Tender For Annual Plan-Vazhayoor Grama Panchayath Fhc Pump House Wiring-S0498/25-General Electrical Work - wiring 2 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 3 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 4 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 5 OD20554/2025-2026:2 X 25 mm X 3 mm G.I. strip test joint Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system 6 OD20560/2025-2026:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate 7 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 8 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 9 OD20553/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required 10 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) 11 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N 12 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 13 90.14.24.3:Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors. 14 OD20550/2025-2026:supply and fixing Digital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED 15 OD20557/2025-2026:Supply and fixing Danger notice board of size, 125 x 75 mm 16 OD20555/2025-2026:supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required 17 OD20717/2025-2026:Supply , Conveyance, Installation, Testing and commissioning DOL motor Controller Suitable for up to 7.5HP submersible motor pump set and giving necessary connections etc as required (L&T MU-G10H-DOL (Heavy duty) Controller) 18 OD20561/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-6535-STD-NF] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required. 19 OD20548/2025-2026:Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board 20 OD20547/2025-2026:Supplying and fixing63 A, HRC Fuse with HRC Fuse link with connections, in existing meter board 21 OD20801/2025-2026:Dismantling the existing damaged TPN, RCCB, Fuses motor starter and other all acessories from the existing panel board cleaning scraping and painting with one coat ofsuper enamelled paint over a coat of redoxide primer and giving all connections includung trial run of existing pumpset etc as required at site. 22 OD20644/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required.