| 1 | Schedule \"A\" |
| 2 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 3 | M & L for brick work with sub class ‘B’ brick, old size (locally available best quality) straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 4 | M & L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundationbeams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed pilesand mass concrete vcomplete all as specified and directed. |
| 5 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed. |
| 6 | M & L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. |
| 7 | Ditto as per item no 5.00 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 8 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) complete all as specified and directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 10 | S&F Structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed. |
| 11 | M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed. |
| 12 | M&L for preparation of old painted surfaces of steel of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 13 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 14 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 15 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 16 | S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and directed. |
| 17 | M&L for 4mm thick plywood (no of ply 03), grade BWR,type BB fixed with nails or screws to timber frame work complete all as specified and directed. |
| 18 | M & L for rendering 10mm thick in CM 1:6 on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.(using Dimapur Sand) |
| 19 | M&L for rendering 15mm thick onfair faces of brick work or concrete surface in cement mortar (1:4)finishing the surface even and smooth without using extra cement complete all as specified and directed.(Using Dimapur Sand) |
| 20 | Supply only intergral water proofing compound complete all as specified and directed. |
| 21 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 22 | M&L for preparation of surfaces plastered or unplastered new surface and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed |
| 23 | Erection and Re-fixing only steel work in tubular trusses/post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1998 grade St-240 complete all as specified and as directed.Note:- serviceable material obtained from item no 8.00 |
| 24 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover filletscomplete all as specified and directed.Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items |
| 25 | S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Boardincluding fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. |
| 26 | S&F sheet glass 5.5 mm thick, ordinary quality and glazing with oil puttyin squarenot exc 0.5 sqm in each pane complete all as specified and as directed. |
| 27 | S&Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 28 | S&F in repairs fancy typedecorative Draparyrod of 20mm dia for window and doors withdecorative doom holders fixed to wall with screw complete all as specified and directed. |
| 29 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Source of Sand :- dimapur sand) |
| 30 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade \"A\" complete all as specified and directed. |
| 31 | Supply and fixing factory made UPVC white colour Sliding window Three track Area not exceeding 2.00 sqm eachmade of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each Shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) complete all as specified and directed. |
| 32 | Dismantling floor hearth or wall tiling including cement mortar bedding(but not backing) removing serviceable tiles to store & rubish of the permises complete all as specified and directed. |
| 33 | M&L for Non -skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 34 | M&L forNon - skid Ceramic coloured tiles in vertical surface 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade andincluding 10mm thick rendering in CM 1:4 as backing coat to receive tiles complete all as specified and directed. |
| 35 | S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 36 | Dismantling of unframed timber scantling40 sq .cm and over in section,in any position complete all as specified and directed. |
| 37 | M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed. |
| 38 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m eachcomplete all as specified and directed. |
| 39 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm eachcomplete all as specified and directed.. |
| 40 | S&F 35mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 41 | S&F 30mm thick 2nd class HW gazed skeleton shutters open rebated and preparedto receive glass gazed etc but divided into squares with plain chamfered or rounded mitred and rebated sash bar any numbers edges of framing plain chamfered or rounded fitted with cut and mittered beads for sceuring glass guage etc. size of members as specified in SSR pt-I section 8 clause 8.24(a) fitted to chowkhats completeall as specified and directed. |
| 42 | S&F 100 mm butt hinges medium weight cold rolled mild steel complete all as specified and directed. |
| 43 | S&F 150 mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. |
| 44 | S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 45 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and as directed. |
| 46 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 150mm overall length of cover plate complete all as specified and directed. |
| 47 | M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer fixed complete all as specified and directed. |
| 48 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc completeall as specified and directed. |
| 49 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 50 | Two light point controlled by one, one way switch |
| 51 | One ceiling/exhaust fan point controlled by one, one way switch |
| 52 | One socket outlet 5 Amps 5 pin on independent board |
| 53 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 54 | All as per item No. 48.00 here-in-above but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 55 | S&Fmodular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 56 | S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 57 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 58 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 59 | S&Fmodular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 60 | Taking downold unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. |
| 61 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. |
| 62 | S&F Sheet metal enclousre(for DB\"s when MCB to be used) single pole and neutral double door with rated bus bar 200 Amps, 4way, 240 Volts without MCB complete all as specified and directed. |
| 63 | S&F MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 64 | S&F MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 65 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 66 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 350mm x 300mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 67 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200mm x 150mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 68 | Taking down old unserviceable LED tube light fitting / building security light complete all as specified. |
| 69 | S&F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 70 | Supply and fixing round shape 15 to 22 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Note : Warm colour lights to be installed. |
| 71 | Taking down old unserviceable service cableincluding batten/suspending wires complete all as specified and directed. |
| 72 | S & F of 1100 volts grade heavy duty cabled PVC insulated aluminium conductor served with inner sheating of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than one meter apart including 4 mm suspensionwire one twin core cable 2 core flat of 10 sqmm size complete all as specified and directed. |
| 73 | Taking down ceiling/exhaust fan including dismantling all necessary electrical connections and kept in safe custody for refixing to its original position to facilitate repairs to ceiling/wall complete all as directed. |
| 74 | Refixing only ceiling fan removed under item Srl No 72.00 here-in-above and connecting upincluding provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 75 | S&F Modular step type regulator 120W, 1/2 module ,heavy duty, 240 volts complete all as specified and directed. |
| 76 | S&F building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP-66 high power LED light 25 watt including suitable size of wall bracket and connecting complete all as specified and directed. |
| 77 | M & L for submain wiring with single core 1.5 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 1.5 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length |
| 78 | M & L for submain wiring with single core 4.00 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length |
| 79 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately) |