Supply Of Items Under M-Aay, Cm-Nnry And Rghs Scheme For Cardiology Department (Rate Contract For 1 Year) , Angio Guidewire 0.035 – J/ 0.032 J-Tip 260 Cm Usfda/Ce/Dcgi Approved , Angio Guidewire– J-Tip 260 Cm With 0.035*260 Cm, 0.032, 0.038, 0.025, 0.018 Straight/ Angled/1.5 Mm J Shape Hydrophilic Guide Wire With Mcoat Technology Tapered Tip (Exchange Length) Single Nitinol Core Alloy Tungsten-Infused Polyurethane Jacket Must Be Available In Standard And Stif Usfda/Pmda Approved , Angio Guidewire– J-Tip 150 Cm With Nitinol Core 0.035*150 Cm Usfda/Ce/Dcgi Approved , Angio Guidewire– J-Tip 150 Cm With 0.035*150 Cm, 0.032, 0.038 Hydrophilic Guide Wire With Mcoat Technology Tapered Tip (Regular Length 150,180 Cm) Single Nitinol Core Alloy Tungsten-Infused Polyurethane Jacket Must Be Available In Standard And Stif Usfda/Pmda Approved , Angio. Cath. Al1/ Al2/ Al3 – 5F, 6F Usfda/Ce/Dcgi Approved , Angio. Cath. Ar1/ Ar2/ Ar3 – 5F, 6F Usfda/Ce/Dcgi Approved , Angio. Cath. Jl -3.5/4.0/4.5/5.0 (5F & 6F) Ce / Dcgi Approved , Angio. Cath. Jr. 3.5/4.0 (5F & 6F) Ce / Dcgi Approved , Angio. Cath. Pigtail 4F/ 5F/ 6Fusfda/Pmda/Dcgi/Ce Approved , Ima - 6F/ 7F Usfda/Ce/Dcgi Approved , Multipurpose6f, 7F Usfda/Ce/Dcgi Approved , Peadiatric Input Sheath 4F/ 5F Usfda/Ce/Dcgi Approved , Radial Sheath 5F/ 6F With Puncture Needle – Standard Length 20*2 G (Plastic Iv Catheter) And 0.025 Mini Elastic Guide Wire. Radial Introducer Sheath With Unique Cross Cut Design, Haemostatic Valve With Integrated Side Arm With Attached 3 Way Stop Cock Must Have Etfe Sheath Tubing Polypropylene Dialator Tube With Silicon Coating Us Fda & Pmdaapproved , Two Locking Mechanism (A) Snap On /Click Off (B) Rotating Type. Have Unique Intro Cross Cut Valve Which Maintain Uncompromised Hemostasis To Avoid Bleeding. Radial Sheath 5F/ 6F Or Equivalent Ce/ Dcgi Approved , Tiger Shaped 5F/ 6Fangiography Catheter-Trans Radial Catheter Must Have Shapes Designed To Cannulate Right And Left Coronary Arteries Tig, Tig-Ii, Jacky, Sarah Must Have In A Diameter Of 5F-1.20Mm, 6F-1.30Mm Us Fda And Japan Pmda And Dcgi Approved , Tiger 5F/ 6F Catheter Equivalent Tig 2 Inner Diameter To 0.050 Or More With Maximum Pressure Upto 1200 Psi. Ce/ Dcgi Approved , Dye (Non-Ionic Contrast Agent 100Ml It Should Be Us Fda/Ce & Dcgi Approvediohexol As Salt Name With 350 Mg/Ml Concentration , Iodixanol As A Salt Name 320Mg/Ml With Plastic Bottle With Hanger 100Ml Pack Usfda/Ce/Dcgi Approved , Femoral Sheath With Puncture Needle 5 F, 6F, 7F, 8F, 9F, 10F, 11F, All Size (Length) Ce/Dcgi Approved , Unilock Syringe 10 Ml , Iv Cannula (18,20,22 G) , Disposable Ecg Electrodes For Adults- Us Fda/Ce & Dcgi Approved • Adult Diaphoretic Foam Electrodes. • Should Be Pre-Gelled, Peel And Stick Electrode With Excellent Adhesion • Should Have No Residue Once Removed • Should Conform To Or Exceed The Highest Industrial Standard For Ecg Electrodes, Quality Certification From Authorized Agencies To Be Provided , Cd – R Media With Atleast 700 Mb Storage And Atleast 52X Recordable Speed Dvd , Pressure Monitoring Line 200Cm , Manifold ( Two Port ) Usfda/Ce/Dcgi Approved , High Pressure Line - 200 Cm , Dvd , Docking Wire , Swan Ganz Catheter - Ce Approved - 6F/7F Us Fda/ Ce And Dcgi Approved , Gadoteric Acid 10 Mlvial With Usfda Approved , Gadotericacid20 Ml Vials With Usfda Approved , Radial Artery Haemostasis Device- (T.R. Band) Consists Of Two Balloon Specially Designed For Spot Compression Of The Radial Puncture Site. Must Have Belt Magic Tape For Fast Application ·Must Have Curved Support Plate. Must Have Green Positioning Marker. ·Must Be Available In 2 Sizes – 24Cm And 29Cm Usfda+Pmda Approved· , Special Slender Sheath (Gss) Must Have Unique Thin Wall Technology Reducing The Outer Diameter By 1· Fr Size Whilst Maintaining The One Size Lager Inner Diameter.Must Have 7Fr Sheath With Outer Diameter Of 2.8Mm, 6Fr With Od Of· 2.46 Mm & 5Fr With Od Of 2.13Mm. Hydrophilic M Coating With 20/21G Surflash Needle And Tif Tip· Technology Which Provide Optimal Tapering Design. Usfda/Pmda Approved , Cto Approachable Slender Profile Hydrophilic Radial Introducer 4F-7F Ce/ Dcgi Approved , Baby J Wire (180Cm & 300Cm) With Radius Of 1.5Mm J Tip, (Regular Length) • Must Have Tungsten Infused Polyurethene Jacket • Baby J Curve Must Have Radius Of 1.5 Mm • Super Elastic Nitinol Alloy, M Coat Hydrophilic Coat • One Piece Construction For 1:1 Torque And Radio Opaque Polyurathin Jacket • Usfda/Pmda Approved , Diagnostick Femoral Catheter Consistant Id From Hub To Tip , Stainless Steel Wire Braided Body Wraped With Thrombi Resistant Material Colour Course For Easy Fr. Size Identification Soft, Atromatic, Radio Opaque Tip 4F/5F/6F Length 65/80/100/110/125 Cms, Curve 3.5,4,4.5 Jl/Jr/Al/Ar Src, 3Drc, Straight, Pig Tail, Im Usfda/Pmda Approved , (A)Judkins Guiding Catheter (Jr Jl & Pigtail Ebu, Xb,Xbr(Terumo, Cordis, Meditronic, Boston Scientific, Translumina Or Equailant Quality) Us Fda/Ce & Dcgi Approved 4 French/5 French /6 French/7 French/8French Size Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Micro Catheter To Be Used For Cto Antegrade And Retrograde Approach Usfda/Ce/Dcgi Approved , Ptca Guide Catheter Uniform Diameter From Hub To Tip Catheter Range Should Have Short Tip, Long Tip (16Mm Long) For Active And Passive Support, Side Holes Ptfe Lining Tip Should Be Radio Opaque Large Lumen. Diameter 5, 6, 7, 8, 9 Frlength 55Cm/ 90Cm/ 95Cm/ 100Cm Specility Shapes Lcb, Im, Rcb, Mpa, Hockey Stick Usfda/ Pmda Approved , Special Guiding Catheter Must Have Ikari Curve Radial Curve Stainless Steel Flat Wire Braid High Strength Wired Braided Catheter With Inner Layer Of Ptfe With Flouro Polymer Must Havelarger Lumen 6 Fr Id-0.71” Usfda/ Pmda Approved , Angled Pigtail Cathter 110 Cms 5 And 6Fr 145 Degree Angle And Both 6 And 12 Side Holes Usfda/Pmda Approved , Cournard Guidingcatheter Us Fda/Ce & Dcgi Approved • 4 French/5 French /6 French/7 French/8French In Various Standard Curves And Lengths. , Double Lumen Thrombo-Aspiration Catheter , Vascular Closure Device With Bio Absorbable Pga Suture That Provide A Secure Seal, , Bioabsorbable Collagen Designed To Conform To The Arteriotomy For Confident Closure, And Low Profile Bioabsorbable Anchor (50:50 Blend Glycolideandlactidepolyer) To Fit Closely Against Arterial Wall Leaving Blood Flow Undistributed While Maintaining Vessel Diameter. Againt . , Ptca Inflation Device- Us Fda/Ce/ Dcgi Approved Efficient Locking System To Maintain High Pressure Rapid Inflation And Deflation Clear Barrel For Easy Visualization Of De-Bubbling Luminescent Analog Pressure Gauge (Up To 30 Atm) Ergomatric And Use Friendly Hand Held Design. , Y Connector With Dual Valve, One With Push-Pull Other With Screw Type With 10Fr Compatible Inner Dia Meter 3.25 Mm And 90 Mm Length. , (Haemostatic Y-Connector) For Ptca – Push Mechanism - Us Fda/Ce/ Dcgi Approved Should Accommodate Virtually All Interventional Devices Luer Connector At The Guiding Catheter End Rotating Adapter At The Guiding Catheter End Should Have Bleed Back Safety Mechanism Stepwise Control For Open, Semi-Open And Closed Position , Hydrophilic Guidewire(Exchange Length) With Mcoat Technology Tapered Tip, Single Nitinol Core Alloy, Tungsten-Infused Polyurethane Jacket • Hydrophilic Polymer Coat. •One Piece Construction & Radiopaque Polyurethane Jacket. •Must Be Available In Standard And Stiff. •Must Be Available In .035, .032, .038, .025, .018 Diameter And 260 Cm Length - Straight / Angled / 1.5 Mm J Shape •Usfda And Pmda Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 28Cm Tip Load 0.7 Gm 180 Cm Length Tip Radiopacity 3 Cm Usfda/Ce/Dcgi Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 20Cm Tip Load 0.5 Gm 180 Cm Length Tip Radiopacity 3 Cm Usfda/Ce/Dcgi Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil With Sion Technology Having Composit Core With Actone Inside Length 22Cm Polymer Sleee Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 0.8 Gm 180 Cm Length Tip Radiopacity 3 Cm Usfda/Ce/Dcgi Approved , .014” One Piece Core Workhorse Wire With Jointless Spring Coil 22 Cm Polymer Sleev Length With Slip Coat Coating Over The Polymer Sleeve Tip Load 1Gm 180 Cm Length Tip Radiopacity 3 Cm Usfda/Ce/Dcgi Approved , Extra Support 0.014Wire; 0.7 Gf Tip Load Tip Radio Opacity 4 Cm 180 Cm Length Ptfe Coating Over The Shaft Silicone Coating Over Spring Coil Usfda/Ce/Dcgi Approved , Ptca Guide Wire Durasteelstainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 1.5 Gm To 4.1 Gm, Hydrophilic Coating. Usfda/Dcgi Approved , Ptca Guide Wire – Core Material Elastinite Nitinol For Excellent Flexibility And Durability, Shaping Ribbon For Excellent Shape Retention And Atraumatic Tip Load Less Than 0.65 Gm With Regular Length, Regular Shaft Support And Floppy Tip , Ptca Guide Wire Durasteelstainless Steel For Durability And Excellent Torque Control, Full Polymer Jacket Core To Tip Design For Precise Steering And Tip Control, Various Tip Loads 0.8 Gm To 1.2 Gm, Hydrophilic Coating. Usfda/Dcgi Approved , Steerable High Support 0.014-Inch Guide Wire(180 Cm Long)Ptee/Dura Glide Coateddistal Radio Opaque Tip 3 Cm Long Straight And J Curve , Regular Workhorse Guidewire With Responsease Core Grind Technology And 3Cm Palladium-Rhenium Radiopaque Distal Tip Available In Tipload Of 0.8Gm In 190Cm And 300Cm Lengths . , .014 One Piece Core Workhorse Wire With Jointless Spring Coil With Tapering To .009” 0.8Gf Of Tip Load; 16 Cm Plymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, 190 Cm Length Tip Radiopacity 16 Cm Usfda/Ce/Dcgi Approved , .014 One Piece Core Cto Wire With Jointless Spring Coil Ptfe Coating Over The Shaft, Tip Load 3G, Tip Load 3G, 4.6 G And 12G, 180 Cm Length With Tip Radiopacity 11 Cm Usfda/Ce/Dcgi Approved , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 9G 180 Cm Length Tip Radiopacity 20 Cm Usfda/Ce/Dcgi Approved , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009” Tip Load 12G 180 Cm Length Tip Radiopacity 20 Cm Usfda/Ce/Dcgi Approved , One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .008” Tip Load 20G 180 Cm Length Tip Radiopacity 17 Cm Usfda/Ce/Dcgi Approved , .010” One Piece Core Wire With Joint Less Spring Coil Length 15 Cm Cone Tip With A Tip Load Of 3.5 Gm 190 Cm Length Tip Radiopacity 15 Cmusfda/Ce/Dcgi Approved , Ns Ptca Wire Floppy. Extra Floppy Intermediate & Hypercoat Including Cto Wires .014Diameter Ptca Wires With Directly Jointed Sus And Nitinol Shaft Through Duocore Technology For Superior Torque Transmission Available In Various Tip Loads- Us Fda And Japan Pmda And Dcgi Approved , Extra Floppy Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180/300 Cm Length•Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint.•Must Have Ptfe Coating From 25 To 180 Cm Length. & Mucus Coat Hydrophilic Coating Up To 248 Mm·Should Have 0.6-Gram Force Tip Loads ·Usfda+Pmda , Floppy Tip Ptca Guide Wire – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length.•Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating •Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint. •Must Have M Coat Hydrophilic Coating Up To 248 Mm,& Ptfe Coating From 25 To 180 Cm Length. •Should Have 1 Gram Force Tip Loads •Usfda+Pmda , Hypercoat Ptca Guide Wire With 9.7-Gram Force Rail Support– Mucus Coated Hydrophilic Distal Tip, 0.014” Diameter And 180/300 Cm Length•Must Have Platinum Coil At Distal Tip. 14 Mm Tip Shape Length.•Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint.•Must Have M Coat Hydrophilic Coating Up To 250 Mm & Ptfe Coating From 25 To 180 Cm Length.•Should Have 1-Gram Fore Tip Load•Usfda+Pmda , Cto Stiff Ptca Guide Wire - 3.6-Gram Force Tip Load – 2 Mm Silicon Coated Distal Tip, 0.014” Diameter And 180 Cm Length.•Must Have Platinum Coil At Distal Tip. Balance Of Hydrophilic And Hydrophobic Coating•Must Have Directly Jointed Sus And Nitinol Shaft Through Duocoretechnology And Silicon Coated Joint.•Must Have M Coat Hydrophilic Coating Up To 248 Mm & Ptfe Coating From 25 To 180 Cm Length.•Should Have 3.6-Gram Fore Tip Load•Usfda+Pmda , Workhorse Guidewire With Triple Spring 304V Stainless Steel With Niti Distal Core And Cold Working Rotary Swagging Tip Available In Tiploads Between 0.6-0.8 Gm And Lengths (190/300 Cm) Us Fda/Ce & Dcgi Approved , Workhorse Guidewire With Durasteel Core, Responses Core Grind Technology With Hydrophilic Coating And 1Cm Uncoated Distal Tip For Tactile Feedback Available In Multiple Variants With Same Tiploads Of 0.9Gm Us Fda/Ce & Dcgi Approved , Core Material Elastinitenitinole For Excellent Flexibility And Durability, Shaping Ribbion Forexcellent Shape Retention And Atraupatic Tip Load Less Than 0.65 Gm With Regular Length, Regular Shaft And Floppy Tip. Sfda/Ce/Dcgi Approved , Cto Indicated Penetration Guide Wire For Antegrade Wire Escalation (Awe) Technique With Unique Micro Textured Tip For Cap Engagement And Tapered Tip For High Penetration Powers. Tip Load 11 To 14 Gm Penetration Power – Above 160 Kg/In2 Us Fda/Ce & Dcgi Approved , Amplatz Wire – Ptee Coated – (Regular Length) .035Large Stainless Steel (Ss) Core With Ss Flat Wire Coils Gradual Taper With Core To Tip Support And Flexibility For Atramatic Navigation Trough Frotuous Anatomy Usfda/Ce/Dcgi Approved , Aspiration Thrombectomy Catheter• Available In Size 6F, 7F Both, Must Have Entry Profile 0.019 Inches• Must Have 1.30 Mm Square Suction Area• Braided Polyamide Elastomer Shaft, Stainless Steel Wire Braiding And Guide Wire Type Stylet,• 6.0Mm Tip Length For Making Aspiration Inlet To Come Closer To The Target Thrombus And 10Cm-Length Depth.• Must Have Distal 40 Cm Hydrophilic Coating.• Pmda/Usfda/Ce/Dcgi Approved , Dedicated Dual Lumen Micro Catheter For Side Branch Access Usfda/Ce/Dcgi Approved , Thrombus Aspiration Catheter With Removable Core Wire And 30Cm Hydrophilic Coating From The Tip; Available In 6F And 7F Usfda/Ce/Dcgi Approved , Guidewire Support Microcatheter With Advanced Hydrophilic Coating And Unique Shaft Design That Has Fluoro-Resin Inner Surface To Provide Reinforced Lubricity; Advanced Braiding Technology In The Shaft Of The Microcathetr.Tip Profile - 1.4 Fr, 1.5 Fr Distal Profile - 1.7 Fr, 1.8 Fr Length: - 135Cm, 150Cm Usfda/Ce/Dcgi Approved , Coronary Guide Wire Stainless Core, Actone Technology, Polymer Jacket With Hydrophilic Coating, Tip Load 3Gm, Radiopaque Length 3Cm, Spring Coil 8.5Cm Having 190Cm & 300Cm. Usfda/Ce/Dcgi Approved , Coronary Guide Wire Stainless Core, Actone Technology, Polymer Jacket With Hydrophilic Coating, Tip Load 3Gm Radiopaque Length 3Cm, Spring Coil 3Cm Having 190Cm & 300Cm With St Tip & Pre Shape. Usfda/Ce/Dcgi Approved , Coronary Guide Wire Stainless Core, Actone Technology, Polymer Jacket Length 40 Cm With Hydrophilic Coating 50 Cm, Tip Load 3Gm, Radiopaque Length 3Cm, Spring Coil 11Cm Having 200Cm & 300Cm With St Tip & 1Mm Pre Shape. Usfda/Ce/Dcgi Approved , Ptca Balloon (Semi-Compliant) - Us Fda/Ce & Dcgi Approved Monorail (Rapid Exchange) And Over-The-Wire (Otw) Balloons Available In The All (1Mm To 4Mm Diameter) Sizes And Lengths , Ptca Balloon (Non-Compliant) -Us Fda/Ce & Dcgi Approved Quote Both Monorail (Rapid Exchange) And Otw Balloons Available In All Sizes From 2 - 4.0 Mm, Variable Lengths Should Have A Very High Rated Burst Pressure , Ptca Balloon Ultra Lowentry Profile Balloon With 0.016 Entry Profile, Thin Marker Of 25Micro Milimeter And Core Wire Shaft For Batter Pushabilty With Widerange From 1Mm To 4Mm Diameter. Usfda/Ce/Dcgi Approved , Ptca Balloon Semi Compliant Cto Balloon With Ultra Low Entry Profile With 0.40Mm Or 0.016 And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Crossablity Even With Higher Diameter Balloon. Usfda/Ce/Dcgi Approved , Semi Compliant With Lesion Entry Profile .016” And Shaft With Special Push And Track Technology, Diameter Available 1.5Mm – 3Mm, Length Available 8Mm – 20Mm, Np 6 Atm, Rbp – 14 Atm Usfda/Ce/Dcgi Approved , Sirolimus Drug Eluting Balloon With Nano Carriers Ce Marked , Drug Coated Balloon - Drug Coated Balloon With 2 ?G/Mm2 Dose Of Paclitaxel With Polysorbate& Sorbitol As Carrier Which Will Deliver An Optimal, Therapeutic Drug Dose To The Target Vessel Wall After A Minimum 30 Second Inflation Time. Available In Sizes- 035 Guidewire Compatible – 120 Cm Shaft - 4Mm -6Mm Dia, Lengthupto 150Mm, 035 Guidewire Compatible – 75Cm Shaft – 5Mm – 12 Mm Dia, Length 60Mm, 014 Guidewire Compatible – 150 Cm Shaft – 2Mm To 3.5Mm Dia, Length 120 Mm Wing Seal Technology Usfda/Ce/Dcgi Approved , High Pressure Ptca Dilatation Catheter With Small Entry Profile Of 0.43Mm And Small Balloon Profile Of 0.034” With Special Silicon Coating On Balloon To Avoid Mellon Seed Effect. Small Distal Shaft Profile Of 2.5-2.6Mm To Allow Kbt In 6Fr Large Lumen Guiding Catheter. Usfda/Ce/Dcgi Approved , Lesion Entry Profile - 0.016/Nominal Pressure - 12 Bars/Rbp - 22 Bars/Impeccable Tip/Hydrophilic Coated/ Non-Compliant Balloon/ Prime Shaft Usfda/Ce/Dcgi Approved , Dual Layer/Rbp 35 Bars/Abp 45 Bars/Strictly Non-Compliant Usfda/Ce/Dcgi Approved , Ptca Balloon (Semi Compliant) – (Usfda Approved) Monorail, Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size 1.2,1.5,1.2 Push, 1.5 Push, 2-4Mm Dia X 8,12,15,20,30 Lengths , Ptca Balloon (Non Compliant) Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143 Cm Size - 2-6Mm Dia X 6,8,12,15,20,30 Lengthsusfda & Dcgi Approved , High Pressure Non-Compliant Balloonwith Innovative Triple Layer Balloon Technology With High Pressure Resistance Of 22 Atm. Must Have Elastomer Outer Layer, Middle Layer Of Polyamide And Inner• Most Layer Of Elastomer. Must Have Nominal Pressure Of 12Atm And Rbp Of 22Atm. •Shorter Thin Distal Tip Of 2.9Mm With Low Entry Profile Of 0.43 Mm. Must• Have Hydrophilic Mucus Coating Must Have 3.0 Mm Short Taper Balloon Shoulder•& Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile.Must Have 2.6 French Stainless Steel Core Wire Structured Shaft•& Stainlesssteel Stylet In Mid Shaft. Must Have Hypotube Without Ptfe Coating. Must Have Three Pleats Re-Wrappable Structure. Pmda+Ce Approved• , Cto Balloon With Ultra – Ultra Low Entry Profile Of 0.016 Must Have Hydrophilic Mucus Coating. •Should Have Smallest Diameter 1.00Mm And 5Mm Length. •Must Have 0.8Mm Shorter And 25?M Thinner Radiopaque Marker For Lower Crossing Profile. •Must Have Flexible Tip With Short Balloon Bonding Part Of 0.4Mm. •Nominal Pressure Of 06 Atm And Rbp Of 14 Atm •Must Have 2.4 To 2.7 French Tapered Stainless Steel Core Wire Structured Shaft. •Must Have Three Pleats Re-Wrappable Structure. •????Pmda+Ce Approved , Dual Layer/ Rbp 35 Bars/ Strictly Non-Compliant (Only 10% Growth)/ Andfor Super High Pressure Ptca, A Manometer Of 55 Atm Usfda/Ce/Dcgi Approved , Cto Nc Balloon Diameter 0.85 Mm Entry Profile .016 Rbp 21 Hydrophilic Single Proximal Marker. Usfda/Ce/Dcgi Approved , Semi-Complaint Ptca Balloon With Smallest Entry Profile Of 0.0157, Tapered Balloon Shape, Unique Tri-Fold Wrapping Technology, Tr2 Hydrophilic Coating; Available In Lowest Profile 1 Mm Diameter, Longer Shaft Length Of 146Cm. Usfda/Ce/Dcgi Approved , Non-Compliant Ptca Balloon With Highest Rbp Up To 22 Atm; Tapered Balloon Tip To 4Mm With Lowest Shoulder Angle To 32 Deg; Available In Lowest Profile 1.5Mm Diameter, Longer Shaft Length Of 146Cm. Usfda/Ce/Dcgi Approved , Special Ptca Balloon (Non-Compliant) For Post Dilation. Must Have Diameter Starting From 1.75 Mm-5.0 Mm. Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail (Rapid Exchange) Balloon. Ce Approved , Cutting Balloon For Ptca Having Microsurgical Atherotomes (Blades) - Us Fda/Ce & Dcgi Approved· Monorail (Rapid Exchange) And Over-The-Wire (Otw) Balloons Available In The Sizes And Lengths , Wire Based Scoring Balloon Cathethr. Us Fda/Ce & Dcgi Approved Available In The Sizes And Lengths Monorail (Rapid Exchange) , High Pressure Semi Complaint Ptca Balloon Must Have Low Entry Tip Profile Equal To Or Less Than 0.016 Should Have Nominal Pressure 6 Atm Or Above And Rbp Above 14 Atm Must Be Available In Diameter 1.0 Mm Along With Other Size Matrix Starts Form Diameter 1.75 Mm To 4 Mm Quote Both Monorail And Otw Balloon Us Fda/Ce & Dcgi Approved , Special Ptca Balloon (Non Complaint) For Post Dilations Must Have Diameter Starting From 1.75 Mm To 5.0 Mm Balloon Material Must Be Nylon For Controlled Compliance. Quote Both Monorail And Otw Balloon Us Fda/Ce & Dcgi Approved , Usfda Approved Semi-Complaint Coronary Balloon With Slim Seal Technology On Distal Tip With Crossing Profile Of 0.021”, Lesion Entry Profile Of 0.017” And Microglide Coating Available In Diameter 2.25-5.00Mm And Lengths 6-30Mm , Non-Complaint Coronary Balloon With Tri-Fold Layers And Tip Entry Profile Of 0.018” Diameter 1.5Mm To 5.0Mm & Length 6Mm To 25Mm With Skive Technology On Mid Shaft Excellent Flexibility And Tight Rewrap With Flat Compliance For Excellent Stent Apposition. Us Fda/Ce & Dcgi Approved , Cto Indicated And Usfda Approved Semi-Complaint Balloon With Slim Seal Technology On Distal Tip With Lesion Entry Profile Of 0.017, Crossing Profile Of 0.021 And Single Flexible Tungsten Marker Available In Unique Diameter Of 1.2Mm With Variety Of Lengths , Special Ptca Balloon Non-Complaint Coronary Balloon With Multilayer Crossflex Balloon Technology And Round Tip With Lesion Entry Profile Of 0.018” Available In Diameter 1.5Mm To 5.0Mm & Length 6Mm To 25Mm With Skive Technology On Mid Shaft. Us Fda/Ce & Dcgi Approved , Drug Eluting Balloon Paclitaxel Coated, Unique Coating Technology With Pvp As Drug Carrier, Wing Seal Technology For Minimum Drug Loss During Transition, M3i Technology Ensuring Drug Release Up To 3 Times With The Same Device When Clinically Indicated .Eu Certified Sizes Diameter-2.00Mm, 2.5Mm, 3.00Mm, 3.5Mm, 4.00Mm Length-10, 15, 20, 30 Usfda/Ce/Dcgi Approved , Ptca Balloon (Semi Complaint) – (Usfda Approved) Monorail, Bi Segment Inner Lumen Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft – 2.6Fr, Distal Shaft- 2.3Fr, Balloon Material Opti Leap. Delivery System Working Length 143Cm Size 1.2, 1.5, 1.2 Push, 2-4Mm Dia X 8,12,15,20,30 Lengths , Ptca Balloon (Non Compliant) – (Usfda Approved) Bi Segment Inner Shaft, Monorail Catheter, Z Glide Coating, Proximal Shaft- 2.6 Fr, Distal Shaft – 2.3 Fr, Balloon Material Opti Leap, Delivery System Working Length 143Cm Size – 2-6Mm Dia X 6,8,12,15,20,30 Lengths , Ptca Guide Wire – (Usfda/Ce Approved) Entry Profile Diameter 0.014” And Compound Taper Stainless Steel Core, Inner Coil Technology, Spring Coil Cover With Coil Length Of 20Cm, Moderated Hydrophilic Coating, 4Cm Radiopaque Length , Proximal Optimisation Balloon Should Be With Ultrashort Balloon Shoulder 0.6Mm And Rbp 22Atm. Usfda/Ce/Dcgi Approved , High Pressure 0.75Mm Cto Balloon With Entry Profile 0.015. Usfda/Ce/Dcgi Approved , Ptca Coronary Scoringballoon Helical Shaped And Electropolished Scoring Elements With Rectangular Edges Large Working Range 2Atm To 20Atm. Usfda/Ce/Dcgi Approved , Semi Complainttrifold Bdc Rapid Exchange Port 25 Cm Form Digital Tip Nylon Material Hydrophillic Cotatingwith 2 Platinum/Iridrim Ro Marker 1.9F Stainsteel Ptfe Coated Hypo Tube. Usfda/Ce/Dcgi Approved , Non Complainttrifold Bdc Raped Exchange Past 25 Unform Digital Tip Nylon Material Hydrophilline _____ With 2 Platinum/Iridrim No Marker 1.9F Stainsteel Ptfe Coated Hypotube.Usfda/Ce/Dcgi Approved , Drug Coated Sirolimus Coated Ptca Balloon Catheter . 2 To 4.5 Mm Diameter Usfda/Ce/Dcgi Approved , Non- Compliant Ptca Balloon Dilatationcatheter With Dual Gold Marker Having Entry Profile Of 0.016 With Nominal Pressure 0F 10 Atm And Rbp Of Up To 22 Atm. Available In Different Sizes Usfda/Ce/Dcgi Approved , Semi- Compliant Ptca Balloon Dilatation Catheter With Dual Gold Marker Having Entry Profile Of 0.016 With Nominal Pressure 0F 6 Atm And Rbp Of Up To 14 Atm. Available In Different Sizes Usfda/Ce/Dcgi Approved , Ptca Non-Compliant Balloon With Rbp Of 20 Atm Having 3 Fold With Shape Memory Technology. Balloon Tip Should Be 2Mm, Tri-Layered Atraumatic With 0.41Mm Tapered Profile For Lesion Entry. Balloon Material Made Of Poly Amide For Better Control & Expansion With Minimal Growth. Available In All Lengths From 8Mm To 18Mm With Diameter Starting From 1.75Mm Onwards. Quote In Both Monorail Or Rapid Exchange. Dcgi Approved. , Nitinol Hydrophilic Guidewire Exchange Length 260Cm Ce/ Dcgi Approved , Slender Profile Cto Balloon With Unique Meter 1Mm To 6Mm Length. Ce/ Dcgi Approved , Lollipop Tip Ptca Balloon With Spherical Tip Ce/ Dcgi Approved , Triploblastic Ptca Balloon With Selectine Hydrophilic Coating Ce/ Dcgi Approved Tapered Tip Nc Balloon , Ptca Balloon (Semi-Compliant) – Ce Approved/Dcgi Approved 6F Kbt Compatible Ultra Low Tip Entry Profile • Guide Catheter – 5F Compatible • Balloon Material: Soft Multi-Layered Polyamide • Balloon Fold: Trifold • Hydrophilic Coating: Selective Hydrophilic Coating At Distal Shaft Including Balloon Tip • Length (Mm): 9,12,15,20,25,30 • Diameter(Mm): 2, 2.25, 2.50, 2.75, 3.00, 3.25, 3.5, 3.75, 4.00 & 4.5 • Nominal Pressure: 12Atm • Rated Burst Pressure (Rbp) – 16 Atm (14 Atm For 4.5 Mm) , Ptca Balloon (Non-Compliant) – Ce Approved Quote Both Monorail (Rapid Exchange) And Otw Balloons Available In All Sizes From Variable Lengths Should Have A Very High Rated Burst Pressure Length (Mm): 6,8,10,12,15,20,25,30 Diameter(Mm): 2, 2.25, 2.50, 2.75, 3.00, 3.25, 3.5, 3.75, 4.00, 4.5 & 5.0 Nominal Pressure: 12 Atm Rated Burst Pressure (Rbp) – 20 Atm ( 18 Atm For 5Mm) Diameter Growth Between Nominal And Rated Burst Pressure Less Than 6%. Two Platinum-Iridium Markers Shaft Length = 140Mm. , Ptca Semi-Compliant Balloon With Nyloflex&Navpro Technology With Excellent Wrap/Re-Warp & Kink Resistance For Smooth Transition In The Cto Lesion. Tip Entry Profile Of The Balloon Should Be =0.017” With High Rbp Of 16Atm. Balloon Diameter Starting From 1.00Mm Onwards With Smallest Length Of 5Mm Onwards. Quote In Both Monorail Or Rapid Exchange. Dcgi Approved. , Ptca Balloon Less Than 0.016 Tip Profile Low Profile Rapid Exchange Semi-Compliant Balloon With With Rbp Of At Least 14 Atm With 2.3 F Shaft. Dia 1.00Mm, 1.25Mm, 1.50Mm, 1.75Mm, 2.00Mm, 2.25Mm, 2.50Mm, 2.75Mm, 3.0Mm, 3.25Mm, 3.50Mm & 4.00 Mm And Lengths From 5Mm, 10Mm, 15Mm, 20Mm & 30Mm. , Non-Compliant Rapid Exchange Ptca Balloon, With Enhanced Push Ability, Trackability And Kink Resistance, Rbp 22 Atm, Average Burst Pressure Of 30 Atm; Tip Entry Profile = 0.016”. Diameters 2.00Mm, 2.25Mm, 2.5Mm, 2.75Mm, 3.0Mm, 3.25Mm, 3.5Mm, 3.75Mm, 4.0Mm, 4.5Mm & 5.0Mm-5.0 Mm, Lengths From 8Mm, 10Mm, 12Mm, 15Mm & 18Mm. , Semi Compliant Balloon Catheters With Hydrophilic Coating, Low Entry Profile Of 0.016 Having Size- 1.00 Mm To 4.00 Mm, Lengths 5 Mm To 40 Mm , Non Compliant Balloon Catheters With Hydrophilic Coating, Low Entry Profile Of 0.016 Having Size- 1.50 Mm To 5.00 Mm, Lengths 8 Mm To 40 Mm , Stainless Steel Hypotube , Polymer Cathater Segment 1:1 Wire Braiding, Hydrophilic Coated With Radical Coller, 0.57 Inner Diameter,& 0.067 Outer Diameter. Available Size 5 Fr. 5.5Fr, 6 Fr, 6Fr Longer,7 Fr , Balloon Material Optiq, Bisegment Inner Lumen Shaft Monorail Catheter, Proximal Shaft 2.7 Fr Distal Shaft 2.3Fr, Delivery System Working Length 1.42 Cm. , Sirolimus Cocr Des, Open And Closed Cell Design, Special Electro- Polishing Technique Along With Uniform 59?M Strut Thickness Across All Diameter 2.25 To 4 Mm, Length 8 To 48Mm , Bare Metal Covered Stent -Us Fda Approved , Stainless Steel Coronary Stents, Premounted On Balloon – Us Fda/Ce & Dcgi Approved Monorail (Rapid Exchange) And Over-The-Wire (Otw)Available In The Sizes And Lengths , Cobalt Chromium Coronary Stents, Premounted On Balloon – Us Fda/Ce & Dcgi Approved • Monorail (Rapid Exchange) And Over-The-Wire (Otw) • Available In The Sizes And Lengths , Covered Coronary Stents – Us Fda/Ce & Dcgi Approved • Monorail (Rapid Exchange) And Over-The-Wire (Otw)Both • Available In The Sizes And Lengths • Covered Graft Stent For Dissectedartery , Stainless Steel Renal Stents, Premounted On Balloon – Us Fda/Ce & Dcgi Approved • Monorail (Rapid Exchange) And Over-The-Wire (Otw) • Available In The Sizes And Lengths , Zotarolimus Eluting Stent - Us Fda/Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Chromium Cobalt Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda/Ce & Dcgi Approved , Abluminally Coated Sirolimus Eluting Thin Struts Microporus Stain Less Steel Stent With Bio Absorbable-Polymer Matrix, Where Balloon Is Also Coated With Sirolimusus Fda/Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromium With Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 48Mm With Biogradable Polymer.Us Fda/Ce & Dcgi Approved , Biolimus Eluting Stent - Us Fda/Ce & Dcgi Approved , Tacrolimus Eluting Stent - Us Fda/Ce & Dcgi Approved , Drug Eluting Biodegradable Polymer & Shellac Resign Top Coatus Fda/Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link Drug Eluting Stent -Us Fda/Ce & Dcgi Approved , Everolimus Eluting Chromium Cobalt Multi Link 48Mm Drug Eluting Stent -Us Fda/Ce & Dcgi Approved , Everolimus Eluting Coronary Stent System (Eecss) Includes: L-605 Cobalt Chromium (Cocr) Alloy Mounted On Thin, Single-Layer Balloon Enables High Pressure Deployment While Maintaining Flexibility And Strength. Pebax‡72D True Center Tips: Designed With Co-Axial Positioning System (Cps) Coating That Consists Of A Blend Of The Anti-Proliferative Drug Everolimus And Fluorinated Co-Polymers. Ultra-Low Crimped Stent Crossing Profile Of 0.039 Inch And Tip Entry Profile Of 0.017” (3.0X18mm). Post Dilatation Capabilities Up To 3.75 Mm For Diameters 2.0 – 3.25 Mm And 5.5Mm For Diameters 3.5 – 4.0Mm. Nominal Pressure 2.0 – 2.5 Mm Balloon Diameter: 9 Atm & 2.75 – 4.0 Mm Balloon Diameter: 12 Atm Rbp Of 16Atm Offers Exceptional Deliverability From The Re-Engineered Stent Delivery System Featuring A Single-Piece Outer Member For Added Pushability And Trackability. Safety Of Sent In High Bleeding Risk (Hbr) Patients Treated With 1-Month (As Short As 28 Days) Dual Antiplatelet Therapy (Dapt) , Everolimus Eluting Coronary Stent System (Eecss) Includes: L-605 Cobalt Chromium (Cocr) Alloy Mounted On Thin, Single-Layer Balloon Enables High Pressure Deployment While Maintaining Flexibility And Strength. Pebax‡72D True Center Tips: Designed With Co-Axial Positioning System (Cps) Coating That Consists Of A Blend Of The Anti-Proliferative Drug Everolimus And Fluroniated Co-Polymers. Ultra-Low Crimped Stent Crossing Profile Of 0.0425” And Tip Entry Profile Of 0.017” (3.0X18mm). Post Dilatation Capabilities 2.00Mm-2.50 Mm-3.25Mm 2.75Mm-3.25Mm- 3.75Mm 3.50Mm-4.00Mm-4.50Mm Nominal Pressure 2.0 – 4.0 Mm Balloon Diameter: 10 Atm Rbp Of 18 Atm Offers Exceptional Deliverability From The Re-Engineered Stent Delivery System Featuring A Single-Piece Outer Member For Added Pushability And Trackability. Safety Of Sent In High Bleeding Risk (Hbr) Patients Treated With 1-Month (As Short As 28 Days) Dual Antiplatelet Therapy (Dapt) , Everolimus Eluting Platinum Chromium Stent Bio Absorvbale Polymer Stent Us Fda/Ce & Dcgi Approved , Sirolimus Eluting Stent Cobalt Chromiumwith 2 Links & 8 Crownswith Diameter Of 2Mm To 4.5Mm With Length Of 8Mm To 38Mm With Biogradable Polymer And Gradient Coating.Us Fda/Ce & Dcgi Approved , Biodegradable Polymer/Microporous Surface/Sirolimus Drug & Shellac Resign/Abluminal Coating/Temperature Control Device-Tag Alertus Fda/Ce & Dcgi Approved , Dual Drug Polymer Free Stent/ Plat Form-Cobalt Cromium/Probucol Drug Instead Of Polymer/Microporous Surface/Abluminal Coating/Shellac Resin/Strut Thickness 79Micron , C.P. Stent Covered , C.P. Stent Uncovered , Drug Eluting Platinum Chromium Coronary Stents, Premounted On Balloon – Us Fda/Ce & Dcgi Approved Monorail (Rapid Exchange) And Over-The-Wire (Otw)Available In The Sizes And Lengths , Sirolimus Eluting Cobalt-Chromium Stent With Abluminal Gradient Coating - (L-605 Co-Cr Alloy) (Should Not Have Drug & Polymer Coating On Joints & Bends). 2 Links – 8 Crown Design •Bioresorbable Polymer Of Plcl (Poly Lactic Acid + Poly Capro Lactone Pcl) With Degradation Time Of 3-4 Months. Should Have Bioinspired Open Cell In Phase Design. •Low Concentration Of Sirolimus (0.8Ug/Mmsq). •Minimum Tip Entry Profile Of 0.42Mm •Pmda+Ce Approved , Polymer Free Evrolimus Eluting Stent Coronary Stent Withco-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016Usfda/Ce/Dcgi Approved , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length.Usfda/Ce/Dcgi Approved , Polymer Free Sirolimus Eluting Coronary Stent With Co-Cr Platform Having Microporous Surface, Abluminal Coating And Shellac Resin Withdiameters Of 2.0 Mm To 4.0 Mm Of Varying Length. Entry Profile 0.016 Usfda/Ce/Dcgi Approved , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withstrut Thickness 68?M (Sv), 79?M (Mv). Usfda/Ce/Dcgi Approved , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Stainless- Steel Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin With Temperature Control Device - Tag Alert Usfda/Ce/Dcgi Approved , Biodegradable Polymer Sirolimus Eluting Coronary Stentwith Co-Cr Platform Havingmicroporous Surface, Abluminal Coating And Shellac Resin Withs Strut Thickness 68?M (Sv), 79?M (Mv). Usfda/Ce/Dcgi Approved , New Generation Des Providing Synergywith Biodegradable Polymer With Microporous Surface. Sirolimus Drug And Cobalt Chromium Surface.Usfda/Ce/Dcgi Approved , Sirolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns With Cobalt Chromium. Usfda/Ce/Dcgi Approved , Everolimus Eluting Stent With Biodegradable Polymer. Distal 3 Mm Tip Should Be Hydrophilic Coated. Strut Thickness Should Be 60Microns Biodegrable Coating On Abluminal Side. Usfda/Ce/Dcgi Approved , Balloon Expandable Pulmonary Artery Stents – Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Available In Various Sizes , Ivc Stents Self Expendable - Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Available In Various Sizes , Sirolimus Coronary Stent System With Hybrid Open And Close Cell Design Ultra Low Strut Thickness 62.5 +/- 7.5 Micron With Control Dry Release 120 Days Dcgi Approved. , Everolimus Coronary Stent System With Hybrid Open And Close Cell Design Ultra Low Strut Thickness Control Dry Releaseusfda/Ce/Dcgi Approved , Bioresorbable Sirolimus Eluting 100U Strut Thickness Scafolddevice Usfda/Ce/Dcgi Approved , Thin Strut (50U) Everolimus Eluting Coronary Stent System Having Cobalt Chromium Platform. Usfda/Ce/Dcgi Approved , Sirolimus Eluting Cobalt Chromium Coronary Stent With Morphology Mediated Expension Technology. Diameter Of 2 To 4.5Mm Usfda/Ce/Dcgi Approved , Everolimus Drug Eluting Coronary Stent System On Cocr Platform With Biodegradable Polymer Based Available From 2.25M To 4.5Mm In Diameter Having Wavflo Open Strut Pattern Contributes To Large Angle During Expansion Eventually Leading To Better Stent Flexibility Along With & V2v (Valley-2-Valley) S Connectors For Enhancing Trackability &Crossability. Dcgi Approved. , Ultrathin Strut Everolimus Coated Drug Eluting Cobalt Chromium Coronary Stent With Hybrid Cell Non-Linear Line. Ce/ Dcgi Approved. , Sirolimus Coated Drug Stent Ce/Dcgi Approved Open Cell Design Only With Two Connectors Between The Rings Stent Material & Design: L-605 Co-Cr Alloy With Laser Cut Seamless Tubing In Serpentine Pattern. 60? Ultra-Thin Struts Across All Diameters And Lengths Crossing Profile Of = 0.97Mm Tip Entry Profile: 0.017” Ldz Link: Long Dual ‘Z’ Link Guiding Catheter: 5F Compatible Rbp: 16 Atm Length (Mm): 8 To 48 Mm Diameter (Mm) 2.25 To 4.00 Mm , Cobalt Ciiromium Renal Stents, Premounted On Balloon Dcgi Approved Monorail (Rapid Exchange) And Over-The-Wire (Otw) Available In The Sizes And Lengths Three Mid-Strut To Mid-Strut Connectors Between Two Rings. Two Different Crown Design For Diameters Between 5-7 Mm. Crossing Profile = 1.50Mm Zero Foreshortening Available In 5,6 And 7Mm Diameter With Length Of 12,15 And 18Mm. , Seventh Generation Ridaforolimus Eluting Coronary Stent Which Utilizes A Distincting Co-Cr Frameware With Struts Of Varying Widths And Integrates Radiopaque Markers Into Its Structure Radiopaque Enhanced Metal Tip For Navigating Complex Aromatics. Usfda/Ce/Dcgi Approved , Ridaforolimus Eluting Stent On Cobalt Chromium Plateform With Flex X2 Delivery System Tapered Spring Tip And Reinforced Hypotube With Electromeric Coating. Usfda/Ce/Dcgi Approved , Everolimus Coated Drug Eluting Cobalt Chromium Coronary Stent - Dcgi Approved•Everolimus Drug Eluting Stent •Open Cell Design Only With Two Connectors Between The Rings •Stent Material & Design: L-605 Co-Cr Alloy With Laser Cut Seamless Tubing In Serpentine Pattern. •60? Ultra-Thin Struts Across All Diameters And Lengths •Crossing Profile Of = 0.97Mm •Tip Entry Profile: 0.017” •Ldz Link: Long Dual ‘Z’ Link •Ifu Labeled Overexpansion Of The Highest Available Diameter Should Be = 5.50 Mm •Guiding Catheter: 5F Compatible •Rbp: 16 Atm •Length (Mm): 8 To 48 Mm •Diameter(Mm): 2.25 To 4.00 Mm , Sirolimus Eluting Cobalt Chromium With Abluminal In-Groove Design Stent& Biodegradable Polymer Strut Thickness (86-100) Microns , Sirolimus Eluting Cobalt Chromium With Abluminal In-Groove Design Stent& Pla-Pgla Dual Biodegradable & Biocompatible Polymer For Optimum Drug Delivery Strut Thickness 65 Microns Ce Approved , Distal Embolic Protection Device - Carotid /Svg • (One Size For All Carotids) • Eccentric Filter With Nitinol Loop For360 Degree Wall Apposition • Rx .014 6F Sheath Compatible • 190 Cm Extra Supportwire • Uniform Micro Pore Size Of 110 Micron Pore Size With 1Mm Pore Free Zone • Non-Thrombogenic Nylon Membrane With Hydrophilic Coating • Should Allow Optimal Filtration In Vessels 3– 5.5 Mm Size Usfda Approved , Balloon Expandable Stent - Renal • Should Be Low Profile, 6F Guide And 0.018 Wire Compatible, Monorail System • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Increased Support And Radial Strength At Proximal End For Ostial Lesion • Stent Should Be Premounted On Semi Compliant Balloon Catheter • Stent Dia 4-7Mm, Length 15 & 19, Cathter Length 90 & 150 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Balloon Expandable Stent - Large Diameter • Should Have High Consistent Radial Strength, High Flexibility, Enhanced Radiopacity • Should Have Architecture Which Offers Excellent Lumen Coverage And Conformability • Should Have Low Foreshortening, Low Recoil. • Stent Should Be Premounted On Non Compliant Balloon Catheter To Avoid Dogboning And Proper Scafolding • Should Have Dual Lumen Catheter Design For Faster Deflation • Stent Dia 5-10Mm, Length 27,37,57, Cathter Length 135 Cm. • Should Have Crimping Technology Which Ensures No Stent Slippage From Balloon , Self Expanding Stent For Carotid Artery Stenting • Self Expandingelgilloy Stent With Closed Cell Design • Monorail,0.014 Wire & 6F Sheath Compatible • Reconstrainable Braided Stent • Shaft Length 135Cm • Dia : 6-9 Mm , Peripheral Self Expandable Stent • Should Be Laser Cut Self Expandingnitinol Stent With Proximal And Distal Markers • Should Have Hybrid Cell Design Which Promotes A Balance Of Radial Strength And Flexibility • Stent Struts To Be Electropolished To Avoid Micro Fracture Through Micro Cracks On The Stent Struts • Should Have Controlled Release/Deployment Mechanism To Ensure Precise Placement And Low Foreshortening • Dia 6 - 14 Mm , Length -20,40,60 ,80 ,100 , 120 • Should Be 6F Sheath And 0.035 Wire Compatible Across Sent Size Matrix , Peripheral Self Expanding Drug Eluting Stent • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Months With Lowest Dose Density Of 0.167 ?G/Mm2 For Sfa And Ppa. • Triaxial Delivery System • Hybridcell Architecture With Open & Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia - 6 & 7 Mm • Length -40,60,80 , 100,120 Mm • Us Fda Approved • Laser Cut Nitinol Stentdedicatedly Designedfor Sfa & Popliteal • Trixial Delivery System ,Hybrid Cell Architecture, • 6F Sheath Compatibility • Dia5, 6,7 ,8 Mm ,Length -40,60,80,100,120Mm ,150 Mm • Easy Deployment With Thumbwheel & Pull Grip , Inflation Device To Have High Presure Range Upto 26 Atm To Have High Pressure Stopcock Preventing Leakage During High Pressure Inflation 20Cc Volume Holding , Balloons - Nc Workhorse (0.035 Wire) Should Be Non-Compliant/Semi Compliant. Rbp Of 20 - 24 Atm (3-8Mm Balloon), 14-18 Atm (9-12Mm Balloon), Should Have High Rated Burst Pressure With Cratch/Puncture Resistant Nybax Material Dual Lumen Shaft With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Lubricious Medi-Glide Coating On Balloon Material Should Have Good Re-Wrap And Low Tip Profile Should Be 5F (3-7Mm Balloon)/6F (8-10Mm Balloon)/7F (12Mm Balloon) Sheath And 0.035 Wire Compatible Should Have Min Lesion Entry Profile Of 0.040 (1.016Mm) Should Have Choice Of Long Balloon Lengths 20Mm To 200Mm , Carotid/Renal Angioplasty Balloon Rx 018 Carotid/Renal Balloon • 018 Guide Wire Compatible • 4F Sheath Compatible To 4 To 7 Mm Diameter With 20Mm Length • Usable Catheter Length 135Cm For All Sizes . • Usfda Approved , Paclitaxel Coated Drug Eluting Balloon For Btk Paclitaxel Coating Should Be 2Ug/ Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -2-4 Mm , Paclitaxel Coated Drug Eluting Balloon For Iliac & Sfa Paclitaxel Coating Should Be 2Ug/ Mm2 Should Have Citrus Ester Exipentwith Hydrophobic Coating For Mininising Drug Loss Must Be Compatible With 0.018 -Inch Wire Loading Tool Should Be Avialbale Must Be Compatible With 4 Fr Sheath Balloon Length Should Be 20Mm – 200Mm Dia -4-7 Mm , Balloons - 0.018/0.014 Wire Compatible Should Be 4F/5F Sheath And 0.018/0.014 Wire Compatible With Choice Of Otw/Monorail Delivery System Should Be Non-Compliant/Semi Compliant Should Have High Rated Burst Pressure With Scratch/Puncture Resistant Pebax Material Should Have Lowest Tip Entry Profile Of Not More Than 0.022 And Good 5 Fold Re-Wrap Design Should Have Bioslide Hydrophilic Coating On Balloon Material Should Have Large Working Range Should Have Excellent Coulum Support With Balloon Laser Bonded And Short Atraumatic Tapered Tip Should Have Full Length Tapered Core Wire For Enhancdpushability And Kink Resistance Should Have Balloon Lengths Starting From 20 Mm- 150 Mm And Balloon Diameter From 3Mm To 10Mm , Balloon - 0.014 Wire Compatible For Btk Procedure With An Ultra-Low Lesion Entry Profile (0.017”/0.43 Mm) And Best-In-Class Crossing Profile (0.030”/0.76 Mm) With Deflation Times Of Less Than 10 Seconds*** And Balloon Lengths Up To 220 Mm Balloon Dia From 1.5 Mm To 4Mm With 4 F Sheath Compatibility Across Sizes. Monorail/ Over The Wire. , Balloons - Large Diameter For Vessel Diameters Of 12Mm And Above Should Be Non-Compliant And Have Low Deflation Time Balloon Material Should Be Lubriciously Coated With Scratch/Puncture Resistant Balloon Material Min. Sheath Compatibility Of 7F. , Peripheral Cutting Balloon Should Have Choice Of Diameter Range From 5Mm To 8Mm Should Have Micro Surgical Blades (Atherotome) On Non Compliant Balloon Only Bigger Diameter Cutting Balloons (5 - 8Mm) With 2Cm Atherotome Should Be 0.018 Wire Compatible With Otw Delivery System Exposed Atherotome Height To Be Not More Than 0.005 , Occlusion Balloon Should Be Soft Compliant Balloon Material With Radiopaque Markers At Both Distal And Proximal End Of Balloon Should Be 14F/16F Sheath And 0.035/0.038 Wire Compatible With Balloon Diameter Of 20Mm, 27Mm, 33Mm And 40 Mm , Guidewires - 0.018/0.014 Should Have Glidex Hydrophilic Distal Coating For Negotiating Tortous Anatomy And Colateral Approach. Should Be Available In Both 0.018 And 0.014. Should Provide Excellent Support Like A 0.035 In A 0.018/0.014 Wire Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Amplatz Super Stiff Wires - 0.035, 0.038 Should Have Stiff Core, Super Stiff Wire Body, Atraumatic Tip With Gradual Distal Core Taper Should Have Ptfe/Teflon Coating For Reduced Friction During Catheter Tracking. Should Support Catheter Exchange Should Have Flat Coiled Outer Wire Construction For Larger Inner Core And Hence Greater Support , Hydrophilic Marker Wire - 0.035 Should Have Single Piece Core With Radiopaque Polyurethane Jacket And Glidex Coated Hydrophilic Coating 4 Distal Paltinum Magic Markers Spaced At 1Cm For Improved Visualization Single Piece Core Design To Have Better Steerability, Pushability And Torque Transmission , Cto Wire 0.0140.014 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm ,18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , Cto Wire 0.018 0.018 Weighted Tip Cto Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load-12Gm ,18 Gm , 25 Gm , 30 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.014 Peripheral Wire Stainless Steel Core Wire Hydrophilic & Hydrophobic Coating Tip Load-3Gm & 6 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm 0.014 Peripheral Wire Stainless Steel Core Wire Hydrophilic & Hydrophobic Coating Tip Load-3Gm & 6 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm 0.014 Peripheral Wire Stainless Steel Core Wire Hydrophilic & Hydrophobic Coating Tip Load-3Gm & 6 Gm Us Fda Approved Wire Lengths - 190 Cm & 300Cm , 0.018 Peripheral Wire 0.018 Guide Wire With Stainless Steel Core Hydrophilic & Hydrophobic Coating Tip Load- 7.6 Gm , 6.5 Gm Us Fda Approved Wire Lengths -150 Cm ,200 Cm & 300Cm , Backup Meir Wire - 0.035 • Should Have Extra Stiff Shaft To Support Aaa Device • Should Have Very Flexible And Soft Distal Tip To Avoid Aortic Perforation/Vessel Trauma • Should Have Radiopaque Tip For Excellent Visibility, Ptfe Coated Proximal Shaft For Frictionless Advancement • Sholud Have Choice Of J And C Tip Shape With 185Cm And 260/300Cm , Guide Catheters - 6F, 7F, 8F Choice Of 16 Tip Shapes Amongst Indusry Standard Shapes In 55Cm And 90Cm Should Have Excellent Backup Support And Shape Retention Tungsten Atraumatic, Radiopaque Soft Tip Should Have Round Double Wire Braided Construction For Better Torque, Large Inner Lumen With Soft Tapered Tip Ptfe Inner Liner (For Smooth Passage Of Devices) And Polyether-Ester Polymer Outer Coating (For Shape Retention) , Support Catheter Catheter For Crossing Chronic Total Occlusions In Peripheral Arteries- Fda/Ce Mark Approved Various Sizes , 0.014 , 0.018,0.035 , Micro Punture Set Accustick Ii Introducer ( 4F Coaxial Dilator /6F Sheath With Ro ) With Locking Stiffening Cannula Anddiagnosticneedle With Stylet 21G + 0.038 J -Tip And 0.018 Nitinol Wire , Detachable Coil 0.018 Interlock Detachable Platinum Fibered Coil For Peripheral Use ,0.018 Assorted Sizes .Dia 3Mm -14 Mm . Assorted Lengths , Detachable Coil 0.035 Interlock Detachable Platinum Fibered Coil For Peripheral Use ,0.035 Assorted Sizes Dia 3Mm- 20 Mm, Assorted Lengths , Pushablevortx 18 Coil Pushable 0.018 System Platinum Vortx Coils 3 To 6 Mm In Diameter Of Assorted Length , Pushable18 Coilpushable Platinum 0.018 System Coils,3-6 Mm Diameter Of Assorted Lenghts , Pushablevortx 35 Coil Pushable Platinum Vortx0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pushable35 Coil Pushable Platinum 0.035 System Coils Upto 3 To 9 Mm In Diameter Of Assorted Lenghts , Pva Particle , Polyvinyl Alcohol Particles 350-500 Microns , Pva Particle Polyvinyl Alcohol Particles 500-700 Microns , Pva Particle Polyvinyl Alcohol Particles 150-250 Microns , Drug Eluting Beads D C Bead - Loadable Hydrogel Microspheres That Are Biocompatible, Hydrophilic,Non-Resorbable, And Precisely Calibrated And Approved For Loading With Doxorubicin And Irinotecan, Available In Size Range Of 70Um - 700Um. , Torquable Pre Shaped Superselectivemicrocatheter Torquablemicrocatheter For Peripheral Embolization, Made Of Nitinolhypotube And Hydrophilictip. Id 0.021 With Different Shapes.(Bern, J, Swan & Strait) , Microcatheter For Peripheral Embolization Stainless Steel Braided Microcatheter With Hydrophilic Coating For Peripheral Coil Embolization. Id 0.021 Manually Shapeable Tip , Hi-Flow Microcatheter For Peripheral Embolization Fiber Braided High Flow Microcatheter Od 2.8Fr /Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure. Dmso & Alcohol Compatible , Torquablesuperselectivemicrocatheter With Guidewire Torquablemicrocathetermede Of Nitinolhypotube With Hydrophilic Shapable Tip. Id 0.021 With 0.014 Manually Shapable&Reshapable Tip Wire Guide For Superselective Peripheral Embolization , Hi-Flow Microcatheter For Peripheral Embolization With Guide Wire Fiber Braided High Flow Microcatheter Od 2.8Fr /Id 0.027 Permiting 710 Micron Pva Particle & 5520 Kpi Burst Pressure With Hydrophilic Shapable Tip. Id 0.021 With 0.016 High Torque Control Dimond Cut Nitinolhypotube, Shapable Tip Micro Wire. Dmso & Alcohol Compatible , Peripheral Imaging Ivus Catheter 0.018 Peripheral Imaging Catheter (Ivus ) With 30 Mhz Frequency To Image Large Peripheral Vessels , Pharmaco Mechanical Thrombolysisdevice/ Catheter Pharmaco Mechanical Thrombolysisdevice/ Catheterwith Active Infusion Ofthromblytic Agentand Aspiration Suctionin Same Catheter .Dia -4F ,6F , 8F , Power Pulse Kit Angiojet Ultra Power Pulse Kit , Brocken Brough Needle (Transeptal ) , L.A. Wire, Stylet, Ruler,Syringe, Streching Tube ( Balloon Kit ) , Baloon Size 20-30 Mm Innoue , Baloon Size 20-30 Mmaccura , Baloon Size 20-30 Mm Sym/ Equivalent , Mullen Sheath , Baloon Shaper , Septal Dilator , Exchange Length Terumo Wire , Tyshak Balloon (9-12) , Tyshak Balloon Compatible Extra Stiff Wire (021 & 025) , Valver Balloon , Balloon (Innoue) With Accessories (Brocken Brough Needle (Transeptal ), L.A. Wire, Stylet, Ruler,Syringe, Streching Tube ( Balloon Kit ), Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon (Accura With Accessories) (Brocken Brough Needle (Transeptal ), L.A. Wire, Stylet, Ruler,Syringe, Streching Tube ( Balloon Kit ), Mullen Sheath, Baloon Shaper, Septal Dilator, Exchange Length Terumo Wire ) , Balloon For Pulmonary Valve Dilation , (A) Asd Closure Devices With Delivery System – Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes (6 Mm – 40 Mm) , Asd Closure Devices Without Delivery System – Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes (6 Mm – 40 Mm) , Delivery Sheath For Asd Closure Device – Us Fda/Ce & Dcgi Approved Compatible With The Device Approved In Item No. 1,2 , (A) Left Atrial Appensage Closure Device Us Fda/Ce & Dcgi Approved , Sizing Balloon For Device Closure – Circular Shape Us Fda/Ce & Dcgi Approved , Sizing Balloon For Device Closure – Oval Shaped - Us Fda/Ce & Dcgi Approved , Sizing Plate For Device Closure -Us Fda/Ce & Dcgi Approved , Delivery Cable For Asd/Vsd/Pda Devices - Us Fda/Ce & Dcgi Approved , Retrievers For Asd/Vsd/Pda Devices - Us Fda/Ce & Dcgi Approved , Seath For Retrival Of Devices - Us Fda/Ce & Dcgi Approved , (A)Vsd Closure Devices With Delivery System – Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes (6 Mm – 40 Mm) , (A)Pda Closure Devices With Delivery System – Us Fda/Ce & Dcgi Approved • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes , Pda Closure Devices Without Delivery System – Us Fda/Ce & Dcgi Approved , Embolisation Coils (0.018 Inch) -Us Fda/Ce & Dcgi Approved Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils (0.035 Inch) -Us Fda/Ce & Dcgi Approved Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils (0.052 Inch) -Us Fda/Ce & Dcgi Approved Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Plugs And Foam , Introducer System For Laa Closure With The Double Angulation Of 45° & 30° Containing I) Delivery Sheath With Back Bleed Prevention Hemostatic Valve And Side Port, Ii) Dilator, Iii) Delivery Cable, Iv) Loader. 8/9/10Fr. , Multifunctional Occluder -For Occlusion Of Muscular Vsd, Perimembranous Vsd, Rsov, Apex Window & Av Fistula - Should Be Low Profile (4F-6F) -Should Come With Aelongatable Waist And Can Be Used In Retrograde And Antegrade Approach. , Self-Expandablenitinol Stent With Radial Force Fixation, E Ptfe Dual Membrane Coating For (Excellent Biocompatibility And Durability Andno Suture On The Main Body To Prevent Pin Hole Leakage). Spine – Connecting Bar – (Gives Axial Support , - Avoids Shortening). Size Od - 20Mm To 44Mm; Length - 80Mm, 100Mm, 120Mm, 140Mm 160Mm And 200Mm. Tapering - 4/6/8Mm , Pecifically Designed For Endovascular To Exclusion Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating. No Suture On The Main Body To Prevent Pin Hole Leakage. Od - 22Mm To 34Mm, Length - 120Mm Main Body , Iliac Stent Graft Endovascular Stent Graft Device For The Treatment Iliac Aneurysm Or Dissection. With Proximal Bare Spring Configuration. It Should Be An Extension To Aaa Graft System. Od - 10Mm To 18Mm Length - 60Mm To 120Mm , Peripheral Snare With Tungesten Loop Coated With Titanium Nitride (5Mm To 35Mm) Having A Nitinol Shaft With The Length Of 120Cm. Type - Goose Neck. , Coronary Snare Withtungsten Loop Coated With Titanium Nitride (4Mm & 7Mm) Having Nitinol Shaft With The Length Of 200Cm. Type - Goose Neck , Steerable Sheath With Deflectable Tip (90-180 Degree) Size Available Upto - 5/6/7/8/9/10/12/14Fr. In 80Cm 90Cm Length , Aui Stent Graft System Specifically Designed For Treatment Of Endovascular Abdominal Aortic Aneurysm. A Self-Expandable Nitinol Stent With Eptfe Dual Membrane Coating With Connecting Spine Bar For Flexibility & Offers Axial Supportpreventing Foreshortening Of Stent. , Intravascular Retriever – Snare (‘Amplatz Gooseneck’ Type) - Us Fda/Ce & Dcgi Approved Snare Kit Should Include • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Should Have 90 Degree Preformed Snare Loop • Variable Sizes Of Loop (5-35 Mm) , Sheaths For Intravascular Snares - Us Fda/Ce & Dcgi Approved • Should Be Compatible With Item No. 84 , Vertebral Catheter - Us Fda/Ce & Dcgi Approved • In Various Standard Lengths And Curves , Coeliac Axis Catheter - Us Fda/Ce & Dcgi Approved • In Various Standard Lengths And Curves/Cobra Catheter , Shepherd’S Hook Catheter- Us Fda/Ce & Dcgi Approved • In Various Standard Lengths And Curves , Microcatheter(Coiled Stainless Steel Construction) - Us Fda/Ce & Dcgi Approved • In Various Standard Lengths And Curves • 2-3.8 F Size • .010-.022 Inch Wire Compatible • With Radio-Opaque Marker At Tip , High Pressure Angioplasty Balloon For Peripheral Vascular Use – Us Fda/Ce & Dcgi Approved • Should Have Rated Burst Pressure = 14 Atmosphere • Should Have Hydrophilic Coating • Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , Peripheral Stent Balloon Expandable (Otw/Rx) – Us Fda/Ce & Dcgi Approved • Should Be 0.035” Compatible • Should Be Made Of Cobalt Chromium • Should Be Quoted Either In Open Cell Or Closed Cell Design • Should Be Available In Various Balloon Ods • Should Have Balloon/Stent Lengths Available • Should Have A Shaft Lengths Of 75-135 Cm , Self-Expanding Peripheral Stent – Us Fda/Ce & Dcgi Approved • Should Be 0.014/0.018” Compatible • Should Over The Wire • Should Be Made Of Nitinol • Should Have The Least Lesion Crossing Profile For All Stent Diameters • Should Be Available In Various Stent Diameters Of 6-10 Mm • Should Be Available In Various Stent Lengths > 60 Mm • Should Have A Shaft Lengths Of At Least 110 Cm , Ivc Filter – Us Fda/Ce & Dcgi Approved , Ivus Catheter Compatible With System In Cath Lab Of Pbm Hospital Bikaner (Boston Scientific) , Ffr Catheter Compatible With St. Jude System , Oct - Guide Catheter For Intracoronary Oct, 0.014 Guidewire And 6 F Guide Catheter Compatibility. Lubricous Hydrophilic Coating And Low Tip Entry Profile For Crossing Tight, Distal Lesions.2.7 F Crossing Profile And Supportive Proximal Shaft Provide Superb Deliverability To The Area Of Interest. Lens Marker Is Immediately Proximal To Imaging Lens And The Distance Of Lens Marker From Tip Should Be 23 Mm And Proximal Marker At 82 Mm From The Lens Marker.Threeradiopaque Marker . , Rota Burr (All Size) , Rota Wire , Rotapro Pre Connected Exchangable Burr Catheter (Rota Advancer And Burr)- Us Fda Approved (Compatible With Rotapro Machine). , Ivl Cathetar Usfda Approved , Iabp Cathetar And Accessories , Bib (Balloon In Balloon) Type Balloons For Coarctation Dilatation-Us Fda& Ce And Dcgi Approved • Monorail (Rapid Exchange) And Over-The-Wire (Otw) Balloons Available In The Sizes And Lengths , Z Med Type Balloon For Aortic Coactation – Us Fda/Ce And Dcgi Approved • 5 To 20 Cm Diameter In All Sizes Otw / Rapid Exchange, Compatible With 0.014”/0.035” And 0.038” Wire , (A) Impellahemodynamicsupportcatheter 2.5 (B) Impellahemodynamicsupportcatheter5 (C) Impellahemodynamicsupportcatheter Cp (D) Impellahemodynamicsupportcatheter Rp , Acist Ivus Catheter • With Dual Frequency 40/60 Mhz In Single Catheter • Single Catheter For Both Coronary And Peripheral • Lubricious Hydrophilic Coating Supports Faster Pullback Speed Up To 10Mm/Sec For Minimizing Ischemic Risk • With Novel Offset To Design, Variflex Imaging Window. , Savvy Sensor Guided Tavi Wire Single Wire Working As A Guide Wire, For Hemodynamic Measurement And For Rapid Lv Pacing , Optowire A Hybrid Nitinol/Stainless Steel Pressure Guided Wire Powered By Fidela • Patented Optical Pressure Sensor Mounted Proximal To 3 Cm Long Radioopaque • Measure Physiologic Indices Including • Ffr & Diastolic Pressure Radio (Dpr) • Wire With Diameter Of .014 And Length Of 180 Cm • Operating Pressure Of -30 To + 300 Mmhg , Transcatheter Aortic Valve System With Size Of 21.5 To 32Mm With Balloon Expandableintra Annular Having Bovine Pericardium Leaf Lets And Nikil Cobalt Frame With All Accessories For Valve Cheplaynent System (Navigator) Balloon Dilatation Catheter Crimper And Introducer Sheath. , Transcatheter Aortic Heart Valve System Of Size Of 23 To 34Mm With Self Expanding Supra Annular Porane Pericardial Leaflets With National Frame With All Required Accessories. , Self Expending Frame Supra Annular Valve Designed, Bovine Pericardial Valve, Anti Calcification Tissue Treatment, Extended Internal Sealing Skirt, Two Rows Of Radio Opaque Markers On The Frame, Wearying Radial Force Frame- Optional, Available In 3 Sizes 22, 26 & 30Mm Which Cover The Treatable Annular Diameter Range From 17 To 27 Mm, Post Dilation Limits Of Valve Frame Equal To Approved Annulusdiameter Limit, Cell Size Of More Than 15 Fr, Less Metal At Inflow Sectionce & Dcgi Approved , Trans Catheter Aortic Heart Valve System Of Size 23-34Mm With Self Expending Supra Annular, Porcina Pericardium Leaf Leds Nitinol Frame Valve With External Skert Comptable Delivery Catheter & Loading System , Hd Ivus Catheter – (Usfda Approved) Available With 60 Mhz, Hd Ivus Catheter, Mechanical/ Rotational Catheter (Compatible With Ivus Machine) , Tavi Guidewire – (Usfda/Ce Approved) Outer Diameter 0.035” (0.889Mm), Length 275Cm, Core Material Stainless Steel, Spring Coil Material Stainless Steel, Spring Coil Coating Lubrigreentm Ptfe, Curves Extra Small (16Cm X 3.2Cm X 2.9Cm), Small (16Cm X 4.2Cm X 4.2Cm), Large (18Cm X 5.0Cm X 4.9Cm) , Oas Kit – 6F Compatible Orbital Atherectomy Device With 1.25Mm Diamond Coated Crown Designed For Bidirectional Superficial Calcium Sanding And Modify Deep Calcium Through Pulsatile Forces To Facilitates Stent Delivery And Expansion In Severely Calcified Lesions With Durable Nitinol Guidewire With 0.12” Proximal And 0.14” Distal End Along With Viper Slide Lubricant. , One Touch Release Inflation Device For Quick Deflation With 25Ml Syringe Volume Japan Pmda Approved. , Coronary Intervascular Lithotripsy Vascular System Having Balloon Diametersup To 4 Mm With 5 &6 Frenchguide Catheter Compatibility. , Self Expandable Transcathater Aortic Valve Implantation (Tavi) With Dry Tissue Technology, Preloaded Delivery System, Available In Different Sizes. , Cathater Should Be Radio Opaque Marker And Tip, Compataible With 0.0035 Guidewire. The Catheter Should Have Cvd Proximal Lumen Port Distance From Tip 10Cm The Catheter Should Have Cvd Proximal Lumen Port Distance From Tip 10Cm. Should Have Additional Lubricity, Availabe In Various Configration & Come With Introducr &Cathater Straightner. , Self Expandable Transcathater Bicaval System With Dry Tissue Technology, Pre Loaded Delivery System, Available In Different Sizes , Vvirpacemaker Us Fda/Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories Mri Compatible , Vvirpacemaker Us Fda/Ce & Dcgi Approved Digital Multi-Programmable Pacemaker.Mode: Single Chamber: Vvir/Aair. With Beat To Beat Auto Capture And Proven Longevity Of >9.5 Years With 100% Pacing Of Ra/Rv @2.5Volts. Digital High Sampling Rate Of P/R Wave And Automated Ventricular Rate Stabilization During Af. With 6F Compatible Passive-Fixation Tined Lead Or Screw In Lead & Lead Introducer & Dual Rate Responsive Sensors. Mri Compatible , Vdd/Vddr Pacemaker Us Fda/Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessoriesmri Compatible , Dddr Pacemaker Us Fda/Ce & Dcgi Approved Permanent Pacemakers With All Leads And Accessories Mri Compatible , Ddd 1.5 Tessla Mri Compatable 6 Fr Lead Optium Coating Af Suppresion Algorithm Ventricular Intrinsic Preference Auto Capture Usfda Approved , Dddr Pacemaker Us Fda/Ce & Dcgi Approved Digital Multi-Programmable Pacemaker Mode: Dual Chamber: Dddr. With Features Of Automatic Threshold Check, Auto Adjusting Of Av Delay (Extendable Upto 400 Ms), And Automatic Intrinsic Activity Search. With Beat To Beat Auto Capture And Proven Longevity Of >10 Years With 100% Pacing Of Ra & Rv At 2.5 Volts. With 6F Compatible Passive-Fixation Tined Leads Or Screw In Leads & Lead Introducers & Dual Rate Responsive Sensors. Mri Compatible , Dddr 3 Tessla Mri Compatable 6 Fr Lead Optium Coating Af Suppresion Algorithm Ventricular Intrinsic Preference Optimization Of Av Delay Auto Captureusfda Approved , Dddr Pacemaker Us Fda/Ce & Dcgi Approved Permanent Pacemakers For Physiological Pacing (His Bundle And Left Bundle Pacing) With All Leads And Accessories. Mri Compatible , Dual-Chamber Pacemaker With A Compact 8 Cc Volume And Extended Battery Longevity Of Up To 12 Years. Fully Mricompatible With Auto Mri Mode For 1.5T And 3.0T Full-Body Scans. Integrated Sleep Apnea Monitoring Enables Continuous Detection Of Nocturnal Respiratory Disturbances. Features Advanced Atrial Fibrillation (Af) Management Algorithms, Including Support For Patients With Sinus Node Dysfunction, Ensuring Optimal Atrioventricular Synchrony And Reduced Ventricular Pacing , Dual-Chamber Pacemaker With Mri Compatibility (3.0T), Featuring Automatic Mri Mode Activation. Dual Sensor Technology (Accelerometer And Minute Ventilation) Includes Integrated Sleep Apnea Monitoring And Apnea Episode Detection & Advanced Arrhythmia Detection, Lead Integrity Monitoring, And Remote Follow-Up Capability. , Physiological Pacing Lead (His Bundle And Left Bundle Pacing) & All Accessories Us Fda/Ce & Dcgi Approved , Physiological Pacing Lead With Stylate Driven With Helix Locking Tool. , Aicd Single Chamber Pacemaker With All Leads Us Fda/Ce & Dcgi Approved, Icd With All Leads And All Accessories • Single Chamber • All Basic Programmable Parameters • Must Be Mr Conditional. • Must Have Facility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf/Distance Telemetry Programming • Rv Lead Must Be 9F Of Less In Size And Have Proven Performance Of 5 Years. • Lead Should Be Steroid Eluting And Df-1 & Df-4 Compatible • Battery Capacity More Than Or Equal To 1.8 Amp Hour Thickness Less Than 10Mm • Mri Compatible • , Aicd Single Chamber 3 Tessla Mri Compitable With Bluetooth Remote Monitoring St Segment Monitoring Rv Lead 7Fr Or Less Us Fdaapproved , Aicd Dual Chamber Pacemaker With All Leads Us Fda/Ce & Dcgi Approved, Icd With All Leads And All Accessories • Dual Chamber • All Basic Programmable Parameters • Must Be Mr Conditional • Must Have Acility Of Atp Befor Charging For Defibrillation • All Basic Programmable Parameters With Shock Reduction Technology Comprising Of Svt, T-Wave, Rv-Noise Discrimination Features. • Must Have Facility Of Rf/Distance Telemetry Programming • Rv Lead Most Be 9F Or Less In Size And Have Proven Performance Of 5 Years • Must Have Algorithm Of Automatic Conversion From Aair To Dddr And Vice Versa (For Minimize Ventricular Pacing) • Must Have Algorithm For Management Of Neuro Cardiogenic Syncope • Must Have Automatic Threshold Management For Patient Safety. • Mri Compatible , Aicd Dual Chamber 3 Tessla Mri Compitable With Bluetooth Remote Monitoring Feature Can Be On As Per Patient Demand Or Requirementrv Lead 7Fr Or Less 40 J Delivered Energy. Congestion Monitoring, St Segment Monitoring Us Fdaapproved , Biventricular Pacemaker With All Accessories And Leads Us Fda/Ce & Dcgi Approved, Biventricular Pacemaker With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay • Must Have Facility For Egm Based Optimization Of Av, Pv And Vv Delays • Must Have Quadripolar Lead For Lv Pacing • Must Have Fluid Monitoring System • Must Have Facility For Active Fixation Of Lv Lead In C S (Either Screwing Ordeployable Lobes With Anchor Mechanism) • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available • Mri Compatible , Combo Device (Crt-D)With Quadripolar Lv Lead And Df-1 Rv Lead Must Be 3T Full Body Mri Conditional Must Have Atleast 17 Pacing Vectors In Lv Lead Must Have Rate Responsive Feature With Mv Sensor Must Have Battery Capacity Of More Than 1.8 Ampere Hour Warranty Of Atleast 6(4+2) Years , Crt-D 3 T Mri Competable With Quadri Poalr Lead Bluetooth Remote Monitoring Feature Can Be As Per Patient Demand Or Requirement, Rv Lead 7 Fr Or Less, 40 J Delivered Energy Vfta Algorithm Congetion Monitoring, St Segment Monitoring Us Fda Approved , Biventricular Pacemaker + Icd With All Leads Us Fda/Ce & Dcgi Approved, Biventricular Pacemaker + Icd (Combo Device) With Atrial, Rv, Lv Leads And All Accessories Required During Imlantation • Must Have All Basic Programmable Parameters • Must Have Quadripolar Lead For Lv Pacing • Facility Of Atp During Charging For Defibrillation • Must Have Fluid Monitoring System • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • Must Have Algorithm For Af Suppression With Programmable Automatic Mode Switch Basal Rate. • Must Have Facility For Automatic Lv Only And B/V Pacing And Automatic Av, Vv Delay • The Size Of Atrial And Rv Lead Must Be Df-4 Compatible And Lv Lead Quadripolar • Must Have Mri Compatible • Company Must Quote Only The Latest Model Of Devices Commercially Available. • Mri Compatible , Remote Monitoring Device With International Roaming • Must Have Automatic Hands Free Transmission For Patients • Must Have Physician Friendly Colour Coded Urgency Settings • Must Be Compatible With Standard Internet Settings • Interrogation Capabilities Should Be Compatible With In Office Follow Up • Alert Notification Should Be Available As Text Messages On Mobile • Direct Presence Of Parent Company In India (Not Only Through The Distributors) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Crt-P 3T Mri Competable With Quadri Polar Lead Ra/Rv Lead 7 Fr Or Less Suppression Algorithm Congestion Monitoringus Fda Approved , Single Chamber Lead Less Pacemaker With Battery Longevity More Than 17 Years And Have Retrievable Facility , Dual Chamber Lead Less Pacemaker With Retrievable Facilityit Has All Mode Like Ddd, Dddr, Ai Us Fda Approved , Implantable Loop Recorder • Must Be Able To Detect Asytole, Brady-Arrhythmia And Vt/Fvt • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India (Not Only Through The Distributors) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Implantable Loop Recorder For Af Detection • Must Be Able To Detect Asystole, Brady-Arrhythmia And Vt/Fvt And At/Af • Must Have The Storage Capacity Of >45 Minutes • Must Have Dynamic Sensing Threshold For R Wave Sensing Along With Noise Reversion • Must Have A Patient Tool For Symptomatic Recording Along With Alerts • Must Be Able To Give Af Burden Reports To Monitor The Progress Of Chronic Af Patients • Must Have At Least 35 Months Of Longevity • Must Be Compatible With Remote Monitoring Device • Direct Presence Of Parent Company In India (Not Only Through The Distributors) And Company Must Provide Its Trained Technical Person For Each Implantation Whenever Required And For Follow Up Programming When It Is Required • Company Must Provide At Least One Programmer Exclusively To The Cardiology Dept • Company Must Quote Only The Latest Model Of Devices Commercially Available , Mobile Cardiac Telementry System For Arrhythmia Diagnosis • Must Have 7 Days Rhythm Monitoring With Active Life • Must Collect Ecgs Automatically For • Bradycardia And Tachycardia • Pause/Asystole • Atrial Fibrillation • Vt/Vf , Us Fda/Ce & Dcgi Approved, Biventricular Pacemaker + Icd (Combo Device)Without Lead , Us Fda/Ce & Dcgi Approved, Biventricular Pacemaker (Crt) Without Lead , Us Fda/Ce & Dcgi Approved, Aicd Dual Chamber Pacemaker Without Lead , Us Fda/Ce & Dcgi Approved, Aicd Single Chamber Pacemaker Without Lead , Us Fda/Ce & Dcgi Approved Dddr Permanent Pacemakers Without Lead , Us Fda/Ce & Dcgi Approved Vdd/Vddr Permanent Pacemakers Without Leads , Us Fda/Ce & Dcgi Approved Ddd Permanent Pacemakers Without Lead , Us Fda/Ce & Dcgi Approvedvvi Permanent Pacemakers Without Lead , Us Fda/Ce & Dcgi Approved Vvir Permanent Pacemakers Without Leads , Atrial Lead&All Accessories For Biventricular Pacemaker (Crt), Us Fda/Ce & Dcgi Approved , Rv Leadall &Accessories For Biventricular Pacemaker (Crt), Us Fda/Ce & Dcgi Approved , Lv Leadall &Accessories For Biventricular Pacemaker (Crt), Us Fda/Ce & Dcgi Approved , Atrial Leadfor Biventricular Pacemaker + Icd (Combo Device) With All Accessories Required During Imlantation Us Fda/Ce & Dcgi Approved , Rv Leadfor Biventricular Pacemaker + Icd (Combo Device) With All Accessories Required During Imlantation Us Fda/Ce & Dcgi Approved , Lv Leadfor Biventricular Pacemaker + Icd (Combo Device) With All Accessories Required During Imlantation Us Fda/Ce & Dcgi Approved , Rv Lead For Aicd Single Chamber, Us Fda/Ce & Dcgi Approved , Pacing Leads For Aicd Dual Chamber, Us Fda/Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddr Permanent Pacemakers Us Fda/Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddr Permanent Pacemakers Us Fda/Ce & Dcgi Approved , Atrial Leadpacing Lead For Dddpermanent Pacemakers Us Fda/Ce & Dcgi Approved , Ventricular Leadpacing Lead For Dddpermanent Pacemakers Us Fda/Ce & Dcgi Approved , Pacing Leads For Vdd/Vddr Pacemakers Us Fda/Ce & Dcgi Approved , Pacing Leads For Vvi/Vvir Pacemakersus Fda/Ce & Dcgi Approved , Epicardial Lead For Pacemakersus Fda/Ce & Dcgi Approved , Temporary Pacing Leads - Us Fda/Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Have 10 Cm Depth Markers To Enhance Placement. 3. Should Have Smooth, Polyurethane Hemocompatible Coating. 4. Should Have Clearly Marked Terminals. 5. Should Have Shrouded 2 Mm Pin Connector Leads. 6. Should Have Stainless Steel Centre Conductor And Stainless Steel Electrodes. 7. It Should Have Solid Core Enables User To Customize The Curve. 8. Should Have Optimal Torque Control For Challenging Anatomy , Temporary Pacing Leads: Balloon Floatable – Us Fda/Ce & Dcgi Approved 1. Should Be Us Fda & Dcgi Approved 2. Should Be Latex Balloon Tipped, Flow Guided For Stable Insertion. 3. Should Have 10 Cm Depth Markers To Enhance Placement. 4. Should Have Smooth, Polyurethane Hemocompatible Coating. 5. Should Have Clearly Marked Terminals. 6. Should Have Shrouded 2 Mm Pin Connector Leads. 7. Should Have Platinum Electrodes 8. It Should Have Flexible Tip Design For Delicate Placement. , Temporary Pacing Leads With Stylet - Us Fda/Ce & Dcgi Approved , Pulse Generator (Temporary) , Lead Extraction System Of Different Variety , Lead Locking Device Working Range Of 0.015, 0.023 Length 65 Cm , Dilatation Sheath Set For Lead Extraction10 Cm Long. , Mechanical Rotatingdilator Forlead Extraction Length47.5 Cm , 1 Port Cath-Lock™ Introducer Sheath With Hemostasis Valve And Sideport, Dilator, And 50Cm Double Distal Guidewire With J And Straight Ends , 2 Port Hemostasis Adapter With Sideports And Cath-Lock™ Sealing Mechanism, Venous Sheath, Dilator And 50Cm Double Distal Guidewire With J And Straight Ends , 3 Port Hemostasis Adapter With Sideports And Cath-Lock™ Sealing Mechanism, Venous Sheath, Dilator And 50Cm Double Distal Guidewire With J And Straight Ends , Intoducer Sheath With Hemostasis Valve And Sideport, And Dilator, Mullins Style Curve 6/7/8F Size, 61Cm Usable Length, 67Cm Dilator Usable Length , Swartz Intoducer Braided Sheath With Hemostatic Valve Sl0/Sl1/Sl2/Sl3 ( 8F, 63Cm Usable Length And 67Cm Dilator Usable Length) Accommodates Maximum 0.32 Guidewire , Swartz Intoducer Non Braided Sheath With Hemostatic Valve Sr0/Sr1/Sr2/Sr3 (8F,63Cm), (8F,63Cm Usable Length) Accommodates Maximum 0.38 Guidewire , 8.5F: 71Cm Bi-Directional (Assymetrical) Deflectable Sheath,Small, Medium And Large Curl Dimension 16.8Mm And 22.4Mm With Integrated Hemostasis Valve And Radiopaque Tip Marker And Various Curve Options, Compatible With98cm Transseptal Needle Along With 180 Cm Super Stiff Guidewire , 8.5F : 40Cm Bi-Directional (Assymetrical) Deflectable Sheath Use For Epicardial With Intergratedhemostasis Vale And Radipaque Tip Marker And Various Curve Options. , Brk/Brk-1 Needle-Adult,18 Gauge, Usable Length 71Cm. , Brk/Brk-1 Needle-Adult,18 Gauge, Usable Length 98Cm. , Fixed Curve Quadripolar Electrophysiology Catheter (6F/5F/4F, 1Mm Band Electrode) Crd/Jsn/Dao,2-5-2Mm Electrode Spacing. All Items Should Be Cpmpatible With Abbottclaris Ep System And Ensite 3Rd Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Fixed Curve Quadripolar Electrophysiology Catheter (6F) Crd-2,5Mm Electrode Spacing. All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3Rd Mapping System Istalled At Cath Lab, Pbmhospital (Haldiram Cardiology Center- Cardiac Dicision Of Pbm Hospital, Bikaner , Fixed Curve (Csl) Decapolar Catheter (6F) -35Cm Usable Length With 5-5-5- Spacing With Tip Electrode 2Mm Compatible With Claris And Ensite Mapping Machine. , Fixed Curve (Csl) Decapolar Catheter (6F) -120Cm Usable Length With 5-5-5- Spacing With Tip Electrode 2Mm All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3Rd Mapping System Installed At Cath Lab Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Deflectable Decapolar Electrophysiology Catheter With Connector (6F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Deflectable Decapolar Electrophysiology Catheter With Connector (5F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Deflectable Decapolar Electrophysiology Catheter With Connector (4F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Duo Decapolar Electrophysiology Catheter -20 Poles (7F) Usable Length 95Cm With 5-5-5 Spacomg,1Mm Band Electrode. All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Duo Decapolar Electrophysiology Catheter -20 Poles (7F) Push Pull Handle With 1-7-1 Spacing. All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , 8F Sensor Enabled Uni-Directional Circular Mapping Catheter With 3-3-3Mm & 5-5-5Mm Electrode Specification, 2Mm Tip & 1Mm Band Electrode With Fixed Loop. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , 8F Sensor Enabled Bi-Directional Circular Mapping Catheter Df Curve 3-3-3Mm & 5-5-5Mm Specification, 2Mm Tip & 1Mm Band Electrode With Fixed Loop. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , 8F Sensor Enabled Uni-Direction Circular Mapping Catheter With 6.5Mm Electrode Spacing Variable Loop With 15-25Mm Range. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , 8F Sensor Enabled Bi-Directionl Circular Mapping Catheter With 1-4-1 Mm Electrode Spacing Variable Loop With 15-25 Mm Range.All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , 8F Irrigated Bidirectional 16 Electrode, 2F Splines,3Mm Spacing, 1Mm Electrode Size,High Density Sensor Enable Mapping Catheter. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Bi-D-Deflectable Radio Frequency Ablation Catheter (7F, 4Mm Tip) 2-5-2 Electrode Spacing-With Universal Temperature Sensor (Thermocouple And Thermistor Temprerature Monitoring Capability) All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Uni-D- Deflectable Radio Frequency Ablation Catheter (7F, 4Mm Tip) 2-5-2 Electrode Spacing Usable Length 110Cm. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Uni-D- Deflectable Radio Frequency Ablation Catheter (5F, 4Mm Tip) 2-5-2 Electrode Spacing. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Irrigated Bi-Directional Ablation Catheter With Flexible Tip 1-4-1, Symmetric And Asymmetric Option. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Irrigated Uni-Directional Ablation Catheter With Flexible Tip 1-4-1 , D And F Curve. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Contact Force Sensor Enable Catheter With Fiber Optic Technology For Force Detection 3.5Mm Tip Electrode 8F, Six Saline Irrigation Hole, 2-2-2 Ring Spacing. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Intracardiac Echo Catheter-9F Size, Transducer Type 64 Element Phased Array, Viewing Sector 80 Degrees, Tip Deflection Anterior/Posterior,Left/Right+/- 120 Degree Flexion Compatible With Ice System , Magnetic & Impedance (Hybrid) Based Patches For Elctroanotomical Mapping For. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Magnetic Based Patches For Electroanotomical Mapping For Use With Ensite 3D Mapping System. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cool Point Tubing Set For Irrigated Rf Catheter With Dedicated Pressure Sensor And Compatible With Abbottcoolpoint Pump. , Cables For Fixed Quadripolar Electrophysiology Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For Fixed Decapolar Electrophysiology Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For Deflectable Decapolar Electrophysiology Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For High Density Mapping Electrophysiology Catheters Compatible With Ensite Mapping System , Cables For Ablation Range Of Electrophysiology Catheters Compatible To Use With Ibi T11& Ampere Rf .All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cable For Fixed Loop Circular Mapping Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cable For Variable Loop Circular Mapping Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner. , 2F Multipolar (> Ten Electrodes) For Mapping Through Coronary Vasculature , Basket Catheter With Accessory , Crista Catheter With Cable , Pacing Catheter With Angiogrophic Capability • Variable Sizes • Bipolar Or Quadripolar With Appropriate Cable • Cvp Monitoring & Angiographic Facility , Pediatric Use : All The Above Catheters, Sheaths Etc For Pediatric Use. • Implying Smaller French Size Like 4F, 5F, With Certification For Use In Children , Reusable Defibrillation/Transcutaneous Pacing Patches (Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6) , Disposable Defibrillation / Transcutaneous Pacing Patches (Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6) , Defibrillation/Transcutaneous Pacing Patches For Use In Infants And Children , Cryo Catheters (And Accessories)For Ablation Of Arrhythmias In Children And Adults , Disposable Electrocautery Patches For Rfa , Reusable Electrocautery Patches For Rfa , Deflectable Quadripolar Electrophysiology Catheter With Connector (6F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Deflectable Quadripolar Electrophysiology Catheter With Connector (5F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Deflectable Quadripolar Electrophysiology Catheter With Connector (4F)-110Cm Usable Length With 2-5-2 Spacing.All Items Should Be Compatible With Abbottclaris Ep System And Ensite 3D Mapping System Installed At Cath Lab, Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For Deflectable Quadripolar Electrophysiology Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For Fixeddecapolar Electrophysiology Catheters. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Cables For Ablation Sensor Enabled Range Of Electrophysiology Ablation Catheters Compatible To Use With Ibi T11& Ampere Rf.All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Contact Force Bidirectional Sensor Enable Catheter With Fiber Optic Technology For Force Detection 3.5Mm Tip Electrode 8F, Six Saline Irrigation Hole, 2-2-2 Ring Spacing, Tension Locking And Ergonomic Handle Design. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner , Egm Cables For Ablation Range Of Electrophysiology Catheters Compatible To Use With Ibi T11 & Ampere Rf Electrophysiology Ablation Catheters Compatible To Use With Ibi T11& Ampere Rf. All Items Should Be Compatible With Abbott Claris Ep System And Ensite 3D Mapping System Installed At Cathlab,Pbm Hospital (Haldiram Cardiology Center-Cardiac Dicision Of Pbm Hospital Bikaner