Bids Are invited for 8383950054 MOV,WCB,BF,WAFER,FLP ACTUATOR,8IN,150 Triple offset butterfly valve with actuator operated Size: - 8#, VALVE, ACTUATOR OPERATED Pressure Rating :- Class 150, End connection :- Flange end, Raised Face Body: ASTM A216 WCB, Disc: ASTM A351 CF8M Stem: SS 316, Seal ring: SS316+Graphite Leakage Class: VI, Design std: API 609, ASME B16.34 DIMENSION STANDARD CONFORM TO ANSI B16.5 Face to face std: API 609, Drilling Std: ASME B16.5 150 LB Packing: Graphite, Inspection & Fire Test: API 598 Ninth Edition Hydrotest: Tight shut off. Service: HVLRM Water/Foam 3 MOV should be smart type with in-built data logger facility. MOV should have non-inclusive remote setting facility. MOV will have both types (i.e. conventional hardwired & addressable Two wire Communication facility). Bidder has to go through MOV technical specification sheet. Bidder has to put signature & stamp on all paper as nod of approval. Total two nos. remote controller unit to be supplied along with each MOV Process data: 1) Service : Fire water 2) Pressure: 12 kg/cm2 (Max) 3) Temp: 40 Deg C Valve required with Electrical flame proof actuator Bidder has to submit the following with bid documents: 1. Vendor Drawing / Document Submission Schedule 2. List of deviations, if any. 3. MOV General Data sheets (duly filled in) (page no. 20 to 26 of Annexure-I). 4. G.A. Drawings and mounting details of actuators. 5. Wiring & connection diagrams. 6. Catalogue/ Brochures indicating complete technical details & data for actuator selection. 8383950064 MOV,WCB,BF,WAFER,FLP ACTUATOR,10IN,150 Triple offset butterfly valve with actuator operated Size: - 10#, VALVE, ACTUATOR OPERATED Pressure Rating :- Class 150, End connection :- Flange end, Raised Face Body: ASTM A216 WCB, Disc: ASTM A351 CF8M Stem: SS 316, Seal ring: SS316+Graphite Leakage Class: VI, Design std: API 609, ASME B16.34 DIMENSION STANDARD CONFORM TO ANSI B16.5 Face to face std: API 609, Drilling Std: ASME B16.5 150 LB Packing: Graphite, Inspection & Fire Test: API 598 Ninth Edition Hydrotest: Tight shut off. Service: HVLRM Water/Foam 9 MOV should be smart type with in-built data logger facility. MOV should have non-inclusive remote setting facility. MOV will have both types (i.e. conventional hardwired & addressable Two wire Communication facility). Bidder has to go through MOV technical specification sheet. Bidder has to put signature & stamp on all paper as nod of approval. Total two nos. remote controller unit to be supplied along with each MOV Process data: 1) Service : Fire water 2) Pressure: 12 kg/cm2 (Max) 3) Temp: 40 Deg C Valve required with Electrical flame proof actuator Bidder has to submit the following with bid documents: 1. Vendor Drawing / Document Submission Schedule 2. List of deviations, if any. 3. MOV General Data sheets (duly filled in) (page no. 20 to 26 of Annexure-I). 4. G.A. Drawings and mounting details of actuators. 5. Wiring & connection diagrams. 6. Catalogue/ Brochures indicating complete technical details & data for actuator selection. 4856430503 MOV,VLV,GT,A216-WC6,FLANGED,600,8IN (with integrated bypass MOV Gate valve 3/4in, #600, WC6) 2 All Valves are to be supplied as per MOC & Specification mentioned in conjunction with custom bid specification document sheet, Technical Notes for Valves IOC/M&I/MECH/P/4/2013 Rev.4 and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station IOC/M&I/ELECT/E/18/2012 Rev 0. Test reports shall be supplied for all mandatory tests as per the scope of inspection mentioned in Technical Notes for Valves and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station. Test reports shall also be furnished for any supplementary tests. Material test certificates (physical property, chemical composition & heat treatment report) of the pressure containing parts shall be furnished for the valves supplied. Material test certificates for the other parts shall also be furnished for verification during inspection. All the items shall be inspected and approved by IOCL approved third party inspection (TPI) agency. Original certificate from IOCL approved TPI agency is to be submitted along with supply. QAP is to be submitted by the bidder. Bidder has to submit the following with bid documents: i) Vendor Drawing / Document Submission Schedule ii).List of deviations, if any. iii).Data sheets (duly filled in) (page no. 20 to 26 of Annexure-I). iv).G.A. Drawings and mounting details of actuators. v).Wiring & connection diagrams. vi).Catalogue/ Brochures indicating complete technical details & data for actuator selection. 4899956574 MOV, VLV,GT,A217,WC6,BW,8IN,600 (with integrated bypass MOV Gate valve 3/4in, #600, WC6) 3 All Valves are to be supplied as per MOC & Specification mentioned in conjunction with custom bid specification document sheet, Technical Notes for Valves IOC/M&I/MECH/P/4/2013 Rev.4 and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station IOC/M&I/ELECT/E/18/2012 Rev 0. Test reports shall be supplied for all mandatory tests as per the scope of inspection mentioned in Technical Notes for Valves and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station. Test reports shall also be furnished for any supplementary tests. Material test certificates (physical property, chemical composition & heat treatment report) of the pressure containing parts shall be furnished for the valves supplied. Material test certificates for the other parts shall also be furnished for verification during inspection. All the items shall be inspected and approved by IOCL approved third party inspection (TPI) agency. Original certificate from IOCL approved TPI agency is to be submitted along with supply. QAP is to be submitted by the bidder. Bidder has to submit the following with bid documents: i) Vendor Drawing / Document Submission Schedule ii).List of deviations, if any. iii).Data sheets (duly filled in) (page no. 20 to 26 of Annexure-I). iv).G.A. Drawings and mounting details of actuators. v).Wiring & connection diagrams. vi).Catalogue/ Brochures indicating complete technical details & data for actuator selection.4894582263 MOV, VLV, GT, A216WCB, 13%CR, BW, 150, 8IN (with integrated bypass MOV) 2 All Valves are to be supplied as per MOC & Specification mentioned in conjunction with custom bid specification document sheet, Technical Notes for Valves IOC/M&I/MECH/P/4/2013 Rev.4 and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station IOC/M&I/ELECT/E/18/2012 Rev 0. Test reports shall be supplied for all mandatory tests as per the scope of inspection mentioned in Technical Notes for Valves and Technical Notes (General Specification) for Electrical Motor operated valve actuator and master station. Test reports shall also be furnished for any supplementary tests. Material test certificates (physical property, chemical composition & heat treatment report) of the pressure containing parts shall be furnished for the valves supplied. Material test certificates for the other parts shall also be furnished for verification during inspection. All the items shall be inspected and approved by IOCL approved third party inspection (TPI) agency. Original certificate from IOCL approved TPI agency is to be submitted along with supply. QAP is to be submitted by the bidder. Bidder has to submit the following with bid documents: i) Vendor Drawing / Document Submission Schedule ii).List of deviations, if any. iii).Data sheets (duly filled in) (page no. 20 to 26 of Annexure-I). iv).G.A. Drawings and mounting details of actuators. v).Wiring & connection diagrams. vi).Catalogue/ Brochures indicating complete technical details & data for actuator selection Total Quantity : 23