| 1 | Dismantling old unserviceable LT panels after disconnecting connected cables etc coplete all as specified and as directed. |
| 2 | Supplying, installing, testing and commissioning of weather and vermin proof LT panel of size suitable to accomodate the incoming and outgoing accessories factory fabricated as per existing IEC 60439 Part 1, outdoor cubical/KISOK type totally enclosed outer cage made out of 3.00 mm thick sheet metal and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm thick duly power coated internally and externally suitable for operation on 3 phase 4 wire , 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement, conistiting of sufficent Nos of circular cable entry holes at bottom only with suirable PVC/rubber /wooden bushes to prevent ingress of water /vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with internal wiring with copper conductorPVC insulated cable of adequate size, embedded in 150 mm thick PCC 1:2:4 type B-1, 150 mm thick foundation includingTPN PVC sleeve aluminium bus bar of size 250 Amps complete all as specified and as directedinclusive of following accessories :- (A) INCOMING :- (I) MCCB 160 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable , Microprocessor release type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 01Nos(B) OUTGOING :- (i) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 02 Nos(ii) MCB SPN 32 Amp - 02 No. (iii) Spare cubicles for expansion as per MCCB 4P Amps - 02 Nos.(iv) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing |
| 3 | (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as and including suitable size CTs (set of 3) - 01 No. (for Incoming feeder) vi) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. (vii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 4 | All as per ItemNo. 2here-in-before butinclusive of following accessories:-(A). INCOMING :- (i) MCCB 250 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type Microprocessor release type including spreader terminals- set of 04 and direct rotary handle -01No as per OEM specifications -01 Nos(B).OUTGOING: - (i) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications.-02 Nos(ii) MCB SPN 32 Amp - 03 No. (iii) Spare cubicles for expansion as per MCCB 4P Amps - 02 Nos.(iv) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing(v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (vi) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. vii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 5 | All as per ItemNo. 2here-in-before butinclusive of following accessories:-(A). INCOMING: - (i) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications.- (B).OUTGOING:- (i) MCCB 63 amp 16kA, 415V3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 03 No. (ii) MCB SPN 32 Amp - 01 No. (iii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (v) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. (vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 6 | All as per ItemNo. 2here-in-before butinclusive of following accessories:-(A). INCOMING: - (i) MCCB 200 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications - 01 Nos(B).OUTGOING: - (i) MCCB 160 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable , Microprocessor release type including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications- 02 Nos(ii) MCB SPN 32 Amp - 02 No. (ii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (v) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. (vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 7 | All as per ItemNo. 2here-in-before butinclusive of following accessories:-(i) MCCB 63 amp 16kA, 415V3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 01 No. (B).OUTGOING:- (ii) MCB SPN 32 Amp - 03 No. (iii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (v) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. (vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 8 | All as per ItemNo. 2here-in-before butinclusive of following accessories:-(A).INCOMING: - (i) MCCB 63 amp 16kA, 415V3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 01 No. (B).OUTGOING:- (i) MCCB 63 amp 16kA, 415V3 pole with Ics =100% Icu & including spreader terminals - set of 03 and direct rotary handle - 01 No,all as per OEM specifications - 01 No(ii) MCB SPN 32 Amp - 02 No. (iii) LED indicators - R/Y/B 240 V AC - 03 Sets of 03 Nos. per incoming & outgoing(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (v) MCB SP \"C\" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 2 Nos. (vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc. |
| 9 | Material and labour for Boring of holes under road, pavement, hard standing etc mechanically using trenchless technology for 100 mm bore GI pipe passing through cable for protection of cable complete all as specified and as directed. |
| 10 | Material and labour for galvanized iron tubing light grade size 50 mm bore with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. |
| 11 | Material and labour for galvanized iron tubing light grade size 100 mm bore with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protection complete all as specfied and as directed. |
| 12 | Dismantling and taking out old broken prestressed concrete poles in any location and of any size complete all as specified and as directed. |
| 13 | Dismantling cross arms ofMS channel or angle section etc. from poles /2 pole/ 4 pole structures completeall as specified and as directed. |
| 14 | Dismantling insulators any type, size and make from any location and height etc completeall as specified and as directed |
| 15 | Dismantling stay assembly complete (including demolition of concrete and excvation) with accessories complete all as specified and asdirected . |
| 16 | Dismantling earth wire conductor from any location, height complete all as specified and asdirected . |
| 17 | Taking down old aluminium conductors from poles in any location complete all as specified and as directed. |
| 18 | Taking down old unserviceable cables/ service cableof any size from any location and height complete all as specified and as directed. |
| 19 | Dismantling GI pipe off any size ,length ,make from any location complete all as specified and as directed. |
| 20 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm x 2 core complete all as specified and as directed. |
| 21 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm x 2 core complete all as specified and as directed. |
| 22 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm x 4 core complete all as specified and as directed. |
| 23 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm x 4 core complete all as specified and as directed. |
| 24 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm x 3.5 core complete all as specified and as directed. |
| 25 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 sqmm x 3.5 core complete all as specified and as directed. |
| 26 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 sqmm x 3.5 core complete all as specified and as directed. |
| 27 | Supply and fixing XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 sqmm x 3.5 core complete all as specified and as directed. |
| 28 | Excavation in trenchesn. exc 1.5m wide and not exc1.5m deep for foundations of poles, struts,stays and laying of cable, pipes etc and getting out as in soft/loose soilcomplete allspecified andas directed. |
| 29 | Material and labour for laying dry fine river sand in trenches as cushioning to underground cable for protection of cable in two layers 8 cm thick before laying of cables and 15 cm thick after laying the cable and complete all as specified and as directed .Note:- Only punned thickness of sand shall be measured for payment. |
| 30 | Material and labour for laying un-reinforced precast concrete cable cover, class LV type 2 , flat, size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 31 | Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n\"exc 50 m above the starting point complete all as specified and as directed. |
| 32 | Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as directed. |
| 33 | Material and labour for cement concrete 1:4:8 type D- 2 using 40 mm graded crushed stone aggregate in foundations, filling & mass concrete for poles/struts/stays assembly etc complete all as specified and as directed. |
| 34 | Material and labour for cement concrete 1:2:4 type B-1using 20mm graded crushed stone aggregate as in coping pedestal to poles including necessary frame work finishing the expossed surface even and smooth complete all as specified and as directed. |
| 35 | Demolition of oldbrick work built in cement mortar including all quoins,arches, pillars etc complete all as specified and as directed. . |
| 36 | Material and labour for brick work with sub class‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 37 | Material and labour for complete removal of existingpaint from external surface of11 m long steel poles including brackets from top of copingand prepration of steel surface of steel poles and applying two coats of aluminium paint,andtwo coats of synthetic enamel paint of colour black and red 1.50 m height from coping in alternate strips of 30 cm each including writing pole number with whitepaint on black base of250 mm dia with height of letters 50 mm complete all as specified and as directed, |
| 38 | Supply and fixing in repair LED LUMINARIE, pressure die cast aluminum housing, 45 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as specified and as directed. NOTE:--The Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. |
| 39 | Supply and fixing\"smart poles\"7.0 m long of octogonal cross section fabricated intenally and externally hot dipped galvanised 3mm thick steel sheet having top Dia 90 mm and bottem dia 185 mm and base plate 220 x 220 x12mm with intergral camouflaged junction box for incorporating controlgears with flust door with necessary locking arrangements,base plateto be grouted on suitable size shallow foundation with M-15 concrete with 700 mm long 04 Nos 20mm dia, bolts and 3 mm anchor plate, mounted with pole top mounting spigot type hot galvanised single arm street light mounting bracket single arm bracket 1000 mm in length complete all as specified and as directed. |
| 40 | Supply and fixing weather proof Copper conductor 1.5 sqmm 3 core, round cable for connection from looping box to street light fitting in side the existing pole complete all as specified and as directed. |
| 41 | Supply and fixing in replacement of old unvs box Street light control junction box 280x170x130mm from cable looping box to the connector of the luminarie made out of FRP sheetand arrangement3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 10 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable for mounting of box to pole /Angle of requiredsize & shapeincluding bolts nuts & washers complete all as specified and as directed. NOTE: - The quoted rate shall deemed be inclusive of cost of suitable size incoming & outgoing cable glands & lugs. |
| 42 | Supply and fixing in replacement of Three-Phase load of 5 KW for automatic Street Light control Switch using Infrared Sensor based NATURAL SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level, required illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should have part night operation facility of minimum 4 hrs. to max. 12 hrs. The Sensor along with 3 Nos suitable Contactor each 20 to 25 Amp current rating incoming MCBs & Outgoing MCBs of 20-25 Amps (03 Nos) and circuit should also have provision for manual operation (i.e. Sensor Bye-pass option). circuit should be multistrand FRLSH min size ofminmum 10 sq.mm copper cable. Selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compound (sintex made SMC junction box) confirming to IP 54 including taking down old unserviceable timer any type complete all as specified and as directed. |
| 43 | Taking down street light junction boxes, street light bracket etc alongwth all necessary fittings and refixing the same all as specified and as directed. |
| 44 | Material and labour for replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25 x 4 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified and as directed. |
| 45 | Supply and fixing in replacement Cable Route Indicator suitable to indicate route of LT Cable.Route indicater shall be madeof reinforcedcement conctete 1:2:4 type B-1using 20 mm graded stone aggregates slab of size 600x200x20 mm (HXBXT) reinforced with 4 no bars of 6 mm dia both way duly embossed the letter \"LT UG CABLE\" route indicator embedded in ground rested over PCC base of cement concrete 1:4:8 type D-2 of size 200x150mm including necessary excavation and shall be 40 cm above the ground level and 20 cm below the the ground level complete all as specified and as directed . |