| 1 | Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed |
| 2 | Material and labour for point wiring for one light / Fan / Ex Fan pointcontrolled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including MS rectangular Box with bakelite sheet cover / PVC rectangular switch board of suitable size for mounting switches, sockets, fan regulators etc or MS modular boxes / PVC modular box suitable for mounting modular switches, sockets etc including testing on completion complete all as specified and directed. |
| 3 | All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. |
| 4 | All as per Item No 2 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. |
| 5 | All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed |
| 6 | Material and Labour forsub main wiring with 2 run of single core 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit / casing capping of suitable size along with accessories etc including one run of 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length. |
| 7 | Material and Labour forsub main wiring with 2 run of single core 4.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit / casing capping of suitable size along with accessories etc including one run of 4.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 4.0 Sqmm single core cable, one run of 4.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length |
| 8 | Supply and fix in repair PVC casing and caping of size 32 x12 mm complete all as specified and directed. |
| 9 | Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed |
| 10 | Supply and fix socket outlet 5 pin, 6 Ampscomplete all as specified and directed |
| 11 | Supply and fix Switch Socket combination 2 in 1, 6A flush type5 pin, 230 volts complete all as specified and directed |
| 12 | Supply and fix Switch socket combination 2 in 1,3 pin, 6 amps and 16 amps flush type universal shuttered, complete all as specified and directed |
| 13 | Supply and fix Ceiling rose, 2 pole / 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed |
| 14 | Fixing only serviceable Ceiling rose, 2 pole / 3 pole, PVC / polycarbonate, insulated bodycomplete all as specified and directed |
| 15 | Supply and fix Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps(ISI Marked), complete all as specified and directed |
| 16 | Supply and fix modular switch 1 way 6 Amps 1 Module complete all as specified and directed |
| 17 | Supply and fix modular switch 1 way 16 Amps 1 Module complete all as specified and directed |
| 18 | Supply and fix modular socket2 in 1,5 pin 6 Amps, 2 modules complete all as specified and directed |
| 19 | Supply and fix modular socket2 in 1,3 pin 16 Amps, 2 modules complete all as specified and directed |
| 20 | Supply and fix Modular Fan regulator,100 watts 2 modules complete all as specified and directed |
| 21 | Supply and fix white modular cover plate with frame 3 Module complete all as specified and directed |
| 22 | Supply and fix white modular cover plate with frame 8 Module complete all as specified and directed |
| 23 | Supply and fix sheet metal enclosure MCB DB 4 waySPN double door suitable for 240 V, fixed on walls includingblanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. Note for fixing of Dbs item no 23, 24, 25, 26, cement mortar ratio 1:4 required and match with existing colour after apply of wall putty will be inclusive of quoted rate. |
| 24 | Supply and fix sheet metal enclosure MCB DB 8 waySPN double door suitable for 240 V, fixed on walls includingblanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. |
| 25 | Supply and fixin repair MCB DB 4 Way TPN double door factory made suitable for incorporating MCB as out going and MCBs as incoming , fixed on walls including elctrical connection, blanking plate as per requirement and taking down unserviceable DBs complete all as specified and as directed. |
| 26 | Supply and fix MCB DB,TPN8 way, double door vertical with 200 Amp rated bus bar , fixed on walls including elctrical connection, blanking plate as per requirement and taking down unserviceable DBs complete all as specified and as directed. Note for item no 8 to 12 for fixing of DBs cement morter ratio 1:6 required will be inclusive of quoted rate. |
| 27 | Supply and fix MCCB 4 Pole, 415 Volts, 63 Amps, breaking capacity 16 KA complete all as directed. |
| 28 | Supply and fix MCB, TPN, AC, 415 volts IP-43 of40 Amps capacity \"C\" series and making connections incl taking down unsv one complete all as specified & directed. |
| 29 | Supply and fix MCB SP 240 Volts, \"C\" series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed |
| 30 | Supply and fix miniature circuit breaker (MCBs) SPN , 240 Volt, 32 Amps, \"C\" series,10 KA breaking capacity, complete all as specified and directed |
| 31 | Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SP obtained from unserviceable DBs shall be reused) complete all as specified and directed |
| 32 | Fixing only Minature circuit braker (MCBs) of any cap, 240 Volt (serviceable MCB SPN obtained from unserviceable DBs shall be reused) complete all as specified and directed |
| 33 | Supply and fix in repair LED tube light fittings 1 x 09/10 Watt two feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 34 | Supply and fix in repair LED tube light fittings 1 x 18/20 Watt four feets long with polycarbonate housing & intigrated electronic driver and necessary electric connection complete all as specified and as directed |
| 35 | Supply and fix in repair wallmountedbulk headLED light fitting 10 W, made up of poly carbonate housing with diffuser & intigrated electronic driver and necessary electric connection complet all as per specified and directed |
| 36 | Supply and fix in repair indoor commercial LED Luminaires Plano 2ftX2ft 36 watt ultra modern recess mounting luminaire with high performance LEDs suitable for mounting with grid ceilingand including connecting up with twin core twisted flexible copper conductor cable includingtaking down old light fittings complete all as specified and directed. |
| 37 | Supply and fixing in repair switch socket combination5 Pin 6 Amp with PVC Box complete all as specified and directed. |
| 38 | Supply and fixing in repair switch socket combination3 Pin 16 Amp with PVC Box complete all as specified and directed. |
| 39 | Supply and fix in repair white modular cover plate with frame 3 Module complete all as specified and directed |
| 40 | Supply and fix in repair white modular cover plate with frame 6 Module complete all as specified and directed |
| 41 | Supply and fix in repair white modular cover plate with frame 8 Module complete all as specified and directed |
| 42 | Supply and fix in repair Switch piano flush button single pole, one way 5 Amp,complete all as specified and directed |
| 43 | Supply and fix in repair modular switch 1 way 6 A, 1 Module complete all as specified and directed |
| 44 | Supply and fix in repair sheet metal encloser box including Plug and socket with 20 Amps MCB (SP) complete all as specified and directed |
| 45 | Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth wire 4 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as directed. |
| 46 | Supply and fix of Earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire complete all as specified and directed. |