| 1 | Demolition of cement oncrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). Complete all as specified and directed. |
| 2 | M&L 75 mm thick, PCC 1:3:6, type C-2 using 20mm graded stone agg finished even and smooth without using extra cement as in plinth protection complete all as specified and directed. |
| 3 | Demolition of brick masonry built in cemeny mortar incl quoins arches pillars etc.complete all as specified and directed. |
| 4 | M&L for old size brick work with Sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortor 1:4 complete all as specified and directed. |
| 5 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 6 | M&L 10 mm thick cement plaster in CM 1:4 on external surfaces of fair faces of brick work or concrete surfaces mixed with recron fibre, finished surfaces even and smooth with out using extra cementcomplete all as specified and directed. (Note: recron fibre will be measured and paid separately) |
| 7 | M&L for Pre-cast cement concrete type B1 1:2:4 (20mm graded stone aggregate) block masonry with solid blocks, exc. 10 cm in width and setting in mortar, fixed as louvers for height upto 15m from FFL Complete all as specified and directed. |
| 8 | M & L forreinforcement TMT bars 10mm over dia including all cuttingbending binding cranking placing & binding withMS wire (annealed) not less than 0.90mm dia complete all as specified and directed. |
| 9 | M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 10 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides, nut bolts etc) and hanging; also fastening and fixing conforming to FE 410 grade quality B complete all as specified and directed. |
| 11 | M & L for preparation ofOld/New surfaces of wall by washing rubbing downand and applying two coat of cement based paintetc complete all as per specified and directed. |
| 12 | M&L for preparation of old/New surfaces of wallsincludingcornices, pillasters, etcand applying one coatof whitewash on wall complete allas specified and directed. |
| 13 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 14 | M&L Pre- painted galvalume aluminum zinc coating GI based Plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. complete all as specified and directed. |
| 15 | S&F mild steel work as wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed , drilling holes, notching for wires etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting , etc and similar work confirming to FE-290 Gde-E-165 complete all as specified and directed. |
| 16 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe-410- W(Gde- E-250) quality- B complete all as specified and directed. |
| 17 | S&F for Ball bearing for rolling shutters of both side complete all as specified and directed. |
| 18 | S& F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-250 Quality A) complete all as specified and directed. |
| 19 | Dismantling wrought iron or mild steel work of any description not otherwise provided for Complete all as specified and directed. |
| 20 | Dismantling Asbestos cement / CGI PGI (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 21 | M&L for preparation of newsurfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. Complete all as specified and directed. |
| 22 | M&L cement concrete type B1 (1:2:4) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, Cajja, kneelers, apex stones, pier caps, columns, hold fast, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weathering’s, throttling etc. and setting in CM (1:4) with joints to match complete all as specified and directed. |
| 23 | M&L for Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) 100mm thick as in floors complete all as specified and directed. |
| 24 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting outin soft / loose soil complete all as specified and directed. |
| 25 | Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out any type of soil complete all as specified and directed. |
| 26 | M&L for cement concrete type D2 1:4:8 (Using 40mm graded stone aggregate) 100mm thick as in sub base complete all as specified and directed. |
| 27 | M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 28 | M&L for Cement concrete work in pavement/hardstanding of flexural strength 40kg/per square centimeter in field using 400kg of cement per cubic metre, thickness of concrete 25cm or less complete all as specified and directed. |
| 29 | M&L for Granolithic concrete 1:1:2 floor topping 30mm thick; laid over cement concrete sub floors etc. and finished to an even and fair surface complete all as specified and directed. |
| 30 | M&L for Wearproof topping 20mm as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and directed.NOTE - Metallic floor hardener shall be measured and paid saperatly. |
| 31 | Supply only Metallic floor hardener complete all as specified and directed. |
| 32 | M&L for Brick work with sub class \"B\" bircks straight or curved on plan exc 6mtr mean radius in CM 1:6 complete all as specified and directed. |
| 33 | M&L for Fly ash brick birck work with well burnt, old size sub class \"B\" bricks of compressive strength not less than 35 Kg/sqcm, straight or curved on plan exc 6 metre mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 34 | M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces inCM in 1:6 finished even and fair without using etra cement.complete all as specified and directed. |
| 35 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 36 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 37 | M&L for two coats of synthetic enamel paint on new steel surfaces over one coat of red oxide primerover 10cm width of grith including preparation of surfaces complete all as specified and directed. |
| 38 | M & L for 75mm thick PCC type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection finished even and fair incl expansion joint at every 3mtr interval and every corner complete all as specified and directed. |
| 39 | S & F for Mild steel, plain, black sheet 1.6mm in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 40 | S & F for Welded steel wire fabric exc 4kg/sqm fixed complete to wood or steel members complete all as specified and directed. |
| 41 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to factory store and makinggood disturbed surfaces of walls, floors, etc. Complete all as specified and directed. |
| 42 | M&L for point wiring with 1.5 Sq mm, FRLS, PVC insulated, single core, unsheathed, multi stranded 1100 volts grade, copper conductor cable drawn through existing concealed conduiton ceiling/wall, with and includingcontinuous 1.5 Sqmm, FRLS, PVC insulated single core multi stranded copper conductor cable earth continuity conductor connected to common earth and earth dolly and including metal sheet enclosure rectangular terminal boxes of suitable size and white cover plates suitable for mounting modular switches, sockets etc Complete all as specified and directed. |
| 43 | (a) One light point/fan point controlled by one switch. Complete all as specified and directed. |
| 44 | (b) One switch socketout let 5 Amps on independent board. Complete all as specified and directed. |
| 45 | (d) One socket out let 5 Amps on the same board with other switches. Complete all as specified and directed. |
| 46 | ~Diitto~ all as per item No 46 above but with 2.5 sqmm PVC insulated multi stranded copper conductor and 2.5 sqmm PVC insulated multi stranded copper conductor as earth continuity conductor for one socket outlet 15 Amps on independent board. Complete all as specified and directed. |
| 47 | Supply & FixingModular type Switch single pole 16 Amps one way complete all as specified and directed. |
| 48 | Supply & Fixing Modular type socket out let 2 in 1, 6/16 Amps. complete all as specified and directed. |
| 49 | Supply & Fixing Modular type Socket out let 6 Amps. complete all as specified and directed. |
| 50 | Supply & FixingModular type Switch single pole 6 Amps one way complete all as specified and directed. |
| 51 | Supply and Fixing Ceiling Rose Surface PVC type 65 x 50 mm two to three terminals complete all as specified and directed. |
| 52 | Supply & fix LED High bay LIGHT 80 Watt, efficacy 150 lm/watt with PC difuser equipped with 4 Kv inbuilt surge protection, IP-65 complete all as specified and directed. |
| 53 | Supply and fixing in repair Security lighting luminaire for use with LED lamps, of capacity not less than 35/36 Watts IP-65, 230 Volts, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-65 class of protection, complete with control gear and all accessories fixed with 25/40 mm bore medium grade GI Pipe Bracket 1.5 mtr long bent to shape,fixed on wall with MS Flat Clamps, nuts & Bolts as required Complete all as specified and directed. |
| 54 | Supply and fix in replacement Smart bright Batten Series, LED luminaire using LEDs 22 watt, natural white, 2200 Lumen, with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start ,with 3 core flexiblecopper wire 1.5 sqmm and connecting accessories ,Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification Make : Philips /Bajaj/Crompton |
| 55 | Taking down Old un serviceable DB/Switch fuses complete with all accessories, any type/capacity complete, after disconecting cable connection, and remove to factory store. Complete all as specified and directed. |
| 56 | Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8 way, SPN, double door type, 240 Volt with 200 amps rated busbar. Complete all as specified and directed..(Note : MCBs will be Measured separately) |
| 57 | Supply and Fixing MCB, SPN, 230 Volt of capacity upto 32 Amps (as ordered), 10 KA \"C\" series complete all as specified directed. |
| 58 | Supply and Fixing MCB, SP, 230 Volt of capacity 6 to 32 Amps(as ordered), 10 KA \"C\" series Complete all as specified and directed. |
| 59 | M&L for sub main wiring with two single core, multi stranded,PVC insulated, 1100 Volt grade, FRLS,cable with copper conductor of size 2.5 Sq mm in and including/drawing throughthrough rigid non metalic PVC conduit medium grade, ISI marked, 25 mm dia for sub main wiring including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected common earth complete all as specified and directed. (Note :-2x 2.5 Sq mm conductor cable, 1 x 2.5 Sq mm conductor earth continuity cable & PVC conduit shall be measured as one unit length) |
| 60 | Taking down sub main wiring any size of two single core aluminium/ copper conductor cable PVC insulated alongwith/ without conduit and accessories and removing from site, making good the disturbed surfaces of wall and floor/ ceiling etc., Complete all as specified and directed. |
| 61 | Earthing complete for various equipments with galvanised steel earth plate electrode600 x 600 x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.Iwire 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GI pipe 20mm bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber plastered with 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion Complete all as specified and directed.Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate. |
| 62 | S & F Modular type Step Fan regulator, 120W - 2 module complete all as specified and directed. |
| 63 | S&F frame plate for modular switch 3 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 64 | S&F frame plate for modular switch 4 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 65 | S&F frame plate for modular switch 6module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed. |
| 66 | S&F MS Housing box 3 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 67 | S&F MS Housing box 4/5 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 68 | S&F MS Housing box 6 module suitable formodular switch as per existingswitch boxand making good to the disturb surfacecomplete all as specified and as directed. |
| 69 | M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed. |
| 70 | S & F LED lights fitting 20 watt, 220V, AC decorative box type Tube light with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. |
| 71 | S&F ceiling fan complete with blades, down rod, electronic regulater and accessories 230V,1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including writing MES Number complete all as specified and directed. |
| 72 | M&L for MCB Distribution board double doorTPN 4 way, sheet steel, powder painted for fixing MCBs of various rating capacityincluding taking down old unsv MCB DBs complete all as specified and as directed. |
| 73 | M&L for MCB SP 5-32 Amps, 10KA, 230 volts, 50 Hz\"B\" curve complete all as specified and as directed. |
| 74 | Supply and fixing 415 Volt,10KA B curve MCB TPN/FP 16 to 32 Amp complete with connection, testing and commissioning. complete all as specified and directed. |
| 75 | Supply, laying, testing and commissioning UG cable XLPE insulated 16 Sqmm 4 Core, armored heavy duty electric cable, 1100 volts grade with stranded aluminium conductor in trenches including suitable size of double grip cable gland and joiinting etc complete all as specified and directed |
| 76 | Supply & laying GI pipe lightgrade 40mm dia with all GI fitting such as union, sockets,elbow,bend,tee,etc complete fixed on walls/celling/roof etc complete all as specified and as directed. |
| 77 | S&F LED flood light fitting 70 watt 230V AC outdoor type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrossion resistant complete with driver and lamp including all necessary cinnection, bracket,nut bolt etc. complete all as specified and directed. |
| 78 | S& F three phase , metal clad socket male & female complete suitable for 20 Amps complete all as specified and as directed. |
| 79 | Deduct schedule of credit amount Rs. 1,18,773.00 to be deducted during AOC |