}

Tender For Work Of Maintenance Of 11 Kv, 33 Kv And Ht/Lt Lines In The Area Of Edd-Pilua Under Edc, Etah - Safe Carriage Of 8.5 Mtr. Long Pcc Pole From Store Center Etah/Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 60 Km. Including Loadin, etah-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited has published Tender For Work Of Maintenance Of 11 Kv, 33 Kv And Ht/Lt Lines In The Area Of Edd-Pilua Under Edc, Etah - Safe Carriage Of 8.5 Mtr. Long Pcc Pole From Store Center Etah/Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 60 Km. Including Loadin. Submission Date for this Tender is 11-08-2025. Overhead Line Tenders in etah Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50508108
Tender For Work Of Maintenance Of 11 Kv, 33 Kv And Ht/Lt Lines In The Area Of Edd-Pilua Under Edc, Etah - Safe Carriage Of 8.5 Mtr. Long Pcc Pole From Store Center Etah/Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 60 Km. Including Loadin
Tender
Indian
Uttar Pradesh
Etah
11-08-2025

Tender Documents

Tender Details

Tender For Work Of Maintenance Of 11 Kv, 33 Kv And Ht/Lt Lines In The Area Of Edd-Pilua Under Edc, Etah - Safe carriage of 8.5 mtr. long PCC pole from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 2 Safe carriage of11/13 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 3 Safe carriage of9 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 4 Safe carriage of line material from store center Etah/nearest substation to pit site in distance range 0 to 60 Km. including loading & unloading at both ends. 5 Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place. 6 Dog/ Raccoon/ Rabbit conductor 7 AAAC/ACSR weasel conductor/ GI wire. 8 ABC 3X95+1X35+1X16/3x50mm 9 ABC 3x120+1x70+1x16 10 Erection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 11 Erection of 9 mtr. STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 12 Erection of 11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes 13 Erection of 8.5 mtr. long PCC poles as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete. 14 Errection of 11mtr. STP as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete. 15 Laying stringing & sagging of 3 phase 3 wire 33/HT/LT line with following condudctor including binding & nozzling. 16 Dog/ Raccoon/ Rabbit conductor 17 AAAC/ACSR weasel conductor/ GI wire. 18 ABC 3*95 mm/3*50 mm 19 ABC 3x120+1x70+1x16 20 Straighting of tilted PCC poles/ST P/Railsingle support of HT/LT line after opening of nuzzling, digging of pit applying anti direction force for making of proper alignment of line. 21 Straighting of tilted D/P after opening of connection applying anti direction force, digging of dug for proper alignment of line including reconnection etc. complete. 22 Opening of HT/LT connections & lowering of followingT/F from D/P/Plinth and shifting up to in safer place. 23 25/63 KVA T/F 24 100 KVA T/F 25 Dismanteling of old/damage STP/RS Joistof HT/LT line andcarriage to store centre Etah 26 Re-sagging of loose 33/HT/LT conductor after opening, binding, nozzling etc. 27 Dog/ Raccoon/ Rabbit conductor 28 AAAC/ACSR weasel conductor/ GI wire. 29 ABC 3X120+1X70+1X16 30 ABC 3X95+1X35+1X16 31 ABC 3X50+1X35+1X16 32 Replacement of following broken/damaged/missing accessories by new accessories including opening of the same and refixing. 33 1-11 KV cross arms V type 34 2-11 KV pin insulator 35 3-11 KV pin with nut 36 4-11 KV Disc insulator 37 5-Cross Arms holding clamps 38 6-F Clamps 39 7-LT shackle insulator 40 8-33 KV cross arm. 41 9-33 KV pin with nut 42 10-33 KV pin insulator 43 Retightening of Stay rod. Etc. complete. 44 Providingfixing of stay rod with nuzzling etc. complete. 45 Consumeable like nut & bolts of off size, cleaning chemical/material, cleaning clothes, insulated tape etc. will be required to complete the work shall be at contractor cost. 46 Earthing of PCC/RS Joist/STP as per RESPO norms. 47 Carriage of old material from pit site to JE store/store center, Etah in distance range 0 to 10 km including loading & unloading and proper stacking. 48 Mounting of Following Transformers on double pole/Plinth including making of the connection etc complete. 49 25/63 KVA T/F 50 100 KVA T/F 51 Chopping of tree branches 52 Repairing/ Resagging / new guarding of HT lines with GI wire as per RESPO norms

Key Value

Document Fees
INR 1180 /-
EMD
INR 5000.0 /-
Tender Value
INR 5 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail