| 1 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work, complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.0sqm each and making good to disturbed surfaces and removing unserviceable materials from site of work complete all as specified and directed by the Engineer-in-Charge. |
| 3 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete fixed to frames complete all as specified and as directed by the Engineer-in-Charge. |
| 4 | S&F Solid PVC door frame for cupboard of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and as directed. |
| 5 | S&F 100mm butt hinges, type B-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised & fixed to PVC door complete all as specified & as directed. |
| 6 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed completeall as specified anddirected. |
| 7 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & directed. |
| 8 | S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed withsteel wire staplescomplete all as specified & directed. |
| 9 | S&F 150 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete in repairs complete all as specified and as directed. |
| 10 | S&F 250mm length of bolt, aluminium alloy, anodized,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete in repairscomplete all as specified and as directed. |
| 11 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete in repairscomplete all as specified and as directed. |
| 12 | S&F mild steel 300mm size, ordinary rat tail rod pattern springs, including roller and roller plate complete fixed to wooden shutter in repairscomplete all as specified and as directed. |
| 13 | Hacking out old broken glass (any thickness, size, quality or description), from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed. |
| 14 | S&F 3mm thickPVC transparent window panesordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each panecomplete all as specified and as directed |
| 15 | S&F 3mm thickPVC frosted window panesordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each panecomplete all as specified and as directed |
| 16 | S&F framed work such as griils, grating, angle iron door frames etc., with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, laders, framed balusters, walk ways, railings frame work of water tanks and similar work conforming to Fe-290. Gde E-165 complete all as specified & as directed. |
| 17 | S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed withsteel wire staples as in repair complete all as specified & directed. |
| 18 | S&F Door closer hydraulically regulated as in repair , aluminium body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in widthand of weight between 61 to 80 kg. Fixed to shutter and frame with steel wooden screws/ suitable welding complete asin repairscomplete all as specified and as directed. |
| 19 | S&FFloor door stopper 140mm size doubled legedof aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor asin repairs. complete all as specified and as directed. |
| 20 | S&F MS chromium plated curtain rod 25 mm dia , with and including MS chromium plated decorative round finials on either end provide a visually balanced appearance including MS chromium plated brackets fixed to wall with 30 mm wooden steel screws and PVC rawl plug, anchors, and installation as in repairscomplete all as specified and as directed. |
| 21 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed. |
| 22 | M&L for second class hardwood, scantlings, wrought, fixed in unframed work complete as specified and directed. |
| 23 | Demolition of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 24 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from ceiling using 4mm GI rods, 1200mm x 600mm centre to centre all complete for all heights as per specificationscomplete all as specified and as directed. |
| 25 | M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system duly suspended with 2 to 3mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips, hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions |
| 26 | S&F 4mm thick Non asbestos fibre cementboards fixed or laid / inserted to timber/GI/Aluminium framework with screws including necessary fillets. |
| 27 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 28 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 29 | S&Fpre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting0.50mm thick of an colour having tensile strength of 550Mpa as , AZ-150in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed |
| 30 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa, AZ-150 as in roof ridges etc. covering/cladding to wall, fixed with self tapping screws with bitiman washer complete all as specified and as directed |
| 31 | Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clan and washing down complete all as specified and as directed |
| 32 | M & L for rendering 15mm thick cement mortar 1:4 over Roof mixed with water proofing compound @ 3% weight of cement or manufacturer instruction finished even and smooth complete all as specified and as directed |
| 33 | M & L for applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | M&L taking down existing plaster at the junction of chajjas and wall over window chajja width not exc 60 CM and applying 15mm thick cement plaster in CM 1:4 mixed with WPC of Pidilite 101 of 200ML for 50 Kg of cement and applying two coats of Cement Base Paint with and including necessary preparation to match with the existing shade.Note :The Rate quoted shall be inclusive of necessary scaffolding upto double storied bldg. |
| 35 | M&L Forming \"V\" grooves in brick or RCC of30mm deep and20 to 30 mm wideon face and applying a primer coat of Pidilite 301 URP and filling the same with mixed with cement in proportion 1:1 , complete all as specified and directed. |
| 36 | M&L fortaking down existing spout pipe and fixing 75 mm dia PVC SWR pipe of length 45 cm long of one side pin headed cutting and fixed in PCC 1:2:4 type B1 and making good the disterubed portion by rtendering 15 mm thick in CM (1:4) and applying two coatd of cement base paint over a coat of primer complete all as specified and directed |
| 37 | M&L for taking down existing spout pipe and fixing 160 mm dia PVC SWR pipe of length 45 cm long of one side pin headed cutting and fixed in PCC 1:2:4 type B1 and making good the disterubed portion by rtendering 15 mm thick in CM (1:4) and applying two coatd of cement base paint over a coat of primer complete all as specified and directed |
| 38 | Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 39 | M& Lfor Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate ) as in roof kerbs or mud stops, rounded or chamfered on edge including necessary form work complete all as specified and directed. |
| 40 | M&L forpreparing new wood & wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. |
| 41 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 42 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 43 | M&L for 50mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded crushedstone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 44 | S&F PVC (SWR) pipes 110 mm diasingle socketed, in any length with rubber ring joints, fixed to walls as in repair complete all as specified and as directed. |
| 45 | S&F PVC (SWR) bends 110 mm dia any radius as in repair all as specified and directed. |
| 46 | S&F PVC (SWR) pipes 75mm diasingle socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 47 | S&F PVC (SWR) bends 75mm dia any radius as in repair complete all as specified and directed. |
| 48 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal from site, for bore of pipes 15mm dia complete all as specified and directed. |
| 49 | S&F 15mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed. |
| 50 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed. |
| 51 | S&F 20mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified & directed. |
| 52 | S&Ffancy type15mm dia Bib taps long body cast copper alloy,chromium plated screwed down to iron pipe or for brass ferrule & fixed complete in repairs, all as specified & directed. |
| 53 | S&F PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e float valve, syphon,flush pipe, bracketsin repairs all as specified and directed by EIC. |
| 54 | Repairs to flushing cistern to address the leakage by replacement of rubber gasket/ washers, complete all as specified and directed |
| 55 | Repairs to flushing cistern to replace the syphon complete all as specified and directed |
| 56 | Repairs to flushing cistern to replace flush handle complete all as specified and directed |
| 57 | S&F PVC connection 15mm size with PTMT nuts of length 600mmin repairs complete all as specified & directed. |
| 58 | Dismantling water tanks exc 250ltr but not exceeding 500ltr capacity complete all as specified and as directed. |
| 59 | Dismantling water tanks exc 500ltr but not exceeding 1000ltr capacity complete all as specified and as directed. |
| 60 | S&F rotational moulded polyethylene water storage tanks of 500 ltr capacity,(cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | S&F rotational moulded polyethylene water storage tanks of 1000 ltr capacity,(cylindrical vertical with closed top) hoisted and fixed in positioncomplete all as specified and as directed by the Engineer-in-Charge. |
| 62 | S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified & as directed. |
| 63 | S&FHealth Faucet with 1 Meter Long Easy Flex Tube in Chrome Finish and Wall Hook with N.R.V (Back Flow Preventer) with clamp in repair complete all as specified and as directed by the Engineer-in-Charge. |
| 64 | Material and labour for water proofing treatment to sunken floor with the following course of treatment as specified below,all as per manufacture\"s instruction complete and all as directed by Engr-in-charge:-(i) cleaning top surface of floors/slab and laying 50mm thick(avg) PCC of grade M-10 (Nominal mix),mixed with WPC as per manufacturer\"s instruction laid in slope 1:20 towards spouts including coveting corners.(ii) 15 mm thick plastering in CM (1:4) ON side & bottom mixed with WPCas per manufacture\"s instruction.(iii) Applying 1st layer of slurry of cement @ 0.488 kg/sqm mixed with acrylic based polymer modified cementitous compound @0.253 kg/sqm.This layer shall be allowed to air cured for 4hrs.(iv)Applying 2 ndlayer of slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitous compound @0.126 kg/sqm.This layer shall be allowed to air cured for 48hrs.(v) Applying a coat of industerial bitumen 85/25 conforming to IS :3384:1986 penetration @ penetration @ 1.50 kg/sqm on plastered and concrete surface.(vi) providing 150 micron thick polythene sheet in two layer (each 75 micron measured dry on dry surface over a coat of PU primer including preparation.(vii) 2 Nos 32mm bore GI medium grade 450mm long spout to be provided through external wall to drainout accumulated water.(viii) sunken floor shall be tested for water tightness as specified at para 12.3 of PS (ix) Sunken portion shall be filled with lean conrete of grade(1:3:6) type C-2 (using 40mm graded stone aggrete). |
| 65 | S&F in repair vitreous china wash down watercloset, \"Pedestal pattern with fixing bolt, plastic water closet seat cover, white, closed pattern with flat bottom and cover with aluminised hinging device, complete all as specified & directed. |
| 66 | Dismantling of floor, hearth or wall tiling including cement mortar bedding(but not backing) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge. |
| 67 | M&L for 300mm x 300mm heavy duty out door ceremic tiles 9 to 10 mm thick (capsule star or coin pattern) as in floor etc laid over and including screed bed or badding layer of mortar 15mm thk in CM 1:6 for laying floor finishing set and joind in neat cement slurry and pointed in white or coloured cement to match with and including a levelingcourse of 25 mm thk PCC 1:2:4 type B 0 (using 12.5mm graded stone graded stone aggregate) complete all as specified and directed. |