Tender For Maintenance Work Of Firefighting System Of 3X210 Mw, Atps 2X500 Mw, Btps And 2X500 Mw, Dtps, Anpara
Tender Value
22.55 Lakhs
Estimated cost
Bid Submission
20 Aug 2025
0 days left
EMD
45500
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
anpara → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Maintenance Work Of Firefighting System Of 3X210 Mw, Atps 2X500 Mw, Btps And 2X500 Mw, Dtps, Anpara
BOQ
| Sl. No. | Item Description |
| 1 | Complete overhauling & alignment of fire water pumps a. ATPS-01 Job b. BTPS-01 Job c. DTPS-01 Job |
| 2 | Complete overhauling & alignment of Jockey pumps a. ATPS-01 Job b. BTPS-01 Job c. DTPS-01 Job |
| 3 | Complete overhauling & alignmentof sump pumps a. ATPS-01 Jobb. BTPS-01 Job |
| 4 | Overhauling of Foam water mixture tank of auto fixed foam system a. BTPS-01 Job |
| 5 | Complete overhauling of Fire water pump motor a. ATPS-01 Jobb. BTPS-01 Job |
| 6 | Complete overhauling of Jockey pump motora. ATPS-01 Jobb. BTPS-01 Job |
| 7 | Complete overhauling of sump pump motor a. ATPS-01 Jobb. BTPS-01 Job |
| 8 | Complete overhauling of Air compressor motor 11 KW,0.4 KV,3 Phase a. ATPS-01 Jobb. BTPS-01 Job |
| 9 | Complete overhauling of Air compressor motor 3.7 KW,0.4 KV,3 Phase a. ATPS-01 Jobb. BTPS-01 Job |
| 10 | Replacement of damaged valve in fire fighting system by bringing valve from site store of size 450 mm and 400 mm gate valve and NRV a. ATPS-01 EA b. BTPS-01 EA |
| 11 | Replacement of damaged valve in fire fighting system by bringing valve from site store of size 80,100,150,200,250 and 300 mm gate valve and NRV a. ATPS-01 EA b. BTPS-01 EA c. DTPS-01 EA |
| 12 | Replacement of damaged valve in fire fighting system by bringing valve from site store of size 65,80,100 and 150 mm Deluge valve and alarm valve a. ATPS-04 EA b. BTPS-04 EA c. DTPS-04 EA |
| 13 | Complete overhauling of Gate Valve of size 500 NBa. ATPS-01 Job b. BTPS-01 Job |
| 14 | Complete overhauling of Gate Valve of size 300 NBa. ATPS-03 Job b. BTPS-03 Job |
| 15 | Complete overhauling of Gate Valve of size 250 NBa. ATPS-02 Job b. BTPS-02 Job |
| 16 | Complete overhauling of Gate Valve of size 200 NBa. ATPS-02 Job b. BTPS-02 Job |
| 17 | Complete overhauling of Gate Valve of size 150/100/80 NBa. ATPS-22 Job b. BTPS-22 Job |
| 18 | Complete overhaulingof NRV of size 500 NBa. ATPS-01 Job b. BTPS-01 Job |
| 19 | Complete overhaulingof NRV of size 300 NBa. ATPS-01 Job b. BTPS-01 Job |
| 20 | Complete overhaulingof NRV of size 150 NBa. ATPS-01 Job b. BTPS-01 Job |
| 21 | Replacement of damaged bearing including all related work alongwith its alingnment-400 M3/hr pump and motora. ATPS-01 Job |
| 22 | Replacement of damaged bearing including all related work alongwith its alingnment- 27 M3/hr pump and motora. ATPS-01 Job b. BTPS-01 Job |
| 23 | Replacement of damaged bearing including all related work alongwith its alingnment -15M3/hr pump and motora. ATPS-01 Job |
| 24 | Excavation of soil for attending leakage in pipe line of fire fighting system of soft soil a. ATPS-80 M3 b. BTPS-80 M3 c. DTPS-80 M3 |
| 25 | Excavation of soil for attending leakage in pipe line of fire fighting system of hard soil a. ATPS-45 M3 b. BTPS-45 M3 c. DTPS-45 M3 |
| 26 | Excavation of soil for attending leakage in pipe line of fire fighting system of cemented concrete a. ATPS-22 M3 b. BTPS-22 M3 c. DTPS-22 M3 |
| 27 | Refilling of soil after attending leakagea. ATPS-147 M3 b. BTPS-147 M3c. DTPS-147 M3 |
| 28 | Replacement of 450 mm NB size of pipe by cutting and weldinga. ATPS-07 M b. BTPS-07 M |
| 29 | Replacement of 400 mm NB size of pipe by cutting and welding a. ATPS-09 M b. BTPS-09 M c. DTPS-09 M |
| 30 | Replacement of 300 mm NB size of pipe by cutting and welding a. ATPS-11 M b. BTPS-11 M c. DTPS-11 M |
| 31 | Replacement of 250/200 mm NB size of pipe by cutting and weldinga. ATPS-17 M b. BTPS-17 M c. DTPS-17 M |
| 32 | Replacement of 150/100/80/65/50/40/32/25/15 NB size of pipe by cutting and welding a. ATPS-70 M b. BTPS-70 M c. DTPS-70 M |
| 33 | Replacement of 150/200 mm NB size of pipe by cutting and welding at a heighta. ATPS-15 M b. BTPS-15 M c. DTPS-15 M |
| 34 | Replacement of 80/100 mm NB size of pipe by cutting and welding at a heighta. ATPS-17 M b. BTPS-17 M |
| 35 | Replacement of sprinkler at height of 37 mtr. coal bunkera. ATPS-10 EAb. BTPS-10 EA |
| 36 | Attending Minor leakages of Pipelines by welding or Clamping.a. ATPS-40 Job b. BTPS-40 Job c. DTPS-40 Job |
| 37 | Bringing of heavy spares from one place to another place by tractor-trolly a. ATPS-01 EA b. BTPS-01 EA c. DTPS-01 EA |
| 38 | Brazing work of lug of landing valve or wedge nut of gate valve up to size 450mma. ATPS-01 Jobb. BTPS-01 Jobc. DTPS-01 Job |
| 39 | Repairing of damaged hose boxes and replacement of damaged glass a. ATPS-01 EA b. BTPS-01 EA c. DTPS-04 EA |
| 40 | Cleaning of sump pita. ATPS-01 Job b. BTPS-01 Job |
| 41 | Complete overhauling of air compressor type-FC-40 KG Khosalaa.ATPS-01 Job |
| 42 | Complete overhauling of air compressor type-30 Ingersol.ATPS-01 Job |
| 43 | Round/Routine maintenance of electrical, control and instrumentation of fire fighting system of ATPS & BTPS, Anparaa.a. ATPS-06 Jobb. BTPS-06 Job |
| 44 | Round/Routine mechanical maintenance of fire fighting system installed in ATPS & BTPS, Anparaa. ATPS-06 Jobb. BTPS-06 Job |
| 45 | Complete overhauling of Booster pump motor include shifting , dismantling , cleaning varnishing, assembling etca. BTPS-01 Job |
| 46 | Replacing the damage bearing of Booster pump motora. BTPS-01 Job |
| 47 | Bringing stator from store and replacement of damaged stator at the sitea. BTPS-01 EA |
| 48 | Routine/Preventive Maintenance work of mechanical system of Fire Fighting System including Fire Pump house, Foam Pump house, Hydrant System and Spray water System including Fire Fighting Systems of Switchyard of 2x500 MW, DTPS, Anpara.a. DTPS-181 Days |
| 49 | Sweeping and Cleaning of Fire Station Building & Safety Centre Building in 2x500 MW, DTPS, Anpara |
| 50 | Sweeping, Dusting of Furniture, Cleaning and wiping with wet cloth (Ponchha) of rooms of all floors of following building including galleries, lobbies including collection of garbage at specified place at ground level but beyond 100M distance including cost of all labours T&P etc. required for proper completion of work.a. DTPS-137 Job |
| 51 | Cleaning dust, dirt, jala (Cobweb) of rooms, galleries, walls, ceiling and other location of following buildings including cost of all scaffolding, T&P etc and also precautionary measures required for completion of work.a. DTPS-12 Job |
| 52 | Cleaning of aluminium/ iron glazed doors/ windows, partition walls etc of all rooms’ galleries, lobbies of following building including cleaning of glass panes by rubbing/ wiping with wet cloth/ spirit including cost of all materials, labour T&P etc required for proper completion work.a. DTPS-24 Job |
| 53 | Sweeping, Cleaning of Area surrounding the following buildings including washing of paved area, cleaning of grass including bushes and all kinds of wild growth and removal of rubbish from major fields etc to a distance of 50 m outside the periphery of area cleared as per scope of work annexed and direction of Engineer-in-charge (378 M²).a. DTPS-80 M² |
| 54 | Keeping neat & clean round the clock toilets at any elevation including washing floor fittings was basin, urinal Vim, Phenyl, Odo nil, Sani fresh or equivalent twice in a day and also cleaning of dust, dirt, daddies, cobweb etc. from the wall/ceiling also removing of choking including cost of all labour T&P, materials etc required for proper completion of work but excluding the cost of vim, phenyl, naphthalene harpic, which shall be supplied by free of cost. |
| 55 | Common Toileta. DTPS-637 EA |
| 56 | Attached Toileta. DTPS-113 EA |
| 57 | Sweeping and Cleaning of D V Houses in 2x500 MW, DTPS, Anpara |
| 58 | Sweeping, Dusting and Cleaning of all DV houses including collection of garbage at specified place at ground level but beyond 100M distance including cost of all labours T&P etc. required for proper completion of work. (Total No. of DV houses =62 & total Area of DV house=262M²)a. DTPS-06 Job |
| 59 | Upkeeping of Fire Trenches in 2x500 MW DTPS, Anpara and by means removal and disposal of garbage/Sludge/Ash/Coal etc. to suitable place.a. DTPS-2668 Job |
| 60 | Replacement of damaged bearing including all related works along with alignment for Hydrant Pump/Fire Pump 410 Cubic Mtrs per hour capacity.a. BTPS-01 EAb. DTPS-01 EA |
| 61 | Replacement of damaged bearing including all related works along with alignment for 75/10.8 Cubic Mtrs per Hour capacity Jockey pumpa. DTPS-01 EA |
| 62 | Transportation of valves of Fire Fighting System from store to site, Replacement of Valve and transportation of damaged valve back to store. |
| 63 | 600/400 MM Size Gate Valve or NRVa. DTPS-01 EA |
| 64 | 80/100/150/200/250 NB size Butterfly Valvea. DTPS-07 EA |
| 65 | Replacement of 600 NB size of pipe by cutting and weldinga. DTPS-06 M |
| 66 | Fabrication of Pipe bend by using of gas cutting etc. a. DTPS-50/Kg |
| 67 | Daily neccessity wise cleaning work on Fire Fighting pump house of walls, windows, cielings, doors,urinals room etc and grass cutting at different location of fire fighting systema. ATPS-06 Jobb. BTPS-06 Job |
AI Tender Summary
Tender Timeline
Aug 06, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 22, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender