Supply, Installation, Testing And Commissioning Of Vrf And Split Ac Units Of Various Capacity For Msrlm. , High Side , Supply Of Vrf Outdoor Units , Vrv/Vrf System Of Air-Cooled Type Outdoors Suitable For Working On R410a, Shall Be Fully Weather Proof, Factory Assembled & Prewired With All Accessories & Electronics & Refrigerant Controls Housed In A Powder Coated Ms Sheet Metal Housing. The Outdoor Unit Shall Be Pre Charged With First Charge Of Refrigerant. Additional Refrigerant Charge Shall Be Added As Per Refrigerant Piping. The Compressors Shall Be Hermitically Sealed Inverter Scroll Type With A Combinationvariable Speedcompressors One Of The Compressor Shall Be A With Electronic Controls Capable Of Loading & Unloading Between 30% Capacity To 100% Capacity Of The Unit. Unit Should Deliver 100% Capacity At 43Degree Celsius And Nonstop Operation Even At 56Degree Celsius. Machine Should Have Twin Largest Accumulator As Per Odu Design. Outdoor Pcb To Be Coated With Special Acrylic -Based Polymer Films. , 36Hp , 32Hp , Supply Of Vrf Indoor Unit , Ductable Split Type / Cassette Type Ceiling Mounted Unit. , Light Weight Compact Ceiling Mounted Type With Corrosion Resistant Powder Coated Gi Casing With Dual Flap System With Wide Angled Louvers Suitable For Room Application As Per International Standards. Forward Curved Centrifugal Blowers Dynamically As Well As Statistically Balanced With Heavy Duty Blower Motor With High Degree Of Reliability And Energy Efficiency (Furnish Eer)Sandwiched Type Insulated Drain Pan With Complete Leak Proof Arrangement For Drain Water Outlet. Machine Cost Includes Remote Controllers, Refnet Joints Etc. Centralised Control System For Easy Provision Of Effective Control For Monitoring Of Vrv System Of The Total Building With Control And Monitoring Functions Of Temperature Setting , Fan Speed Setting Filter Alarm Operation Mode Error Code & Energy Saving Function Etc. (Provide Detailed Future Of The Control System.)To Be Included In The Cost , Ductable Unit Of 6.0 Tr Capacity And Cfm 2300 , Ductable Unit Of 3.0 Tr Capacity And Cfm 1200 , Cassette Unit Of 2.8 Tr Capacity And Cfm 945 , Cassette Unit Of 1.7 Tr Capacity And Cfm 650 , Cassette Unit Of 1.3 Tr Capacity And Cfm 470 , Cassette Unit Of 1.0 Tr Capacity And Cfm 470 , Compact Cassette Unit Of 0.8 Tr Capacity And Cfm 385 , Compact Cassette Unit Of 1.3 Tr Capacity And Cfm 412 , Compact Cassette Unit Of 1.0 Tr Capacity And Cfm 385 , Split Unit , Supply Of Dx-Mega Split Unit Of 3.0 Tr Capacity. Anti-Corrosive Condenser Fins-Blue, Evaporator Fins-Hydrophilic-Gold, Superior Anti-Rust Coating On Outdoor Unit, Self-Clean Technology, Turbo Cool, 100% Copper, Comfort Sleep , Low Side , Installation, Testing And Commissioning Of Vrf Outdoor And All Indoor Units. Indoor To Be Installed Proper Angle Frame, Thread Roads. Outdoor Units Ms Stands With Epoxy Painted And Ms Copper Piping Supports, Additional R410gas To Be Filled. Cost To Be Included Refnet Installation Also. The All Lifting Shifting By Crain, Labour And Transportation Till The Site Location And Dismantling Of All Existing Indoor Units And Outdoor Units To Be Included In The Scope. The Fire Retardant Canvas Connection For Ductable And Wherever Required. Required Civil Openings And Any Modification In Civil For Machine Installation, Copper Piping To Be Incorporated. , 36Hp System , 32Hp System , Refrigerant Piping , Supply, Installing, Commissioning & Testing Of Insulated Copper Refrigerant Piping Between Indoor Unit & Outdoor Unit Complete With Branch Distribution Joints Including All Fittings & Nitrile Rubber Form Insulation Considering The Locations Of Outdoor Units & Indoor Units For Different Residential Floors. Refrigerant Piping Between Indoor And Outdoor Units With Fittings And Accessories With 13/19 Mm Nitrile Rubber Insulation, All Outside. Refrigerant Piping Between Indoor And Outdoor Units With Fittings And Accessories With 13/19 Mm Nitrile Rubber Insulation, All Outside. The Following Is The Description For Incoming Section Of The Panel. , 41 Mm (1 5/8) , 35 Mm (1 3/8) , 28 Mm (1 1/8) , 22 Mm (7/8) , 19 Mm (3/4) , 16 Mm (5/8) , 12.5Mm (1/2) , 9.5Mm (3/8) , 6.5Mm (1/4) , For Server Room Hi-Wall Split Unit , Communication Control Cabling Between Indoor To Outdoor Unit. , Supply, Installation & Testing Of Copper Shielded Cable Size Of 0.75Sqmm X 2Core Laying In Black Pvc Conduit Pipe For Control Cabling With Required Accessories. , Supply, Installation & Testing Of Copper Cable Size Of 1.5Sqmm X 4Core Laying In Black Pvc Conduit Pipe For Control Cabling With Required Accessories. , Supply, Installation & Testing Of Copper Cable Size Of 1.5Sqmm X 3Core Laying In Black Pvc Conduit Pipe For Control Cabling With Required Accessories. , Supply, Installation & Testing Of Pvc Drain Piping With Nitrile Rubber Sleeves. Insulation Sizes Are 9Mm Thickness. , Dia. 25 Mm , Dia. 32 Mm , Buy Back , Less Buyback Old Existing Units - Buy Back Of Old Acs As Is Where Basis