInter coat periodForced coverage (Compressive system)Self priming50% withHard brush3-4 Hrspotable water/ RollerWater proofingUndiluted -4-6 Hrs 1.65-1.85 Sqm/ltr 1st coat (for 02 coats application) |
| 38 | M&L for rendering 20 mm thick plaster on concretesurfaces or on fair faces of brick work in cement mortar 1:3 finished even and smooth with out using extra cement complete all as specified and directed. |
| 39 | M&L in repair to RCC sunshades, Chajjas, Balconies, Columns, Bands, Beams and similar RCC work at any position/ height by sosmantling loose/disintigrated portion dubbing out with Cement concrete 1:1.5:3, 15 mm to 50mm thick using 6 to 12 mm graded stone aggregate to make up and finished to required shape including provision of necessarysupports if required and stiching of cracks with mild steel U clamps made out of 8mmdia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) andreinforced with PVC chicken mesh including form work where ever required and finished with 10 mm thick plastering in cement mortar 1:4 finished even and fair without using extra cement including preparationof surfaces to receive finishes complete all as specified and directed. |
| 40 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed. |
| 41 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) incuding pointing in white cement (1:2) using marble dust withadmixture of pigment to match with shade of granite including 15mm thk screed bedin cement mortar 1:4 complete all as specified and directed. |
| 42 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 43 | Taking down of cement plaster of any descriptionand in any postion including racking out joints for key scrubing with water etc complete all as specified and directed. |
| 44 | M&L for 15mm thick rendering in cement mortar 1:4 in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and directed. |
| 45 | M&L for rendering 10mm thick in cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 46 | M&L for 5 mm thick rendering incement mortar 1:3on fair faces ofconcrete surfaces such assoffits of slabs, ceiling etc, in patches n exc 1 Sqm each finishing the surfaces fair and even complete all as specified and directed. |
| 47 | S&F for powder coated aluminium sliding windows three track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directed. (A) FRAME:-(i) Top and side member fortwo track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS.(ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalentas specified in PS.(C) Sliding shutter to be provided with 5.5 mm thick sheet glass complete all as specified and directed.(D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium \"U\" channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii)Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm.(E)Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat, complete all as specified and as directed. |
| 48 | M&L for Washing rubbing down and stopping of distempered surfaces any type of wall incl preperation and then applying one coat of oil bound distemper on old plastered surface by Auto rollerof any tint complete all as specified and directed. |
| 49 | M&L for preparation of old decorated plastered surfaces of walls(internal) by washing,rubbing down and stopping of distempered surfaces,priming plastered and other surfaces with alkali resistant priming paintand applying two coats of distemper oil emulsion,over 1mm thick coat of wall care putty incl. complete removal of existing treatment complete all as specified and directed. |
| 50 | M&L for Preparation of old painted wooden surfaces over 10 cm width or girth of any description and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | M&L for preparation of old painted steel surfaces over 10 cm width or girth of any description and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 52 | Removing vegitation/ plants from wall,roof, over chajjas water tank etc, growing in any position complete, including removing roots, bldgs upto 2 stories height including necessary scafolding and necessary tools complete all as specified and directed. |
| 53 | M&L for preparation of new undecorated surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 54 | M&L for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing ; scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 55 | M&L for preparation of old plaster surfaces(external face) of walls by washing,rubbing down and stopping of distempered surfaces and applying one coat of all weathercement based paint complete all as specified and directed. |
| 56 | M&L for preparation of new plaster surfaces(external face) of wallss and applying two coast of all weather cement based paint over alkali resistant priming paint complete all as specified and directed. |
| 57 | S&F forVitreous china wash hand basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted /erecting stand including cutting and pinning in ends making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable wash hand basin and connected items of any description complete all as specified and directed. |
| 58 | S&F for 15mm bore dia pillar taps, fancy type chromium plated with capstan heads chromium plated screwed down high pressure, with or without lettered \"hot or cold\" with long screwed shank and fly nuts screw for iron pipe complete all as specified and directed. |
| 59 | Dismentling and breaking up drain pipes AC/ CI/ PVC Pipes set in cement mortar 100mm/75mmbore complete all as specified and directed. |
| 60 | M&L for 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement complete all as specified and directed. |
| 61 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 110mm bore complete all as specified and directed. |
| 62 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 75mm bore complete all as specified and directed. |
| 63 | S&F for PVC (SWR) bends any radius 110mm bore complete all as specified and directed. |
| 64 | S&F for PVC (SWR) bends any radius 75mm bore complete all as specified and directed. |
| 65 | S&F for PVC (SWR) single \"T\" equal or unequal with access door 110mm bore complete all as specified and directed. |
| 66 | S&F for PVC (SWR) single T equal or unequal with access door 75mm bore complete all as specified and directed. |
| 67 | S&F for PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 68 | S&F in repair 40mmdia waste pipe for sinks, basins, etc complete all as specified and directed. |
| 69 | S&F for grating doom 100/125 mm dia of PTMT (Minimum weight 5gms) complete all as specified and directed. |
| 70 | Taking up or down GI tubing 15mm bore including cleaning for refixing complete all as specified and directed. |
| 71 | Taking up or down GI tubing 20mm bore complete all as specified and directed. |
