Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-09-2025 |
| Sl. No. | Item Description |
| 1 | Taking down existing unserviceable point wiring of any type/ size of light/fan/socket/two way/bell etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and as directed. |
| 2 | Taking down existing unserviceable light fittings,security light fittings,bulk head fittings,fall ceiling light fittings etc. from any height of building complete all as specified and as directed. |
| 3 | Taking down existing unserviceable MCB\"s/MCCB\"s/Distribution boards any capacity complete all as specified and as directed. |
| 4 | Taking down earthing material complete plate and pipe etc from 2.25 mtrs depth complete all as specified and as directed. |
| 5 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one light point controlled by one switch complete all as specified and as directed Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 6 | All as per Sl item No 5 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator complete all as specified and as directed. |
| 7 | All as per Sl item No 5 above, but for One 5 Ampssocket outlet point on the independent board complete all as specified and as directed. |
| 8 | All as per Sl item No 5 above, but for One 5 Ampssocket outlet point on the same board complete all as specified and as directed. |
| 9 | All as per Sl item No. 5 here in before, but for OneBell point controlled by one, bell push complete all as specified and as directed. |
| 10 | All as per Sl item No 5 above but for One light point controlled by two way switchcomplete all as specified and as directed. |
| 11 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 15 Amps socket out let point complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 12 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiringmount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 13 | All as per Sl item No 12 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed. |
| 14 | All as per Sl item No. 12 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular boardcomplete all as specified and as directed. |
| 15 | All as per Sl item No. 12 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed. |
| 16 | All as per Sl item No. 12 here in before, but for OneBell point controlled by one, one way modular switch 5 amps, SP complete all as specified and as directed. |
| 17 | All as per Sl item No. 12 here in before,but for One light point controlled by two 2 - w a ymodular s w i t c h 5 amps, SP complete all as specified and as directed. |
| 18 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiringmount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 15 Amps socket outpoint independent board complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 19 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiringmount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 15 Amps socket outpoint same board complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 20 | M & L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiringmount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc.for one 15 Amps socket outpoint independent board complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 21 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards/sockets/regulators of any size modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one light point controlled by one switch complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 22 | All as per Sl item No 21 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed. |
| 23 | All as per Sl item No. 21 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular boardcomplete all as specified and as directed. |
| 24 | All as per Sl item No. 21 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed. |
| 25 | All as per Sl item No. 21 here in before, but for OneBell point controlled by one, one way modular switch 5 amps, SP complete all as specified and as directed. |
| 26 | All as per Sl item No. 21 here in before,but for One light point controlled by two 2 - w a ymodular s w i t c h 5 amps, SP complete all as specified and as directed. |
| 27 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. for one 15 Amps socket outpoint independent board complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 28 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC concealed conduit medium grade , ISI marked , 20 mm bore with conduit accessories forwiringconcealed in wall, including provision of fabricated branded pressed steel terminalboxconcealedof suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards of any size modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc.for one 15 Amps socket outpoint same board complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(2) The cost ofcutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 29 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through existing rigid PVC concealed conduit including provision of fabricated branded modular pressed steel terminalboxconcealedof suitable sizes with 1.6 mm thickness including modular cover frame of suitable size for modular switch boards/sockets/regulators of any size of modules configuration for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. for one light point/fan point/bell point/3 pin socket out let 6 Amps point on same, independent board controlled by one switch/2 way switch point controlled by two switch complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(ii)The cost ofcutting of chases of required width and depth for concealled modular sunken box incl plastering, making good to disturbed surface, painting two coats of distemper to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 30 | M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through existing rigid PVC concealed conduit including provision of fabricated branded modular pressed steel terminalboxconcealedof suitable sizes with 1.6 mm thickness including modular cover frame of suitable size for modular switch boards/sockets/regulators of any size of modules configuration for housing modular switches, sockets and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 3/5 pin 16 Amps socket out let point on same, independent board controlled by one switch complete all as specified and as directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.(ii)The cost ofcutting of chases of required width and depth for concealled modular sunken box incl plastering, making good to disturbed surface, painting two coats of distemper to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
| 31 | S & F in repair switch piano single pole flush type 6 amps, 230 volts. complete all as specified and as directed |
| 32 | S & F in repair switch piano single pole flush type 16 amps, 230 volts.complete all as specified and as directed |
| 33 | S & F in repair single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directed.Note:(i)All light/fan switches shall besymbol embossed (light/fan) type (ii) All switches for sockets shall beLED indicator type. |
| 34 | S & F in repair single pole Modular switch 1 way 16 Amps, 1 Module with red LED indicator complete all as specified and as directed. |
| 35 | S & F in repairSwitch piano two way flush type 6 Amps capacity 230 volts complete all as specified and as directed |
| 36 | S & F in repair Modular switch 2 way 6 Amps, 1 Module complete all as specified and as directed |
| 37 | S & F in repair bell push 5 A flush type complete all as specified and as directed |
| 38 | S & F in repair Modular Bell Push 6A, 1 Module with bell symbol complete all as specified and as directed |
| 39 | S & F in repair Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and as directed. |
| 40 | S & F in repair Socket modular type multipurpose 3/6 Pin, 16 amps, 230 volts 2 Module complete all as specified and as directed. |
| 41 | S & F in repair Socket flush type multipurpose 2 in 1, 3 Pin, 6 amps, 230 volts complete all as specified and as directed. |
| 42 | S & F in repair Socketflush type multipurpose 2 in 1, 3/6 Pin, 16 amps, 230 volts complete all as specified and as directed. |
| 43 | S & F in repair Switch socket combination flush type multipurpose 2/3 pin 6 amps 2 in 1230 Volts without point wiring complete all as specified and as directed. |
| 44 | S & F in repair Switch socket combination 5 in 1 multipurpose 3/5 pin 16 amps flush typewith without point wiring complete all as specified and as directed. |
| 45 | S & F in repairModular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified, complete all as specified and as directed |
| 46 | S&F in repair Modular frames of any size, capacity of moldule configuration suitable existing switch boards up to 24 modules white colour 6/16Amps complete all as specified and as directed. |
| 47 | S & F in repairhot and cold PVC connection pipe 60CM length 120 degrees centigrade temperature suitable forgeysers 15/25/50 ltrs complete all as specified, complete all as specified and as directed |
| 48 | S & F in repair Electronic type fan regulatorsocket type single module, suitable to work on 230 volts complete all as specified and as directed. |
| 49 | S&F in repair calling bell ding dong working on 230 volts AC with different ring tones optionalcomplete all as specified and as directed. |
| 50 | S & F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed. |
| 51 | S & F in repair lamp holder any angle suitable for LED Bulbs of capacity 7/15 watts insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and as directed |
| 52 | M&L for replacement of old unserviceacble light fitting withLED batten light fitting 20 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPRO LL31-251-XXX-65AL5/Havells ENDURALINEARPROBS20WLED865PCSSIND/Bajaj-BCLAB20WCWLEDXT |
