Tender For Special Repair To Certain Billets At Af Stn Palam, Delhi Cantt-10; 1 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 Sqm each and removing from site and making good the disturbed portion in CM 1:3 or PCC 1: 2:4 type B-1 complete all as specified and directed. Note: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. 2 Taking down chowkats or frames with shutters (without taking off shutters from the frames) but exceeding 1.5 Sqm but not exc 4.00 Sqm each and removing from site and making good the disturbed portion in cement mortar 1:3 or PCC 1: 2:4 type B-1 complete all as specified and directed. Note: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. 3 Taking down shutters of any description exc. 1.00 Sqm and not exc. 2.00 Sqm each complete all as specified and directed. 4 Taking down shutters of any description n. exc. 1.00 Sqmeach complete all as specified and directed. 5 M&L for Mild steel framed work, confirming to Fe-290 Gde E-165, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and directed. 6 Supply and fixing factory made35 mm thick 2nd class Hard WoodPlain, framed, panelled shutters (two panel), with lock rail and panel of 9mm B.W.P.commercial ply or 12 mmveneered particle boardwith commercial veneeringon both faces. The size of rail and stiles as per IS:1003 (part-I),kiln seasoned and chemically pressure complete all as specified and directed.Note :Quoted rate deemed to include complete accessories for 140 mm long floor door stopper of aluminium alloy body for each leaf. 7 Supply and fixing Factory made Glazed and skeleton shutters, 35mm thick, in 2nd class Hard Wood,Plain, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded,edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass/gauzeetc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); complete all as specified and directed.Notes : Quoted rate deemed to include complete accessories for Mild steel 300 mm ordinary rat tail rod pattern springs including roller-arms roller plate for each leaf. 8 Supply and fixing window/Ventilator section of frame 72 x 55 mm fixed to wall or concrete surface with MS holdfast (30 x 5 mm section) 150 mm long made of galvanised steel powder coated and section of shutter 47 x 20 mm, mulion section 72 x 50 mm (base steel as per IS 513 D quality galvanized as per IS 277 with zinc of 120 gms/Sqm) glazed or gauzed and wire gauze shutter (Double door shutter) with total coated thickness of 0.60 mm including powder coated grill/guard bars made of square bars 10 mm dia at 150 mm c/c horizontal spacing fixed in MS flat frame (30 x 5 mm) fixed to windows frame with screws, including 4 to 5 mm thick sheet glass, 0.36 mm stainless steel wire cloth with 1.40 mm aperture necessary fittings and all builders hardware such as handles, tower bolts & stays etc complete all as specified and as directed.Note : Type-4000 series ref drg No CEAF/STD-191/2014 Sheet No 1/2 & 2/2. 9 Supply and fixing MS butt hinges 100mm size, cold rolled, medium weightfixed with screws to wooden frames or welding to steelframes etc complete all as specified and as directed. 10 Supply and fixing aluminium anodized barrel tower bolts of extruded section length of bolt 200 mm long complete all as specified and as directed. 11 Supply and fixing extruded aluminium alloy handles, fabricated type, anodised,150 mm size complete all as specified and as directed. 12 Supply and fixing aluminium sliding door bolt, 300 mm long,with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast aluminium alloy including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. 13 Material and labour for 18/19 mm thickprelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber framework including IInd class H.W leeping all round as in shelves of design as approved by Engineer in charge.etc and including dismantling boarding of any description fixed with screws complete all as specified and directed by Engr-in-Charge. Notes : Quoted rate deemed to include complete accessories (minimum 1.2 mtr piano hinges, 2 knobs, 50mm magnetic catches, 2 nos 100mm SS-304 Handles, 2nos Tower bolts for each cupboard shutter etc) 14 Hacking out old broken glass, any thickness, size, quality, or description from wooden/metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete upto 4th storey complete all as specified and as directed. 15 Supply and fixing forsheet glass 4mm thick ordinary quality glazing with oil putty in square n. exc. 0.5 Sqm in each pane fixing to wooden door/aluminiumwindow shutters in any position with new beads/ steel section as required for securing complete all as specified and as directed. 16 Supply and fixing for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixedwith tinned tacks or galvanised wire staples complete all as specified and as directed. 17 Supply and fixing in repairs for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixedwith tinned tacks or galvanised wire staples complete all as specified and as directed. 18 Supply and fixing in repair aluminium Drapery/curtain rod, 25 mm dia, not less than 1mm thick, powder coated finished including teak wood brackets & end knobas required with teak wooden curtain rings etc. (Min 2 Nos brackets, 02 Nos End knob,12 Nos Rings each door/ window) complete all as specified and as directed. 