| 1 | Taking downcement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 2 | M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces inCM in 1:6 finished even and fair without using etra cement complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. |
| 4 | M&L for cement concrete 25mm thick PCC type B0, 1:2:4 (12.5mm graded aggregate for sub base complete all as specified and directed.. |
| 5 | S&F for vitrified tiles 10mm thick dark shade (squares/rectangular) area of each tileexc 0.18 but not exceeding 0.38 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed in CM(1:6) complete all as specified and directed. |
| 6 | S&F Coloured Glazed ceramic tiles in vertical surfaces350x250mmx7mm/450x350x7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick backing coat in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed. |
| 7 | M&L Water proofing treatment on roofsurface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer properly cleaning & drying the concrete surfaces complete all as specified and directed. |
| 8 | M&L 10 mm thick rendering on roof surfaces/concrete surface in CM 1:3 complete all as specified and directed. |
| 9 | M&L forLaying 3 mm thick unrolled polymeric water proofing APP based polymeric membrane Reinforced with plolyster non move febric wt not less than 3kg /Sqm with 150gms/sqm over primed surface of forced application complete all as specified and directed. |
| 10 | Applying two coats of bituminous base aluminium paint on new surfaces of APP Surfacesincluding preparation complete all as specified and directed. |
| 11 | M&L PCC 1:2:4 type B1 using 40 mm graded stone aggregate as in concrete padding laid to required slope incl finishing the concrete surface fair and even without using extra cement complete all as specified and as directed. |
| 12 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 13 | Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 14 | S & F Bullet proof glass 40mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required including test certificate also requried complete all as specification and directed. |
| 15 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® complete all as spccified and directed |
| 16 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of E complete all as specified and directed. |
| 17 | S&F for Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (Onevertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.)(A) Area not exceeding 2.00 sqm each complete all as specified and directed. |
| 18 | S&F for acrylic sheet tranparant 5 mm thick ordinary quality and glazing with oil putty in square each pane complete all as specified and directed. |
| 19 | S&F Butt hinges medium weight cold rolled mild steel 100mm long complete all as specified and directed. |
| 20 | S&F Aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and directed. |
| 21 | S&F Aluminium handles cast type anodised of 200mm complete all as specified and directed.. |
| 22 | S&F in repair aluminium alloy anodized sliding door bolt with hasp,staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 300mm complete all as specified and directed. |
| 23 | Complete removal to existing treatment of oldsurfaces of wall and applying two coat of distemper oil emulsion over acoat wall care putty over a coat of alkali resistant cement based primer on wall surfaces & smoothening the surfaces with sand papers etc., complete all as specified and directed. |
| 24 | M&L for newsurfaces of wall and applying two coat of distemper oil emulsion over acoat wall care putty over a coat of alkali resistant cement based primer on wall surfaces & smoothening the surfaces with sand papers etc., complete all as specified and directed. |
| 25 | Material & Labour for complete removal to existing treatment applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 26 | Demolition of brick work or stone builder masonry any description complete all as specified and directed. |
| 27 | M&L for Brick work with sub class \"B\" bircks straight or curved on plan exc 6mtr mean radius in CM 1:6 complete all as specified and directed. |
| 28 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 29 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeFe-290 (Gde E 165) complete all as specified and directed. |
| 30 | S&F for Mild steel, 3mm Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk) forming holes, without any attachmentas required Fe 410-W(GdeE- 250) quality A complete all as specified and directed. |
| 31 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc.or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 32 | M&L for PCC in foundationfilling and mass concrete type D2(1:4:8) using 40 mm graded stone aggregate as complete all as specified and directed. |
| 33 | M&L for RCC drain M-25 using 20 mm graded stone aggregate as in RCC drain, walls, retaining wall, ballast walls, and the like complete all as specified and directed. |
| 34 | M & L for pre-cast cement concrete Type B-1 1:2:4 using 20 mm graded stone aggregate in landing, cover slabs (for manholes etc), shelves and similar articles, with plain faces and set in cement mortar 1:6 complete all as specified and directed. |
| 35 | Mild SteelTMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 36 | M & L for formwork to faces of walls, retaining wall, parapets, staircase railing and similar works including attached pillasters, buttressess etcin rough finished flat surface of concrete complete all as specified and directed. |
| 37 | Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25cm etc complete all as specified and directed |
| 38 | S&F for 110 mm dia PVC SWR rain water pipe single socketed in any length with rubber ring joint laid in trenches or in floor etc complete all as specified and directed. |
| 39 | S&F for 110 mm dia PVC SWR bends any radius complete all as specified and directed. |
| 40 | S&F for 110 mm dia branch pieces single (single Y) equal or un equal complete all as specified and directed. |
| 41 | Removingexcavated Soil exc. 50 m but not exc.250 mand depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 42 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 43 | Excavation in trenches not exc. 1.50 m wide andexc. 1.50 m but not exc 3 min depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 44 | Excavation in trenches not exc. 1.50 m wide andexc. 3 m but not exc 4.5 min depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 45 | Excavation in trenches not exc. 1.50 m wide andexc.4.5 m but not exc 6 min depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 46 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 47 | M&L Brick work using old size bricks with sub class \"B\" bricks in one brick thick honey comb walling built in cement mortar 1:6 complete all as specified and directed. |
| 48 | M&L Brick work using old size bricks with sub class \"B\" bricks in one and half brick thick honey comb walling built in cement mortar 1:6 complete all as specified and directed. |
| 49 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed. |
| 50 | M&L Broken bricks of gauge not exceeding 63 mm for loose filling in sokage pit, sokage wells complete all as specified and directed. |
| 51 | Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed |
| 52 | M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves etc.complete all as specified and directed |
| 53 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed |
| 54 | S&F, PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 55 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etcwith or without conduit , casing caping complete all as specified and directed. |
| 56 | M&L for Point wiring(concealed) for light point in and including rigid non metalic PVC heavey duty conduit , 19/20mm dia suitable size including cutting chesses for conduits sinking for boxes for concealed conduit wiringwith 1.5 sqmm FRLS PVC insulated , unsheathed multi stranded copper copper conductor cable single core 1100 volt grade including metal sheet enclosurerectangular boxes of suitable size and and white cover plate suitable for fixing modular switches ,sockets, and fan regulator etc including PVC insulated unsheathed multi stranded copper conductor of 1.5 sqmm as earth wire connected to common earth dolly as per IS specification and as specified in SSR part- 1 complete for one light point/fan point/bell point controlled by one modular switch 1 way 6 Amp,one module complete all as specified and directed. |
| 57 | ~Ditto~ all as per item No 53 here in before but with one 3 pin 5 Amp socket outlet on the same board complete all as specified and directed. |
| 58 | ~Ditto~ all as per item No 53 here in before but with one 3 pin 5 Amp socket outlet on independentboard complete all as specified and directed. |
| 59 | ~Ditto~ all as per item No 53here-in-before but with 2.5 Sqmm copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board complete all as specified and directed. |
| 60 | ~Ditto~ all as per item No 53here-in-before but with 4 Sqmmand 4 Sqmm as earth continuity complete all as specified and directed. |
| 61 | M&L for sub main wiring with 4 single core, multi stranded,PVC insulated, 1100 Volt grade, FRLS,cable with copper conductor of size 10 Sq mm in and including/drawing throughthrough rigid non metalic PVC conduit medium grade, ISI marked, 25 mm dia for sub main wiring including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected common earth. (Note :-4x 6 Sq mm conductor cable, 1 x 6Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length) complete all as specified and directed. |
| 62 | Supply & Fixing Switch Modular 6Aone way, 1 module complete all as specified and directed. |
| 63 | Supply & Fixing Switch Modular 16Aone way, 1 module complete all as specified and directed. |
| 64 | Supply & Fixing Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 65 | Supply & Fixing Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 66 | Supply & Fixing Modular Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 67 | S&F in replacement of frame plate for modular switch 3 module includingscrews and washers etc model/make as per existingin site complete all as specified and directed. |
| 68 | S&F in replacement of frame plate for modular switch 4 module includingscrews and washers etc model/make as per existingin site complete all as specified and directed. |
| 69 | S&F in replacement of frame plate for modular switch 6module includingscrews and washers etc model/make as per existingin site complete all as specified and directed. |
| 70 | S&F in replacement of frame plate for modular switch 8 module with indicating lamp includingscrews and washers etc model/make as per existingin site complete all specified and directed. |