| 53 | M&L for replacement of old unserviceacble light fitting with LED batten light fitting10 Watts 2 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make:Crompton CCS-103-10-65-SL-DP-NWH/ Havells LHEXAZP7PN1W010 / PHILIPS BN021LED12S 6500K PSU GR / WIPROLL20-111-XXX-65NE3 /Bajaj-BCLAB10WLEDCWLED |
| 54 | M&L for replacement of old unserviceacble light fitting withLED light fitting 10Watts bulkhead luminaires, efficacy not less than 100 lm/w, rated life 25000 burning hours including LED light driver holder connecting up with three core flexible copper conductor cable IP 65 out door type metal bodyof suitable size complete all as specified and as directed.Make: Crompton CIS-306-10-57-SL-DP-NBK/ PHILIPS WT202W LED10S CW PSU S3 PC/ HAVELLS HEXAFT10WLED857SSYMBOPC /WIPRO LW07-141-XXX-57-G1/Bajaj-BIBWP10W LED |
| 55 | M&L for replacement of old unserviceacble light fitting with LED security light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect as specified and directed complete in all respect as specified and directed Make:Crompton CRP-409-70-57-SL-GL-NSG/ PHILIPS-URBAN EDGE-BRP501LED078CWR5CPSUS1V1/ HAVELLS-ENDURA SUNDOWN SL70WLED765PASYBOTG/WIPRO-LR09-781-XXX-57-XX/Bajaj-ZELAP86LWHPOTGSDJ72W |
| 56 | M&L for replacement of old unserviceacble light fitting withLED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in complete as specified and as directed Make:Crompton TRP-409-45-57-SL-GL-NSG / PHILIPS BRP030LED35CWSLRGRPSUV1 / HAVELLS ENDURASUNDOWNSL45WLED765PASYBOPC/WIPRO LR22-501-XXX-57-XX/Bajaj-VISTAP45LWHPOPCSD |
| 57 | S & F 15 Watt LED Bulb 5 star rated efficacy not less than 100 Lumen/watts,rated life 25000 burning hourswith lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings including taking down the old unserviceable complete as specified and as directed |
| 58 | S & FLED Bulb 7 watts 5 star rated efficacy not less than 100 Lumen/watts,rated life 25000 burning hourswith lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings including taking down the old unserviceable complete as specified and as directed |
| 59 | S & F recess mounting LED light fitting 2\" x 2\" of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting ccomplete as specified and as directed .Make:Crompton: LCTLRP-36-FO-CDL / PHILIPS RC308LED36S6500 / HAVELLS VENUSEXL2X2PLR36WLED865SWH/WIPRO-CRCO10R036HE57G4/Bajaj-BZRSQL43LXEWHODSD |
| 60 | S & F surface mounting LED light fitting 2\" x 2\" of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete as specified and as directed Make: HAVELLS PLANOSUR2X2PLS36WLED857G2S/ PHILIPS SM367 LED36S-6500 G6 L54W54 PSU OD/ WIPRO CRCO10R036HE57G4+Frame/Bajaj-BZSSQL43LXEWHODSD |
| 61 | S & F recess mounting LED round light fitting of capacity 15 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete all as specified and as directed .Make:Crompton:LSCRM-15-CDL/Havells VIBEFLRDDLR15WLED857S/Philips DN296B LED 20S-6500 PSU WH S2/Bajaj-BGSLO15LLEDWHVC/Gold Medal-GL91327CD/Wipro-LD13R-171-XXX-57-XX |
| 62 | S & F recess mounting LED round light fitting of capacity 12 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete all as specified and as directed .Make:Crompton:LSCRM-12-CDL/Havells VIBEFLRDDLR12WLED857S/Philips DN296B LED 12S-6500 PSU WH /WiproLD13R-151-XXX-57-XX/Bajaj-BGSLO12LLEDWHVC |
| 63 | S & F recess mounting LED round light fitting of capacity 6 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceilingincluding making electrical connection from ceiling rose to light fitting complete all as specified and as directed .Make:Crompton:LSCRM-6W-CDL/Havells VIBEFLRDDLR6WLED857S/Philips DN295B LED 8S-6500 PSU WH/Wipro-LD13R-670-XX-57-XX /Bajaj-BGSLO6LLEDWHVC |
| 64 | S & Fdecorative wall light fixture of capacity not less than 10 wattsincluding LED bulb 10Watts B22 making electrical connection from ceiling rose to light fitting complete as specified and as directed Make:WIPRO-WL-WALLY-B22/Havells-FlorentineWL1LSB22SS-LHFOAJE1TZ1I060/Bajaj-BJLF4 7W TO 15 W |
| 65 | S&F in replacement of LED Bulb not less than 0.5Watts Red and Green Colour complete as specified and as directed |
| 66 | S & Fin repair MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA complete as specified and as directed |
| 67 | S & F in repair MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KAcomplete as specified and as directed |
| 68 | S & F in repair MCB TPN,63 Amps, rupturing capacity 10 KA 415 volts suitable for fixing in existing DB of any capacitycomplete as specified and as directed . |
| 69 | S & F in repair in replacementsheet metal enclosure MCB DBSPN 4 way double door with 100 ampsrated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 70 | S & Fin replacementsheet metal enclosure MCB DBSPN 8 way double doorwith 100 ampsrated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 71 | S & F in replacementsheet metal enclosure MCB DBSPN 12 way double doorwith 100 ampsrated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 72 | S & F in replacement of TPN DB 4 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. |
| 73 | S & F in replacement of TPN DB 4 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed . |
| 74 | S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) all as specified and as directed. |
| 75 | S&F MCCB 415V, 16KA, 100 amps 4 Pole, thermal magnetic release fixedtype,short circuit and over load protection suitable for DB including removing the existing unserviceable one complete all as specified and as directed. |
| 76 | S&F MCCB 415V, 16KA, 63 amps 4 Pole thermal magnetic release fixedtype,short circuit and over load protection suitable for DB including removing the existing unserviceable one complete all as specified and as directed. |
| 77 | M & L Submain concealed wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVCconcealed conduitand conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth(2)The cost ofcutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The three runs of copper wireone run of PVC coduit is shall be measured as one running meter. |
| 78 | M & L Submain concealed wiring with 2 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVCconcealed conduitand conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth(2)The cost ofcutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The three runs of copper wireone run of PVC coduit is shall be measured as one running meter. |
| 79 | M & L Submain concealed wiring with 4 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVCconcealed conduitand conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth(2)The cost ofcutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The FIVE runs of copper wireone run of PVC coduit is shall be measured as one running meter. |
| 80 | M & L Submain concealed wiring with 4 runs of single core 10 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVCconcealed conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 10 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.Note:-(1) The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth(2)The cost ofcutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted rate.(3) The FIVE runs of copper wireone run of PVC coduit is shall be measured as one running meter. |
| 81 | Taking down carefully geysers from site of any make and capacity, transporting to MES complaint cell for dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of tank thoroughly with washing compound or liquid solution, applying one coat of milky white synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint complete servicing and re-fixing of geysers at its original position complete all as specified and directed.Note :(a)Spare part shall be measured and paid separately under respective item of this schedule, however minor items which are not catered in this schedule, the cost of the same shall be deemed to be included in the unit rate of these items.(b) Repair works will be carried out at workshop E&M complaint cell.(c) Repair of geyser shall be completed and re-fixed the same with in 72 Hrs after receipt of complaint slip.(d)The cost of transportation to workshop and back is deemed to be included in the quoted rate of this item. |
| 82 | M & L for repairs to copper inner tank, like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified and as directed |
| 83 | Supply and replace Geyser element2000 watts /1500watts of any type (Circular OR tringular) or as per site requirement complete as specified and as directed |
| 84 | Supply and replace Thermostat suitable for existing geyserof 15/25/50 litres of any make complete all as specified and as directed. |
| 85 | Supply and replace Indicator bulb 230 V suitable for any make and colour complete all as specified and as directed. |
| 86 | S &F Bib taps chromium plated with crutch or butter fly handle 15 mm dia screwed for iron pipe or for brass ferrule and fixed including cutting of GI pipe completeall as specified and as directed. |
| 87 | S & F GI pipe 15 mm dia medium grade for geysers raising main & down comer connections includning complete fittings and accessoriesand earthings complete all as specified and as directed. |
| 88 | Supply & fix gate valve 15 mm dia COPPER ALLOYED CHROMIUM PLATED |
| 89 | Supply and fixing in replacement inner tank, ISI marked made of stainless steel suitable for 25 Litters capacity geyser complete all as specified and directed. |
| 90 | Supply and fixing PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire complete all as specified and directed. |
| 91 | Supply and replace Plug top 5 Amps 3 pin 250 Volts complete all as specified and as directed |
| 92 | Supply and fix Plug Top 3 pin 15 Amps for storage geyser including removal of existing plug top complete all as specified and directed. . |
| 93 | Supply and replace Industrial type Plug top 3 pin, 20 Amps suitable for industrial socket for storage geyser including taking down old UNSV / rusted complete all as specified and as directed |
| 94 | Taking down ceiling/exhaust fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and transportation to MES Complaint Cell, cleaning externally, dismantling and examining the rotor, startor, bearings, bushes, etc; for serviceability and repairing/replacing the defective parts subsequently oiling, greasing, assembling, testing for proper functioning, checking for safety securityand proper locking, transporting back to building/site from work shop, hanging at its original position and connecting electrical connections,complete servicing, testing for noise free smooth running etc complete all as specified and as directed |
| 95 | Taking down old unserviceable rusted ceiling/exhaust fan blades andproviding new ceiling fan blades & screws as appropriate shape and size suitable for ceiling fans any make and size 1200mm/1400mm sweep complete all as specified and directed. |
| 96 | supply and fix in replacement new metallic clamps (minium 03 mm thick), rubber bush, nut bolt, washer and cotter pin and for various types of ceiling fans to complete the repair work complete all as specified and as directed |
| 97 | M & L for paintingof ceiling fans/exhuast fans along with blades of any make/model of size upto 1400mm sweep , cleaning thoroughly with sand paper,remove residue, three coats of supper enameled white colour paintover a coat of primer,dried in woven, printing MES No in 20mm letter size stamping template with black paint etc complete all as specified and as directed.Note :-The rate quoted deemed to be inclusive of hiring ofpainting equipment, taking down and shiftingof celing fans at users site. |
| 98 | Taking out defective/worn out Ball Bearing of any make and supply and fix new bearing suitable for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed. |
| 99 | Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed. |
| 100 | Taking out defective capacitor and supply and fix new capacitor of 3.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed. |
| 101 | Taking out defective capacitor and supply and fix new capacitor of 4.0 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed |
| 102 | Taking out worn out Gun metal bush and supply and fix new Gun metal bush for various makes of ceiling fans of size 1200mm/1400mm sweep. (as per sample) complete all as specified and as directed. |
| 103 | Taking down Canopy supply and fix new canopy as approved suitable for Ceiling Fans of 1200/1400 mm sweep ofany make/colour complete all as specified and as directed. |
| 104 | S&F in replacement of ceiling fan downrod of required heightincluding drilling of holes and threads of dia 15 mmas per the site requirement complete all as specified and as directed |
| 105 | Supply and fix inreplacement of unserviceable gang box wtih modular Gang box5 Amps modular switch socket complete all as specified and as directed |
| 106 | Supply and fix inreplacement of unserviceable gang box wtih modular Gang box15 Amps modular switch socket complete all as specified and as directed |
| 107 | Supply and replace PVC Dummy sheets circular type of 4\" complete all as specified and as directed |
| 108 | Supply and replace PVC Dummy sheets circular type of 6\" complete all as specified and as directed |
| 109 | M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on complete all as specified and as directed (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate). |
| 110 | M & L for replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to polesany other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. |
| 111 | S & Ftwin core flexible twisted copper conductor wire1.1 KV for Phase (Red) and neutral (Black) of size 0.5 Sqmmfor connecting light/switch /socket etc. as per site requirement including taking down old unserviceable one complete all as specified and as directed. |
| 112 | S&F LED Driverssuitable for any type/size of LED lights up to 40 watts complete all as specified and as directed |
| 113 | S&F in replacement of louvers duly fabrcated with GI sheet metal frame suitable for 200 to 450 mm sweep Exhaust fans complete all as specified and as directed Note: The rated quoted deemed to be inclusive of required T&P for any height. |
| 114 | S&F in replacement of modular sunken boxes MS factory brandedof up to four module complete all as specified and as directed Note:(i) The rated quoted deemed to be inclusive of taking down of existing old unserviceable sunken boxes.(ii)The cost ofcutting of chases of required width and depth for concealled modular sunken box incl plastering, making good to disturbed surface, painting two coats of distemper to match the existing wall colour is deemed to be included in the quoted rate by the contractor. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy