Tender For Repair Maintenance Of Various Types Of Summer Appliances And Other Connected Items At Af Stn Jammu And Kaluchak Under Ge Af Jammu; 1.00 REPAIR TO SPLIT AC AND WINDOW AC 2.00 Supply of Labour only for attending and rectification of daily complaints for day to day maintenance and servicing for Split AC/Window AC /hot & cold air conditioner/Dual inverter Air conditioners of any capacity and make installed in various locations of 23 wing AF Jammu and 256 SU Kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by Engineer In Charge.Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending day to day complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quoted shall be inclusive of transport from AF Station to work shop & back shifting within permises.( c) Any parts shall be replaced and paid separately as supply only against relevant item (s) of this schedule. 3.00 M&L for Shifting of Split type AC/ Window type AC capacity upto 2 Ton , including submain/point wiring all electrical items and drilling, making good on surface of PCC concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 Wing area and 256 SU Kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge. 4.00 Supply only the following Items to incorporate against repairable summer appliances Window / Split Type ACs against relevant items No 2.00 and 3.00 here-in- before: - 4.01 Blower motor complete suitable for window type AC upto 2.0 Ton. all as specified and directed by Engr-in-Charge. 4.02 Indicator suitable for window type AC up to 2 Ton. 4.03 Thermostat switch suitable for window type AC up to 2 Ton. 4.04 Control knob suitable for thermostat switch and selector switch of window type AC up to 2 Ton. 4.05 Selector switch suitable for window type AC up to 2 Ton. 4.06 Relay along with box suitable for window Type AC upto 2 Ton. 4.07 Plastic air filter suitable for window AC upto 2 TR. 4.08 Outer unit Condenser fan motor suitable for window type AC up to 2 Ton. 4.09 Fan for outer unit condenser motor suitable for window type AC up to 2 Ton. 4.10 Front grill as per existing suitable for Window type AC upto 2 Ton. 4.11 Plastic air filter suitable for Split AC Indoor unit AC upto 2 TR. . 4.12 S&F Power control Board ( PCB ) for window type /Split type AC up to 2 Ton . 4.13 S&F Power control Board ( PCB ) for split AC indoor unit dual inverter/Hot and cold AC up to 2 Ton . 4.14 S&F Power control Board ( PCB ) for split AC out door unit dual inverter/Hot and cold AC up to 2 Ton . 4.15 Wiring kit suitable for split AC and window Type AC upto 2 Ton. 4.16 Condenser fan motor complete with fan suitable for out door unit of split Type Air conditioner upto 2 Ton. 4.17 Fan for condenser motor suitable for split Type Air conditioner out door unit. 4.18 Relay/Contractor suitable for Split Type AC upto 2 Ton. 4.19 Cooling coil evaporator fan motor complete suitable for indoor unit of split Type Air conditioner upto 2 Ton. 4.20 Blower for indoor unit of Split AC upto 2 Ton AC. . 4.21 Foaming insulator for AC suction/ cooling line,7/8 ( Approx - length 5.9 ft). 4.22 S&F of condenser outdoor unit capacity 2TR/1.5TR of split AC and also removing old u/s condenser complete all as specified and directed by Engineer-in-charge. 5.00 S&F as in replacement ( hermetically ) sealed compressor unit rotatry type for window Type Air conditioner for the following capacity including gas charging: - 5.01 Capacity 2 TR. 5.02 Capacity 1.5 TR. 6.00 Suppy and fixing suction and dischagre valve suitable for split Type Air conditioner out door unit as per sample. 7.00 S&F as in replacement ( hermetically ) uncut sealed compressor unit rotatry type for Split Type Air conditioner for the following capacity including gas charging: - 7.01 Capacity 2 TR. 7.02 Capacity 1.5 TR. 8.00 M&L for System fusing, welding, soldering, vaccumising and gas charging to Split Type air Conditioners for the following capacity: -Note-Gas charging at one location will be counted and paid as one job inspite of charging it number of times at same location. 8.01 Capacity 2 TR. 8.02 Capacity 1.5 TR. 9.00 S&F as in replacement (hermetically) uncut sealed compressor unit reciprocating type for window Type Air conditioner for the following capacity including gas charging: - 9.01 Capacity 2 TR. 9.02 Capacity 1.5 TR. 10.00 M&L for System fusing, welding, soldering, vaccumising and gas charging to Window Type air Conditioners for the following capacity: -Note-Gas charging at one location will be counted and paid as one job inspite of charging it number of times at same location. 10.01 Capacity 2 TR. 10.02 Capacity 1.5 TR. 11.00 Repair to Power control Board (PCB) of inverter type/hot and cold Split type AC/Window AC for the following capacity: - 11.01 Capacity 2 TR. 11.02 Capacity 1.5 TR. 12.00 S&F as in Replacement Ply Board 6 MM thick, grade BWR, Type BB, fixed with nails to timber frame work as in cover for window where Desert cooler / Window Type AC/Split type AC are installed complete all as specified and as directed. 13.00 S & F By Flushing to walls MCB distribution board double door 240 volts 2 way making good to disturbed surfaces of floors walls incl taking down the old DBs etc. 14.00 S&F MCB SPN upto 32 Amps, 240 Volts complete incl taking down old unserviceable . 15.00 M & L for industrial type metal socket enclosure with 240 volt MCB 20 Amps, with metal plug top complete all as specified incl taking down old unserviceable one. 16.00 S&F PVC insulated sheathed service wire twin core 10 Sqmm aluminium solid conductor 1100 volts grade incl taking down old unserviceable one. 17.00 S&F copper pipe 5/8 and removing old u/s copper pipe complete all as specified and directed by Engineer-in-charge. 18.00 S&F copper pipe 1/4 and removing old u/s copper pipe complete all as specified and directed by Engineer-in-charge. 19.00 REPAIR TO DESERT COOLER 20.00 Labour for day to day maintenance and servicing for Desert Cooler for 23 wing AF Jammu and 256 SU Kaluchak (excluding sundays and holidays) with skilled mechanic and helper including detecting fault of Desert cooler complain and servicing all unserviceable parts for desert cooler and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition , all as specified and direted by Engineer In Charge.Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending day to day complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quoted shall be inclusive of transport from AF Station to work shop & back shifting within permises.( c) Any parts required to be replaced shall be replaced and paid separately as supply only against relevant item (s) of this schedule. 21.00 Shifting of Desert Cooler including submain/point wiring all electrical items and drilling , making good on surface of PCC concreting, white cement plastering and iron frame /angle all necessary items and transporting complete from one location to other location in 23 Wing area and 256 SU Kaluchak area and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge 22.00 Supply only the following items ( PROVISIONAL) to incorporate against items here-in-before. 22.01 Grass wool pads (set of three). 22.02 Switch piano single pole one way 6 Amps. 22.03 Indicator lamp 6 Amps. 22.04 Selector switch for speed controller of motor ( three steps). 22.05 Submersible tulu Pump single Phase 230 Volt. 22.06 Front grill for desert cooler. 22.07 Desert cooler fan motor with fan complete. 23.00 Supply only the following capacitors to incorporate against repairable summer appliances Window / Split Type ACs , Desert cooler, Water cooler: - 23.01 Running capacitor 45 MFD. 23.02 Running capacitor 50 MFD. 23.03 Running capacitor 4 MFD. 23.04 Running capacitor 6 MFD. . 23.05 Running capacitor 10 /15 MFD. 23.06 Starting capacitor 100 / 120 MFD capacity . 24.00 S&F plug and socket for single phase application complete with plug and socket in sheet metal enclosure including MCB SP 20 Amps complete fixed in repairs all as directed. 25.00 S&F MCB single pole and neutral of 10 KA breaking capacity 32 Amps fixed in repairs complete all as specified and as directed. 26.00 M&L for sub main wiring with two run of 6.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than 1.2 mm thick and of 25 mm dia & 6.00 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.(Note : Two runs of copper cable, one run of earth wire, one run of PVC conduit shall be measured as one unit.) 27.00 M&L for sub main wiring with two run of 4.00 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including including PVC cassing capping with fitting and accessories & 4.00 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.(Note : Two runs of copper cable, one run of earth wire, one run of PVC casing caping shall be measured as one unit.) 28.00 S&F Switch socket combination two in one multipurpose suitable for 3 pin 5 amp and 16 amp flush type universal, fixed in repairs, complete all as specified. 29.00 S&F Plug top 15 Amps capacity, fixed in repairs complete all as specified and as directed. 30.00 S&F Plug top 5 Amps capacity fixed in repairs complete all as specified and as directed. 31.00 REPAIR TO VOLTAGE STABILIZER 32.00 M & L for day to day maintenance and servicing for Voltage Stabilizer for 23 wing AF Jammu and 256 SU Kaluchak with high skilled refrigerator mechanic and helper including detecting fault of Voltage Stabilizer complain and servicing all unserviceable parts for voltage stabilizer and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition, all as specified and direted by Engineer In ChargeNote: (a) Contractor has to employ highly skilled Refrigeration Mechanic with helpers and necessary T&P for attending day to day complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quated shall be inclusive of transport from AF Station to work shop & back shifting within permises. ( c) Any parts required to be replaced shall be replaced and paid separately as supply only against relevant item (s) of this schedule. 33.00 Supply only the following items ( PROVISIONAL) to incorporate against items here-in-before. 33.01 Trigger Transformer (Control Step- down- transformer) 12-0-12 Volts for 03 KVA to 06 KVA. 33.02 Power Relay 24 Volts / 250 Ohms 30 Amps ( 03- Nos) for 03 KVA to 06 KVA. 33.03 Bakelite Terminal strip 4 Way up to 40 Amps for 03 KVA to 06 KVA. 33.04 IC control cord for timer suitable for 03 KVA to 06 KVA. 34.00 Rewinding transformer of voltage stabalizer of capacity 03 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed. 35.00 Rewinding transformer of voltage stabalizer of capacity 05 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed. 36.00 S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. 37.00 S&F rolled mild steel Joist, channel, angle or tee sections ( Gde Fe 290 ) as in framing for stand for voltage stabilizer/ window AC/Desert cooler or for any other purpose with riveted bolted or welded attachment etc and inclusive of one primer coat , one under coat and one finishing coat of synthetic enamel paint, including taking down of old broken steel complete all as specified and as directed. 38.00 REPAIR TO REFRIGERATORS 39.00 Supply only the following Items to incorporate against repairable summer appliances refrigerator: - 39.01 Auto defrost thermostat switch for refrigerator of capacity upto 310 Ltrs. 39.02 Open type relay for refrigerator of capacity upto 310 Ltrs. 39.03 Over load protector for refrigerator of capacity upto 310 Ltrs. 39.04 Bulb screw type/ pin type for refrigerator of capacity upto 310 Ltrs. 40.00 M&L for System fusing, welding, soldering, vaccumising and gas charging to refrigerator of following capacities: -Note-Refrigerant gas for charging of equipment compressor shall be provided by the firm and cost thereof shall deemed to be included in the unit rate quoted against this Item. 40.01 Capacity 170 Ltrs. 40.02 Capacity 285 to 310 Ltrs. 41.00 S&F as in replacement hermetically sealed compressor unit for refrigerator: - 41.01 Capacity 170 Ltrs. 41.02 Capacity 280/310 Ltrs. 42.00 REPAIR TO DEEP FREEZERS 43.00 S&F the following Items to incorporate against repairable summer appliances deep freezers here-in- before: - 43.01 Thermostat switch suitable for Deep freezer of capacity up to 500 Ltrs. 43.02 Open type relay for Deep freezer of capacity upto 500 Ltrs. 43.03 Over load protector for Deep freezer of capacity upto 500 Ltrs. 44.00 M&L for System fusing, welding, soldering, vaccumising and gas charging to Deep freezer of capacity upto 500 Ltrs complete all as directed. 45.00 S&F as in replacement (hermetically) uncut sealed compressor unit for Deep freezer of capacity upto 500 Ltrs. 46.00 REPAIR TO WATER COOLERS Capacity 40/80 Ltrs & 60/120 Ltrs 47.00 Supply only the following Items to incorporate against repairable summer appliances Water cooler Here-in- before: - 47.01 Relay box type suitable for water cooler capacity 40-80 Ltr and 60-120 Ltr. 47.02 Relay open type suitable for water cooler capacity 60-120 Ltr 47.03 Relay open type suitable for water cooler capacity 40-80 Ltr. 47.04 Over load protector suitable for water cooler capacity 40-80 Ltr and 60-120 Ltr. 47.05 Condenser fan motor single phase 230 Volt complete with fan suitable for water cooler 40 to120Ltr. 47.06 Automatic thermostat switch suitable for water cooler 40/80 Ltr and 60-120 Ltr. 48.00 S&F as in replacement ( hermetically ) uncut sealed compressor unit for water cooler including gas charging 48.01 Capacity 40 / 80 Ltrs. 48.02 Capacity 60 / 120 Ltrs. 49.00 M&L for System fusing, welding, soldering, vaccumising and gas charging to appliances water cooler of following capacity: - 49.01 Capacity 40 / 80 Ltr. 49.02 capacity 60/120 Ltr. 50.00 S&F as in replacement Plato Brass push type bib cock chromium plated fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, complete all as specified and as directed by Engineer-in-charge. 51.00 S&F in replacement PVC connections 15 mm size with PTMT nuts of length 600 mm and washers, complete all as specified and as directed by Engr-in-Charge. 52.00 Brass stop cock, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge 53.00 S&F as in replacement PVC drain water hose pipe for water cooler of suitable length as directed complete with fixing clamps and elbows/ nipple etc. 54.00 Repair to rusted worn out body of water cooler comprising cutting, taking out of rusted MS Sheet from body and providing new MS Sheeet of 1.6 mm thickness including necessary cutting, bending, welding and fixing with screws including testing for leakage by filling water for 24 hours complete along with complete descaling of condenser unit with acid and making it neat and clean as all specified and as directed by Engineer-in-charge. 56.00 S&F wall mounted stand for mounting of outer unit of split ac made of heavy duty GI Steel of size upto 2.0 Ton with angle height 450 mm and bracket length 485 mm complete all as specified and directed. 57.00 S&F 5 metre transparent drain pipe for split ac and window ac leak resistant all as specified and directed. 58.00 Complete servicing of Blue Star floor standing (Tower Type ) AC 3 TR,air cooled outer unit and indoor tower all as specified and directed by Engineer-in-charge. 59.00 S&F scroll rotary compressor of capacity 3.0TR for outer unit of tower ac. 60.00 S&F Outer unit condenser fan motor for Tower ac of capacity 3 TR all as specified and directed. 81.00 . SCHEDULE A PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch A Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.