| 71 | S&F in replacement of frame plate for modular switch 12 module with indicating lamp includingscrews and washers etc model/make as per existingin site complete all specified and directed. |
| 72 | S&F in replacementMS Housing box 3 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and directed. |
| 73 | S&F in replacementMS Housing box 4/5 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified anddirected. |
| 74 | S&F in replacementMS Housing box 6 module suitable formodular switch as per existingswitch boxand making good to the disturb surface complete all as specified and directed. |
| 75 | S&F in replacementMS Housing box 8 module suitable formodular switch as per existingswitch boxand making good to the disturb surface complete all as specified and directed. |
| 76 | S&F in replacementMS Housing box 12module suitable formodular switch as per existingswitch boxand making good to the disturb surface complete all as specified anddirected. |
| 77 | M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed. |
| 78 | Supply and fixing sheet metal enclosure SPN with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and directed. |
| 79 | S & F LED lights fitting 20 watt, 220V, AC decorative box type Tube light with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 80 | S & F in repair LED Bldg Security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant with IP 65/66 protection complete including GI bracket of suitable size bent to shape and fixed on wall with metal fastners 2 Nos incl drilling of holes as reqd and connecting up with flexible copper cable from ceiling rose to the light fitting and complete all as specified and directed. |
| 81 | Taking down ceiling fan/ exahaust fan/ wall mounted fan,by dismantling all electric connection which becomes unserviceable andrequiredrewinding and paintingand deposit to MES store yard for further disposal complete all as specified and directed |
| 82 | S&F ceiling fan complete with blades, down rod, electronic regulater and accessories 230V,1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including writing MES Number complete all as specified and directed. |
| 83 | S&F exahaust fan steel body AC single phase 230V of size 300mm sweep with blades, frame and louvers including writing MES Number complete all as specified and directed. |
| 84 | S&F wall mounted fan 300mm sweep ,2150RPMair delivery 90 CMM,Power 115W including writing of MES No complete all as specified and directed. |
| 85 | M&L for MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with 200 Amps rated bus bar and neutral etc. and fixing MCBs of various rating capacityincluding taking down old unsv MCB DBs complete all as specified and as directed. |
| 86 | M&L for MCB Distribution board single door type SPN 8 way, sheet steel, powder painted for fixing MCBs of various rating capacityincluding taking down old unsv MCB DBs complete all as specified and as directed. |
| 87 | M&L for MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" series incl taking down old unsv MCB complete all as specified anddirected. |
| 88 | M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriesincl taking down old unsv MCB complete all as specified and directed. |
| 89 | Supply and fixing 415 Volt,10KA B curve MCB TPN/FP 40 to 100 Amp complete with connection, testing and commissioning complete all as specified and directed. |
| 90 | S&F RCBs for earth leakage, overload & shortcircuite protection of capacity 30mA four pole 40Amp complete all as specified and directed. |
| 91 | Earthing complete with galvanised steel earth plate electrode 60cmX60cmX 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised ironor steel all as shown in electricalplate No. 3 connected to earthing test point or indicated including testing on completion complete all as specified and directed. |
| 92 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 93 | Supply laying and fixing of GI tubing ofsize 25mm dia medium grade ISI Marked with all necesary fittings laid in trenches complete all as spccified and directed. |
| 94 | Supply and and fixingGun metal/brass, globe or gate valveswith iron wheel head, screwed both ends for iron pipe of size 25mm dia complete all as spccified and directed |
| 95 | Supply , testing, commissioningand installation of Monoblock pump set of capacity 2 HP Electric driven 230V, 50HZ including all necessary electric connection and foundation & protective covering made of Galvanium sheet , angle iron, reqd welding wk & PCC wk complete all as specified and directed. |
| 96 | Supply and fix DOL starter suitable for 2HP Motor complete all as spccified and directed. |
| 97 | Supply, lay, testing XLPE insulated armored heavy duty electric cable with aluminium conductor , 1100 volts grade with stranded aluminium conductor cross sectional area 6Sqmm 2 core in trenches complete all as specified anddirected. |
| 98 | M & L for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and directed. |
| 99 | Supplying and layingreenforced precast concrete cable cover class EHV, type 1 with peak , size 450mm X 230mm X 50mm for cable protection complete all as specified and directed. |
| 100 | Schedule of credit of amount Rs. 8,100.00 to be deducted during AOC. |