| 1 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc.,as per SS 20 A. TNDSS NO: 23 & 24 VI (S2) VI,VII 9,10with standard specifications. |
| 2 | Footings |
| 3 | Grade Beam |
| 4 | Supplying and filling in foundation andbasement with filling M- sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.(TNBP No . 24 & 25) |
| 5 | Plain Cement concrete 1:4:8 (one cement, four sand, eight aggregate) using 40mm gauge handbroken granitestone jelly for foundation including dewatering if foundnecessary and laid in layers of not more than 15 cmthick and compacted,etc., complete complying withstandard specfication.(SI No 120 & 122) (TNBP No 28) |
| 6 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed (SI 154-A) TNBP No.- spl |
| 7 | Footing,Grade Beam,Plinth Beam |
| 8 | Columns |
| 9 | Beams and Slabs |
| 10 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) |
| 11 | Upto Basement |
| 12 | Ground floor |
| 13 | First floor |
| 14 | Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors.TNBP-spl |
| 15 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification |
| 16 | Up to Basement |
| 17 | Ground floor |
| 18 | First floor |
| 19 | Brick Partition Walls using II class ground moulded country bricks of size 8 3/4\" x 4 1/4\" X 2 3/4in C.M 1:3using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm |
| 20 | First floor |
| 21 | Second floor |
| 22 | Supplying and filling in foundation andbasement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.(TNBP Spl) |
| 23 | Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open) from theprofile the size of outer frame 60mm x 58mm andshutter profile are reinforcement with GI/1mm 125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames.The window should be got approved from the ExecutiveEngineer before use on work |
| 24 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.TNBP -Spl |
| 25 | Painting two coats over the new iron work with Ready Mixed Enamel Paint of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. |
| 26 | Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 27 | Plastering with cement mortar 1:5 (One cement and five sand) ,12 mm ,thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications (S.I.306) |
| 28 | Plastering with cement mortar (1:3) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications |
| 29 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being 32 : 12.5 well beated with wooden beaters for giving required slope and thickness 80mm as directed by the departmental officers etc., complete.(S.I.No.278) |
| 30 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete TNBP-Spl |
| 31 | White washing two coats with freshly burnt shell lime white in all floors including cost of lime and other materials brushes scaffolding charges etc, complete as per standard specification |
| 32 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 33 | Providing UPVC (Un-Plasticized Polyvinyl Chloride)Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber systemwhich provides high insulation properties with outerframe 60mm x 55mm with an outer wall thickness of2.4mm. The window unit should be designed with allcorner joints mitred and fusion welded. Windowsshould be steel reinforced with 25 x 24 x 25mm steelreinforcement with a thickness of 1mm to havedimensional stability. The sash should be of 60 x102mm. The mullion should be of 60 x 74mm. Theprofiles should have co-extruded seals.Hardware: All the hardware like friction stays, handlesshould be screwed with self tapping screws. Thehandles, locks should be designed so that they cannotbe released from outside.Glazing: The window system should be glazed with5mm plain float glass / 6mm bison lamInstallation: The profiles should be cut to length andwelded 45 degrees. The window should be designedsuch that the water drainage does not pass throughthe reinforcement chamber. The window systemshould be fixed directly to the plastered brick wallusing self expanding nylon plug and driving mselectroplated screws into plug. |
| 34 | Supply and fixing of Teak wood fully panelled and Double leaf (two Equal Panels) shutter for door including all labour charges cost and conveyance of all materials to site etc., Complete as per standard specification. |
| 35 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 36 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed etc., complete.as per standard specification(S.L No 261 a) |
| 37 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement (TNBP- Spl) |
| 38 | UPVC VentilatorSpecification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided inthe louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 39 | Fabricating supplying and fixing ofRoofing with Galvanised Coruugated Iron Sheet of 0.8mm thickness - 10 m2or any other approved design and to be fixed with shelf tapping screws, plastic washer. The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets. The sheet to be fixed with making suitable corrugated, cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 40 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 41 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications (TNBP- Spl) |
| 42 | Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia ‘B’ Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc (SOR -M-0552) |
| 43 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 44 | Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm \"P\" os \"S\"\" trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank. |
| 45 | Manufacturing, Supplying and Fixing of Stainless Steel Handrails for staircase near wet riser using 50mm dia 304L GradeStainless Steel pipe of 1.60mm thick will be provided withtubular supports made of 304L Grade Stainless Steel pipe of25mm dia of 1.60mm thick welded to the railing. Thesupports will be grouted into the wall and provided with93.00mm thick Stainless Steel circular base plate of 304Grade. The rate shall included for grouting into concrete withnecessary supporting arrangements the hand rail in floorpolishing buffing, bonding, cutting, grinding, conveyance,welding charges, electrical charges, etc. complete (PWD SOR -M-0651) |
| 46 | Supply and fixing of 1000 lit capacity HDPE tank of ISI make with all accssessories and the cost shall inclusive of conveyance charges, fixing charges etc complete as per standard specification. |
| 47 | Supplying laying and jointing the glazed S W pipes of 100mm size of approved quality with spigot and socket ends in dry condition with spun yarn and cement joints required depth for tranches including petty masonry,shoring and strutting wherever found necessary, and laying the pipeline in the alignment at the specified gradient and testing with necessary tools and plant etc. and levelling the ground complete complying with standard specifications. |
| 48 | Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessaryscaffolding charges. |
| 49 | 25MM dia,PVC pipe |
| 50 | 20mm dia.PVC pipe |
| 51 | Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve (Heavy type) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of G.I.Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements. |
| 52 | 20mm dia G.M.Gate Valve |
| 53 | 25mm dia G.M.Gate Valve |
| 54 | Suppling and fixing in position15mm.diameter brass screw down tap(heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac , thread etc.complying with standard specifications and including cutting and threading wherever necessary. |
| 55 | Supplying and fixing in position P.V.C. specials such as plain bend, door bend, plain tee, door tee, offsets,Y-junction, plain or with door of various sizes best quality confirming to I.S.S and providing leakproof joints including fixing to wall and giving connection to the P.V.C, soil stacks, dismadling the brick masonry or R.C.C.floor or Roof slab and redoing the dismandled portion to original condition etc., complete complying with standard specifications. |
| 56 | 110mm dia PVC DoorElbow |
| 57 | 110mm dia PVC Door Tee |
| 58 | 90mm dia PVC. Plain Elbow |
| 59 | 90mm dia PVC. Plain Tee |
| 60 | Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitaryfittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications. |
| 61 | 90mm dia |
| 62 | 110mm dia |
| 63 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23 |
| 64 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38 |
| 65 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. SD 54 |
| 66 | Supply and fixing of single box type 4\"40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting SD 88 |
| 67 | Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work.SD 234 |
| 68 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 A per way with 100 A TPN MC switch with suitable trunking box Ms cable entry boxes and internal connection on suitable angle iron frame work with earth connectionSD. 177 |
| 69 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (lik standard make) SD. 179 |
| 70 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m SD.75 |
| 71 | Supply and run of 4 X 6 sq.mm (84/0.3) 7/20sqmm PVC unshealed copper cable in suitable PVC rigid pipe concealed on wall and ceiling withcontinuos earth wire connection of 14 SWG TCwire with painting of suitable colour SD 68 |
| 72 | Supply and fixing of 1200mm (48\") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\") SD106 |
| 73 | SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL -2.0 TR Split Type AC Unit - 5 Star Rated (PWD - SOR -M-1985) |
| 74 | SUPPLY&INSTALLATIONOFAIR-CONDITIONER WITH COPPER COIL-Supplyandinstallationof5KVAcapacityAutomatic Voltage Stabilizer with time delay relay (PWD - SOR -M-1989) |
| 75 | SUPPLY&INSTALLATIONOFAIR-CONDITIONER WITH COPPER COIL-Supply and fixing of MS stand for fixing outdoor unit (PWD - SOR -M-1991) |
| 76 | SUPPLY&INSTALLATIONOFAIR-CONDITIONER WITH COPPER COIL-Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit (PWD - SOR -M-1990) |
| 77 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre \"T\". The \"T\" shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of \"T\" section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of \"T\" section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile \"L\" Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level andshould present a neat look M-0689 |
| 78 | supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceilingwith suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (PWD - SOR -M-1284) |
| 79 | Supply and fixing ofFire Extinguisher Co2, 4.5 kg. confirming to TAC Norms (SOR- M- 1982) |
| 80 | Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.(a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic(USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No.& Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., LowPressure Switch - 1 No., Level Switch - 1 No. & NecessaryCPVC Pipes and Fittings.The system shall be provide with Two Panel Control Systemwith necessary Stainless Valves and Fittings and Float Controletc. The rate should be inclusive of all civil works, wherevernecessary to install the System in position and intact. (PWD SOR -M-0721) |
| 81 | 250 Litres |
| 82 | Passenger Lift with M/C room, Speed 1.5 m/swith Stainless Steel Panels, Disable friendly,microprocessor based controller, VVVF drive, Firerated doors and ARD.( PWD SOR -M-2364) |
| 83 | Supplying and filling of HGB 40mm ISS metal complete complying with standard specification. |
| 84 | Supplying and filling of HGB 20mm ISS metal complete complying with standard specification. |
| 85 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 86 | Geophysical investigation charges etc.Complete. |
| 87 | Drilling of borewell inside well 150mm dia for Hard Rock including cost of all labour charges and transportation,Hire charges for rigs, fuel charges etc.complete. |
| 88 | Supply and delivery of 160mm PVC Casing Pipe including cost of Pipe and Conveyance charges and all material and all labour charges etc.complete. |
| 89 | Supply and delivery of clear water vertical wet type submersible pump conforming toIS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable ofdischarging noted LPM against head of water column due to all causes. The pumpshall be with stainless steel shaft and dynamically balanced bronze or Cast SSimpeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. Thepump shall be directly coupled to a continuos rated two pole suitable wet typevertical squirrel cage induction motor suitable for operation in AC single phase 230V+/- 10 %,50 HZ +/-5 % (lpm 15xm 50) (1.0 HP) |
| 90 | Supply and delivery of 40mm Dia u PVC Coulum pipe for Submersible Pipe Heavy type with ISI Mark each pipe 3m Length with Coupler Joint including cost of Pipe and conveyance charges etc complete. |
| 91 | Supply and Delivery and Fixing of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER (6sqmm Cable) |
| 92 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 andas amended thereafter with suitable KW rating for operation in AC/singlePhase/50HZ(± 5%) and 230 V(±10%) including Ammeter, Voltmeter, ThermalOverload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection,Indication lamp, starting capacitor, running capacitor and On/Off Push buttonswitches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulatedcable, powder coated vermin proof box including the capacitor (the cost of capacitoris to be taken separately).(1.0HP) |
| 93 | Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements etc., |
| 94 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth valves erection clamps, pressure gauges uptp the exterior wall of pump room and erection of panel board consisting of TPICN swithces starter, voltmetre, ammetre, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10days. |
| 95 | Supply and Fixing of CCTV Camera with Specification of Dahua- HAC-HFW 1100DP-B-0600 720P 1 Mega Pixel AnalogHigh Definition camera, outdoor-25/30 fps@720P,1/2.9\" 1 Megapixel CMOS, 50m IR,ICR, 6mm Lens optional, IR Bullet Dahua - Channel - AHD, High Video Quality on HD 1080N, Transmit Video Signal, audio signal & Dual way data communication signal over one coaxial cable, HD Video transmission without Video quality loss & delay, extremely, long transmission distance (300), as directed by Departmental Executive Engineer. |
| 96 | Supply and Installing sony CCTVcameraLMR (Electrical SOR 2021-22 Part-Q item no.43) |
| 97 | 29\" Led TV for display LMR |
| 98 | Poe suitable for CCTV IP camera 24 port |
| 99 | Rack With Accesssories - 12U Rack |
| 100 | Armoured LAN & CCTV Cable Cat 6 |
| 101 | Hard Disk For NVR(8TB) |
| 102 | Network Video Recorder for CCTV 16 Channel |