| 72 | S&F for 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 73 | S&F for 15 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 74 | S&F for 15 mm dia bore Stop valves/ angle valve, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as specified and directed. |
| 75 | S&F for 20 mm bore ballbrassvalve,high pressure with polythene float and fly nut complete,screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 76 | S&F for20 mm dia Gun-metal,globe or gate valves ,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 77 | S&F forrotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 ltr capacity hoisted and fixed in position with air pipe all as specified including dismantling old one complete all as specified and directed. |
| 78 | M&L for cutting chases for concealed water tubing and making good to facing in cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed. |
| 79 | S&F for solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 80 | S&F for factory made solid panel pvc doorshutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 81 | Taking down chowkats or frames n.exc 1.5 sqmeach with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 82 | Dismantling of water tanks of capacity exc 250 & n.exc 500 ltrs and removing to store complete all as specified and directed. |
| 83 | S&F for 75mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 84 | S&F for 100mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 85 | S&F for 100 mm aluminium handles, cast type, anodised complete all as specified and directed. |
| 86 | S&F for 100mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 87 | M&L for 32mm waste fittings, brass, chromium plated for wash hand basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and directed. |
| 88 | S&F in repairCP Grating doom 125 mm dia(minimum wt 40grms) complete all as specified and directed. |
| 89 | M&L for aluminium ventilator frames with frame of section 100mm x 44 mm of thickness1.6 mm shutters of section32 mm x 15mm (with and including half portion fixed glazed shutterand rest half portionlouvered with glazedshutter) including stainless steel wire mesh, rubbergasket for securingth glass, 5.5 mm thick figuredglass, aluminium grill and necessary aluminiummongaries and handles includingnecessary lockingarrangment complete all as specified and directed. |
| 90 | S&F in repair Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, flush pipe fixed as in repair complete jointing, connecting and making good the disturbed surfaces complete all as specified and directed. |
| 91 | S&F in repair PVC valveless, syphone action type flushing cistern, low level, white with inlet ball valve float and handle 10 ltrs capacity incl brackets complete all as specified and directed. |
| 92 | S&F in repairHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 93 | S&F for waste coupling of 40 mm dia of PTMT (Half or full threaded). (minimum weight32 mm-45 gms/40mm -60 gms) complete all as specified and directed. |
| 94 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 95 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15mm thkfor laying floor finishes of cement mortar 1:6 complete all as specified and directed. |
| 96 | M&L for Glazed ceramic tiles in vertical surfaces of size 300 x 200 x7 mm thick,set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surface including 15 mm thk backing coat in cement mortar 1:4 including taking down the existingcomplete all as specified and directed. |
| 97 | Demolition of cement concrete(un-reinforeced) of any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 98 | M&L for cement concrete Type C-1, 1:3:6 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering ,slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 99 | M&L for 25 mm thick cementt concrete type B-1,1:2:4 (20mm graded stone aggregate) as in sub -floors, sub -bases, floors and paving etc complete all as specified and directed. |
| 100 | Excavation in trenches, n.exc 1.5 M wide and exc1.5 M but n.exc 3.0 M depth for foundation etc and getting out in hard/ dense soil complete all as specified and directed. |
| 101 | Excavating in post holes (orsimilar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earthor broken rubble mixed withearth around, in layers not exceeding 25 cm soft / loose soil complete all as specified and directed. |
| 102 | M&L for PCC1:3:6 type C2 using 40mm graded stone aggregate) infoundation filling mass concrete complete all as specified and directed. |
| 103 | M&L for brick work built in cement mortar 1:4 straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 104 | S&F for Steel work in Roof trusses (framed) trussed purlins,crane gantries purlins, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces cleats etc complete all as specified and directed. |
| 105 | Removing excavated material exc 1.50 km but n.ex. 5 Km and depositing where directed complete all as specified and directed. |
| 106 | M&L for rendering 10mm thick on stone masonary or surface other than fair finishes of brickwork or other side of lathing in cement mortar (1:6) on concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 107 | M&L for preparation of new plastered surfaces of walls applying one coats exterior emulsion paint 100% acrylic, in camouflage pattern, any tinted, including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and directed. |
| 108 | M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer over one coat of wall care putty (2mm thick) complete all as specified and directed. |
| 109 | S&F for Pre-painted galvalume aluminum zinc coating steel trapizoidal/ corrugated 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 110 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc 0.11 sqm but n.exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 111 | S&F for glazed ceramic coloured /printed tiles 350x250x 7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match on verticle surface of wall complete all as specified and directed. |
| 112 | S&F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and directed. |
| 113 | S&F for factory made solid PVC moulded door shutter, with particle board core, 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm prelam PVC sheet on back face, fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 114 | S&F for extruded aluminium alloy handles, fabricated type, anodised, 150mm complete all as specified and directed. |
| 115 | S&F for 150 mm long aluminium anodised barrel tower bolt complete all as specified and directed. |
| 116 | S&F for Butt hinges 100mm long (type C 21) extruded aluminium alloy complete all as specified and directed. |
| 117 | S&F for Steel windows or ventilators, fixed type, with glazing bars etc complete all as specified and directed. |
| 118 | S&F for PVC pipe of dia 110 mm single socketed, in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed. |
| 119 | S&F for PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 120 | S&F for 15mm bore Bib taps long body with wall flange fancy type chromium plated cast copper alloy with capstan head screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 121 | S&F for Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device,complete jointing, connecting and making good the disturbed surfaces complete all as specified and directed. |
| 122 | S&F for 10 Ltr capacity PVC valveless, syphonic action type,low level flushing cistern white complete with in let, ball valve float and handle incl bracket complete all as specified and directed. |
| 123 | S&F for vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe complete all as specified and directed. |
| 124 | S&F for vitreous china wash basin, white, flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, flush pipe, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed. |
| 125 | S&F for 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 126 | S&Ffor PTMT waste coupling 32mm (half or full thread) complete all as specified and directed. |
| 127 | S&F for 75 mm PVC (SWR) floor trap, plain with stainless steel grating including jointing with solvent cement, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed. |
| 128 | S&F for 15 mm fancy type, chromium plated ,Stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 129 | S&F for CPVC pipes25 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 130 | S&F for Rotational moulded PVC water storage tanks 500 lts capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed including covers complete all as specified and directed. |
| 131 | S&F for float valve of PVC 20mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass and fixed complete all as specified and directed. |
| 132 | M&L for 75 mm thick PCC 1:3:6 type C2 (Using 40mm graded granite stone aggregate) as in plinth protection finishd even and smooth with out using extra cement complete all as specified and directed. |
| 133 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement type \"P\" complete all as specified and directed. |
| 134 | S&F for 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thck AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 135 | M&L for Reinforced cement concrete pipes 150mm bore, class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 136 | M&L for Cement concrete 1:3:6 type C2 for bed to drain pipes 150mm bore including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed. |
| 137 | M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in base complete all as specified and directed. |
| 138 | S&F for brass chromium platedtubular towel rail, 20mm dia,60cm long between flanges complete all as specified and directed. |
| 139 | M&L for concealed Point wiring with 1.5 Sqmm copper conductor single core, FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC rigid conduit and its accessories of suitable size, high grade ISI marked concealed in walls /roof and MS pressed steel terminal boxes of 1.22 mm thick of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement incl provision of 3 mm thick bakelite hylem sheet for mounting the switches/ sockets/ regulators etc including running up of 1.5 Sqmm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed. |
| 140 | One light point controlled by one way switch 5/6 amps. |
| 141 | One ceiling fan/Exhaut fan/Wall Fan point controlled by one way switch 5/6 amps. |
| 142 | S&F for switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 143 | S&F for ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 144 | S&F for IP 20, class I, LED light 1X18/20 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with complete all as specified and directed.Make : Havells Cat Part No LHEXAPP7PN1W020. |
| 145 | S&F for Bulk head luminaire suitable for 10 WattLED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting complete all as specified and directed.Make : Crompton Cat Part No LBHE-10-CDL. |
| 146 | S&F for Exhaust fan, 230 V, 300 mm sweep,metal body and heavy duty with all accessories internally prewired and connecting up with complete all as specified and directed. |
| 147 | S&F for MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 4 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and directed. |
| 148 | S&F for MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unsv one complete all as specified and directed. |
| 149 | S&F for MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unsv one complete all as specified and directed. |
| 150 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 6 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed. Note : Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\". |
| 151 | Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed. |
| 152 | M&L for 32 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. |
| 153 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6.3mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion complete all as specified and directed. |
| 154 | Supply and laying pipe galvanized, “Medium grade”, 25mm bore including fittings complete all as specified and directed. |
| 155 | Supply and laying pipe galvanized, “Medium grade”, 20mm including fittings complete all as specified and directed. |
| 156 | S&F for Gun metal ,globe Gate Valves with iron wheel head of 25 mm dia bore complete with all accessories complete all as specified and directed. |
| 157 | S&F for Gun metal ,globe Gate Valves with iron wheel head of 20 mm dia bore complete with all accessories complete all as specified and directed. |
| 158 | M&L for cutting of existing Cast iron/ GI pipe of 80mm size for insertion of new tee & Branch complete all as specified and directed. |
| 159 | S&F for Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA(12 Amp) complete all as specified and directed. Make-V-GUARD ,Model No- VEI 400 PLUS. |
| 160 | M&L for sub main wiring with two run of 4.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi strandedand one run of insulated copper earth wire 4.0 Sqmm drawn through PVC Casing capingcomplete all as specified and directed. Note :- Copper conductor 3 run of 4.0 sqmm and one run PVC Casing caping shall be measured as one length. |
| 161 | S&F for epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection complete all as specified and directed. |
| 162 | Supply and install hi wall split units indoor/outdoor 1.5 Ton AC complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity as shown complete all as specified and directed. |
| 163 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail