}

Tender For Electrical Work Sathivada, Vizianagaram-Andhra Pradesh

Union Bank Of India has published Tender For Electrical Work Sathivada. Submission Date for this Tender is 11-08-2025. Construction Material Tenders in Vizianagaram Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50496686
Tender For Electrical Work Sathivada
Tender
Indian
Andhra Pradesh
Vizianagaram
11-08-2025

Tender Details

Tender For Electrical Work Sathivada => Limited; 1 a Supply and wiring of Light and fan Points with Switch, MS Box Plate and also Suitable Size 2mm thick PVC conduit with 3x1.55qmm Copper multi strand flexible pvc insulated cable with required all Materials etc. (Rate Including the circuit wiring from Lighting Distribution Board to Switch Board Wiring 2x2.5+1.5Sqmm Wire and PVC conduit) Primary Point b Supply& wiring Looping/Secondary Point(Without switch) Supply & Wiring Supply and wiring of Bell point with bell Push and Ding Dong Bell with Suitable Size 2mm thick PVC conduit with 3x1.5Sqmm earth wire Copper multi strand flexible pvc insulated wires and 5A Switch cum sockets with Surface/concealed Box with required all materiais etc Supply & Wiring 2 Supply and wirning of Wall Mounting Fan points from Near Switch Board with Suitable Size 2mm thick PVC conduit with 3x1.5Sqmm earth wire Copper multi strand flexible pvc insulated wires and SA Switch cum sockets with Surface/concealed Box with required all materials etc. Supply & Fixing 3 Supply and wiring of Ceiling Fan points With Electronic Step type type Regulators and 2mm Size PVC conduit 3x1.5Sqmm earth wire Copper multi strand flexible pvc insulated wires and SA Switch cum sockets with Surface/concealed Box with required all materials etc. Supply&Fixing 4 SubMains and Mains Supply and wiring of Circuits for Acs with Suitable 2mm thick PVC conduit and 2x4.0 Sqmm +2.55qmm earth wire Copper multi strand flexible pvc insulated wires with Supply and fixing of Metal Clad socket and 25/32A SP MCB and all required all materials etc. 5 Supply & Wiring Supply and wiring of Circuits for Inputs with Suitable Size 2mm thick PVC conduit and 4x6.0 Sqmm +4.0Sqmm earth wire Copper multi strand flexible pvc insulated wires with required all materials etc. (UPS Input) Supply & Wiring $ Supply and wiring of Circuits for Input with Suitable size 2mm thick PVC conduit and 2x6.0 Sqmm +4.0Sqmm earth wire Copper multi strand flexible pvc insulated wires with required all materials etc. (Raw power) Supply& Wiring SWITCH CUM SOCKETS 7 8 9 Supply and fixing of 2No 6A Sockets with 1 No6A Switch control for Raw/UPS Power with Suitable Surface/MS boxes etc Supply& Wiring Supply and fixing of No 6A Sockets with 6A Switch control for above Switch Control Boards with suitable Surface/MS Boxes etc. Including Connections Supply &Fixing Supply and fixing of 2No of 6A Sockets with 1 No of 6A Switch control for Raw/UPS Power with Suitable Surface/MS boxes etc Supply & Fixing 10 11 Supply and fixing of 3No of 6A Sockets with 2. No of 6A Switch control for Raw/UPS Power with Suitable Surface/MS boxes etc. Supply & Fixing Main Panel and Sub Dis Supply and fixing testing and Commissioning of 12 way VTPN Main Incomer Switch--160A 4 Pole 25KA MCCB Outgoing: 63 TPN MCBS -5 Nos. 32A TPN MCBs- 2 Nos, 10-32A SP MCBs-16 Nos with Required Internal wiring etc. Supply& Fixing 12 13 14 LDB Supply & Installation, testing and Commissioning of the 4 way ETPN Double door DB with 63A 4Pole MCB-1No as incomer and Outgoings 10/32A SP MCbs-12 Nos and required all Materials etc for Lighting Supply& Fixing UPS OUTPUT DB Supply & Installation, testing and Commissioning of the 12 way SPN Double door DB with 63/32A 2Pole MCB-1No as incomer and Outgoings- 10/32A SP MCbs-10 Nos and required all Materials etc. For UPS Outgoing Supply& Fixing ACDB Supply & Installation, testing and Commissioning of the 4 way ETPN Double door DB with 63A 4Pole MCB-1No as incomer and Outgoings-10/32A SP MCbs-6 Nos 63A 4p 3nosand required all Materials etc for Lighting Supply& Fixing 15 RAW OUTPUT DB Supply & Installation, testing and Commissioning of the 8 way SPN Double door DB with 63/32A 2Pole MCB-1No as incomer and Outgoings- 10/32A SP MCbs-6 Nos and required all Materials etc. For BRANCH RAW POWER Supply& Fixing 16 RAW OUTPUT DB Supply & Installation, testing and Commissioning of the 8 way SPN Double door DB with 63/32A 2Pole MCB-1No as incomer and Outgoings- 10/32A SP MCbs-6 Nos and required all Materials etc. For ATM UPS DB Supply& Fixing .... more in document

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail