Provision Of Integrated Company, Equipment, Clothing, Sports Store And Mobilisation Eqpt Store Under Lbwp For 604 And 626 Garud Flight Under Ge (North) Bangalore; 1 Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out hard dense soil all as specified & directed 2 Removing excavated soil to a distance exc. 1.50 km but n exc. 5 km and depositing where directed all as specified & directed 3 Excavation in trenches not exc 1.5m wide and 1.5m deep and getting out in hard/dense soil for fundation and smilar work all as specified & directed 4 Excavation in trenches exc 1.5 m deep but not exc 3.00 m deep and getting out in hard/dense soil for fundation and smilar work all as specified & directed 5 Removing excavated soil to a distance exc. 250 m but n exc. 500 m and depositing where directed all as specified & directed 6 Returning filling in including spreading levelling, watering and well ramning in layers not exc 25 cms thick all as specified & directed 7 Earth Filling under floors or in foundations in layers n. exc 25cm thick including watering and consolidation all as specified & directed 8 M&L for Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete all as specified & directed 9 M&L for Reinforced cement concrete, design mix M-25 grade using 20mm graded stone aggregate, as in foundations footings, plinth beams, bases for columns, etc and mass concrete all as specified & directed 10 M&L for Reinforced cement concrete, design mix M-25 grade using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts all as specified & directed 11 M&L for Reinforced cement concrete, design mix M-25 grade using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span all as specified & directed 12 M&L for Reinforced cement concrete, design mix M-25 grade using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified & directed 13 M&L for Reinforced cement concrete, design mix M-25 grade using 20mm graded stone aggregate as in chajjas or similar item of work all as specified & directed 14 M&L for Formwork to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter, flat finished fair surfaces all as specified & directed 15 M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal fair finished surfaces all as specified & directed 16 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, etc. fair finished flat surfaces all as specified & directed 17 M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished flat surfaces all as specified & directed 18 M&L for Formwork to edges of concrete flats, treads, breaks in floors, window-cills, concrete railing, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide in rough finished flat surfaces of concrete all as specified & directed 19 M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges fair finished flat surfaces all as specified & directed 20 M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed 21 M&L for Mild steel TMT bars 8mm dia and over upto 10mm dia, cut to length, bent to shape required, including cranking, bending spirally as in Stirrups, binders, spacers all as specified & directed. 22 M& L for water proofing treatment over RCC slab with the following specification all as specified & directed :-(a) Rendering 15mm thick cement mortar (1:3) mixed with and including water proofing compound as per manufacturers instructions and dry after curing.(b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density o 0.87-0.89 Kg/Lit at 25º C on the prepared dry roof surface.(c) 3 mm thick APP modified membrane reinforced with non woven polyester matt with physical prosperities as under:- (I) Membrane weight>3.8 Kg/ sqm (ii) Non woven polyester weight>160 gm/Sqm (iii) Softening point of membrane >150º C (iv) Joint tensile strength longitudinal >650 Sqm Cm at 230º C & Transverse> 450/Sq Cm (v) Tear strength - longitudinal >300N & Transverse>250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm(d) Applying a coat of solar reflective bituminous aluminium paint @ 0.10 litre/sqm 23 M&L for Pre-cast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in solid block masonary exceeding 10cm in width setting in cement mortar (1:6) complete all as specified & directed 24 M&L for Pre-cast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in solid block masonary not exceeding 10cm in width setting in cement mortar (1:4) complete all as specified & directed 25 M&L for rendering 15mm thick in two layers i.e 10mm thick backing coat in cement mortar (1:6) and 5mm thick floating coat in cement mortar (1:4) mixed with water proofing compound on brick or concrete wall surfaces all as specified and as directed. (Note : WPC shall be measured & paid separately) 26 Supply only liquid water proofing compound, ISI marked all as specified & directed 27 M&L for rendering 10mm thick Cement moratar (1:6) on brick or concrete wall surfaces finished even & smooth without using extra cement all as specified and as directed. 28 M&L for rendering 5mm thick in cement mortar (1:3) on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like all as specified and as directed. 29 M&L for Hardcore of broken stone gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and as directed. 30 M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in 100mm thick sub base to floors, ramp etc.all as specified and as directed. 31 M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in 75mm thick flooring on ramp, finishing cement concrete surface even and smooth without using extra cement including Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green etc .all as specified and as directed. 32 M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in 25 mm thick flooring finishing cement concrete surface even and fair etc .all as specified and as directed. 33 M&L for PCC (1:3:6 ) type C-1 using 20 mm graded crushed stone aggregates as in 75 mm thick plinth protection etc, finished even and smooth without using extra cement including joints filling with sealing compound Grade A complete all as specified and directed. 34 M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in coping, hold fast and filling in steel frame of door/window back filling and in roof kerbs of mud stops, rounded or chamfered on edges cills, steps including necessary formwork etc; all as specified and directed. 35 S & F Butt hinges medium weight, cold rolled mild steel 100mm size and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed 36 S & F Aluminium anodized barrel tower bolt of extruded section of size 125mm long complete all as specified and directed. 37 S & F Extruded Aluminum handles 150mm size, fabricated type, anodised all as specified 38 M&L for Granite 18/20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed. 39 M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 40 M & L for Machine cut kota stone slab 20-25mm thick as in skirting , riser of steps etc and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed. 41 M & L for Screed bed or bedding layer 20 mm thick in cement mortar (1:4) for laying floor finishes etc complete all as specified and directed. 42 M&L for preparation of newly plastered surfaces of walls and applying two coat of cement base paint over one coat of white washing primer complete all as specified and as directed. 43 M & L for preparation of newly plastered surfaces of walls and applying two coats of Acrylic distemper over a coat of alkali resistant primer complete all as specificed and as directed 44 M & L for preparation of newly plastered surfaces of Ceilings, soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and applying two coats of of white wash complete all as specificed and as directed 45 M & L for Hard drawn steel wire fabric in available size weight not exc 4.00 Kg /sqm fixed in tank caging including welding, riveting, framing etc complete all as specified and as directed 46 S&F Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening of grade Fe-290 (Gde E- 165)and fixing complete all as specified and as directed 47 S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed 48 S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed 49 Supply and fix Sheet glass 4mm thick ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed 50 Supply only stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed all as specified and as directed 51 M & L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work as in ornamental type gate conforming to Fe.290.Gde-E-165 all as specified and as directed 52 M & L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces 53 M&L for Preparation of new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed. 54 M&L for Pressed steel door frames made of 1.25mm thick M S sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified & directed 55 M&L for Pressed steel door frames made of 1.25mm thick M S sheet of profile 125x60mm for door and window frames with two rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified & directed 56 S&F Flush door shutters 35mm thick, factory made as per IS:2202 (Part-I 1999) solid core construction, with block board core with decorative face veneer both faces with lipping / frame to match fixed to chowkhats all as speified and directed 57 S&F Second class hard wood 35 mm thick glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed (Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately) 58 S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed 59 S&F Aluminium handle 150 mm size, cast type, anodised etc complete all as specified and as directed 60 S&F Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed 61 S & F Floor door stopper of aluminium alloy, overall length of cover plate 140 mm, with hard down steel spring all as specified and as directed. 62 S&F mild steel ordinary rat tail rod pattern springs,including roller and roller plate 300mm size complete all as specified and as directed. 63 S&F PVC (SWR) pipe 110 mm dia single socketed in any length with rubber ring joint laid in trenches / fixed on floor / walls including jointing with solvent cement all as specified and directed. 64 S&F PVC (SWR) bends with access door any radius, 110 mm dia bore complete all as specified and directed 65 Excavation over areas not exc 1.50m deep and getting out in Hard / dense soil complete all as specified and directed 66 M & L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. 67 M & L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; 68 Extra for forming fair finished drain or channel 30 cm inner girth using extra cement including forms moulds, mitred/stopped ends etc complete all as specified & directed. 69 M & L for PCC in (1:2:4) type B-1 using 20mm graded stone aggregate as in surface channel & drain etc all as specified & directed. 70 M&L for rendering 15mm thick in CM 1:4 mixed with water proofing compound as per manufactures instructions on fair faces of brick work or concrete block walling surfaces finished even and smooth without using extra cement complete all as specified & directed 71 M & L for Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in cover slab for man holes and set in cement mortar (1:4) complete all as specified & directed 72 M & L for Point Wiring with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories including GI/ MS branded sunken boxes of suitable concealed on walls including frame and cover of fixed with cadmium plated iron screws for housing normal type switches, switch socket outlets, fan regulators etc., including provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- 72.1 One light point controlled by one switch 72.2 One fan/exhaust point controlled by one switch/regulator 72.3 One 3 pin socket out let 5 Amp on same board 72.4 One 3 pin socket out let 5 Amp on independent board 73 M & L for point Wiring with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concealed wiring including GI/ MS branded sunken boxes of suitable concealed on walls including fixed with cadmium plated iron screws for housing type switches, switch socket outlets, fan regulators etc., including provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. 73.1 Note for Item No. 72 to 73 :-(i) The earth wire for the points in the same circuit can be looped from point to point.(ii) Earth wire shall be taken inside the conduit.(iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring.(iv) Cost of a circuit of any length of cable from DB to any switch /socket board to be included in point wiring. (V) Cost of cutting/chaees for concealed point wiring is included in unit rate qouted rate . 74 S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. (Make: Bajaj Cat No.BCLAB 18 WH LED P or equivalent Make specified in P S herein after or as approved by GE). 75 S&F Switch piano flush type, single pole one way 5 Amps, 230 volts all as specified and directed. 76 S&F Switch socket combination 5 pin, 2 in 1, 5 Amps flush type 230 volts all as specified and as directed 77 S&F Switch socket combination 2 in 1, 3 pin 5 and 15 Amps, 230volts flush type universal all as specified and as directed 78 S&F MCB SPN 240 volts 32 Amps, C curves complete all as specified and as directed 79 S&F MCB single pole 240 volts 6 to 32 Amps, C curves complete all as specified and as directed 80 Supply and fix Modular Fan step regulator, 120Watts - 2 module, 230 volts as specified and as directed. 81 S&F MCB Distribution board SPN 4 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed. 82 S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals, 230volts all as specified and as directed. 83 M&L for Earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion including earth work and excavation in any type of soi,l PCC (1:3:6) type C1 chamber, pre cast RCC (1:2:4) type B1 slab 40mm thick with 8 mm TMT bars reinforced at 10 cm centre to centre both ways, funnel with G I medium grade watering pipe, G I protection pipe, wire mesh and lugs, test point complete all as specified and as directed. 84 S&F LED bldg security light fitting 30Watts with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection all as specified and as directed.( Make:- Bajaj Cat No.:- ENXT P 30L WH SY PC SD or equivalent Make specified in P S herein after or asapproved by GE). 85 S&F Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed. 86 S&F ceiling fans with complete accessories, 230Volts, Single Pole 1200 mm Sweep with BEE 5 Star rating with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed. 87 M & L for Sub main wiring 1100 volts grade multistranded FRLS copper conductors two runs of single core 2.5 Sqmm along with one run 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with & including PVC concealed conduit with accessories complete all as specified and as directed.(Note : Three run of 2.5sqmm cable and one run of conduit altogether measured as one unit) 88 M&L for sand cushioning with a layer of sand 23 cm thick under and above the cable all as per Para 19.75 of SSR Part-I complete all as specified and as directed 89 Supply & Laying sub class B burnt bricks for cable protection as per Para 19.75 of SSR Part-I complete all as specified & as directed 90 S&F G I tubing light grade 32 mm bore with all fitting laid in trenches / walls / Roads for cable protection all as specified & as directed. 91 Supply & Laying XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 2 core laid in trenches/ fixed on wall wall all as specified & as directed..