Tender For External Electrification Work For 288 Nos. Pmay Houses At Barel District Barabanki - 1 S/Erection of 11 KV section Double pole structure (Riser) made of following types of supports duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) Plinthed, Plastered and painted in the same manner as already specified for respective supports with one nos. channels of size 100x50mm and 75x40mm M.S. channel and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. 2 Double Pole S.T. Pole SP-55, 11.00 M. Long 3 Supply of following Size 11 KV Standered Compacted Aluminium Conductor Screen with Extruded Semi conducting compound, XLPE Insulated, insulation screening with Extruded Semi conducting compoundin combination with Copper Tape, Cores laid up, innersheath of PVC, Galvanised steel strip Armoured & overall PVC sheathed cable confirming to IS 7098 ( Part-2) 2011 with up to date ammendments for proper completion of work Make (Polycab / Gloster/Finolex/Universal /KEI/ Havells) 4 120 Sqmm 3 core 5 Supply and jointing of 11 KV Indoor/Outdoor jointing kit (Heat Sink) per XLPE cable including cost of all material Labour and T & P as per proper completion of work as per direction of E/I. Make (Raychem/3M/ Densons) as per DSR 2022 S.No.10.4.2 & 10.5.2 6 185 Sqmm3core Outdoor Type 7 S/F of G.I. Pipe of following sizes for cable duly clamped with supports by 2 No. with clamps of 50 x 6 mm M.S. flats bolts, Nuts and washer required for proper completion of work. Make (TATA/SAIL/JINDAL) 8 100 mm dia (10.20 Kg/M) 9 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 140 mm 8.30 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 10 Drilling of Road Parallely & Road Crossing at a depth of 2 to 3 Mtr. as required & laying charges of cable & 140mm Dia HDPE Pipe complete with all material, labour, Drilling machine & required T&P etc. required for proper completion of work as per Direction of E/I. 11 Supply & Making of suitable earth of O/H line pole with 2.5 Mtr. Long 20 mm dia M.S. rod complete with 7/16 SWG G.S. wire in 2.00 Mtr. Long 15 mm dia G.I. Pipe (0.96 Kg/Mtr.) duly clamped on pole with 3 No.s 20 x 3 mm M.S. Flat clamp with bolts, nuts and washers complete with all material, labour and T&P etc. required for proper completion of work. 12 S/F of danger board of size 200 x 250 x 1.6 mm of M.S. sheet fixed with clamp of 20 x 3 mm M.S. flate including bolts, nuts and washer duly painted completed with all material, labour and T&P etc. for proper completion of work. 13 S/F of barbed wire (1.5kg) duly clamped with 2 No. clamps made of20x3mm MM. at both ends on poles flate including bolts, required for nuts and T&P etc. required for proper completion of work. 14 S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x100 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I. . 15 External Electrification Work Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) plinthed, plastered & painted in the same manner as already specified for respective supports sutable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per drawing and direction of E/I. 16 With 11 Mts. long 410 SP 55 S.T. Pole 17 Supply and Erection of 11 KV TPMO set complete in all respects ( as per Specification No. 21) 18 Supply and Erection of 11 KVD.O. fuse set complete in all respects. ( as per Specification No. 22) 19 Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightning arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work. 20 Supply, Installation, Testing and commissioningoffollowing size 11 /0.433 KV EnergyEfficient (Level-1)Copper wound, outdoor, Delta Star Distribution Transformer as per BIS 1180-2014 Standards. The rates also including loading, unloading, local carriage and T & P charges etc. 21 250 KVA, 11/0.433KV (Level-1) 22 Supply, installation, testing and commissioning of Outdoor Type,dust and vermin proof weather proof with rain canopy on four sideswith locking arrangement, 630A ACB L.T Panel Fabricated out of 2.0mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. All indicating lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The panel shall be completed in all respect and shall consist of following material.Incomer: 630AF.P Manual Fixed type A.C.B with Metering (ie Ameter with ASS, Voltmeter with VSS) along with, Phase Indicating Lights, CT,Control MCB etc. -1 Set Panel will have suitable rating (1Amp/Sqmm) of Aluminium Bas bar for Proper Temination of Cables. ( minimum 400 sqmm6 nos )All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. 23 630A 24 S/F of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required of proper completion of work as per direction of E/I. Page No. 25 Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henleys Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I. 26 Incoming : Two (2) Nos. 300 Amp.Fuse unit 27 Outgoing : Four (4) Nos. 300 Amp.Fuse unit 28 Supply Intallation testing and commissioning of 300Asub Feeder Pillar. The Feeder Pillar shall be fabricated outof 2.0mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of EngineerIn‐Charge after proper sheet treatment process of sheet steel. The Busbar of Panel shall be of High gradeElectrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation ofcontinuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of shortCircuit as fault level require. The Fault level of Panel shall be 50kA for 1sec. The Feeder Pillar shall be dust & Vermin Proof ,weather proof, rain canopy all four sides ,locking arrangements with Degree pf Protection IP : 55.The Feeder Pillar shall be completed in all respect and shall consist of following material.Incomer : 300A Kit Kat type Fuse Unit – 3 Set with Neutral Bus BarOutgoing: Suitable Bus Bar only with Provision to connect atleast 30 Nos. Outgoing Cables . up to3.5 core 35sqmm size 29 S/F/T&Cof capacitor control panel cubicle pattern, out door type ,sufficiently ventilated, dust and vermin proof weather proof with rain canopy on all four sides with locking arrangements,suitable for 440 V 3 phase 50 HzAC supplysystem complete with :- 30 FOR250KVATRANFORMERMCCB 160A 4P 36KA TMA [ incomer ] 1no . spreader160 A ext, rotary handle 160 A1 set indicating lamps3 nosMCB 6 A 1P 10 KA3 nos .ON / OFF/ TRIPindicatorsMCCB aux. Contact160 A1 NOVAF Meter 1 set .CT3160/5AAPFCrelay -12 stage1 set 200Aalu. Bus bar4 nos MCB 63 A 3P10 KA4 nos cap bank25 KVAR4 nos cap duty contactors 30KVAR 31 Construction of fencing plinth of following sizes in Ist class brick work including plaster and providing flat bricks soling and pointing the same with 1:2 cement and fine sand mortar over 75mm thick cement concreting in the ratio 1:6:12 in open space of the cage as per direction of E/I and drawing. 32 6x4x0.23m for Substation 33 Supply of fixing of 2.45M. High cage fabricated with 3.0mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0M to 1.25M. and horizontal members spaced at 1.20M the vetical members shall be grouted in ground and horizontal members in the wall to a depth of 300mm with ends folded. The cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3mm expanded metal wire mesh of equivalent weight duly fixed with the cage member. The cage shall have nut bolt arrangement for opening the sides by providing tees 45x20cm of angle iron size 50x50x6mm as per direction of E/I. It shall be painted with red oxide primer and synthetic enamelled paint as per direction of E/I. including all materials, labour and T & P for proper completion of work.PWD SOR 2018 SI No. 1142 34 Supply and burring of Safe Earthing Electrode T-39 ( Hot Dip Galvanized) Length up to 3000mm, outer Dia 76 mm inner 38 mm, terminal Dia 12mm, outer G.I. Pipe of 16 SWG & Inner G.I. Pipe 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm Square C.I. Frame with hinged cover & masonry housing.( from ElectrodeTerminal to switch board, cost of 25 x 3 G.I. Strip will be extra)As per PWD SOR-2018 S.I. No.-725 (D)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified 35 Construction of plinth for Transformer size 2.0x1.25x1.0 Complete With all materials, labour and T & P required for proper completion of work as per specification drawing and direction of E/I. Page No. 36 Supply & Laying of 120 Sqmm 3 Core standered Aluminium Conductor XLPE (Cross linked polyethylene) insulated PVC Bedded, Galvanised flat steel strip armoured cables confirming to IS 7098 (Part-II with latest ammendments) 11 KV Grade at a depth of 900mm below ground level over a cushion of 100mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc. as per PWD SOR 2018 S.No. 506 (f) Make Polycab/Gloster /Finolex /Universal /KEI /Havells 37 Supply of following size of Al. conductor XLPE Insulated, Cores Laid up, PVC Innersheathed, Armouredwith Galvanised Al. Strip Extruded PVC Type ST2 Outer Sheathed, 650V/1100 Volt Grade as per IS 7098 (Part I) 1988 With up to date Ammendments.Make Polycab / Gloster/ Finolex /Universal /KEI/ Havells 38 185 Sqmm 3½ core 39 Supply and laying of 240 Sqmm 3.5 Core Al. conductor PVC insulated armoured, served sheathed cable 1100V grade at a depth of 75cm. below ground level over a cushion of 75mm thick sand alround and protected with brick on sides And Top. On surface the cable run shall be fixed on M.S. clamp etc.of suitable size or as directed by the E/I. complete in all respect. The armouring of cable shall be properly connected with earth conductor by clamp etc. as per PWD SOR 2018 S.No. 501(t)Make Polycab / Gloster/ Finolex /Universal /KEI/ Havells 40 Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per PWD SOR 2018 SI No. 504 (h), (j), (m) 41 95 Sqmm 42 120 Sqmm 43 185 Sqmm 44 240 Sqmm 45 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouribg of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. as per PWD SOR 2018 S.No. 503 (o) & (r) 46 120 Sqmm 3½ core 47 240 Sqmm 3½ core 48 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 49 Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I. 50 S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x10 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I.Page No. 51 S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I 52 S/F of barbed wire (1.5kg) duly clamped with 20x3mm M.S. flats at both ends on steel poles at suitable height as per direction of E/I. 53 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of Cat. A & B Only. 54 NCOMING800 Amp /415Volt ACB-1 No 55 OUTGOING 400 Amp MCCB-1 Nos, 200 Amp MCCB- 2 No &63 Amp MCCB-1 No(ii) Cat. B Pannel Cubicle Type 56 Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing UPPWD SOR-2018 item no. 726 (D) 57 Supply & Laying of 32mm x 6mm G.I. Strip from earth electrode directly in the ground as required complete in all respect as per PWD SOR 2018 S.No. 717