19 Material and labour for preparation of new or previously untreated surfaces of wood, of any description not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over & including one coat of pink primer complete all as specified and as directed. 20 Material and labour for preparation of old painted surfaces of wood and wood based material, of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 21 Dismantling wrought iron ormild steel work of any description not otherwise provided for complete all as specified and as directed. 22 Dismantling timber scantling 40 sqcm and over in section, in any position as in unframed work complete all as specified and as directed. 23 Dismantling asbestos cement (corrugated, semi corrugated etc,) sheets in roof coverings complete all as specified and as directed. 24 Dismantlingplain or corrugated steel sheeting any gauge, thickness, including nanital or similar patternsheets in roof coverings complete all as specified and as directed. 25 Supply and fixing for rolled mild steel work (FE 410 Grade, E-250 quality A) as in Roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties for roof including securing bolts etc complete all as specified and directed by Engr-in-Charge. 26 Fixing only rolled mild steel (FE 410 Grade, E-250 quality A) as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam tee, angle, channel or flat sections) includingdistance pieces, cleats etc. complete all as specified and as directed. 27 Material and labour for2nd class hard wood clean sawn timber framed and fixed in scantlings (as Roof trusses (framed), purlins, crane gantries, rails and fastenings and heavy bracket framing etc) complete all as specified and as directed. 28 Fixing only 2nd Class hard woodclean sawn timber framed and fixed in scantlings (as Roof trusses (framed), purlins, crane gantries, rails and fastenings and heavy bracket framing etc) complete all as specified and as directed. 29 S&FPre- paintedgalvalume aluminiumzinc coatingGI basedcorrugatedsteel sheet0.50 mmthickof anycolourhavingtensilestrengthof 550Mpa as in roof covering/cladding to wall fixed with self taping screws, rubber washer, etc. complete all as specified and as directed.Note:Pattern, design and colour shall be as approved by GE. 30 Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws with rubbur washercomplete all as specified and directed by Engr-in-Charge 31 Material and labour for cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in copings,bed plates,kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed. 32 Taking down and refixing wind ties for roof including securing bolts etc complete all as specified and directed. 33 Material and labour forpreparationofoldpaintedsurfacesofsteelandiron surfacesofany descriptionnototherwise described over10cm width&girth andapplying two coats of synthetic enamel paint complete all as specified and directed. 34 Material and labour for preparation of new or previously untreated surfaces of steel of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified and directed. 35 Dismantling ceiling board, any size or description, fixed in any position or in any thickness, including cover fillets with nails complete all as specified and directed. 36 Providing & Fixing false ceiling at any heights with semi-perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum false ceiling tiles of size 595x595 mm of approved texture, design and patterns having moisture content less than 2% , humidity resistance of 99%, NRCO.50 TO 0.75 as per IS 8225:1987, non-combustible as per BS 476 (PART 4) -1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000mm, cross-T of size 15x32 mm of length 1200 mm and secondary intermediate cross -T of size 15x32 mm of length 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2 mm, Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws complete all as specified and directed. 37 Complete repair work in existing ceiling board frame, any size or description, refixing of frame and ceiling tilesin any position or in any thickness, including cover fillets with nails complete all as specified and directed.Note:- Rate deemed to include material for necessary items such as T-Grid, suspender, galvanized mild steel items, level adjuster of any size, etc. as required at site. 38 Demolition of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness as in floors, aprons, etc. complete all as specified and directed. 39 Roughening surfaces of old concrete /terrazzo floor by picking, sweeping clean andwashing down with water to remove dust, etc. complete all as specified and directed. 40 Material and labour for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab (slab size not less than 55 cm x 55 cm )including rubbing andgranite (mirror) polishing laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. 41 Material and labour for machine cut kota stone slab flooring 20-25mm thick as in riser or steps, skirting, dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite ( mirror) polishing laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. 42 Material and labour forbeeswax polishing including rubbing of oldKota stone in floor , steps, skirting, dado, etc. with admixture of pigment to match the shade complete all as specified and directed. 43 Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc 15 cm thickness below or above ground level complete all as specified and directed. 44 Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. 45 Material and labour for rough finished surfaces of concrete Formwork tochullah hoods, chajjas, troughs and similar items including edges for flat, rough finished surfaces of concrete complete all as specifiedand directed. 46 Material and labour for providing reinforced cement concrete Type B-1, 1:2:4 (using 20mm graded stone aggregate) as in chajjas and similar work complete all as specified and directed. 47 Material and labour for TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 48 Material and labour for 75mm thick cement concretetype C-1, 1:3:6 (using 20 mm graded stone aggregate) as in plinth protections, to be finished even and smooth without using extra cement including provision of 10mm joints (at an interval of 3m and turnings) duly filled with fine sand and bitumen in the ratio of 3:1 including necessary formwork complete all as specified and directed. 49 Material and labour for providing 25 mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone agg) asin floor, etc complete all as specified and directed. 50 Material and labour for 75 mmthick cement concretetype D-2, 1:4:8 (using 40 mm graded stone aggregate) as in subbase complete all as specified and directed. 51 Material and labour for machine pressed, factory made, precast concrete interlocking paver block (glossy finish coloured) any shape and size, with grey cement and pigment confirming to IS 15658-2006 of 60mm thickness in M-35 grade laid over and including 50 mm thick sand cushioning complete all as specified and directed. 52 Material and labour for Pre polished chequeredcement concrete tiles30x30 cm x 25 mm thick (glossy finish coloured) set jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 20 mm thick screed bed in CM 1.4 complete all as specified and directed. 53 Demolition of brickwork built in cement mortar, including all quoins, arches, pillars, etc of any description including removing debris outside MoD land complete all as specified and directed. 54 Material and labour for brickwork with old size sub class `B bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 55 Material and labour for brickwork with sub class `B bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6but except bricks complete all as specified and directed. 56 Material and labour Brickwork with old size sub class B bricks, straight or curved on plan exc to any radius, in half brick thick wall built in CM 1:4 complete all as specified and directed. 57 Supply and fixing in repair 1200 mm x 600 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with C.P. screws and cap washers with teak wooden beads complete all as specified and directed. 58 Taking down cement plaster or cement lime plasteron brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. 59 Material and labour for rendering 15 mm thick cementplaster on fair faces of brickwork or concrete surfaces in cement mortar 1:6, to befinishedeven and smooth without usingextra cement complete all as specified and directed. 60 Material and labour for 15 mm thick cementplaster on fair faces of brickwork or concrete surfaces in cement mortar 1:4, to befinishedeven and fairwith water proofing compound by weight as per manufacturers instructions including necessaryscaffoldingup to 6mtr height complete all as specified and directed.Note : WPC will be measured and paid separately. 61 Supply onlyIntegral Water Proofing compound complete all as specified and directed. 62 Material and labour preparation of new plastered surfaces of wall and applying complete wall care putty 3 mm average thick over one coat ofalkalic resistent primerand two coats of oil bound distemper complete all as per manufacturers instructions anddirected by Engineer-in-Charge. 63 Complete removal of existing treatment from internal surfaces of wallsby mechanically and washing rubbing down and stopping of surface holes and cracks using necessary filling compound of white cement and fine sand in the ratio of 1:3 to obtain smooth regular/even finish using sand paper and including Material and labour for preparation of old surfaces and applying wall putty 3 mm average thickness over one coat of alkali resistant primer and two coats of oil bound distemper on wall etc complete all as per manufacturers instructions andas specified anddirected by Engineer-in-Charge. 64 Material and labour for preparation of new plastersurface of walls ,chajjas, soffits & beamincluding necessary scaffolding and applying wall care putty 3 mm average thickness with two coats of acrylic smooth exterior paint of required shade@ 1.43ltr/10sqmover a coat of exterior primer @ 2.20kg/sqm complete all as per manufacturers instructions anddirected by Engineer-in-Charge. 65 Material and labour for complete removal of old surface of walls ,chajjas, soffits & beamincluding necessary scaffolding and applying wall care putty 3 mm average thickness withtwo coats of acrylic smooth exterior paint of required shade @ 1.43ltr/10sqmover a coat of exterior primer @ 2.20kg/sqm complete all as per manufacturers instructions and directed by Engineer-in-Charge 66 Taking down copper/aluminium point wiring (light, fan, socket or power, etc.) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. any type complete all as specified and directed. 67 Taking down ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades to store yard and hanging ceiling fan in its original position or any other position as per direction of Engineer-in-Charge including its fittings and fixtures after carrying out the repairs i.e cleaning, rewinding, greasing and filling, replacement of bearings, painting of fan with one coat of synthetic enamel paint by spraying after preparation of surface by cleaning all dust and filling cavity with filler, reassembling the fan etc including testing complete all as specified and directed. 68 Taking down unserviceable sub main wiring with conduits/battens etc complete all as specified and directed. 69 Material and labour for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories suitable for mounting flush type switches including metal flush box and face plate with frame for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulated but unsheathed multistranded copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLS cable as continuous earth wire connecting to common earth dolly in concealed wiring system includes cutting of chasis and making good disturbed surfaces complete all as specified and directed for the following:- 70 One light/ fan point controlled by one switch one way 71 One 3 pin 5Amps socket outlet point on the same board controlled by one switch 72 One socket outlet 5 Amp controlled by one switch on independent board 73 All as per Srl item No 69.00 here-in-before but for one power point for 15 Amps socket outlet with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete all as specified and directed. 74 Supply and fixing flush type switch 1 way 6 Amps complete all as specified and directed. 75 Supply and fixing flush type switch 1 way 16 Amps complete all as specified and directed. 76 Supply and fixing socket outlet flush type, 6A, 2/3 pin complete all as specified and directed. 77 Supply and fixing socket outlet flush type 6A/16A, 2/3 pin complete all as specified and directed. 78 Supply and fixing in repair ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and directed. 79 Supply and fixing of step type fan regulator, 120W complete all as specified and directed. 80 Supply and fixing lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. 81 Supply and fixing in replacement LED bulb 9/12 watt fixed in pendent holder/bulk head complete all as specified and directed. 82 Supply and fixing in replacement LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light with and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 83 Supply and fixing in replacement of Vertical type load line distribution board, double door, 4 way, AC, 3 Phase, 415 volts, TPN bus bar 250 Amps rating and earth bus & din rail suitable for MCCB as incomer complete all as specified and directed. 84 Supply and fixing in replacement of MCCB 200 Amps 4 pole 36 kA 415 Volts 50 Hz with adjustable thermal and magnetic settings, necessary connection including taking out old existing unserviceable MCCB from panels/VTPN etc complete all as specified and directed. 85 Supply and fixing in replacement of MCB, SP, 40-63A, 15kA complete all as specified and directed. 86 Supply and fixing in replacement of MCB, SPN 40-63A, 15 kA complete all as specified and directed. 87 Supply and fixing in replacement of MCB, SP, 6-32A, 10KA complete all as specified and directed. 88 Supply and fixing in replacement of sheet metal enclosures for MCB distribution board SPN 8 way 240Volt with 200 Amps bus bar, neutral link, earth bar din rail conforms IS-8822:96 and EIC 898-96, double door complete all as specified and directed. 89 Material and labour for submain wiring with two single core 2.50 sq mm PVC insulated FRLSH multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 2.5 Sqmm multistranded copper conductor cable as continuous earth wire complete all as specified and directed. 90 Material and labour for submain wiring with two single core 4.00 sq mm PVC insulated FRLSH multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4.00 Sqmm multistranded copper conductor cable as continuous earth wire complete all as specified and directed. 91 Material and labour for submain wiring with two single core 6.00 sq mm PVC insulated FRLSH multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6.00 Sqmm multistranded copper conductor cable as continuous earth wire complete all as specified and directed. 92 Material and labourin repair for Earthing of complete with galvanized steel earth plate electrode 60cm x 60cmx 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-1 of 2009 and including excavation & earthwork in any type of soil, disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed. 93 Supply and fixing in replacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape 1.2 m long with 02 Nos clamp made out of 25 x 6mm Gl strip including drilling holes bending welding and made to clamps on building/concrete/Rail/Tubular pole complete all as specified and directed. 94 Supply and fixing in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. 95 Supply and fixing in replacement of LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed.