Tender For Provision Of Mes Office Building At Af Stn Bhowali; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 SCHEDULE A PART II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ PartII. 5 SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) 6 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ PartIII. 7 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ PartIV . 9 SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ PartV 11 SCHEDULE A PART VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ PartVI 13 SCHEDULE A PART VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ PartVII 15 SCHEDULE A PART- VIII (PATH WITH INTER LOCKING TILES) 16 Lump sum price worked out by the contractor for PATH WITH INTER LOCKING TILES as listed in Sch ‘A’ PartVIII 17 SCHEDULE A PART- IX (FENCING AND GATE) 18 Lump sum price worked out by the contractor for COMPOUND WALL, FENCING AND GATEas listed in Sch ‘A’ Part IX 19 SCHEDULE A PART- X (EARTHWORK AND SITE CLEARANCE) 20 Lump sum price worked out by the contractor for EARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part X 21 SCHEDULE A PART- XI (INTERNAL E/M SERVICES (AIR CONDITION WORK)) 22 Lump sum price worked out by the contractor for Internal E/M Servicews (INTERNAL E/M SERVICES (AIR CONDITION WORK) as listed in Sch ‘A’ Part XI 23 Supply and fixing stablizer 4 KVA capacity installed for split AC single phase 230 volts 50 Hz with copper wound bulk and boost type with high and low voltage cut off 2-3minute time delay relay with input voltage range 140-280 volts and out put voltage of 200-240 volts with 95 % efficiency, complete all as specified and directed. 24 M & L for construction of septic tank 50 users with brick masonry wall, PCC in foundation, floor, cover slab including sludge chamber, CI vent cowl, inlet and outlet pipe, RCC baffle wall and all necessary earth work, complete all as specifed and directed in Drg No TD 217 sheet 1/2 and 2/2. 25 M & L for soakage well 3.60 mtr Internal dia and 3.00 mtr effetive depth including excavation in any type of soil, foundation in PCC 1:3:6, wall of honey combing and solid masonry wall, RCC M 25 cover slab, SRFC cover, brick bats filling, Dwarf wall etc complete all as specifed and directed in Drg No Td / 576 1/2 and 2/2, complete all as specifed and directed. 26 Supply and fixing LED security light fitting 40 watt IP - 65 having pressure die cast aluminium housing with heat resistant toughened glass , individual LED lenses, 4 KV internal and 10 KV external surge protection, min 100 lm / watt, colour temperature 6000 to 6500 K, PF > 0.95, CRI > 75 and THD < 10, 230 volts completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable, complete all as specified and directed. 27 S & F flush mounted factory made epoxy powder coated distribution board VTPN 4 ways conforming to IS 8623-1, IEC-61439-1&3, double door with metallictop cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, 02 neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. 28 S & F RJ 11 tele jack single shutter 1 module complete with GI box and front cove, all as speciefeied and directed. 29 S & F TV socket jack single with shutter 1 module omplete with GI box and front cove, all as speciefeied and directed. 30 M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate No 5of SSR Part I completeall as specified and directed and testing on completion. Note :- (i) Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) The rate quoted by the contractor are deemed to be inclusive for MS sheet of size 300x300x3 mm thick as in pit cover, fixed with necessary nuts and bolts on angle iron of size 40x40x5 mm, 60 cm long and grounted in PCC 1:2:4 type B 1 block of size 200x200x250 mm including necessary earth work and marking of result.(iii) Excavation and earth work in any type of soil is demed to be inclusive in the rate qupted. 31 S & F MCCB 125 Amps 4 pole 415 volts thermal magnetic release, adjustable type range 20 Amp to 125 Amps in and including sheet metal enclosure, fixed on wall, complete all as specified and directed. 32 M & L for horizontal boring / drilling by machines / manual under the road in any type of soilwith out cutting / disturbing the existing road and inserting HDPE pipe of 150 mm bore of suitable for 4 Mpa working pressure, for drawing cable complete all as specified and directed.